Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SUPERDIFFUSIVE SHOCK ACCELERATION

The theory of diffusive shock acceleration is extended to the case of superdiffusive transport, i.e., when the mean square deviation grows proportionally to t{sup {alpha}}, with {alpha} > 1. Superdiffusion can be described by a statistical process called Levy random walk, in which the propagator is not a Gaussian but it exhibits power-law tails. By using the propagator appropriate for Levy random walk, it is found that the indices of energy spectra of particles are harder than those obtained where a normal diffusion is envisaged, with the spectral index decreasing with the increase of {alpha}. A new scaling for the acceleration time is also found, allowing substantially shorter times than in the case of normal diffusion. Within this framework we can explain a number of observations of flat spectra in various astrophysical and heliospheric contexts, for instance, for the Crab Nebula and the termination shock of the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal parametric discrete event control: Problem and solution

We present a novel optimization problem for discrete event control, similar in spirit to the optimal parametric control problem common in statistical process control. In our problem, we assume a known finite state machine plant model G defined over an event alphabet Sigma so that the plant model language L = L M (G) is prefix closed. We further assume the existence of a base control structure M K , which may be either a finite state machine or a deterministic pushdown machine. If K = L M (M K ), we assume K is prefix closed and that K C L. We associate each controllable transition of M K with a binary variable X 1 ,..., X n middot indicating whether the transition is enabled or not. This leads to a function M K (X 1 , ,...,- , X n ), that returns a new control specification depending upon the values of X 1 ,..., X n middot We exhibit a branch-and-bound algorithm to solve the optimization problem minx 1 x,...x n &maxwwepsiK C(w) such that M K (X 1 ,...,X n ) \= |= and L M (M K (X 1 ,...,- , X n middot)) epsi C(L). Here . is a set of logical assertions on the structure of M K (X 1 , X 1 ,...,- , X n middot), and M K (X 1 ,...,- , X n middot) \= || indicates that M K (X 1 ,...,- , X n ) satisfies the logical assertions; and, C(L) is the set of controllable sublanguages of L 1 .

42 ENGINEERING↗

Determining a purely symbolic transfer function from symbol streams: Theory and algorithms

Transfer function modeling is a standard technique in classical linear time invariant and statistical process control. The work of Box and Jenkins was seminal in developing methods for identifying parameters associated with classical (r, s, k) transfer functions. Discrete event systems are often used for modeling hybrid control structures and high-level decision problems. Examples include discrete time, discrete strategy repeated games. For these games, a discrete transfer function in the form of an accurate hidden Markov model of input-output relations could be used to derive optimal response strategies. In this paper, we develop an algorithm for creating probabilistic Mealy machines that act as transfer function models for discrete event dynamic systems (DEDS). Our models are defined by three parameters, (l 1 ,l 2 ,k) just as the Box-Jenkins transfer function models. Here h is the maximal input history lengths to consider, l 2 is the maximal output history lengths to consider and k is the response lag. Using related results, We show that our Mealy machine transfer functions are optimal in the sense that they maximize the mutual information between the current known state of the DEDS and the next observed input/output pair.

42 ENGINEERING↗

Assessment of Dimensional Integrity and Spatial Defect Localization in Additive Manufacturing Using Spectral Graph Theory

The ability of additive manufacturing (AM) to produce components with virtually any ge-ometry presents a unique challenge in terms of quantifying the quality of the part. In this paper, a novel spectral graph theory (SGT) approach is proposed for resolving two critical quality assurance concerns in AM: (1) how to quantify the dimensional integrity of complex AM components; and (2) how to isolate specific spatial locations on a component that deviate significantly from their normal condition. Here, the SGT approach is demonstrated for classifying the dimensional integrity of standardized test components produced from three different AM processes. The SGT-based topological invariant Fiedler number ( λ 2 ) was calculated from 3D point cloud coordinate measurements and used to quantify the dimensional integrity of test components. The Fiedler number was found to differ significantly for parts originating from different AM processes (statistical significance p-val. < 1%). By comparison, traditional statistical quantifiers (such as mean and standard deviation) and examination of specific facets/landmarks failed to capture these variations and proved incapable of quantifying the quality of the component in a consistent manner. The SGT approach was verified to consistently rank the quality of the AM components with a high degree of statistical confidence independent of sampling technique used (pooled standard deviation ~ 3% 10% of mean). Finally, from a practical standpoint, the SGT approach can be a powerful tool for quantifying and monitoring the dimensional integrity and overall quality of AM components, and thus encourage wider adoption of AM capabilities.

42 ENGINEERING↗

SU-E-T-77: A Statistical Approach to Manage Quality for Pre-Treatment Verification in IMRT/VMAT

Objective: The study presents the application of a simple concept of statistical process control (SPC) for pre-treatment quality assurance procedure analysis for planar dose measurements performed using 2D-array and a-Si electronic portal imaging device (a-Si EPID). Method: A total of 195 patients of four different anatomical sites: brain (n1=45), head & neck (n2=45), thorax (n3=50) and pelvis (n4=55) were selected for the study. Pre-treatment quality assurance for the clinically acceptable IMRT/VMAT plans was measured with 2D array and a-Si EPID of the accelerator. After the γ-analysis, control charts and the quality index Cpm was evaluated for each cohort. Results: Mean and σ of γ ( 3%/3 mm) were EPID γ %≤1= 99.9% ± 1.15% and array γ %<1 = 99.6% ± 1.06%. Among all plans γ max was consistently lower than for 2D array as compared to a-Si EPID. Fig.1 presents the X-bar control charts for every cohort. Cpm values for a-Si EPID were found to be higher than array, detailed results are presented in table 1. Conclusion: Present study demonstrates the significance of control charts used for quality management purposes in newer radiotherapy clinics. Also, provides a pictorial overview of the clinic performance for the advanced radiotherapy techniques.Higher Cpm values for EPID indicate its higher efficiency than array based measurements.

60 APPLIED LIFE SCIENCES↗

TU-B-304-01: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-02: Quantitative FMEA of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

SU-F-P-33: Combining Research and Professional Practice in the Clinical Setting: A Medical Physicist Personal Experience

Purpose: To initiate a discussion on the current and evolving role of Medical Physicists based on author’s professional and research experience in patient safety and quality control. Methods: Several professionals of the departments of Medical Physics and Radiation Oncology, chiefly devoted to clinical tasks, began a research program on patient safety and quality control in a framework provided by the implementation of intraoperative radiotherapy (IORT). We performed studies on virtual simulation for IORT, in vivo dosimetry, failure mode and effect analysis (FMEA), statistical process control (SPC), and receiver operating characteristics of dosimetric equipment. This was done with the support of our research foundation and different grants while continuing with our departmental clinical routine involving about 1600 annual treatments with two linacs and different brachytherapy techniques. Results: We published 5 papers in international journals in the last two years. This author conducted a doctoral research which resulted in a dissertation in 2015. The extra time spent after treatments was essential to succeed. Funding and support achieved via our foundation played a crucial role; but this would have not been possible without punctual external mentoring and partnership. FMEA conclusions were able to be implemented only with staff commitment; however, conclusions concerning equipment cannot be easily communicated to manufacturers. These tasks required extra training in the appropriated methods. Conclusion: Research needed the support of a dedicated foundation, which would have been very difficult to obtain with the sole participation of our departments. FMEA and SPC results may need engagement of staff and manufacturers, respectively, hard to achieve without strong recommendations or even a regulatory framework. All these fields need evolution of Medical Physicists’ roles and additional training. Devotion to both clinical tasks and research could be unfeasible for Medical Physicists in the clinical setting without the appropriate rearrangement of their schedules and tasks. Supported by grants IPT-300000-2010-3 and PI11/01659. ERDF funds and Spanish Government.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-CD-207A-11: Sensitivity Analysis of Action Limits for Real-Time EPID-Based Delivery Verification System Using Artificial Clinical Relevant Error Simulations

Purpose: A real-time patient treatment delivery verification system using EPID (Watchdog) has been developed as an advanced patient safety tool. In a pilot study data was acquired for 119 prostate and head and neck (HN) IMRT patient deliveries to generate body-site specific action limits using statistical process control. The purpose of this study is to determine the sensitivity of Watchdog to detect clinically significant errors during treatment delivery. Methods: Watchdog utilizes a physics-based model to generate a series of predicted transit cine EPID images as a reference data set, and compares these in real-time to measured transit cine-EPID images acquired during treatment using chi comparison (4%, 4mm criteria) after the initial 2s of treatment to allow for dose ramp-up. Four study cases were used; dosimetric (monitor unit) errors in prostate (7 fields) and HN (9 fields) IMRT treatments of (5%, 7%, 10%) and positioning (systematic displacement) errors in the same treatments of (5mm, 7mm, 10mm). These errors were introduced by modifying the patient CT scan and re-calculating the predicted EPID data set. The error embedded predicted EPID data sets were compared to the measured EPID data acquired during patient treatment. The treatment delivery percentage (measured from 2s) where Watchdog detected the error was determined. Results: Watchdog detected all simulated errors for all fields during delivery. The dosimetric errors were detected at average treatment delivery percentage of (4%, 0%, 0%) and (7%, 0%, 0%) for prostate and HN respectively. For patient positional errors, the average treatment delivery percentage was (52%, 43%, 25%) and (39%, 16%, 6%). Conclusion: These results suggest that Watchdog can detect significant dosimetric and positioning errors in prostate and HN IMRT treatments in real-time allowing for treatment interruption. Displacements of the patient require longer to detect however incorrect body site or very large geographic misses will be detected rapidly.

60 APPLIED LIFE SCIENCES↗

Data and scripts associated with “Moisture content modulates DOM thermodynamic regulation of oxygen consumption in drying streambed sediments”

This data package is associated with the publication “Moisture content modulates DOM thermodynamic regulation of oxygen consumption in drying streambed sediments” published in Scientific Reports (Garayburu-Caruso et al., 2026). The package contains processed data products and scripts used to quantify how drying and re-inundation of riverbed sediments influence dissolved organic matter (DOM) thermodynamic properties and their relationship with sediment oxygen (O₂) consumption across 33 stream sites in the contiguous United States. The data package contains DOM thermodynamic metrics (e.g., Gibbs free energy of carbon oxidation and thermodynamic efficiency), and O₂ consumption along with watershed-scale climate and land-cover metrics used as explanatory variables in the analyses. Underlying unprocessed and processed ultrahigh-resolution mass spectrometry data, oxygen consumption rates from laboratory moisture-manipulation experiments, within-sample environmental properties, sediment moisture content and contextual field measurements are archived separately at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2428003 (Laan et al., 2024) and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1923689 (Forbes et al.,2023). A preliminary version of this data package was published in February 2026 at the time of manuscript submission. It was updated in June 2026, at the time of manuscript acceptance, to include the finalized data and additional metadata (readme, data dictionary, and file level metadata). For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. At the top level, the data package is organized into five main folders: (1) Data, (2)Figures, (3) Map, (4) GAM_Reulsts, and (5) src. The Data folder contains analysis-ready tabular files with oxygen consumption rates, DOM thermodynamic properties by site and treatment, site-level environmental variables, watershed-scale metrics, and other derived variables referenced in the manuscript. The Figures folder contains static image files associated with the main text and supplemental figures, while the Map folder includes spatial data and map-layer files used to create the sampling-location map. The GAM results folder contains the results for each of the general additive model (GAM).The src folder contains R scripts used to perform data processing, statistical analyses (including clustering, generalized additive models, and threshold analysis), and figure generation. This data package is associated with a GitHub repository found at https://github.com/WHONDRS-Hub/ECA_DOM_Thermodynamics.

Dissolved organic matter↗

UCRLDetermination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication. While the method of analyzing the inter arrival times of neutrons using count distributions to determine characteristics of the source has been used for a long time, the treatment of the errors on the determined quantities multiplication M and source strength S have not yet been adequately treated. This object of this report is to assess these errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication.The results of this study show that analyzing the data stream using non-overlapping time gates is an improvement over the current analysis using overlapping time gates. The new method enables us to compute the standard deviation on the multiplication parameter M accurately. Also, this standard deviation on M decreases as the largest time gate is about 10 times the characteristic time constant λ -1 of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CMM Interim Check (U)

Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length. Unfortunately, several nonconformance reports have been generated to document the discovery of a certified machine found out of tolerance during a calibration closeout. In an effort to reduce risk to product quality two solutions were proposed – shorten the calibration cycle which could be costly, or perform an interim check to monitor the machine’s performance between cycles. The CMM interim check discussed makes use of Renishaw’s Machine Checking Gauge. This off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. Data was gathered, analyzed, and simulated from seven machines in seventeen different configurations to create statistical process control run charts for on-the-floor monitoring.

42 ENGINEERING↗

Next Generation Logistics Systems for Delivering Optimal Biomass Feedstocks to Biorefining Industries in the Southeastern U.S.

The diverse portfolio of biomass sources that is available in the Southeastern U.S., including a significant supply of pine “residue”, represents a valuable strategic position for the region. Through blends formulated based on critical properties, this project will take full advantage of the range in biomass properties afforded by the portfolio to produce a consistent, high-performance feedstock for the industry, while lowering cost. Key developments being targeted to enable this potential include whole-tree transport to a state-of-the-art merchandising depot that will further access biomass from ongoing, forest industry operations. The approach will more effectively utilize the tree and distribute cost, while minimizing in-woods contamination of the woody biomass component. To implement this vision, information on the chemical composition and changes that are induced during multiple preprocessing steps (size reduction, moisture removal, densification, etc.) is needed. New NIR sensor technology will be developed for online monitoring of important biomass properties. The data will be incorporated into a statistical process control platform to improve process efficiency and meet required specifications. Advanced process models are being developed to inform the techno-economic and life-cycle assessment of the program’s impact. The new system will ultimately reduce operational risks from supply chain disruptions, and allow operation of larger-scale biorefineries.

09 BIOMASS FUELS↗

An Overview of Manufacturing Controls for Production of High-Consequence, Single-Use Systems

Extended Testing (Crowder, et al. (2025) ) is a reliability demonstration technique that can be used to dramatically reduce sample size requirements. Manufacturing controls are needed to supplement extended testing by identifying production issues that a reduced sample sizes might overlook, especially built-in, or latent, manufacturing defects. This report focuses on some of the most commonly used, yet most impactful, manufacturing control tools that are used to limit production-related defects and efficiently screen any remaining defects at final inspection. These tools include statistical process control (SPC), acceptance sampling, environmental stress screening (HASS and ESS), and mistake proofing. The goal is to minimize the probability that built-in defects ever reach the customer. In terms of nuclear weapons (NW), the goal is to prevent defective units from ever entering the nation’s NW stockpile. Examples of each of the techniques are illustrated with case studies.

42 ENGINEERING↗

Omics-Lethal Human Viruses, Ebola Experiment EHUH001

The purpose of this experiment was to evaluate the human host response to Zaire Ebola wild-type virus and mutant virus infection. Samples were obtained from human hepatoma carcinoma cells (HUH-7) infected with Zaire Ebola ΔVP30-WT background, in addition to mutant viruses Ebola-ΔsGP (eliminating expression of soluble glycoprotein ssGP) and Ebola-Δmucin (encoding a glycoprotein lacking the mucin domain) for mRNA and miRNA transcriptome expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Transcriptomics dataset downloads have a direct relationship to a primary sample submission corresponding to a specific Ebola virus infection.

59 BASIC BIOLOGICAL SCIENCES↗