Search NASA⌕ Search

SEARCH · Search NASA

Results for “stories”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Performance-based earthquake early warning for tall buildings

The ShakeAlert Earthquake Early Warning (EEW) system aims to issue an advance warning to residents on the West Coast of the United States seconds before the ground shaking arrives, if the expected ground shaking exceeds a certain threshold. However, residents in tall buildings may experience much greater motion due to the dynamic response of the buildings. Therefore, there is an ongoing effort to extend ShakeAlert to include the contribution of building response to provide a more accurate estimation of the expected shaking intensity for tall buildings. Currently, the supposedly ideal solution of analyzing detailed finite element models of buildings under predicted ground-motion time histories is not theoretically or practically feasible. The authors have recently investigated existing simple methods to estimate peak floor acceleration (PFA) and determined these simple formulas are not practically suitable. Instead, this article explores another approach by extending the Pacific Earthquake Engineering Research Center (PEER) performance-based earthquake engineering (PBEE) to EEW, considering that every component involved in building response prediction is uncertain in the EEW scenario. Additionally, while this idea is not new and has been proposed by other researchers, it has two shortcomings: (1) the simple beam model used for response prediction is prone to modeling uncertainty, which has not been quantified, and (2) the ground motions used for probabilistic demand models are not suitable for EEW applications. In this article, we address these two issues by incorporating modeling errors into the parameters of the beam model and using a new set of ground motions, respectively. We demonstrate how this approach could practically work using data from a 52-story building in downtown Los Angeles. Using the criteria and thresholds employed by previous researchers, we show that if peak ground acceleration (PGA) is accurately estimated, this approach can predict the expected level of human comfort in tall buildings.

58 GEOSCIENCES↗

Dataset from ORNL Flexible Research Platform (FRP)

The data comes from a two-story light commercial building which can be used to physically simulate light commercial buildings common in the nation's existing building stock. Based on a data collection plan, these measurements were performed for five different building operations. In the data set for each period, 98 data variables were selected and collected, in which 7 variables are weather data and the rest are all building and system operation data.

Cui, Borui↗

Building high throughput permissioned blockchain fabrics: challenges and opportunities

Since the introduction of Bitcoin---the first widespread application driven by blockchains---the interest in the design of blockchain-based applications has increased tremendously. At the core of these applications are consensus protocols that securely replicate client requests among all replicas, even if some replicas are Byzantine faulty. Unfortunately, these consensus protocols typically have low throughput, and this lack of performance is often cited as the reason for the slow wider adoption of blockchain technology. Consequently, many works focus on designing more efficient consensus protocols to increase throughput of consensus. We believe that this focus on consensus protocols only explains part of the story. To investigate this belief, we raise a simple question: Can a well-crafted system using a classical consensus protocol outperform systems using modern protocols? In this tutorial, we answer this question by diving deep into the design of blockchain systems. Further, we take an in-depth look at the theory behind consensus, which can help users select the protocol that best-fits their requirements. Finally, we share our vision of high-throughput blockchain systems that operate at large scales.

97 MATHEMATICS AND COMPUTING↗

AmeriFlux CA-Mer Ontario - Eastern Peatland, Mer Bleue

This is the AmeriFlux version of the carbon flux data for the site CA-Mer Ontario - Eastern Peatland, Mer Bleue. Site Description - The Mer Bleue peatland is primarily a large ombrotrophic bog located in the Ottawa River Valley, 10 km east of Ottawa, Ontario, Canada (45.40º N lat., 75.50º W long.). Mean annual temperature is 6.3ºC ranging from -10.5ºC in January to 21.0ºC in July. Mean annual precipitation is 943 mm, 268 mm of which falls during the summer months (Environment Canada; climate normals). Peat began to form approximately 8500 years ago, but the bog phase began later, about 6400 years ago (Lafleur et al., 2003; Richard, pers. comm.). The peat depth now ranges from 2 m at the edge to >5 m in the middle. Beaver ponds are found at the lagg margin of the bog. The bog is dominated by plant communities comprised primarily of the ericaceous shrubs Chamaedaphne calyculata (L.) Moench, Ledum groenlandicum Oeder, and Kalmia angustifolia L. Clusters of the deciduous shrub Vaccinium myrtilloides Michx. and the tufted sedge Eriophorum vaginatum L. are fairly common across the bog. The most common tree species found in the bog are Larix laricina (Duroi) K. Koch., Betula populifolia Marshall and Picea mariana (Miller) BSP occurring less frequently. In the poor fen, located to the north of the bog proper, community composition is primarily composed of the ericaceous shrubs listed above, including higher densities of K. angustifolia and Andromeda glaucophylla Link. The primary sedge in this area is Carex oligosperma Michx. All sites are dominated by an under story of bryophytes, mainly Sphagnum magellanicum Brid., Sphagnum capillifolium (Ehrh.) Hedw., and Polytrichum strictum Brid. in the bog, with Sphagnum papillosum Lindb., and Sphagnum fallax (Klinggr.) Klinggr. common in the wetter portions of the poor fen

Humphreys, Elyn↗

AmeriFlux US-DBk Berkeley Way West

This is the AmeriFlux version of the carbon flux data for the site US-DBk Berkeley Way West. Site Description - This tower is located in dowtown Berkeley, CA on the roof of Berkeley Way West, an 8 story building. The surrounding area is urbanized and includes a major commercial corridor, residential areas, and the UC Berkeley campus within 1 km of the site. Multi-unit residential construction activities took place near the site on an intermittent basis throughout tower operation.

Goldstein, Allen [UC Berkeley]↗

AmeriFlux US-DUF Denver Urban Field Station

This is the AmeriFlux version of the carbon flux data for the site US-DUF Denver Urban Field Station. Site Description - This site was established on a 25m freestanding former radio tower at the Forest Service's Rocky Mountain Research Station headquarters in Fort Collins, CO. The tower is situated next to a parking lot and several one and two story buildings. To the north and west is the campus of Colorado State University, and to the north and east is low density residential development. To the south and east are a busy intersection and rapid transit bus line, and to the south is green space surrounding the City of Fort Collins' Spring Creek Trail.

Frank, John [US Forest Service, Rocky Mountain Res↗

AmeriFlux FLUXNET-1F CA-Mer Ontario - Eastern Peatland, Mer Bleue

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Mer Ontario - Eastern Peatland, Mer Bleue. This is the FLUXNET version of the carbon flux data for the site CA-Mer Ontario - Eastern Peatland, Mer Bleue produced by applying the standard ONEFlux (1F) software. Site Description - The Mer Bleue peatland is primarily a large ombrotrophic bog located in the Ottawa River Valley, 10 km east of Ottawa, Ontario, Canada (45.40º N lat., 75.50º W long.). Mean annual temperature is 6.3ºC ranging from -10.5ºC in January to 21.0ºC in July. Mean annual precipitation is 943 mm, 268 mm of which falls during the summer months (Environment Canada; climate normals). Peat began to form approximately 8500 years ago, but the bog phase began later, about 6400 years ago (Lafleur et al., 2003; Richard, pers. comm.). The peat depth now ranges from 2 m at the edge to >5 m in the middle. Beaver ponds are found at the lagg margin of the bog. The bog is dominated by plant communities comprised primarily of the ericaceous shrubs Chamaedaphne calyculata (L.) Moench, Ledum groenlandicum Oeder, and Kalmia angustifolia L. Clusters of the deciduous shrub Vaccinium myrtilloides Michx. and the tufted sedge Eriophorum vaginatum L. are fairly common across the bog. The most common tree species found in the bog are Larix laricina (Duroi) K. Koch., Betula populifolia Marshall and Picea mariana (Miller) BSP occurring less frequently. In the poor fen, located to the north of the bog proper, community composition is primarily composed of the ericaceous shrubs listed above, including higher densities of K. angustifolia and Andromeda glaucophylla Link. The primary sedge in this area is Carex oligosperma Michx. All sites are dominated by an under story of bryophytes, mainly Sphagnum magellanicum Brid., Sphagnum capillifolium (Ehrh.) Hedw., and Polytrichum strictum Brid. in the bog, with Sphagnum papillosum Lindb., and Sphagnum fallax (Klinggr.) Klinggr. common in the wetter portions of the poor fen

Humphreys, Elyn [Carleton University]↗

National Critical Minerals Data Dashboard

The Critical Minerals (CM) Data Dashboard provides data-driven insights to help unlock the potential of conventional and unconventional CM resources in the United States. The dashboard focuses on 12 CM essential for producing zero-emission transportation and clean power technology. More information about these CM and potential resources is available in our CM Story Map. Dashboard data sets can be filtered geographically using the options provided along the top of the dashboard. Data sets can also be filtered by various attributes using the options in the expandable side panel on the left side of the screen. The data sets in this dashboard were compiled from multiple sources including the USGS, USEPA, OSMRE, and DHS., Users are encouraged to provide feedback/suggestions on the function and content of the dashboard, as well as any issues that may arise.

Conventional Resources↗

ASCENDS: Advanced data SCiENce toolkit for Non-Data Scientists

Recently, advances in machine learning and artificial intelligence have been playing more and more critical roles in a wide range of areas. For the last several years, industries have shown that how learning from data, identifying patterns and making decisions with minimal human intervention can be extremely useful to their business (e.g., image classification, recommending a product to a customer, finding friends in a social network, predicting customers actions, etc.). These success stories have been motivating scientists who study physics, chemistry, materials, medicine, and many other subjects, to explore a new pathway of utilizing machine learning techniques like regression and classification for their scientific activities. However, most existing machine learning tools, systems, and methodologies have been developed for programming experts but not for scientists (or any users) who have no or little knowledge of programming. ASCENDS is a toolkit that is developed to assist scientists (or any persons) who want to use their data for machine learning tasks, more specifically, correlation analysis, regression, and classification. ASCENDS does not require programming skills. Instead, it provides a set of simple but powerful CLI (Command Line Interface) and GUI (Graphic User Interface) tools for non-data scientists to be able to intuitively perform advanced data analysis and machine learning techniques. ASCENDS has been implemented by wrapping around opensource software including Keras, TensorFlow, and scikit-learn.

97 MATHEMATICS AND COMPUTING↗

Information transfer with a gravitating bath

Late-time dominance of entanglement islands plays a critical role in addressing the information paradox for black holes in AdS coupled to an asymptotic non-gravitational bath. A natural question is how this observation can be extended to gravitational systems. To gain insight into this question, we explore how this story is modified within the context of Karch-Randall braneworlds when we allow the asymptotic bath to couple to dynamical gravity. We find that because of the inability to separate degrees of freedom by spatial location when defining the radiation region, the entanglement entropy of radiation emitted into the bath is a time-independent constant, consistent with recent work on black hole information in asymptotically flat space. If we instead consider an entanglement entropy between two sectors of a specific division of the Hilbert space, we then find non-trivial time-dependence, with the Page time a monotonically decreasing function of the brane angle---provided both branes are below a particular angle. However, the properties of the entropy depend discontinuously on this angle, which is the first example of such discontinuous behavior for an AdS brane in AdS space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oscar Seborer: Father of the Soviet Atomic Bomb?

Seventy-five years after the end of World War II, atomic spies continue to captivate and revolt the American public. Theodore "Ted" Hall, Klaus Fuchs, and David Greenglass all committed espionage at Los Alamos during the war. It has also been conjectured that there was an unidentified spy known only by the code-name PERSEUS, but there is a growing consensus among scholars that PERSEUS never existed. However, in September 2019, historians Harvey Klehr and John Earl Haynes unmasked a fourth Los Alamos spy code-named GODSEND. His name: Oscar Seborer. When the New York Times reported the story of Seborer's treachery in November 2019, almost nothing was known about his work at the Laboratory. However, recently discovered documents in the National Security Research Center (NSRC) at Los Alamos National Laboratory (LANL) offer some clues as to what GODSEND may have stolen for Stalin.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Of Clouds and Craters: The History of U.S. Nuclear Weapons Testing

“Now!” With that word, the Atomic Age – and the era of nuclear weapons testing – dawned. The advent of World War II’s first irresistible weapon, which had been secretly tested in the New Mexico desert in July 1945, would help hasten the inevitable: complete victory for the Allies. Codenamed Trinity, the test was the first of over a thousand conducted by the United States between 1945 and 1992. Nuclear weapons would change future clashes as well. The looming Cold War, with roots stretching all the way back to 1917, was history’s first conflict between two, major nations armed with nuclear weapons. It is clear the existence of those weapons played an important role in maintaining a tenuous peace between the United States and the Soviet Union; it is also clear nuclear weapons testing played a prominent role in fueling both the arms race and the success of deterrence. Yet, the history of nuclear weapons testing is rarely remembered, even though nuclear tests have been performed in the very recent past. Of the estimated 2,000-plus nuclear tests ever performed, the U.S. is responsible for approximately half. This is the story of U.S. full-scale nuclear weapons testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preserving Manhattan Project historic sites

Beginning in 1943, Project Y – the code name for Los Alamos during World War II – transformed the isolated Pajarito Plateau. The sounds of construction equipment replaced the voices of the Los Alamos Ranch School boys and local homesteaders. Construction crews hurriedly built many structures on mesa tops and in the canyons of Los Alamos. Countless concerns flooded Manhattan Project staff, but designing structures to withstand the test of time was not one of them. The top-secret race to develop an atomic bomb before Nazi Germany was on and everyone felt the pressure. Over the next 75 years, some of the structures slumped into disrepair from exposure to the harsh northern New Mexico environment - concrete cracking and spalling, wood frames rotting. That’s where Los Alamos National Laboratory’s historic preservation team enters the Manhattan Project story.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Podcast commemorating Black History Month, LANL history Lab Historian talks with member of first Black family to live in Los Alamos

The Lab is commemorating Black History Month with events, stories, and this podcast conversation between Lab Historian Madeline Whitacre and Clayborne Carson Jr.Carson Jr. was a member of what is thought to be the first Black family to live in Los Alamos. He was a young boy when his father, Clayborne Carson Sr., accepted a job with the Atomic Energy Commission (AEC) as a security inspector in December 1947. The Carson family moved to Los Alamos shortly thereafter. Later, as a teenager, Carson Jr. worked at the Lab during the summers.

99 GENERAL AND MISCELLANEOUS↗