Search NASA⌕ Search

SEARCH · Search NASA

Results for “strain sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Wing Shape Sensing from Measured Strain

A new two-step theory is investigated for predicting the deflection and slope of an entire structure using strain measurements at discrete locations. In the first step, a measured strain is fitted using a piecewise least-squares curve fitting method together with the cubic spline technique. These fitted strains are integrated twice to obtain deflection data along the fibers. In the second step, computed deflection along the fibers are combined with a finite element model of the structure in order to interpolate and extrapolate the deflection and slope of the entire structure through the use of the System Equivalent Reduction and Expansion Process. The theory is first validated on a computational model, a cantilevered rectangular plate wing. The theory is then applied to test data from a cantilevered swept-plate wing model. Computed results are compared with finite element results, results using another strainbased method, and photogrammetry data. For the computational model under an aeroelastic load, maximum deflection errors in the fore and aft, lateral, and vertical directions are -3.2%, 0.28%, and 0.09%, respectively; and maximum slope errors in roll and pitch directions are 0.28% and -3.2%, respectively. For the experimental model, deflection results at the tip are shown to be accurate to within 3.8% of the photogrammetry data and are accurate to within 2.2% in most cases. In general, excellent matching between target and computed values are accomplished in this study. Future refinement of this theory will allow it to monitor the deflection and health of an entire aircraft in real time, allowing for aerodynamic load computation, active flexible motion control, and active induced drag reduction.

shape sensing↗

Wing Shape Sensing from Measured Strain

A new two-step theory is investigated for predicting the deflection and slope of an entire structure using strain measurements at discrete locations. In the first step, a measured strain is fitted using a piecewise least-squares curve fitting method together with the cubic spline technique. These fitted strains are integrated twice to obtain deflection data along the fibers. In the second step, computed deflection along the fibers are combined with a finite element model of the structure in order to interpolate and extrapolate the deflection and slope of the entire structure through the use of the System Equivalent Reduction and Expansion Process. The theory is first validated on a computational model, a cantilevered rectangular plate wing. The theory is then applied to test data from a cantilevered swept-plate wing model. Computed results are compared with finite element results, results using another strain-based method, and photogrammetry data. For the computational model under an aeroelastic load, maximum deflection errors in the fore and aft, lateral, and vertical directions are -3.2 percent, 0.28 percent, and 0.09 percent, respectively; and maximum slope errors in roll and pitch directions are 0.28 percent and -3.2 percent, respectively. For the experimental model, deflection results at the tip are shown to be accurate to within 3.8 percent of the photogrammetry data and are accurate to within 2.2 percent in most cases. In general, excellent matching between target and computed values are accomplished in this study. Future refinement of this theory will allow it to monitor the deflection and health of an entire aircraft in real time, allowing for aerodynamic load computation, active flexible motion control, and active induced drag reduction..

system equivalent reduction and expansion process↗

Wing Shape Sensing from Measured Strain

A new two step theory is investigated for predicting the deflection and slope of an entire structure using strain measurements at discrete locations. In the first step, a measured strain is fitted using a piecewise least squares curve fitting method together with the cubic spline technique. These fitted strains are integrated twice to obtain deflection data along the fibers. In the second step, computed deflection along the fibers are combined with a finite element model of the structure in order to extrapolate the deflection and slope of the entire structure through the use of System Equivalent Reduction and Expansion Process. The theory is first validated on a computational model, a cantilevered rectangular wing. It is then applied to test data from a cantilevered swept wing model.

system equivalent reduction and expansion process↗

Acceleration and Velocity Sensing from Measured Strain

A simple approach for computing acceleration and velocity of a structure from the strain is proposed in this study. First, deflection and slope of the structure are computed from the strain using a two-step theory. Frequencies of the structure are computed from the time histories of strain using a parameter estimation technique together with an autoregressive moving average model. From deflection, slope, and frequencies of the structure, acceleration and velocity of the structure can be obtained using the proposed approach. Simple harmonic motion is assumed for the acceleration computations, and the central difference equation with a linear autoregressive model is used for the computations of velocity. A cantilevered rectangular wing model is used to validate the simple approach. Quality of the computed deflection, acceleration, and velocity values are independent of the number of fibers. The central difference equation with a linear autoregressive model proposed in this study follows the target response with reasonable accuracy. Therefore, the handicap of the backward difference equation, phase shift, is successfully overcome.

shape sensing↗

Unsteady Aerodynamic Force Sensing from Strain Data

A simple approach for computing unsteady aerodynamic forces from simulated measured strain data is proposed in this study. First, the deflection and slope of the structure are computed from the unsteady strain using the two-step approach. Velocities and accelerations of the structure are computed using the autoregressive moving average model, on-line parameter estimator, low-pass filter, and a least-squares curve fitting method together with analytical derivatives with respect to time. Finally, aerodynamic forces over the wing are computed using modal aerodynamic influence coefficient matrices, a rational function approximation, and a time-marching algorithm.

aerodynamic load sensing↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Space Launch System: SLS Real Time Rollout Monitoring for MPCV

The NASA Space Launch System (SLS) rocket, Orion spacecraft, and Mobile Launcher (ML) are transported to Pad 39B from the Vehicle Assembly Building on a large, tracked vehicle known as the Crawler Transporter (CT). The CT is a holdover from the Apollo and Space Shuttle programs but has been extensively upgraded to accommodate the SLS. The Dynamic Rollout Test (DRT) on March 17, 2022 marked the first full rollout of the SLS and ML. Analysis indicated that loads and vibrations would be well below design limits, but out of an abundance of caution it was decided to monitor the response in real time during the rollout to assure that loads remained within predicted limits. This first rollout was outfitted with extensive test instrumentation such as accelerometers, pressure sensors, and strain gauges. This instrumentation remained in place following the integrated vehicle modal test and was being used for additional Operational Modal Analysis (OMA) during the rollout in addition to the real-time monitoring. This presentation discusses the specific loads and accelerations monitored during the rollout, how and why those responses were chosen, and how the system was implemented. Finally, a post-rollout loads reconstruction is used to assess the process and the analysis tools used for the rollout analysis.

SLS↗

Space Launch System Artemis I Ascent Loads Reconstruction Summary

On November 16, 2022, NASA successfully launched the Space Launch System (SLS) rocket and Orion spacecraft for the first SLS mission, Artemis 1. This first flight was outfitted with Developmental Flight Instrumentation (DFI) such as accelerometers, pressure sensors, and strain gauges. The DFI supports many post-flight activities, one of which is the ascent loads reconstruction effort. The integrated vehicle ascent loads spans both boost phase and Core phase and often produces the largest loads experienced by the vehicle during flight. One of the primary goals of the ascent loads reconstruction is to evaluate applicable Coupled Loads Analysis (CLA) design math models, assumptions, and analysis methodologies. To achieve this goal, all significant ascent subevents have been reconstructed through the use of flight data, reconstructed inputs, and existing CLA simulations. Resulting responses have been compared to available flight measurements. Additionally, reconstructed subevent loads were combined and compared to appropriate flight data and pre-flight predictions.

SLS↗

Optical Fiber Strain Instrumentation for High Temperature Aerospace Structural Monitoring

The objective of the program is the development and laboratory demonstration of sensors based on silica optical fibers for measurement of high temperature strain for aerospace materials evaluations. A complete fiber strain sensor system based on white-light interferometry was designed and implemented. An experiment set-up was constructed to permit testing of strain measurement up to 850 C. The strain is created by bending an alumina cantilever beam to which is the fiber sensor is attached. The strain calibration is provided by the application of known beam deflections. To ensure the high temperature operation capability of the sensor, gold-coated single-mode fiber is used. Moreover, a new method of sensor surface attachment which permits accurate sensor gage length determination is also developed. Excellent results were obtained at temperatures up to 800-850 C.

Wang, A.↗

Longitudinally Jointed Edge-wise Compression Honeycomb Composite Sandwich Coupon Testing and FE Analysis: Three Methods of Strain Measurement, and Comparison

Three means (i.e., typical foil strain gages, fiber optic sensors, and a digital image correlation (DIC) system) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The Pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The strain gages and fiber optic sensors were bonded on the specimen at locations with nearly the same strain values, as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the DIC system are justified. The test article was loaded to failure (at approximately 38 kips), at the strain value of approximately 10,000mu epsilon As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the strain gage and DIC data, and also will be compared with FEA predictions.

Farrokh, Babak↗

Strain Insensitive Optical Phase Locked Loop

An apparatus is provided to allow for quasi distributed sensing of strain within a test object. Strain insensitive fiber is used to deliver a light signal to a strain sensitive fiber in an optical phase locked loop sensor configuration. The use of strain insensitive delivery fiber allows for non-integrated measurements of strain without the use of expensive electronics such as those employed in ODTR techniques. The novelty of the present invention lies in the use of strain insensitive multimode fiber. The inventors had previously developed a similar sensor with strain insensitive fiber, however it was restricted to the use of single or few mode fibers. The use of an optical phase locked loop arrangement allows for the use of multimode strain insensitive fiber.

Egalon, Claudio Oliviera↗

Reusable Cryogenic Tank VHM Using Fiber Optic Distributed Sensing Technology

The reusable oxygen and hydrogen tanks are key systems for both the X-33 (sub-scale, sub-orbital technology demonstrator) and the commercial Reusable Launch Vehicle (RLV). The backbone of the X-33 Reusable Cryogenic Tank Vehicle Health Management (VHM) system lies in the optical network of distributed strain temperature and hydrogen sensors. This network of fiber sensors will create a global strain and temperature map for monitoring the health of the tank structure, cryogenic insulation, and Thermal Protection System. Lockheed Martin (Sanders and LMMSS) and NASA Langley have developed this sensor technology for the X-33 and have addressed several technical issues such as fiber bonding and laser performance in this harsh environment.

Bodan-Sanders, Patricia↗

Fiber optic strain measurements in filament-wound graphite-epoxy tubes containing embedded fibers

Filament-wound graphite-epoxy tubes fabricated with embedded fiber optic sensors were tested at NASA Langley Research Center to evaluate the feasibility of monitoring stress with a fiber optic technique. Resistance strain gauges were attached to the tubes to measure strain at four locations along the tubes. Both static and dynamic strain measurements were made with an excellent agreement between the embedded fiber optic strain sensor and the strain gauges. The results indicate that fiber optic sensors embedded in composites may be useful as the sensing component of smart structures.

Rogowski, R. S.↗

Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. The first task was to measure finger joint angles inside space suit gloves. A preliminary survey identified three potential systems which could be used in the proposed study. In response to the current market situation, a glove for measuring the positions of the hand inside a space suit has been developed. A prototype of the glove has been constructed to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. Along gage is used to average the strain generated in the sensor due to bending This average strain produces an output signal proportional to the angle of the bend. The force sensor consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. The resistance of the ink is sensitive to pressure.

Strauss, Alvin M.↗

JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. We have constructed a prototype of the glove to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. A long gage is used to average the strain generated in the sensor due to bending. This average strain produces an output signal proportional to the angle of the bend. The force sensor, FSR, is manufactured by Interlink. It consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. When the electrode makes contact, current flows through the conductive ink. The resistance of the ink pad is sensitive to pressure. We have also developed circuits for exciting and measuring the sensors. The current version requires a single sided twelve volt power supply which is one inch long and 0.4 inches in diameter.

Strauss, Alvin M.↗