Search NASA⌕ Search

SEARCH · Search NASA

Results for “subcritical experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Spatial corrections for pulsed-neutron reactivity measurements.

For pulsed-neutron experiments performed in a subcritical reactor, the reactivity obtained from the area-ratio method is sensitive to detector positions. The spatial effects are induced by the presence of both the prompt neutron harmonics and the delayed neutron harmonics in the reactor. The traditional kinetics distortion factor is only limited to correcting the spatial effects caused by the fundamental prompt-{alpha} mode. In this paper, we derive spatial correction factors fp and fd to account for spatial effects induced by the prompt neutron harmonics and the delayed neutron harmonics, respectively. Our numerical simulations with the FX2-TH time-dependent multigroup diffusion code indicate that the high-order prompt neutron harmonics lead to significant spatial effects and cannot be neglected in calculating the spatial correction factors. The prompt spatial correction factor fp can be simply determined by the ratio of the normalized detector responses corresponding to the fundamental k-mode and the prompt neutron flux integrated over the pulse period. Thus, it is convenient to calculate and provides physically intuitive explanations on the spatial dependence of reactivity measured in the MUSE-4 experiments: overestimation of the subcriticality in regions close to the external neutron source and underestimation of the subcriticality away from the source but within the fuel region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neural network and area method interpretation of pulsed experiments

The determination of the subcriticality level is an important issue in accelerator-driven system technology. The area method, originally introduced by N. G. Sjoestrand, is a classical technique to interpret flux measurement for pulsed experiments in order to reconstruct the reactivity value. In recent times other methods have also been developed, to account for spatial and spectral effects, which were not included in the area method, since it is based on the point kinetic model. The artificial neural network approach can be an efficient technique to infer reactivities from pulsed experiments. In the present work, some comparisons between the two methods are carried out and discussed. (authors)

43 PARTICLE ACCELERATORS↗

On the prediction of critical flutter conditions from subcritical response data and some related wind-tunnel experience

Methods of interpreting response measurements which could be amenable to flight flutter testing procedures were studied analytically and in the wind tunnel. One suggested scheme, which requires evaluation, is an iterative technique in which derivatives obtained from subcritical response data are used to indicate the approach to flutter. A simplification of this procedure was considered by examining the manner in which a single characteristic of the subcritical response behaves in relation to variations of the density or dynamic pressure in the approach to flutter. The use of this single parameter scheme was examined for random excitation as well as for sinusoidal forcing. The feasibility of the method is illustrated by several examples and the relative merits of random and sinusoidal excitation are discussed.

Houbolt, J. C.↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Threshold Field That Separates Domains of Subcritical and Deeply Subcritical Microwave Discharges Ignited on a Dielectric Surface

Microwave discharges initiated by an electromagnetic (EM) vibrator and ignited on the inner surface of a dielectric tube in a quasi-optical EM beam are experimentally studied. A threshold level of the microwave field that separates domains of subcritical and deeply subcritical microwave discharges is determined in experiments. Experiments show that streamer channels of the subcritical discharge propagate from the initiator along the propagation direction of the EM wave and in the opposite direction under certain conditions. Variations in the power of the microwave beam can be used to change length of the plasma region of the subcritical discharge along the wave vector of the microwave beam and control the level of the EM energy absorbed in the plasma regions of the deeply subcritical microwave discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

A Theoretical and Experimental Investigation of the Lift and Drag Characteristics of Hydrofoils at Subcritical and Supercritical Speeds

A theoretical and experimental investigation at subcavitation speeds was made of the effect of the free-water surface and rigid boundaries on the lift and drag of an aspect-ratio-10 hydrofoil at both subcritical and supercritical speeds and of an aspect ratio-4 hydrofoil at supercritical speeds. Approximate theoretical solutions for the effects of the free-water surface and rigid boundaries on drag at subcritical speeds are developed. An approximate theoretical solution for the effects of these boundaries on drag at subcritical speeds is also presented. The agreement between theory and experiment at both supercritical and subcritical speeds is satisfactory for engineering calculations of hydrofoil characteristics from aerodynamic data. The experimental investigation indicated no appreciable effect of the limiting speed of wave propagation on lift-curve slope or angle of zero lift. It also showed that the increase in drag as the critical speed is approached from the supercritical range is gradual. The result is contrary to the abrupt increase at the critical speed predicted by theory.

Wadlin, Kenneth L↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LANL FY21 NCSP Highlights [Slides]

This presentation highlights the activities of Los Alamos National Laboratory (LANL) in fiscal year 2021.These include the celebration of the tenth anniversary of NCERC operations, a large experiment campaign (IER 488 - MUSiC: Measurements of Uranium Subcritical and Critical), preparation for FY22 experiments, the completion of several ongoing experiments, and a control system upgrade project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NASA cryogenic fluid management space experiment efforts, 1960-1990

A history of technological development for subcritical cryogenic fluid management (CFM) through space experiments is given for the period 1960 to 1990. Space experiments with liquid hydrogen were conducted in the early 1960's. Efforts since then have consisted of studies and designs of potential space experiments. A chronology of CFM space experiments and design efforts is included.

Glover, Daniel↗

Feasibility Study for a Subcritical Assembly at the Oak Ridge National Laboratory

A conceptual design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). The proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available at the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, $M$, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: the addition of fissile material to increase neutron multiplication (mass), a core separation experiment (interaction), the effect of adding moderators to the core (moderation), and the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity in the event that nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cryogenic Orbital Nitrogen Experiment (CONE): Phase A/B design study

Subcritical cryogenic fluid management (CFM) has long been recognized as an enabling technology for future space missions. Subcritical liquid storage and supply are two of the five CFM technology areas that need to be studied in the low gravity on-orbit environment. The Cryogenic Orbital Nitrogen Experiment (CONE) is a LN2 cryogenic storage and supply system demonstration placed in orbit by the National Space Transportation System (NSTS) Orbiter and operated as an in-bay payload. In-space demonstration of CFM using LN2 with a few well defined areas of focus would provide the confidence level required to implement subcritical cryogen use and is the first step towards the more far reaching issue of cryogen transfer and tankage resupply. A conceptual approach for CONE was developed and an overview of the program is described including the following: (1) a description of the background and scope of the technology objectives; (2) a description of the payload design and operation; and (3) the justification for CONE relating to potential near term benefits and risk mitigation for future systems. Data and criteria is provided to correlate in-space performance with analytical and numerical modeling of CFM systems.

Bailey, William J.↗

Application Areas of Potential Challenge to Nuclear Criticality Safety Margins for Future High Temperature Gas Reactor Fuel Cycle Activities

Fuel cycle activities for future high temperature gas reactors (HTGRs) will involve uranium enrichments and fissile material configurations that differ significantly from those of current light water reactor (LWR) fuel cycle activities. LWR fuel cycle activities are supported by a wealth of applicable critical experiment benchmarks that allow margins of subcriticality to be well-defined. In contrast, few critical experiments are clearly applicable to several portions of the HTGR fuel cycle. This work identifies HTGR fuel cycle activities presenting potential concern for reliable demonstration of an adequate margin of subcriticality. Recommendations are developed to address these areas of concern.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Experimental Investigation on the Static Equilibria and Dynamics of Liquid Bridges

A liquid bridge is a volume of liquid held between two or more solid supports. In the case of small disk supports with a sharp edge, the contact line between the bridge and the support disk will be anchored along the edge of the disk. For these cases the solid presents a geometrical singularity and the contact angle is indeterminate within a given range. This dissertation presents research conducted on liquid bridges with anchored contact lines. The three major topics covered are: determining the role of support geometry on static equilibria, liquid bridge dynamical behavior, and forces exerted by a liquid bridge on a support structure. The work was primarily experimental and conducted in a "Plateau tank" that allowed for the simulation of equivalent low-gravity conditions. The main thrust of the experimental work involved the use of a high resolution optical measurement system for imaging the dynamic zone shape, measurement of the static and dynamic contact angles and non-invasive analysis of excited surface modes. The liquid bridge was manipulated by computer controlled linear actuators which allowed precise control over the physical characteristics of the bridge. Experiments have been carried out to locate a bifurcation point along the maximum volume axisymmetric stability margin. Below the critical slenderness the bifurcation from an axisymmetric to a stable nonaxisymmetric configuration is supercritical. However, above this critical slenderness, the bifurcation is subcritical. A series of experiments analyzed the effect on axisymmetric bridge stability by using support disks of different radii, The shape behavior as transition points were approached, as well as the limiting case of a vanishing support radius was investigated. Experiments were performed to determine the resonant frequencies of axisymmetric bridges subject to lateral vibrations. Anomolous results led to a series of experiments to characterize nonlinearities present in the dynamic bridge shape. Finally, an attempt was made to experimentally measure the force exerted by the bridge on the lower support disk. This was done through use of a force balance apparatus. Particular attention was paid to the behavior of the bridge as the minimum volume stability limit was approached.

Resnick, Andrew Howard↗

Design of Nuclear Criticality Safety Framework for Hands-on Construction of Fast Systems Over Ranges of Multiplication

Since 1945, Los Alamos National Laboratory (LANL) has performed critical experiments, primarily at the Los Alamos Critical Experiments Facility (LACEF) at Technical Area 18 (TA-18). Since 2011, these experiments have been conducted by the National Criticality Experiments Research Center (NCERC), operated by LANL, at the Device Assembly Facility (DAF) in the Nevada National Security Site (NNSS). These experiments utilize various types of Special Nuclear Material (SNM). Some of these experiments utilize what is referred to as the Rocky Flat Shells, which are called such as they came from the Rocky Flats Plant. These concentric hemi-shells are made of Highly Enriched Uranium (HEU), which is 93 w/o 235U. Fig. 1. Subset of the Rocky Flat Shells LANL is designing a new subcritical hands-on experiment with the goal of achieving a neutron multiplication in the range of 50 to 200, which correlates to Keff values of 0.98 to 0.995. ANSI/ANS-1 is the standard for Conduct of Critical Experiments which governs critical operations at NCERC. Section 3.9 of ANSI/ANS-1 states that when manipulating a critical assembly by hand, the predicted k eff of a known configuration should not exceed 0.95 (a neutron multiplication of 20). This presents a challenge, as this system would have a higher multiplication than 20 and the assembly would have to remain subcritical in normal and credible accident scenarios. To ensure the safety of such an assembly, the different normal and abnormal conditions that could alter the criticality 1 MCNP® and Monte Carlo N-Particle® are registered trademarks owned by Triad National Security, LLC, manager and operator of Los Alamos National Laboratory. Any third party use of such registered marks should be properly of the system must be considered and analyzed. If such a condition is deemed to be credible, it will be further investigated using the Monte Carlo N-Particle (MCNP) transport code. If the results of these simulations show that a k eff larger than one could be possible, modifications to the assembly will be made until such an event is deemed no longer possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗