Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

Two crucial areas in the development of the high resolution EUV spectroheliometer are the elastically deformable toroidal diffraction grating and the open-structure imaging pulse counting detector system. The optical performance of a high frequency toroidal grating at EUV wavelengths was verified with a 3600 groove/mm master grating on a spherical concave blank. An open-structure (256 x 1024) pixel, multi-anode microchannel array was developed and tested as a pulse counting detector system. These two systems verify the proof of concept of the spectroheliometer design.

Timothy, J. G.↗

Building Atomic and Plasmonic Devices via Electron Beams: from Desired Structures to Desired Properties

The evolution of the aberration correction in Scanning Transmission Electron Microscopy (STEM) has enabled multiple advances including high-resolution structural imaging, pm-level position detection of atomic columns, and ~3-5 mV resolution electron energy loss spectroscopy of the chemical and physical functionalities. These developments have further enabled the precise manipulation of the atomic structure of materials, including removal and formation of atomic planes in 3D materials, controlled atomic motion, and even direct atomic assembly of homo- and heteroatomic artificial molecules. Here, we will discuss several recent advances in STEM-EELS automated experiments as applied to quantum and nanoplasmonic systems.

42 ENGINEERING↗

Temperature-dependent quantitative 3{omega} scanning thermal microscopy: Local thermal conductivity changes in NiTi microstructures induced by martensite-austenite phase transition

We develop the theoretical description of 3{omega} signals from the resistive Wollaston thermal probe (ThP) of a scanning thermal microscope (SThM) in terms of an equivalent low-pass filter. The normalized amplitude and phase frequency spectra are completely characterized by a single parameter, the crossover frequency f{sub c}(k) depending on the sample thermal conductivity k. The application concerns polycrystalline NiTi shape memory alloy microstructured by focused Ga ion beam milling and implantation. The calibration of the ThP combined with a novel two-step normalization procedure allowed quantitative exploitation of 3{omega} signal variations as small as -1.75% in amplitude and 0.60 deg. in phase upon heating the sample from room temperature to 100 deg. C. This corresponds to k increase of 23.9% that is consistent with the expected thermal conductivity variation due to martensite-austenite structural phase transition. To our knowledge this is for the first time that SThM 3{omega} phase information is used quantitatively as well. The static, calibrated 3{omega} measurements are complementary to 3{omega} SThM images of the patterned sample surface. The local SThM measurement of temperature-dependent thermal conductivity opens the possibility to imaging structural phase transitions at submicron scale.

36 MATERIALS SCIENCE↗

Multimodal Imaging of Alzheimer Pathophysiology in the Brain's Default Mode Network

The spatial correlations between the brain's default mode network (DMN) and the brain regions known to develop pathophysiology in Alzheimer's disease (AD) have recently attracted much attention. In this paper, we compare results of different functional and structural imaging modalities, including MRI and PET, and highlight different patterns of anomalies observed within the DMN. Multitracer PET imaging in subjects with and without dementia has demonstrated that [C-11]PIB- and [F-18]FDDNP-binding patterns in patients with AD overlap within nodes of the brain's default network including the prefrontal, lateral parietal, lateral temporal, and posterior cingulate cortices, with the exception of the medial temporal cortex (especially, the hippocampus) where significant discrepancy between increased [F-18]FDDNP binding and negligible [C-11]PIB-binding was observed. [F-18]FDDNP binding in the medial temporal cortex—a key constituent of the DMN—coincides with both the presence of amyloid and tau pathology, and also with cortical areas with maximal atrophy as demonstrated by T1-weighted MR imaging of AD patients.

Shin, Jonghan↗

IMAGE ANALYSIS ALGORITHMS FOR DUAL MODE IMAGING SYSTEMS

The level of detail discernable in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes where information barriers are mandatory. However, if a balance can be struck between sufficient information barriers and feature extraction to verify or identify objects of interest, imaging may significantly advance verification efforts. This paper describes the development of combined active (conventional) radiography and passive (auto) radiography techniques for imaging sensitive items assuming that comparison images cannot be furnished. Three image analysis algorithms are presented, each of which reduces full image information to non-sensitive feature information and ultimately is intended to provide only a yes/no response verifying features present in the image. These algorithms are evaluated on both their technical performance in image analysis and their application with or without an explicitly constructed information barrier. The first algorithm reduces images to non-invertible pixel intensity histograms, retaining only summary information about the image that can be used in template comparisons. This one-way transform is sufficient to discriminate between different image structures (in terms of area and density) without revealing unnecessary specificity. The second algorithm estimates the attenuation cross-section of objects of known shape based on transition characteristics around the edge of the object’s image. The third algorithm compares the radiography image with the passive image to discriminate dense, radioactive material from point sources or inactive dense material. By comparing two images and reporting only a single statistic from the combination thereof, this algorithm can operate entirely behind an information barrier stage. Together with knowledge of the radiography system, the use of these algorithms in combination can be used to improve verification capability to inspection regimes and improve and substantially increase the likelihood of detecting material diversion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolving Electrode Morphology’s Impact on Platinum Group Metal-Free Cathode Performance Using Nano-CT of 3D Hierarchical Pore and Ionomer Distribution

This paper reports on the characterization of polymer electrolyte fuel cell (PEFC) cathodes featuring a platinum group metal-free (PGM-free) catalyst using nano-scale resolution X-ray computed tomography (nano-CT) and morphological analysis. PGM-free PEFC cathodes have gained significant interest in the past decade since they have the potential to dramatically reduce PEFC costs by eliminating the large platinum (Pt) raw material cost. However, several challenges remain before they are commercially viable. Since these catalysts have lower volumetric activity, the PGM-free cathodes are thicker and are subject to increased gas and proton transport resistances that reduce the performance. To better understand the efficacy of the catalyst and improve electrode performance, a detailed understanding the correlation between electrode fabrication, morphology, and performance is crucial. In this work, the pore/solid structure and the ionomer distribution was resolved in three dimensions (3D) using nano-CT for three PGM-free electrodes of varying Nafion® loading. The associated transport properties were evaluated from pore/particlescale simulations within the nano-CT imaged structure. These characterizations are then used to elucidate the microstructural origins of the dramatic changes in fuel cell performance with varying Nafion® ionomer loading. We show that this is primarily a result of distinct changes in ionomer’s spatial distribution. The significant impact of electrode morphology on performance highlights the importance of PGM-free electrode development in concert with efforts to improve catalyst activity and durability.

42 ENGINEERING↗

WE-G-204-06: Grid-Line Artifact Minimization for High Resolution Detectors Using Iterative Residual Scatter Correction

Purpose: Anti-scatter grid-line artifacts are more prominent for high-resolution x-ray detectors since the fraction of a pixel blocked by the grid septa is large. Direct logarithmic subtraction of the artifact pattern is limited by residual scattered radiation and we investigate an iterative method for scatter correction. Methods: A stationary Smit-Rοntgen anti-scatter grid was used with a high resolution Dexela 1207 CMOS X-ray detector (75 µm pixel size) to image an artery block (Nuclear Associates, Model 76-705) placed within a uniform head equivalent phantom as the scattering source. The image of the phantom was divided by a flat-field image obtained without scatter but with the grid to eliminate grid-line artifacts. Constant scatter values were subtracted from the phantom image before dividing by the averaged flat-field-with-grid image. The standard deviation of pixel values for a fixed region of the resultant images with different subtracted scatter values provided a measure of the remaining grid-line artifacts. Results: A plot of the standard deviation of image pixel values versus the subtracted scatter value shows that the image structure noise reaches a minimum before going up again as the scatter value is increased. This minimum corresponds to a minimization of the grid-line artifacts as demonstrated in line profile plots obtained through each of the images perpendicular to the grid lines. Artifact-free images of the artery block were obtained with the optimal scatter value obtained by this iterative approach. Conclusion: Residual scatter subtraction can provide improved grid-line artifact elimination when using the flat-field with grid “subtraction” technique. The standard deviation of image pixel values can be used to determine the optimal scatter value to subtract to obtain a minimization of grid line artifacts with high resolution x-ray imaging detectors. This study was supported by NIH Grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

OBSCURED STARBURST ACTIVITY IN HIGH-REDSHIFT CLUSTERS AND GROUPS

Using Spitzer-Multiband Imaging Photometer 24 {mu}m imaging and extensive Keck spectroscopy, we examine the nature of the obscured star-forming population in three clusters and three groups at z {approx} 0.9. These six systems are the primary components of the Cl1604 supercluster, the largest structure imaged by Spitzer at redshifts approaching unity. We find that the average density of 24 {mu}m detected galaxies within the Cl1604 clusters is nearly twice that of the surrounding field and that this overdensity scales with the cluster's dynamical state. The 24 {mu}m bright members often appear optically unremarkable and exhibit only moderate [O II] line emission due to severe obscuration. Their spatial distribution suggests that they are an infalling population, but an examination of their spectral properties, morphologies, and optical colors indicates that they are not simply analogs of the field population that have yet to be quenched. Using stacked composite spectra, we find that the 24 {mu}m detected cluster and group galaxies exhibit elevated levels of Balmer absorption compared with galaxies undergoing normal, continuous star formation. A similar excess is not observed in field galaxies with equivalent infrared luminosities, indicating a greater fraction of the detected cluster and group members have experienced a burst of star formation in the recent past compared to their counterparts in the field. Our results suggest that gas-rich galaxies at high redshift experience a temporary increase in their star formation activity as they assemble into denser environments. Using Hubble Space Telescope Advanced Camera for Surveys imaging, we find that disturbed morphologies are common among the 24 {mu}m detected cluster and group members and become more prevalent in regions of higher galaxy density. We conclude that mergers are the dominant triggering mechanism responsible for the enhanced star formation found in the Cl1604 groups, while a mix of harassment and mergers are likely driving the activity of the cluster galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Space Shuttle Main Engine plume spectral monitoring preliminary results

In order to provide the information necessary to develop a rocket engine ground test failure detection monitor which keys on anomalous activity in the plume, a series of experimental observations were made during single engine Space Shuttle Main Engine (SSME) tests. The observations were conducted from the 220 nm wavelength in the ultraviolet out to the 15 micron wavelength in the infrared. Four types of instruments were employed including analog autoranging narrow band radiometers, optical multichannel analyzers, mechanical scanning and film plate spectrometers, and imaging cameras. Some results included: strong OH radiation in the UV up to vibrational transition state four; Na and K radiation lines in all phases of engine operation; reaction of some of the instruments to minor engine anomalies; good shock structure imaging; striations in the flow in the 310 nm OH band; and detection of gross changes in engine operating state such as start or shutdown.

Cikanek, H. A., III↗

Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging

We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Synthetic β-sheets mimicking fibrillar and oligomeric structures for evaluation of spectral X-ray scattering technique for biomarker quantification

Archetypical cross-β spines sharpen the boundary between functional and pathological proteins including β-amyloid, tau, α-synuclein and transthyretin are linked to many debilitating human neurodegenerative and non-neurodegenerative amyloidoses. An increased focus on development of pathogenic β-sheet specific fluid and imaging structural biomarkers and conformation-specific monoclonal antibodies in targeted therapies has been recently observed. Identification and quantification of pathogenic oligomers remain challenging for existing neuroimaging modalities. We propose two artificial β-sheets which can mimic the nanoscopic structural characteristics of pathogenic oligomers and fibrils for evaluating the performance of a label free, X-ray based biomarker detection and quantification technique. Highly similar structure with elliptical cross-section and parallel cross-β motif is observed among recombinant α-synuclein fibril, Aβ-42 fibril and artificial β-sheet fibrils. We then use these β-sheet models to assess the performance of spectral small angle X-ray scattering (sSAXS) technique for detecting β-sheet structures. sSAXS showed quantitatively accurate detection of antiparallel, cross-β artificial oligomers from a tissue mimicking environment and significant distinction between different oligomer packing densities such as diffuse and dense packings. The proposed synthetic β-sheet models mimicked the nanoscopic structural characteristics of β-sheets of fibrillar and oligomeric states of Aβ and α-synuclein based on the ATR-FTIR and SAXS data. The tunability of β-sheet proportions and shapes of structural motifs, and the low-cost of these β-sheet models can become useful test materials for evaluating β-sheet or amyloid specific biomarkers in a wide range of neurological diseases. By using the proposed synthetic β-sheet models, our study indicates that the sSAXS has potential to evaluate different stages of β-sheet-enriched structures including oligomers of pathogenic proteins.

59 BASIC BIOLOGICAL SCIENCES↗

High resolution hard x-ray microscope on a second generation synchrotron source

A full-field, transmission x-ray microscope (TXM) operating in the energy range of 7-11 keV has been installed at the U7A beamline at the National Synchrotron Radiation Laboratory, a second generation synchrotron source operating at 0.8 GeV. Although the photon flux at sample position in the operating energy range is significantly low due to its relatively large emittance, the TXM can get high quality x-ray images with a spatial resolution down to 50 nm with acceptable exposure time. This TXM operates in either absorption or Zernike phase contrast mode with similar resolution. This TXM is a powerful analytical tool for a wide range of scientific areas, especially studies on nanoscale phenomena and structural imaging in biology, materials science, and environmental science. We present here the property of the x-ray source, beamline design, and the operation and key optical components of the x-ray TXM. Plans to improve the throughput of the TXM will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-waveform inversion and least-squares reverse-time migration imaging of collimated ultrasonic-beam data for high-resolution wellbore integrity monitoring

Los Alamos National Laboratory (LANL) has recently developed an ultrasonic side-lobe suppressed Bessel collimated beam transducer for low-frequency imaging through highly attenuating materials. In this paper, we study the effectiveness of using such a collimated ultrasonic-beam transducer for imaging concrete heterogeneities outside borehole casing for high-resolution borehole imaging and wellbore integrity monitoring. We obtain detailed concrete heterogeneities including a low-velocity zone using ultrasound data acquired with a 3D imaging prototype and our recently developed full-waveform inversion and least-squares reverse-time migration methods. Full-waveform inversion fits synthetic ultrasonic waveforms with recorded waveforms to build a high-resolution velocity model. Least-squares reverse-time migration produces a high-resolution structural image showing material discontinuities. Finally, our results demonstrate that LANL's 3D imaging system with a collimated ultrasonic-beam transducer together with full-waveform inversion and least-squares reverse-time migration imaging has great potential for high-resolution single-well borehole imaging and non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Nanoscale x-ray imaging of circuit features without wafer etching

Modern integrated circuits (ICs) employ a myriad of materials organized at nanoscale dimensions, and certain critical tolerances must be met for them to function. To understand departures from intended functionality, it is essential to examine ICs as manufactured so as to adjust design rules ideally in a nondestructive way so that imaged structures can be correlated with electrical performance. Electron microscopes can do this on thin regions or on exposed surfaces, but the required processing alters or even destroys functionality. Microscopy with multi-keV x-rays provides an alternative approach with greater penetration, but the spatial resolution of x-ray imaging lenses has not allowed one to see the required detail in the latest generation of ICs. X-ray ptychography provides a way to obtain images of ICs without lens-imposed resolution limits with past work delivering 20–40-nm resolution on thinned ICs. We describe a simple model for estimating the required exposure and use it to estimate the future potential for this technique. Here we show that this approach can be used to image circuit detail through an unprocessed 300-μm-thick silicon wafer with sub-20-nm detail clearly resolved after mechanical polishing to 240-μm thickness was used to eliminate image contrast caused by Si wafer surface scratches. Here, by using continuous x-ray scanning, massively parallel computation, and a new generation of synchrotron light sources, this should enable entire nonetched ICs to be imaged to 10-nm resolution or better while maintaining their ability to function in electrical tests.

36 MATERIALS SCIENCE↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

Reconstruction of biofilm images: combining local and global structural parameters

Digitized images can be used for quantitative comparison of biofilms grown under different conditions. Using biofilm image reconstruction, it was previously found that biofilms with a completely different look can have nearly identical structural parameters and that the most commonly utilized global structural parameters were not sufficient to uniquely define these biofilms. Here, additional local and global parameters are introduced to show that these parameters considerably increase the reliability of the image reconstruction process. Assessment using human evaluators indicated that the correct identification rate of the reconstructed images increased from 50% to 72% with the introduction of the new parameters into the reconstruction procedure. An expanded set of parameters especially improved the identification of biofilm structures with internal orientational features and of structures in which colony sizes and spatial locations varied. Hence, the newly introduced structural parameter sets helped to better classify the biofilms by incorporating finer local structural details into the reconstruction process.

biofilm↗

The effect of radar azimuth angle on cultural data

Emphasis is placed on the role that the orientation of observed features has on the grey tone of the resulting positive image. As an example it is shown that in the Los Angeles urbanized region, large areas have significantly lower grey tones than adjacent areas having similar land cover. It is determined that this effect is the result of the angle difference between the radar azimuth and the street pattern and especially the orientation of the walls of the structures imaged. Therefore, knowledge of this information is essential in order to ensure accurate interpretation of radar imagery. It is concluded that for radar systems operated from platforms which have fixed azimuth angles (e.g., satellite systems such as Seasat-A), an interpretation methodology, which considers street patterns, is considered especially critical for proper and accurate SAR imagery.

Bryan, M. L.↗