Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard package testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

New Tools for Automating Arcjet Sample Recession Tracking and Analysis

Arcjet Computer Vision (arcjetCV) has been significantly upgraded to enhance accuracy and performance in tracking material recession and shock-material standoff in test videos. These improvements include integrating new machine learning models, developing a specialized edge detection class, and incorporating a more comprehensive training dataset. These upgrades have refined the software’s ability to automate time-resolved recession tracking, making it more precise and reliable for analyzing complex physical processes. In parallel, a new tool called STARscan (Spatial Targeting and Alignment Rig for Scanning) is being developed to capture detailed 3D surface data before and after testing. By comparing these pre- and post-test scans with arcjetCV’s automated video analysis results, users can achieve a more comprehensive assessment of material recession. This method enables cross-validation of results, improving confidence in the analysis of tested materials. The expanded capabilities of arcjetCV have been successfully demonstrated on videos from various facilities, including the NASA Ames arcjets, UIUC’s PlasmatronX, and the VKI Plasmatron. It has been adopted as a new standard for in-situ recession tracking by the Mars Sample Return Project and Orion. ArcjetCV’s improved efficiency and accuracy are critical for reducing testing uncertainties and validating heatshield material performance under extreme conditions. The software’s user-friendly graphical interface ensures ease of use, enabling seamless processing and precise analysis of arcjet videos, providing deeper insights into material behavior in hypersonic environments. ArcjetCV is now available on both PyPI and Conda, allowing easy installation via "pip install arcjetCV" or through the Conda package manager, ensuring broad accessibility and streamlined deployment for users across various platforms.

Ablation↗

Lunar Simulants: JSC-1 is Gone; The Need for New Standardized Root Simulants

A workshop was held in 1991 to evaluate the status of simulated lunar regolith material and to make recommendations on future requirements and production of such material. As an outgrowth of that workshop, a group centered at Johnson Space Center (JSC) teamed with James Carter of the University of Texas at Dallas and Walter Boles of Texas A&M University to produce and distribute a new standardized lunar regolith simulant termed JSC-1. Carter supervised the field collection, shipping, processing, and initial packaging and transportation of JSC-1. Boles stored and distributed JSC-1. About 25 tons were created and distributed to the lunar science and engineer community; none is left for distribution. JSC-1 served an important role in concepts and designs for lunar base and lunar materials processing. Its chemical and physical properties were described by McKay et al., with its geotechnical properties described by Klosky et al.. While other lunar regolith simulants were produced before JSC-1, they were not standardized, and results from tests performed on them were not necessarily equivalent to test results performed on JSC-1. JSC-1 was designed to be chemically, mineralogically, and texturally similar to a mature lunar mare regolith (low titanium). The glass-rich character of JSC-1 (approx. 50%) produced quite different properties compared to other simulants that were made entirely of comminuted crystalline rock, but properties similar to lunar mare near surface regolith.

Carter, James L.↗

Commercial-Off-The-Shelf Microelectromechanical Systems (MEMS) Flow-Measurement Probes Fabricated And Assembled

As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.

Redding, Chip↗

Impact of Time-Dependent Reactor and Sensor Physics on Core Power Synthesis (Rev.1)

Online synthesis of power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins and to provide essential knowledge associated with the burnup of the fuel. In light-water reactors, power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report examines the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a pressurized water reactor (PWR), considering the typical low-enriched uranium (LEU, 3%-5% enrichment) fuel cycle as well as the higher enrichment LEU+ (5%-8% enrichment) fuel cycle. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative PWR LEU core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used as well to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori power distribution assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters and the extended nature of the LEU+ fuel cycle in comparison with LEU. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly underapproximated or overapproximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumptions leads to severe levels of error, approaching 25% at maximum (for LEU). The authors also discovered that V SPNDs are extraordinarily robust in both the LEU and LEU+ fuel cycles considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Time Dependent Reactor and Sensor Physics on Core Power Synthesis

Online synthesis of the power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins, and to provide essential knowledge associated with the burnup of the fuel. In light water reactors (LWRs), power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report aims to study the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a LWR. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative pressurized water reactor low-enriched uranium (LEU) core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used, as well, to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative (PBI) method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly under- or over-approximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumption leads to severe levels of error, approaching 25% at maximum. The authors also discovered that V SPNDs are extraordinarily robust in the low-enriched uranium fuel cycle considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability and quality EEE parts issues

NASA policy and procedures are established which govern the selection, testing, and application of electrical, electronic, and electromechanical (EEE) parts. Recent advances in the state-of-the-art of electronic parts and associated technologies can significantly impact the electronic designs and reliability of NASA space transportation avionics. Significant issues that result from these advances are examined, including: recent advances in microelectronics technology (as applied to or considered for use in NASA projects); electron packaging technology advances (concurrent with, and as a result of, the development of the advanced microelectronic devices); availability of parts used in space avionics; and standardization and integration of parts activities between projects, centers, and contractors.

Barney, Dan↗

Improvement in surface fatigue life of hardened gears by high-intensity shot peening

Two groups of carburized, hardened, and ground spur gears that were manufactured from the same heat vacuum induction melted vacuum arc melted (VIM VAR) AISI 9310 steel were endurance tested for surface fatigue. Both groups were manufactured with a standard ground 16 rms surface finish. One group was subjected to a shot peening (SP) intensity of 7 to 9A, and the second group was subjected to a SP intensity of 15 to 17A. All gears were honed after SP to a surface finish of 16 rms. The gear pitch diameter was 8.89 cm. Test conditions were a maximum Hertz stress of 1.71 GPa, a gear temperature of 350 K, and a speed of 10000 rpm. The lubricant used for the tests was a synthetic paraffinic oil with an additive package. The following results were obtained: The 10 pct. surface fatigue (pitting) life of the high intensity (15 to 17A) SPed gears was 2.15 times that of the medium intensity (7 to 9A) SPed gears, the same as that calculated from measured residual stress at a depth of 127 microns. The measured residual stress for the high intensity SPed gears was 57 pct. higher than that for the medium intensity SPed gears at a depth of 127 microns and 540 pct. higher at a depth of 51 microns.

Townsend, Dennis P.↗

Vicarious Calibration of GOCI for the SeaDAS Ocean Color Retrieval

A key on-orbit calibration step for satellite remote sensing of ocean color is the vicarious calibration. This establishes the final gains for each spectral band on the sensor that minimize bias in the retrieved ocean color signal. The vicarious calibration is specific to the instrument and the atmospheric correction algorithm. The vicarious calibration gains for the Geostationary Ocean Color Imager (GOCI) are presented here, which were derived to optimize the performance ofNASA's standard atmospheric correction algorithm as implemented in the l2gen code and distributed through the SeaDAS open-source software package. Following NASA's protocols, the near-infrared(NIR) bands were calibrated first, and the visible bands were then calibrated relative to this fixed NIR calibration. The gain for the 745-nm NIR band was derived using a fixed aerosol model, which waschosen based on the Angstrom Coefficients derived from MODIS onAqua (MODISA). For the vicarious gains of the visible bands, twosources for the target water-leaving radiances were tested: matchupsfrom MODISA and climatological data from SeaWiFS. A validation analysis using AERONET-OC data shows an improvement in sensor performance when compared with results using the current vicarious gains and results using no vicarious calibration. Good agreement was found in vicarious gains derived using both concurrent MODISA and climatological SeaWiFS as vicarious calibration data sources. These results support the use of a concurrent sensor for the vicarious calibration when in situ data are not available and demonstrate that using climatology from a well-calibrated sensor like SeaWiFSfor the vicarious calibration is a valid alternative when it is not possible to use a concurrent sensor or in situ data. We recommend using the gains derived from concurrent GOCI matchups with MODISA for GOCI processing in SeaDAS/l2gen.

Concha, Javier↗

Development of a graphical display on the DMS test bed

The DMS test bed is a model of a data network aboard space station. Users of the network share data relevant to the functional status of various systems aboard the station. Users may inquire the status of myriad sensors, obtaining reading of station subsystem status in real time via the Data Acquisition and Distribution Service. A graphical display of the status of a simulation of the Environmental Control and Life Support System was developed. Two broad issues were addressed: (1) flexible, extensible software design; and (2) the impact of utilizing standard processors, languages, and graphics packages implementing the software design concept. The experience gained with DEC hardware, the DEC implementation of the GKS graphics standard, and with Ada is summarized.

Donnelly, Robert A.↗

Evaluation of Correction Methods for NASA GeneLab Transcriptomic Datasets

Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets. In the present study, NASA GeneLab-hosted RNAseq datasets from mouse liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC to determine statistical differences between datasets before and after correction, Principal Component Analysis to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. The results showed that the reference-based approach introduced several additional (and likely artificial) DEGs when compared with the respective standard approach. Of the methods tested, standard ComBat and DESeq2 were identified as the most robust correction methods for combining spaceflight mouse liver RNAseq datasets hosted on GeneLab.

GeneLab↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

Gerke, R. David↗

Combining RNA-SEQ Datasets from NASA GENELAB: An Evaluation of Correction Methods

Background: Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets. Methods: In the present study, NASA GeneLab-hosted RNAseq datasets from mouse liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, the median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC to determine statistical differences between datasets before and after correction, Principal Component Analysis to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. Results: The results showed that the reference-based approach introduced several additional (and likely artificial) differentially expressed genes when compared with the respective standard approach. Conclusions: Of the methods tested, standard ComBat_seq and DESeq2 were identified as the most robust correction methods for combining spaceflight mouse liver RNAseq datasets hosted on GeneLab.

Finsam Samson↗

Pressure visualization (PreViz) package version 1.0 user's guide

The Pressure Visualization (PreViz) package is a software tool which merges a wireframe model of the test aircraft with pressure data represented as a series of displacement vectors normal to the aircraft's skin. The PreViz package automates much of the researcher's data reduction effort, reduces the time required to review large amounts of pressure data, presents the data more clearly than tabular listings, and provides a wireframe description for a black and white graphic suitable for a technical publication (the actual graphic images must be created by a local package since PreViz has no graphics capability). Although designed for pressure data, the PreViz package works equally well for any surface property (such as structural loading or skin temperature). Written in ANSI-standard FORTRAN 77 and self-contained, PreViz executes in UNIX, VAX/VMS, and CDC/NOS host environments.

Bingel, Bradford D.↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

NASA Electronic Parts & Packaging (NEPP) Program

The purpose of this presentation is to familiarize the people attending the JEDEC work meetings about the NEPP Program, and recent tasks we have undertaken. There is a description of the policy and testing guidelines in development and an explanation of the Government Working Group, a collaboration of several US government space agencies that come together to discuss topics relating to the reliable use of electronics. The presentation also includes a brief description of NASA events such as the landing of the next Mars rover in Feb 2021.

reliability↗

The standardized functional support sectional for the Small Astronomy Satellite (SAS)

The standardized functional support section for the improved Small Astronomy Satellite (SAS) spacecraft, which can be used virtually without change for a wide variety of experimental packages and missions, is described. This functional support section makes the spacecraft remarkably flexible for a small satellite. Able to point its thrust axis to any direction in space, it can also spin or slow its outer body rotation to zero for star- or earth-locked pointing of side-viewing experiments. It features a reprogrammable telemetry system, a delayed command system, and an improved control system. Experiments can be built independently and attached to the SAS spacecraft just prior to final acceptance testing and launch. The spacecraft subsystems are described in detail. Included are a summary of the spacecraft characteristics, special design considerations, project reliability requirements, and environmental test conditions. It is intended that this new functional support section afford virtual off-the-shelf availability of the SAS spacecraft to independently built experiments, thus providing quick response time and minimum cost in meeting a wide variety of experimenter needs.

Townsend, M. R.↗

Space processing applications payload equipment study. Volume 2E: Commercial equipment utility

Examination of commercial equipment technologies revealed that the functional performance requirements of space processing equipment could generally be met by state-of-the-art design practices. Thus, an apparatus could be evolved from a standard item or derived by custom design using present technologies. About 15 percent of the equipment needed has no analogous commercial base of derivation and requires special development. This equipment is involved primarily with contactless heating and position control. The derivation of payloads using commercial equipment sources provides a broad and potentially cost-effective base upon which to draw. The derivation of payload equipment from commercial technologies poses other issues beyond that of the identifiable functional performance, but preliminary results on testing of selected equipment testing appear quite favorable. During this phase of the SPA study, several aspects of commercial equipment utility were assessed and considered. These included safety, packaging and structural, power conditioning (electrical/electronic), thermal and materials of construction.

Smith, A. G.↗