Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Using Dashboards to Improve Energy and Comfort in Federal Buildings

Federal agencies are taking many steps to improve the sustainability of their operations, including improving the energy efficiency of their buildings, promoting recycling and reuse of materials, encouraging carpooling and alternative transit schemes, and installing low flow water fixture units are just a few of the common examples. However, an often overlooked means of energy savings is to provide feedback to building users about their energy use through information dashboards connected to a building?s energy information system. An Energy Information System (EIS), broadly defined, is a package of performance monitoring software, data acquisition hardware, and communication systems that is used to collect, store, analyze, and display energy information. At a minimum, the EIS provides the whole-building energy-use information (Granderson 2009a). We define a ?dashboard? as a display and visualization tool that utilizes the EIS data and technology to provide critical information to users. This information can lead to actions resulting in energy savings, comfort improvements, efficient operations, and more. The tools to report analyzed information have existed in the information technology as business intelligence (Few 2006). The dashboard is distinguished from the EIS as a whole, which includes additional hardware and software components to collect and storage data, and analysis for resources and energy management (Granderson 2009b). EIS can be used for a variety of uses, including benchmarking, base-lining, anomaly detection, off-hours energy use evaluation, load shape optimization, energy rate analysis, retrofit and retro-commissioning savings (Granderson 2009a). The use of these EIS features depends on the specific users. For example, federal and other building managers may use anomaly detection to identify energy waste in a specific building, or to benchmark energy use in similar buildings to identify energy saving potential and reduce operational cost. There are several vendors of EIS technology that provide information on energy and other environmental variables in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Speed and Memory Improvements to MCNP6 Delayed-Gamma Line Treatment

The delayed-gamma (DG) line-emission (line) sampling was first introduced into MCNPX in 2005. At the time, storage demands for problems with large numbers of DG lines was a major concern. In order to accommodate large amounts of line data while keeping the memory footprint of such a problem from exceeding memory limits, complicated logic was included to sift through various storage options. In mid-2015 concerns arose over the adequacy of the MCNP6 DG source option (inherited from MCNPX) with line sampling for modeling high-fidelity problems. One indication that there was a problem came when studying the MCNP6 produced DG spectra of U-238 and its progeny using high-fidelity spectroscopic tallies when compared to DG line amplitudes directly from ENDF/B-VII.1 emission data. Despite producing a correct integral number of gammas, the comparison to ENDF data showed a broadening in the energy lines and a reduction in the amplitude of more prominent lines. It was later found that the cause of this broadening was one of the memory-saving techniques used to store DG line data when problems required many DG lines. Specifically, the DG lines were integrated into fine energy bins for sampling. When a DG line was to be sampled, a random number would be used to choose which energy bin to sample based on emission probability. Once chosen, a second random number was used to perform nearest-line sampling in that bin. The integration of lines led to an oversampling of low-probability lines, especially when in close proximity to high-probability lines. This treatment also caused a similar issue with the time-dependent behavior of DG line emission which occurred when low-probability lines were sampled near high probability lines with the former decay constant being used. The effect on time-dependent gamma production was demonstrated in analytic benchmarks performed by Weldon et al.. To address these issues a new gamma line storage and sampling treatment was introduced in 2015. This new treatment, stores gamma emission data in a line-by-line CDF which is sampled directly, thereby resolving both the line-broadening issue, and the time-dependence issue as was demonstrated by Tutt el al.. In addition, the new DG sampling treatment was written to use dynamically dimensioned storage arrays as opposed to large fixed-dimensioned arrays, as in the former treatment, and also makes more efficient use of line data that is stored by reducing or eliminating repeated data. As a result, storage arrays are generated only for DG data relevant to the problem being executed. The result should be a reduction in both memory requirements and runtime. However, these reductions could not be realized until the logic for the old treatment could be removed. This paper provides an update on recent work which has focused on the removal of the old DG sampling logic and attempts to quantify the memory reduction and speed up of selected problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Betatron Tune Shifts Induced by the Low-Frequency Resistive Wall Impedance

An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability $μ_r$. In the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets ($μ_r$ → $\infty$), and the case in which the magnets are fully saturated ($μ_r$ = 1).

36 MATERIALS SCIENCE↗

Application of low dissipation and dispersion Runge-Kutta schemes to benchmark problems in computational aeroacoustics

We investigate accurate and efficient time advancing methods for computational aeroacoustics, where non-dissipative and non-dispersive properties are of critical importance. Our analysis pertains to the application of Runge-Kutta methods to high-order finite difference discretization. In many CFD applications, multi-stage Runge-Kutta schemes have often been favored for their low storage requirements and relatively large stability limits. For computing acoustic waves, however, the stability consideration alone is not sufficient, since the Runge-Kutta schemes entail both dissipation and dispersion errors. The time step is now limited by the tolerable dissipation and dispersion errors in the computation. In the present paper, it is shown that if the traditional Runge-Kutta schemes are used for time advancing in acoustic problems, time steps greatly smaller than that allowed by the stability limit are necessary. Low Dissipation and Dispersion Runge-Kutta (LDDRK) schemes are proposed, based on an optimization that minimizes the dissipation and dispersion errors for wave propagation. Optimizations of both single-step and two-step alternating schemes are considered. The proposed LDDRK schemes are remarkably more efficient than the classical Runge-Kutta schemes for acoustic computations. Numerical results of each Category of the Benchmark Problems are presented. Moreover, low storage implementations of the optimized schemes are discussed. Special issues of implementing numerical boundary conditions in the LDDRK schemes are also addressed.

Hu, F. Q.↗

Least-cost Optimal Distribution Grid Expansion (LODGE) v1

LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate new loads and behind-the-meter DERs in combination with advanced non-wire alternative (NWA) planning solutions, such as utility-owned storage and distributed PV. Working with a set of least-cost solutions per feeder/substation allows us to benchmark and compare techno-economic performance of different traditional and NWA planning solutions. An important aspect of the LODGE model is that it includes power flow operation constraints. This means that the least-cost planning solutions delivered by LODGE are technically feasible. Available projects in LODGE portfolio include: 1) feeder reconductoring; 2) transformers upgrades; 3) non-wire alternatives, such as strategic siting and sizing of storage and distributed PV; 4) voltage regulators.

Heleno, Miguel↗

Can I/O Variability Be Reduced on QoS-Less HPC Storage Systems?

For a production high-performance computing (HPC) system, where storage devices are shared between multiple applications and managed in a best effort manner, I/O contention is often a major problem. In this paper, we propose a balanced messaging-based re-routing in conjunction with throttling at the middleware level. This work tackles two key challenges that have not been fully resolved in the past: whether I/O variability can be reduced on a QoS-less HPC storage system, and how to design a runtime scheduling system that can scale up to a large amount of cores. The proposed scheme uses a two-level messaging system to re-route I/O requests to a less congested storage location so that write performance is improved, while limiting the impact on read by throttling re-routing. An analytical model is derived to guide the setup of optimal throttling factor. We thoroughly analyze the virtual messaging layer overhead and explore whether the in-transit buffering is effective in managing I/O variability. Contrary to the intuition, in-transit buffer cannot completely solve the problem. It can reduce the absolute variability but not the relative variability. The proposed scheme is verified against a synthetic benchmark as well as being used by production applications.

Huang, Dan↗

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Subcriticality Measurements with HEU (93.2) Metal Annular Storage Castings

These carefully performed and documented measurements with unreflected and unmoderated highly enriched uranium (HEU) castings can be used to benchmark calculational methods for the time decay of the fission chain multiplication process as measured with small (1 x 1 x 6 in. thick plastic scintillators with 1/4-in.-thick lead on all detector surfaces) detectors adjacent to the tightly fitting stainless steel cans that contained the HEU ({approx}93 wt%) metal. Prompt time decay measurements were performed stimulating the fission chain multiplication process with a timed, tagged Cf spontaneous fission source that emitted fission-spectrum neutrons and a time and directionally tagged 14.1-MeV neutrons from the DT reaction in a steady state generator with an embedded alpha detector. Time decay measurements were performed with HEU masses varying from 18 to 90 kg for a wide variety of source-detector-casting configurations. The use of a DT generator provided no addition information about the fission chain behavior beyond that provided by a time-tagged Cf spontaneous fission source. The main quantities obtained in the measurements were (1) the time distribution of the counts in a detector after a neutron fission in the Cf source or after the alpha detection coincident with the emission of a neutron from the DT generator (the equivalent of a pulsed neutron measurement with a randomly pulsed source) and (2) the time distribution of counts in one detector after a count in another detector (the equivalent of a two-detector Rossi-alpha measurement). Monte Carlo calculations using the MCNP-PoliMi coupled gamma-neutron transport code generally agreed with the measurement results except for some differences early in the fission chain decay process. The measurements that were performed with the HEU about 1 m above the floor were considerably affected by room return neutrons at times as early as 100 ns, and at times after 300 ns, a major portion of the time response was associated with the interaction of the HEU assemblies with the floor. This room-return effect increased with the size of the assembly because the larger assemblies subtend a larger solid angle to a neutron returning from the floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY 2014 Status Report: of Vibration Testing of Clad Fuel (M4FT-14OR0805033)

The DOE Used Fuel Disposition Campaign (UFDC) tasked Oak Ridge National Laboratory (ORNL) to investigate the behavior of light-water-reactor (LWR) fuel cladding material performance related to extended storage and transportation of UNF. ORNL has been tasked to perform a systematic study on UNF integrity under simulated normal conditions of transportation (NCT) by using the recently developed hot-cell testing equipment, Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT). To support the testing on actual high-burnup UNF, fast-neutron irradiation of pre-hydrided zirconium-alloy cladding in the High Flux Isotope Reactor (HFIR) at elevated temperatures will be used to simulate the effects of high-burnup on fuel cladding for help in understanding the cladding materials properties relevant to extended storage and subsequent transportation. The irradiated pre-hydrided metallic materials testing will generate baseline data to benchmark hot-cell testing of the actual high-burnup UNF cladding. More importantly, the HFIR-irradiated samples will be free of alpha contamination and can be provided to researchers who do not have hot cell facilities to handle highly contaminated high-burnup UNF cladding to support their research projects for the UFDC.t

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On Final Results From the Muon $g\mathrm{-}2$ Experiment at Fermilab

The Muon g-2 Experiment at Fermilab has measured the muon anomalous magnetic moment, a_mu, with unprecedented precision, leveraging a dataset from Runs 1 6 that is 21 times larger than its Brookhaven predecessor. This talk will present the experiment s final result, which serves as a benchmark for testing the Standard Model with high precision. The measurement was performed in a storage ring with a highly uniform magnetic field, where precise beam dynamics understanding is vital to determine the muon anomalous precession frequency. Key to this effort were advanced simulation tools including COSY INFINITY, precise fringe field modeling, and calculations of beam dynamics characteristics like tunes and chromaticity. We will conclude by exploring how the experiment's findings reshape our understanding of particle physics.

Valetov, Eremey [Michigan State U.]↗

Simulations of Zero Boiloff, Densification, and Solidification in a Large-Scale Liquid Hydrogen Tank

The current research utilizes an Energy of Fluid (EOF) approach to develop a finite volume-based Computation Fluid Dynamic (CFD) model to create a benchmark simulation of the densification of liquid hydrogen (LH2) in an experimental Integrated Refrigeration and Storage (IRAS) tank at the Kennedy Space Center (KSC). The computational code will incorporate the FLUENT pressure-based model with User Defined Functions (UDF) to implement the EOF model. The enhanced model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. Specifically, a convection term will be added to an already existing code for a more accurate simulation of LH2 densification. However, currently the research focuses on utilizing User Defined Scalars (UDS) with FLUENT to show the built-in solvers are as accurate as the written UDS. This will reduce the computational time down significantly by utilizing an already built in solver for the momentum equation. A custom UDF has been written to solve transient and steady state conduction, and results obtained using the UDF agree with results obtained using the built-in FLUENT solver. Currently, a convection UDF is being added and will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

Colin Philip Mahony↗

Current and Future Costs for Parabolic Trough and Power Tower Systems in the US Market: Preprint

NREL's Solar Advisor Model (SAM) is employed to estimate the current and future costs for parabolic trough and molten salt power towers in the US market. Future troughs are assumed to achieve higher field temperatures via the successful deployment of low melting-point, molten-salt heat transfer fluids by 2015-2020. Similarly, it is assumed that molten salt power towers are successfully deployedat 100MW scale over the same time period, increasing to 200MW by 2025. The levelized cost of electricity for both technologies is predicted to drop below 11 cents/kWh (assuming a 10% investment tax credit and other financial inputs outlined in the paper), making the technologies competitive in the marketplace as benchmarked by the California MPR. Both technologies can be deployed with largeamounts of thermal energy storage, yielding capacity factors as high as 65% while maintaining an optimum LCOE.

14 SOLAR ENERGY↗

Energy-efficient specialization of functional units in a Coarse-Grained Reconfigurable Array

Functional units provide the backbone of any spatial accelerator by providing the computing resources. The desire for having rich and expensive functional units is in tension with producing a regular and energy-efficient computing fabric. This paper explores the design trade-off between complex, universal functional units and simpler, limited functional units. We show that a modest amount of specialization reduces the area-delay-energy product of an optimized architecture to 0.86x a baseline architecture. Furthermore, we provide a design guideline that allows an architect to customize the contents of the computing fabric just by examining the profile of benchmarks within the application domains. Functional units are the core of compute-intensive spatial accelerators. They perform the computation of interest with support from local storage and communication structures. Ideally, the functional units will provide rich functionality, supporting operations ranging from simple addition, to fused multiply-adds, to advanced transcendental functions and domain specific operations like add-compare-select. However, the total opportunity cost to support the more complex operations is a function of the cost of the hardware, the rate of occurrence of the operation in the application domain, and the inefficiency of emulating the operation with simpler operators. Examples of operations that are typically emulated in spatial accelerators are division and trigonometric functions, which can be solved using table-lookup based algorithms and the CORDIC algorithm. One reason to avoid having direct hardware support for complex operations in a tiled architecture like a Coarse-Grained Reconfigurable Array (CGRA) is that the expensive hardware will typically need to be replicated in some or all of the architecture's tiles. Tiled architecture are designed such that their tiles are either homogeneous or heterogeneous. Homogeneous architectures are simpler to design but heterogeneous architectures can be more efficient. Generally, CGRAs try to support a rich set of operations with the smallest possible set of hardware devices.

97 MATHEMATICS AND COMPUTING↗

Progress and prospects of thermo-mechanical energy storage – A critical review

The share of electricity generated by intermittent renewable energy sources is increasing (now at 26% of global electricity generation) and the requirements of affordable, reliable and secure energy supply designate grid-scale storage as an imperative component of most energy transition pathways. The most widely deployed bulk energy storage solution is pumped-hydro energy storage (PHES), however, this technology is geographically constrained. Alternatively, flow batteries are location independent and have higher energy densities than PHES, but remain associated with high costs and low lifetimes, which highlights the importance of developing and utilizing additional larger-scale, longer-duration and long-lifetime energy storage alternatives. Here, we review a class of promising bulk energy storage technologies based on thermo-mechanical principles, which includes: compressed-air energy storage (CAES), liquid-air energy storage (LAES) and pumped-thermal electricity storage (PTES). The thermodynamic principles upon which these thermo-mechanical energy storage (TMES) technologies are based are discussed and a synopsis of recent progress in their development is presented, assessing their ability to provide reliable and cost-effective solutions. The current performance and future prospects of TMES systems are examined within a unified framework and a thermoeconomic analysis is conducted to explore their competitiveness relative to each other as well as when compared to PHES and flow battery systems. This includes carefully selected thermodynamic and economic methodologies for estimating the component costs of each configuration in order to provide a detailed and fair comparison at various system sizes. The analysis reveals that the technical and economic characteristics of TMES systems are such that, especially at higher discharge power ratings and longer discharge durations, they can offer promising performance (round-trip efficiencies higher than 60%) along with high lifetimes (> 30 years), low specific costs (often below 100 $/kWh), low ecological footprints and unique sector-coupling features compared to other storage options. TMES systems have significant potential for further progress and the thermoeconomic comparisons in this paper can be used as a benchmark for their future evolution.

25 ENERGY STORAGE↗

Bare, complex, and potassium-filled HEU oralloy annuli Benchmark experiments - 14103

Hundreds of critical experiments were constructed from Oak Ridge Alloy (oralloy) during the 1960's and 1970's at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purpose of these experiments included the evaluation of storage, casting, and handling limits and providing data for verification of calculation methods and cross sections for nuclear criticality safety applications. Recent contributions to the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) include bare, complex, and potassium-filled annuli comprising multiple stacked units of highly enriched uranium (HEU), ∼93.2 wt.% {sup 235}U, annuli, discs, and parallelepipeds. Prior contributions to the ICSBEP Handbook include bare (unreflected and unmoderated) cylinders; configurations of cylinders and annuli reflected with polyethylene, beryllium, or thin-graphite reflectors; GROTESQUE; and ORSphere. The newest contributions include a bare HEU 11-7 (11 inch outer diameter and 7 inch inner diameter) annulus oralloy-capped at the top and bottom; bare HEU 13-7, 15-7, and 15-9 annuli; bare HEU complex annuli consisting of a 15-9 annulus containing either an off-center 7-inch-diameter cylinder, 5 x 5 inch parallelepiped, or split parallelepiped; and an HEU 13-7 annulus containing either empty stainless steel cans or potassium-metal-filled cans. The purpose of this latter pair of annulus configurations was to test the fast neutron cross sections of potassium as it was a candidate for coolant in some early space power reactor designs. A total of nine new configurations were evaluated as acceptable benchmark experiment measurements. Additional ORCEF oralloy experiments have also been identified for future benchmark evaluation. (authors)

36 MATERIALS SCIENCE↗

Bare, Complex, and Potassium-Filled HEU Oralloy Annuli Benchmark Experiments

Hundreds of critical experiments were constructed from Oak Ridge Alloy (oralloy) during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purpose of these experiments included the evaluation of storage, casting, and handling limits and providing data for verification of calculation methods and cross sections for nuclear criticality safety applications. Recent contributions to the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) include bare, complex, and potassium-filled annuli comprising multiple stacked units of highly enriched uranium (HEU), ~93.2 wt.% 235U, annuli, discs, and parallelepipeds. Prior contributions to the ICSBEP Handbook include bare (unreflected and unmoderated) cylinders; configurations of cylinders and annuli reflected with polyethylene, beryllium, or thin-graphite reflectors; GROTESQUE; and ORSphere. The newest contributions include a bare HEU 11-7 (11 inch outer diameter and 7 inch inner diameter) annulus capped at the top and bottom; bare HEU 13-7, 15-7, and 15-9 annuli; bare HEU complex annuli consisting of a 15-9 annulus containing either an off-center 7-inch-diameter cylinder, 5 × 5 inch parallelepiped, or split parallelepiped; and an HEU 13-7 annulus containing either empty stainless steel cans or potassium-metal-filled cans. The purpose of this latter pair of annulus configurations was to test the fast neutron cross sections of potassium as it was a candidate for coolant in some early space power reactor designs. A total of nine new configurations were evaluated as acceptable benchmark experiment measurements. Additional ORCEF oralloy experiments have also been identified for future benchmark evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

U.S. Solar Photovoltaic BESS System Cost Benchmark Q1 2020 Report

NREL has been modeling U.S. solar photovoltaic (PV) system costs since 2009. This year, our report benchmarks costs of U.S. PV for residential, commercial, and utility-scale systems, with and without storage, built in the first quarter of 2020 (Q1 2020). The methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems and it models the capital costs and levelized cost of energy for such systems.

14 SOLAR ENERGY↗