Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Twin Jet

Many subsonic and supersonic vehicles in the current fleet have multiple engines mounted near one another. Some future vehicle concepts may use innovative propulsion systems such as distributed propulsion which will result in multiple jets mounted in close proximity. Engine configurations with multiple jets have the ability to exploit jet-by-jet shielding which may significantly reduce noise. Jet-by-jet shielding is the ability of one jet to shield noise that is emitted by another jet. The sensitivity of jet-by-jet shielding to jet spacing and simulated flight stream Mach number are not well understood. The current experiment investigates the impact of jet spacing, jet operating condition, and flight stream Mach number on the noise radiated from subsonic and supersonic twin jets.

Henderson, Brenda↗

Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source

A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20–40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, −2 to −4 kV, and 0 kV, respectively. The total ion beam current of 30–40 mA is recorded on Faraday cup at 40 keV of beam energy at 600–1000 W of microwave power, 800–1000 G axial magnetic field and (1.2–3.9) × 10{sup −3} mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.

43 PARTICLE ACCELERATORS↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗

The Effect of Hydrogen Bonding in Enhancing the Ionic Affinities of Immobilized Monoprotic Phosphate Ligands

Environmental remediation requires ion-selective polymers that operate under a wide range of solution conditions. In one example, removal of trivalent and divalent metal ions from waste streams resulting from mining operations before they enter the environment requires treatment at acidic pH. The monoethyl ester phosphate ligands developed in this report operate from acidic solutions. They have been prepared on polystyrene-bound ethylene glycol, glycerol, and pentaerythritol, and it is found that intra-ligand hydrogen bonding affects their metal ion affinities. The affinity for a set of trivalent (Fe(III), Al(III), La(III), and Lu(III)) and divalent (Pb(II), Cd(II), Cu(II), and Zn(II)) ions is greater than that of corresponding neutral diethyl esters and phosphonic acid. In an earlier study, hydrogen bonding was found important in determining the metal ion affinities of immobilized phosphorylated polyol diethyl ester coordinating ligands; their Fourier transform infrared (FTIR) band shifts indicated that the basicity of the phosphoryl oxygen increased by hydrogen bonding to auxiliary –OH groups on the neighboring polyol. The same mechanism is operative with the monoprotic resins along with hydrogen bonding to the P–OH acid site. This is reflected in the FTIR spectra: the neutral phosphate diethyl ester resins have the P=O band at 1265 cm -1 while the monoethyl ester resins have the band shifted to 1230 cm -1 ; hydrogen bonding is further indicated by the broadness of this region down to 900 cm -1 . Of the polymers studied, monoprotic pentaerythritol has the highest metal ion affinities.

36 MATERIALS SCIENCE↗

System with a direct contact desublimating heat exchanger and temperature regulation

A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through a plurality of discrete unit operations, and the unit operations may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the unit operations. The parallel streams which are of a similar temperature may be mixed to form a warm stream and a cool stream. The warm stream and the cool stream may be sent to a mixing chamber. A mixed stream of substantially uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.

42 ENGINEERING↗

Treatment of Foreign Radioactive Waste at the BELGOPROCESS Plant - 19345

Belgium has used a large number of nuclear technologies during the last 60 years. Power generation, reprocessing, fuel fabrication, isotope production and research activities have produced a large variety of radioactive waste streams. BELGOPROCESS is the operator of the centralised waste treatment facilities located in the Campine region in Flanders. Over the years BELGOPROCESS has developed the know-how and facilities to treat each one of these waste streams. BELGOPROCESS is a subsidiary of NIRAS, the governmental institution responsible for the safe management of radioactive waste and enriched fissile materials in Belgium. A number of these waste streams are only produced during a short period of time. After processing the existing stockpile the treatment facility is put into operational standby and eventually prepared for decommissioning. In order to treat the stockpile of some types of legacy waste within an acceptable time frame, the treatment facilities needed to be designed at a certain treatment capacity. Since the majority of the legacy waste is processed nowadays, a significant amount of treatment capacity becomes available. In June 2006 the Belgian government decided that this know-how and facilities should become available to foreign waste producers. This would allow BELGOPROCESS to fill up the available capacity of its facilities and consequently lower the cost for the Belgian waste producers. Nowadays two facilities are open to accept foreign radioactive waste. The CILVA-facility can be used for sorting, cutting, incineration, precompaction, supercompaction and cementation of low level solid waste. The PAMELA-facility - a former vitrification plant - can be used for the treatment of medium level and alpha-bearing waste. In this paper we will discuss the technical characteristics of the CILVA-incinerator and a showcase for the treatment of foreign waste at our facilities. In 2016 BELGOPROCESS started a cooperation with MATE-FIN for the incineration of low level burnable waste from the Cernavoda NPP in Romania. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility Study – Using a Solar Evaporator to Reduce the Metalworking Fluid (MWF) Waste Stream

A solar evaporator was designed, built, and operated to reduce the water-based metalworking fluid waste stream. The evaporator was setup in Waste Management’s barrel lot inside one of the confinement areas. The unit processed three batches of waste fluid during the prototype testing. Initial tests removed 13% of the fluid waste stream. Subsequent modifications to the collector improved the rate to almost 20% per week. Evaluation of the risk during operation showed that even a small spill when associated with precipitation, and the unit placement within a confinement area, gave it the potential to contaminate more fluid that what it could save.

14 SOLAR ENERGY↗

Soft Decision Analyzer and Method

A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.

Steele, Glen F.↗

Soft Decision Analyzer and Method

A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.

Steele, Glen F.↗

Soft decision analyzer and method

A soft decision analyzer system is operable to interconnect soft decision communication equipment and analyze the operation thereof to detect symbol wise alignment between a test data stream and a reference data stream in a variety of operating conditions.

Steele, Glen F.↗

The Total-Pressure Recovery and Drag Characteristics of Several Auxiliary Inlets at Transonic Speeds

Several flush and scoop-type auxiliary inlets have been tested for a range of Mach numbers from 0.55 to 1.3 to determine their transonic total-pressure recovery and drag characteristics. The inlet dimensions were comparable with the thickness of the boundary layer in which they were tested. Results indicate that flush inlets should be inclined at very shallow angles with respect to the surface for optimum total-pressure recovery and drag characteristics. Deep, narrow inlets have lower drag than wide shallow ones at Mach numbers greater than 0.9 but at lower Mach numbers the wider inlets proved superior. Inlets with a shallow approach ramp, 7 deg, and diverging ramp walls which incorporated boundary-layer bypass had lower drag than any other inlet tested for Mach numbers up to 1.2 and had the highest pressure recovery of all of the flush inlets. The scoop inlets, which operated in a higher velocity flow than the flush inlets, had higher drag coefficients. Several of these auxiliary inlets projected multiple, periodic shock waves into the stream when they were operated at low mass-flow ratios.

Dennard, John S.↗

SUBTASK 2.19 – OPERATIONAL FLEXIBILITY OF CO2 TRANSPORT AND STORAGE

Carbon dioxide (CO2) is produced in large quantities during electricity generation and by industrial processes. These CO2 streams vary in terms of both composition and mass flow rate, sometimes substantially. The impact of a varying CO2 stream on pipeline and storage operation is not fully understood in terms of either operability or infrastructure robustness. This study was performed to summarize basic background from the literature on the topic of operational flexibility of CO2 transport and storage, but the primary focus was on compiling real-world lessons learned about flexible operation of CO2 pipelines and storage from both large-scale field demonstrations and commercial operating experience. Modeling and pilot-scale results of research in this area were included to illustrate some of the questions that exist relative to operation of carbon capture and storage (CCS) projects with variable CO2 streams. It is hoped that this report’s real-world findings provide readers with useful information on the topic of transport and storage of variable CO2 streams. The real-world results were obtained from two sources. The first source consisted of five full-scale, commercial transport–storage projects: Sleipner, Snøhvit, In Salah, Weyburn, and Illinois Basin–Decatur. These scenarios were reviewed to determine the information that is available about CO2 stream variability/intermittency on these demonstration-scale projects. The five projects all experienced mass flow variability or an interruption in flow. In each case, pipeline and/or injection engineers were able to accommodate any issues that arose. Significant variability in composition has not been an issue at these five sites. The second source of real- world results was telephone interviews conducted with experts in CO2 pipeline transport, injection, and storage during which commercial anecdotal information was acquired to augment that found during the literature search of the five full-scale projects. The experts represented a range of disciplines and hailed from North America and Europe. Major findings of the study are that compression and transport of CO2 for enhanced oil recovery (EOR) purposes in the United States has shown that impurities are not likely to cause transport problems if CO2 stream composition standards are maintained and pressures are kept at 10.3 MPa or higher. Cyclic, or otherwise intermittent, CO2 supplies historically have not impacted in-field distribution pipeline networks, wellbore integrity, or reservoir conditions. The U.S. EOR industry has demonstrated that it is possible to adapt to variability and intermittency in CO2 supply through flexible operation of the pipeline and geologic storage facility. This CO2 transport and injection experience represents knowledge that can be applied in future CCS projects. A number of gaps in knowledge were identified that may benefit from future research and development, further enhancing the possibility for widespread application of CCS. This project was funded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the IEA Greenhouse Gas R&D Programme.

Jensen, Melanie↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Preparation and evaporation of Hanford Waste treatment plant direct feed low activity waste effluent management facility simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Melter Off-Gas Condensate, LMOGC) from the off-gas system. The baseline plan for disposition of this stream during full WTP operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation, and recycled to the LAW vitrification facility. However, during the Direct Feed LAW (DFLAW) scenario, planned disposition of this stream involves concentrating the condensate in a new evaporator at the Effluent Management Facility (EMF) and returning it to the LAW melter. The LMOGC stream will contain components, e.g. halides and sulfates, that are volatile at melter temperatures, have limited solubility in glass waste forms, and present a material corrosion concern. Because this stream will recycle within WTP, these components are expected to accumulate in the LMOGC stream, exacerbating their impact on the number of LAW glass containers that must be produced. Diverting the stream reduces the halides and sulfates in the glass and is a key objective of this program. In order to determine the disposition path, it is key to experimentally determine the fate of contaminants. To do this, testing is needed to account for the buffering chemistry of the components, determine the achievable evaporation end point, identify insoluble solids that form, determine the formation and distribution of key regulatoryimpacting constituents, and generate an aqueous stream that can be used in testing of the subsequent immobilization step. This overall program examines the potential treatment and immobilization of the LMOGC stream to enable alternative disposal. The objective of this task was to (1) prepare a simulant of the LAW Melter Off-gas Condensate expected during DFLAW operations, (2) demonstrate evaporation in order to predict the final composition of the effluents from the EMF evaporator to aid in planning for their disposition, and (3) generate concentrated evaporator bottoms for use in immobilization testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Distribution During Evaporation of Hanford Waste Treatment Plant Direct Feed Low Activity Waste Effluent Management Facility Simulant

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream from the off-gas system. The baseline plan for disposition of this stream during full WTP operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation, and recycled to the LAW vitrification facility. However, during the Direct Feed LAW (DFLAW) scenario, planned disposition of this stream involves concentrating the condensate in a new evaporator at the Effluent Management Facility (EMF) and returning it to the LAW melter. The LAW melter condensate stream will contain components, e.g. halides and sulfates, that are volatile at melter temperatures, have limited solubility in glass waste forms, and present a material corrosion concern. Further, some minor constituents in the melter condensate, such as volatile organic compounds and iodine, have been found to be at least partially volatile in the EMF. The condensate from the EMF will be sent to the Hanford Effluent Treatment Facility (ETF). The presence of some recalcitrant organics and iodine, as 129I, are expected to be problematic in the ETF. In order to better predict and prepare for the distribution of organics and 129I in the flowsheet, it is key to understand their chemistry and experimentally determine their behavior during evaporation. To do this, modeling and testing were performed to examine the speciation of iodine under relevant conditions, as well as determine partitioning of iodine and the organics in the EMF evaporator. This overall program examines the potential treatment and immobilization of the LAW melter condensate stream to enable alternative disposal. The objective of this task was to (1) perform modeling to determine the speciation and fate of iodine species, (2) prepare a simulant of the LAW Melter Off-gas Condensate expected during DFLAW operations, (3) spike in the key volatile organics and non-radioactive iodine, and (4) demonstrate evaporation in order to predict the final composition of the effluents from the EMF evaporator to aid in planning for their disposition. The results of the modeling of iodine speciation indicate that the iodine is expected to remain in the evaporator pot as iodide and possibly iodate ion if the pH is raised to 11.5-12, which is the planned condition for the EMF. Experimental testing confirmed that the iodide remained in the evaporator concentrate and was below detection limits in all condensate and knock-out pot samples, indicating it was not volatile. The organic nitrile compounds that were added to the simulant were absent from the evaporator feed solution, either lost through evaporation, or more likely, decomposition. The acetone and methylene chloride were below the target values in the feed and condensate samples, and were presumably lost to evaporation or decomposition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Design of a Downstream Processing System for Protein Production in Space

Biomanufacturing is a promising technology to convert in situ resources into essential products including enzymes, therapeutics, biopolymers and other chemicals required to support deep-space missions that may not be easily supplied or produced by alternative means. In addition to the biomass production operations, vital down-stream steps including biomass harvesting/concentration, cell lysis, protein capture and purification are needed to produce an application-ready product. Commercially available terrestrial processes commonly require complex, heavy equipment and highly trained operators, which are not practical in deep space environments. In this work, we aim to identify approaches required to produce an intracellular, His-tagged recombinant enzyme using E. coli at 1 L production scales within the constraints of a deep-space mission as a model use-case scenario. Based on extensive literature review and commercially available products, we identified candidate technologies and products that could be integrated for deep space biomanufacturing. Different preliminary designs were then compared in terms of total system impacts on up-mass, processing time, and consumables required. Our analysis indicated that a biomass concentrator would significantly reduce the processing time and consumables required for the overall system without a large increase in the total mass. We also identified viable technologies for other steps such as cell lysis and protein purification. Predictions from our trade study will be validated in the laboratory by testing the most promising products with the results used to optimize the design. This research will help transfer technology that is well developed on Earth to a space-ready format to produce biological products from a wide variety of microorganisms that can support deep-space missions.

Biomanufacturing↗

Cooling process and system for dry cooling power plants

A seasonal process that captures stores and uses water in an ambient temperature-dependent manner to improve the efficiency of a natural gas power plant, comprising: (a) providing a natural gas power plant, the natural gas power plant having a flue gas stream, a cooling tower, and a gas turbine; (b) providing a water collection system; (c) providing a water storage facility; wherein the flue gas stream comprises uncondensed water vapor; wherein the water collection system is operably connected to the flue gas stream and the flue gas stream is directed to flow, at least in part, into the water collection system; wherein the water collection system is operably connected to the water storage facility; wherein the water storage facility is operably connected to the cooling tower and the water storage facility is operably connected to the gas turbine; wherein the process comprises the following steps of condensing flue gas water or using water that has been condensed from the flue gas stream based on outdoor ambient dry bulb temperature: (I) Only condensing water from the flue gas stream to produce a condensed water stream if outdoor ambient dry bulb temperature is less than 85° F.; (II) Only using condensed water to spray cool the cooling tower if outdoor ambient dry bulb temperature is at least 85° F.; (III) Only using condensed water to fog cool the gas turbine if outdoor ambient dry bulb temperature is at least 55° F.; wherein condensed water that is not immediately used to cool the cooling tower or to fog cool the gas turbine is stored in the water storage facility; and wherein the process uses a total amount of water on an annual basis to cool the cooling tower and to fog cool the gas turbine that does not exceed the annual amount of water condensed from the flue gas stream. Optionally, the process has a cooling tower that is a dry cooling tower and condensed water is used to spray cool the dry cooling tower, or the cooling tower is a wet cooling tower, or the cooling tower is a hybrid wet-dry cooling tower. The process may further comprise a water collection system having a three stage desiccant cycle and a calcium chloride desiccant that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condensing column that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condenser and a rotating wheel heat exchanger that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure, or further comprises plastic piping or plastic vessels. The coefficient of performance for the cooling process is optionally at least 2.0.

Srinivas, Girish↗

A machine learning approach for clinker quality prediction and nonlinear model predictive control design for a rotary cement kiln

Abstract Cement manufacturing is energy‐intensive (5Gj/t) and comprises a significant portion of the energy footprint of concrete systems. Incorporating modern monitoring, simulation and control systems will allow lower energy use, lower environmental impact, and lower costs of this widely used construction material. One of the goals of the CESMII roadmap project on the Smart Manufacturing of Cement included developing an analytical process model for clinker quality that includes the chemistry of the kiln feed and accounts for critical process variables. This predictive model will be used in nonlinear model predictive control system designed to significantly reduce process energy use while maintaining or improving product quality. In the cement manufacturing plant used in this study, the kiln feed (meal) is tested every 12 h and used to estimate the mineral composition of the cement kiln output (clinker) using the stoichiometry‐based Bogue's model and the expertise of the plant operators. During kiln operation, kiln output (clinker) is sampled and tested every 2 h to measure its chemical and mineral composition. The predicted and measured values of the clinker composition are used by the plant operators to adjust the kiln input stream and the production process characteristics to maintain stable operation and uniform product quality. However, the time delay between prediction and testing, along with inaccuracies inherent in the Bogue's model have made any process changes designed to minimize energy use problematic, especially in‐light of potential clinker quality issues that process changes often pose. A new analytical model that integrates quality information and process operation information has been developed from data collected from 2 years of production from an operating cement facility. To make the model fuel‐type‐independent, consumed heat energy was computed in the model instead of fuel type and amount. A Feedforward Network was trained and tailored from collected data. Many data‐based simulations were conducted to quantitatively evaluate the proposed model and the 5‐fold cross‐validation procedure was used to test the models. The resulting predictive model was shown to have a low root mean square error (MSE) with respect to the estimated clinker mineral composition compared to that using the industry standard “Bogue’ model”. The end goal of this work was to develop a single machine learning tool that allows the use of quality control data and process control variables to improve energy efficiency of the process in a continuous fashion. The proposed nonlinear model predictive control system (NMPC) can generate predicted kiln production characteristics based on manipulated variables in manner that accurately follows the target product quality values. Simulation results also show that the proposed model produced accurate predictions of kiln outputs that fell within the required constraints, while manipulating control variables within typical operational ranges.

Ali, Asem M.↗