Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronized sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Framework for custom event sample augmentations for ATLAS analysis data

For HEP event processing, data is typically stored in column-wise synchronized containers, such as most prominently ROOT’s TTree, which have been used for several decades to store by now over 1 exabyte. These containers can combine row-wise association capabilities needed by most HEP event processing frameworks (e.g. Athena for ATLAS) with column-wise storage, which typically results in better compression and more efficient support for many analysis use-cases. One disadvantage is that these containers, TTree in the HEP use-case, require to contain the same attributes for each entry/row (representing events), which can make extending the list of attributes very costly in storage, even if those are only required for a small subsample of events. Since the initial design, the ATLAS software framework features powerful navigational infrastructure to allow storing custom data extensions for subsamples of events in separate, but synchronized containers. This allows adding event augmentations to ATLAS standard data products (such as DAOD-PHYS or PHYSLITE) avoiding duplication of those core data products, while limiting their size increase. For this functionality, the framework does not rely on any associations made by the I/O technology (i.e. ROOT), however it supports TTree friends and builds the associated index to allow for analysis outside of the ATLAS framework. A prototype based on the Long-Lived Particle search is implemented and preliminary results with this prototype will be presented. At this point, augmented data are stored within the same file as the core data. Storing them in separate files will be investigated in future, as this could provide more flexibility, e.g. certain sites may only want a subset of several augmentations or augmentations can be archived to tape once their analysis is complete.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shuttle extravehicular activity signal processor pulse amplitude modulation decommutator

To provide data with long-term stability and accuracy, the pulse amplitude modulation (PAM) decommutator was synchronized to the PAM-return to zero wavetrain, and each channel was sampled with a common sample and hold circuit and digitized sequentially. The digital value of each channel was then scaled by the digital value of the calibration channels. The corrected digital value of each channel was stored for one complete frame and then transferred to the multiplexer-demultiplexer at a high rate in one block of serial digital data. A test model was built to demonstrate this design approach taken for the PAM decom and performance data was provided. The accuracies obtained with various signal to noise ratios are shown.

Noble, D. E.↗

Exploration Ground Data Systems (xGDS) Overview

xGDS supports rapid scientific decision making by synchronizing the time and mapped location of observation notes, instrument data, photos, video, samples and other data. xGDS is a suite of web tools, developed at NASA Ames Research Center to support remote science operations in analog missions and prototype new ideas for planetary exploration. During operations, xGDS displays science data in real-time with geographic context, supporting key decisions (e.g. sample site selection). Post-operations, xGDS enables efficient analysis of data by correlating data products in time and on the map. xGDS has been developed in close collaboration with science teams since 2009, and used enthusiastically by upwards of 100 scientists to support scientific field research and data analysis.

Ground Data System↗

Uncertainty Error Modeling for Non-Linear State Estimation With Unsynchronized SCADA and µPMU Measurements

Distribution systems of the future smart grid require enhancements to the reliability of distribution system state estimation (DSSE) in the face of low measurement redundancy, unsynchronized measurements, and dynamic load profiles. Micro phasor measurement units (µPMUs) facilitate co-synchronized measurements with high granularity, albeit at an often prohibitively expensive installation cost. Supervisory control and data acquisition (SCADA) measurements can supplement µPMU data, although they are received at a slower sampling rate. Further complicating matters is the uncertainty associated with load dynamics and unsynchronized measurements–not only are the SCADA and µPMU measurements not synchronized with each other, but the SCADA measurements themselves are received at different time intervals with respect to one another. This paper proposes a non-linear state estimation framework which models dynamic load uncertainty error by updating the variances of the unsynchronized measurements, leading to a time-varying system of weights in the weighted least squares state estimator. Case studies are performed on the 33-Bus Distribution System in MATPOWER, using Ornstein–Uhlenbeck stochastic processes to simulate dynamic load conditions.

Cooper, Austin↗

Synchronistic preparation of fibre-like SiC and cubic-ZrO{sub 2}/SiC composite from zircon via carbothermal reduction process

Graphical abstract: Display Omitted Highlights: ► Zircon carbothermal reduction was carried out in a tailor-made device at high-temperature air atmosphere. ► Fibre-like SiC and cubic-ZrO{sub 2}/SiC composite were obtained synchronically. ► Zirconium and silicon in zircon ore was initial separated. ► [SiO{sub 4}] was mutated to fibre-like SiC, while [ZrO{sub 8}] was transformed to cubic ZrO{sub 2}. ► The SiC were surprisingly enriched in the reducing atmosphere charred coal particles layers by gas–solid reaction. -- Abstract: Fibre-like SiC and cubic-ZrO{sub 2}/SiC composite were prepared respectively from zircon with yttrium oxide addition via carbothermal reduction process at 1600 °C for 4 h in an air atmosphere furnace, where the green samples were immerged in charred coal particles inside a high-temperature enclosed corundum crucible. The reaction products were characterized by XRD, XRF, XPS and SEM. The results indicate that ZrO{sub 2} in the products was mainly existed in the form of cubic phase. The reacted samples mainly contain cubic ZrO{sub 2}, β-SiC and trace amounts of zircon, with the SiC accounting for 14.8 wt%. Furthermore, a large quantity of fibre-like SiC was surprisingly found to concentrate in the charred coal particles layers around the samples. This study obtains fibre-like SiC and cubic-ZrO{sub 2}/SiC composite synchronically from zircon via carbothermal reduction process, which also bring a value-added high-performance application for natural zircon.

36 MATERIALS SCIENCE↗

Preserving correlations between trajectories for efficient path sampling

Importance sampling of trajectories has proved a uniquely successful strategy for exploring rare dynamical behaviors of complex systems in an unbiased way. Carrying out this sampling, however, requires an ability to propose changes to dynamical pathways that are substantial, yet sufficiently modest to obtain reasonable acceptance rates. Satisfying this requirement becomes very challenging in the case of long trajectories, due to the characteristic divergences of chaotic dynamics. Here, we examine schemes for addressing this problem, which engineer correlation between a trial trajectory and its reference path, for instance using artificial forces. Our analysis is facilitated by a modern perspective on Markov chain Monte Carlo sampling, inspired by non-equilibrium statistical mechanics, which clarifies the types of sampling strategies that can scale to long trajectories. Viewed in this light, the most promising such strategy guides a trial trajectory by manipulating the sequence of random numbers that advance its stochastic time evolution, as done in a handful of existing methods. In cases where this “noise guidance” synchronizes trajectories effectively, as the Glauber dynamics of a two-dimensional Ising model, we show that efficient path sampling can be achieved for even very long trajectories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sampling analysis for the Earth Radiation Budget Satellite System mission based on orbital coverage and cloud variability

The reported study represents an extension of an investigation by Harrison et al. (1976). Based on the results of sampling studies, two 98 deg inclined orbits coupled with a 56 deg inclination orbit appear to satisfy the science requirements on both regional and zonal scales. The NOAA sun-synchronous satellites in the TIROS-N series could adequately cover the high latitudes and a satellite having an inclination of 56 deg could provide sampling in the mid and low latitude areas where variations in radiation energetics are most dynamic. Attention is given to studies of time and space coverage, zonal evaluations, a regional analysis, and statistics describing the regional variations of cloud cover. A table is presented with data concerning the uncertainty of monthly mean reflected irradiance due to cloud variability for selected northern hemisphere regions.

Harrison, E. F.↗

Motion mitigation for lung cancer patients treated with active scanning proton therapy

Purpose: Motion interplay can affect the tumor dose in scanned proton beam therapy. This study assesses the ability of rescanning and gating to mitigate interplay effects during lung treatments. Methods: The treatments of five lung cancer patients [48 Gy(RBE)/4fx] with varying tumor size (21.1–82.3 cm{sup 3}) and motion amplitude (2.9–30.6 mm) were simulated employing 4D Monte Carlo. The authors investigated two spot sizes (σ ∼ 12 and ∼3 mm), three rescanning techniques (layered, volumetric, breath-sampled volumetric) and respiratory gating with a 30% duty cycle. Results: For 4/5 patients, layered rescanning 6/2 times (for the small/large spot size) maintains equivalent uniform dose within the target >98% for a single fraction. Breath sampling the timing of rescanning is ∼2 times more effective than the same number of continuous rescans. Volumetric rescanning is sensitive to synchronization effects, which was observed in 3/5 patients, though not for layered rescanning. For the large spot size, rescanning compared favorably with gating in terms of time requirements, i.e., 2x-rescanning is on average a factor ∼2.6 faster than gating for this scenario. For the small spot size however, 6x-rescanning takes on average 65% longer compared to gating. Rescanning has no effect on normal lung V{sub 20} and mean lung dose (MLD), though it reduces the maximum lung dose by on average 6.9 ± 2.4/16.7 ± 12.2 Gy(RBE) for the large and small spot sizes, respectively. Gating leads to a similar reduction in maximum dose and additionally reduces V{sub 20} and MLD. Breath-sampled rescanning is most successful in reducing the maximum dose to the normal lung. Conclusions: Both rescanning (2–6 times, depending on the beam size) as well as gating was able to mitigate interplay effects in the target for 4/5 patients studied. Layered rescanning is superior to volumetric rescanning, as the latter suffers from synchronization effects in 3/5 patients studied. Gating minimizes the irradiated volume of normal lung more efficiently, while breath-sampled rescanning is superior in reducing maximum doses to organs at risk.

60 APPLIED LIFE SCIENCES↗

A frequency and amplitude scanned quadrupole mass filter for the analysis of high m/z ions

Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitude of a sine wave to measure the m/z spectrum, the frequency of a trapezoidal wave is digitally scanned. A synchronous, narrow-range (<0.2%) amplitude scan overlays the frequency scan to improve the sampling resolution. Because the frequency is the primary quantity that is scanned, there is, in principle, no upper m/z limit. The frequency signal is constructed from a stabilized base clock using a field programmable gate array. This signal drives integrating amplifiers which generate the trapezoidal waves. For a trapezoidal wave the harmonics can be minimized by selecting the appropriate rise and fall times. To achieve a high resolving power, the digital signal has low jitter, and the trapezoidal waveform is generated with high fidelity. The QMF was characterized with cesium iodide clusters. Singly and multiply charged clusters with z up to +5 were observed. A resolving power of ∼1200 (FWHM) was demonstrated over a broad m/z range. Resolution was lost above 20 000 Th, partly because of congestion due to overlapping multiply charged clusters. Ions were observed for m/z values well in excess of 150 000 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the design of an earth radiation budget instrument with system simulations. Part 2: Minimization of instantaneous sampling errors for CERES-I

Much of the new record of broadband earth radiation budget satellite measurements to be obtained during the late 1990s and early twenty-first century will come from the dual-radiometer Clouds and Earth's Radiant Energy System Instrument (CERES-I) flown aboard sun-synchronous polar orbiters. Simulation studies conducted in this work for an early afternoon satellite orbit indicate that spatial root-mean-square (rms) sampling errors of instantaneous CERES-I shortwave flux estimates will range from about 8.5 to 14.0 W/m on a 2.5 deg latitude and longitude grid resolution. Rms errors in longwave flux estimates are only about 20% as large and range from 1.5 to 3.5 W/sq m. These results are based on an optimal cross-track scanner design that includes 50% footprint overlap to eliminate gaps in the top-of-the-atmosphere coverage, and a 'smallest' footprint size to increase the ratio in the number of observations lying within to the number of observations lying on grid area boundaries. Total instantaneous measurement error also depends on the variability of anisotropic reflectance and emission patterns and on retrieval methods used to generate target area fluxes. Three retrieval procedures from both CERES-I scanners (cross-track and rotating azimuth plane) are used. (1) The baseline Earth Radiaton Budget Experiment (ERBE) procedure, which assumes that errors due to the use of mean angular dependence models (ADMs) in the radiance-to-flux inversion process nearly cancel when averaged over grid areas. (2) To estimate N, instantaneous ADMs are estimated from the multiangular, collocated observations of the two scanners. These observed models replace the mean models in computation of satellite flux estimates. (3) The scene flux approach, conducts separate target-area retrievals for each ERBE scene category and combines their results using area weighting by scene type. The ERBE retrieval performs best when the simulated radiance field departs from the ERBE mean models by less than 10%. For larger perturbations, both the scene flux and collocation methods produce less error than the ERBE retrieval. The scene flux technique is preferable, however, because it involves fewer restrictive assumptions.

Stowe, Larry↗

Time-synchronized continuous wave laser-induced fluorescence on an oscillatory xenon discharge

A novel approach to time-synchronizing laser-induced fluorescence measurements to an oscillating current in a 60 Hz xenon discharge lamp using a continuous wave laser is presented. A sample-hold circuit is implemented to separate out signals at different phases along a current cycle, and is followed by a lock-in amplifier to pull out the resulting time-synchronized fluorescence trace from the large background signal. The time evolution of lower state population is derived from the changes in intensity of the fluorescence excitation line shape resulting from laser-induced fluorescence measurements of the 6s{sup Prime }[1/2]{sub 1}{sup 0}-6p{sup Prime }[3/2]{sub 2} xenon atomic transition at {lambda}= 834.68 nm. Results show that the lower state population oscillates at twice the frequency of the discharge current, 120 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Analog/Digital Receiver

Advanced hybrid analog/digital receiver processes intermediate-frequency (IF) signals carrying digital data in form of phase modulation. Uses IF sampling and digital phase-locked loops to track carrier and subcarrier signals and to synchronize data symbols. Consists of three modules: IF assembly, signal-processing assembly, and test-signal assembly. Intended for use in Deep Space Network, but presumably basic design modified for such terrestrial uses as communications or laboratory instrumentation where signals weak and/or noise strong.

Brown, D. H.↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Switch-like reprogramming of gene expression after fusion of multinucleate plasmodial cells of two Physarum polycephalum sporulation mutants

Highlights: •We investigate reprogramming of gene expression in multinucleate single cells. •Cells of two differentiation control mutants are fused. •Fused cells proceed to alternative gene expression patterns. •The population of nuclei damps stochastic fluctuations in gene expression. •Dynamic processes of cellular reprogramming can be observed by repeated sampling of a cell. -- Abstract: Nonlinear dynamic processes involving the differential regulation of transcription factors are considered to impact the reprogramming of stem cells, germ cells, and somatic cells. Here, we fused two multinucleate plasmodial cells of Physarum polycephalum mutants defective in different sporulation control genes while being in different physiological states. The resulting heterokaryons established one of two significantly different expression patterns of marker genes while the plasmodial halves that were fused to each other synchronized spontaneously. Spontaneous synchronization suggests that switch-like control mechanisms spread over and finally control the entire plasmodium as a result of cytoplasmic mixing. Regulatory molecules due to the large volume of the vigorously streaming cytoplasm will define concentrations in acting on the population of nuclei and in the global setting of switches. Mixing of a large cytoplasmic volume is expected to damp stochasticity when individual nuclei deliver certain RNAs at low copy number into the cytoplasm. We conclude that spontaneous synchronization, the damping of molecular noise in gene expression by the large cytoplasmic volume, and the option to take multiple macroscopic samples from the same plasmodium provide unique options for studying the dynamics of cellular reprogramming at the single cell level.

60 APPLIED LIFE SCIENCES↗

A Method for Dynamic Kolsky Bar Compression at High Temperatures: Application to Ti-6Al-4V

Abstract An experimental apparatus for measuring the dynamic behavior of materials subjected to strain rates on the order of 10 $$^3$$ 3 s $$^{-1}$$ - 1 and temperatures up to 800°C with a unique triple actuation system is developed in this work. This system is based on the traditional Kolsky (or split-Hopkinson pressure) bar design, with the addition of an external furnace used to heat the specimen to the desired temperature. A synchronized triple pneumatic actuation system is used to control the motion and timing of the the sample, incident, and transmitted bars. The cold contact time (CCT), or the time during which the heated sample is in contact with the room temperature bars before compression, is measured experimentally and carefully controlled to minimize the development of a temperature gradient across the sample and avoid heating of the bars. Experiments are performed in conjunction with ultra high speed imaging and 2D digital image correlation (DIC), as well as high speed thermal imaging. To verify the viability of the proposed system, experiments were conducted on Ti-6Al-4V (wt.%) at temperatures from 25°C up to and 800°C at an average strain rate of approximately 1200 s $$^{-1}$$ - 1 .

36 MATERIALS SCIENCE↗

New contactless method for thermal diffusivity measurements using modulated photothermal radiometry

Modulated photothermal radiometry is a non-destructive and contactless technique for the characterization of materials. It has two major advantages: a good signal-to-noise ratio through a synchronous detection and a low dependence on the heating power and the optical properties of the sample surface. This paper presents a new method for characterizing the thermal diffusivity of a material when the phase shift between a modulated laser power signal and the thermal signal of a plate sample is known at different frequencies. The method is based on a three-dimensional analytical model which is used to determine the temperature amplitude and the phase in the laser heating of the plate. A new simple formula was developed through multi-parametric analysis to determine the thermal diffusivity of the plate with knowledge of the frequency at the minimum phase shift, the laser beam radius r{sub 0} and the sample thickness L. This method was developed to control the variation of the thermal diffusivity of nuclear components and it was first applied to determine the thermal diffusivity of different metals: 304 L stainless steel, nickel, titanium, tungsten, molybdenum, zinc, and iron. The experimental results were obtained with 5%–10% accuracy and corresponded well with the reference values. The present paper also demonstrates the limit of application of this method for plate with thickness r{sub 0}/100 ≤ L ≤ r{sub 0}/2. The technique is deemed interesting for the characterization of barely accessible components that require a contactless measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗