Monitoring System Performance (Presentation)
Requirements for a standard test to rate the durability of photovoltaic (PV) modules at system voltage are discussed.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Requirements for a standard test to rate the durability of photovoltaic (PV) modules at system voltage are discussed.
The current trend for space application systems is towards fully integrated systems-on-a-chip. To facilitate this drive, high-voltage transistors must reside on the same substrate as low-voltage transistors. These systems must also be radiation tolerant, particularly for space missions such as the Europa Lander and Titan Explorer. SOI CMOS technology offers high levels of radiation hardness. As a result, a high-voltage lateral MOSFET has been developed in a partially-depleted (PD) SOI technology. Utilizing high voltages causes a parasitic transistor to have non-negligible effects on a circuit. Several circuit architectures have been used to compensate for the radiation induced threshold voltage shift of the parasitic back-channel transistor. However, a new architecture for high-voltage systems must be employed to bias the substrate to voltage levels insuring all parasitic transistors remain off. An active substrate driver has been developed to accomplish task. Additional information is contained in the original extended abstract.
A thermoelectric assembly and method are provided. The thermoelectric assembly can extend at least partially around a perimeter of a first fluid conduit. The thermoelectric assembly can include a plurality of thermoelectric sub-assemblies aligned with one another along the perimeter of the first fluid conduit. Each thermoelectric sub-assembly can include a plurality of thermoelectric elements in parallel electrical communication with one another, and at least one shunt a plurality of electrically insulating elements to prevent current flow in a plane perpendicular to the first direction between adjacent thermoelectric sub-assemblies.
Technological advancements in high voltage systems have pushed sulfur hexafluoride (SF6) to its operational limits. Furthermore, this gas has other drawbacks including a high liquefaction temperature and a high global warming potential. Therefore, there has been an urgent need to find alternative gases with high dielectric strength (DS). In this work, density functional theory (DFT) is used to calculate molecular descriptors that are fed into an artificial neural network (ANN) and a random forest (RF). These machine learning (ML) models are then used to predict the DS for hundreds of molecules. A finite element model (FEM) is also used to calculate the electric field profile of multiple simple electrode geometries as the applied voltage to the system is increased. Results indicate that the random forest model has better generalization to unseen data than the neural network. The highest DS value predicted by the RF was 2.16 relative to the experimental DS of SF6. The results also demonstrate how choosing a gas with a higher DS and a geometry with minimal edges and corners can significantly increase the operating voltage of an electrical system. Due to its superior generalization, the RF represents the most promising path toward an accurate DS predictor once sufficient experimental data are available.
In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.
Distribution transformers convert power from the distribution system voltage to the end-customer voltage, which consists of residences, businesses, distributed generation, campus systems, and manufacturing facilities. Amorphous metal distribution transformers (AMDT) are also more expensive and heavier than conventional silicon steel distribution transformers. This and the difficulty to measure the benefit from energy efficiency and low awareness of the technology have hindered the adoption of AMDT. This report presents the cost savings for installing AMDT and the amount of energy saved based on the improved efficiency.
With the increased observability and controllability of distribution systems, the share of behind-the-meter systems is trending upwards rapidly. As a consequence, the impact of human behaviors on system performance can no longer be ignored and should be reflected in the energy management system models. In this paper, we discuss the problem of distribution system voltage control by active power curtailment where the agent compliance of the load curtailment signal is probabilistic. We discuss the modeling of the optimal voltage control problem with probabilistic agent compliance as a chance-constrained optimization problem, its tractable safe approximation using convex restriction, and a scenario-based mixed-integer reformulation as well as the associated solution method based on augmented Lagrangian method. The numerical simulation on IEEE test system validates the effectiveness of the proposed approach in obtaining high-quality feasible load curtailment signal with low computational cost, which makes it a viable tool for real time decision making.
Lightning induced voltages in aircraft electrical circuits
The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.
As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.
Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.
Progress made by NASA toward implementation of equipment for the conversion, management, and distribution of voltage power in space applications are reviewed. Work has been carried forward on components such as bipolar transistors, deep impurity semiconductors, conductors, dielectrics, magnetic devices, and rotary power transfer. Specific programs for the high voltage systems have included research on lightweight, low-cost conductors featuring graphite fibers containing electron donor materials for wires and cables with reduced mass and the conductivity of copper. Attention has also been given p-n junction technology for high-speed, high-current, high-voltage materials and diamond-like dielectric films which are hard, have high dielectric strength, and can operate up to 300 C. A transistor has been fabricated with a voltage of 1200 V at 100 A, with a gain of 10 and a 0.5 microsec rise/fall time. A 25 kW transformer has also been built which performs at 20 kHz with an efficiency of 99.2%.
Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.
The results of testing a high voltage electrical power system (EPS) breadboard using high voltage power processing equipment developed at Marshall Space Flight Center and Ni-Cd batteries are discussed. These test results are used to extrapolate to an efficient, reliable, high capacity EPS for near term low Earth orbit, high power applications. EPS efficiencies, figures of merit, and battery reliability with a battery protection and reconditioning circuit are presented.
Cesium propellant systems utilizing surface tension to position and transfer liquid propellant in zero-g environment studied with high voltage electrical isolation methods
The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).
The LANSCE Refurbishment Project (LANSCE-R) will revitalize the LANSCE accelerator infrastructure. Much of the equipment has been in use for over 39 years and is approaching the end of its design lifetime. As obsolescence issues make like-for-like replacements increasingly more expensive, modern systems with lower costs become a reasonable alternative. As part of the LANSCE-R project, four of the seven HV power supplies for the 805 MHz RF klystrons will be replaced. The present and future requirements for these power supplies influence the selection of replacement options. Details of the HV power supply replacement requirements and the different replacement options will be discussed. One option is to use four 95 kV, 21 A DC power supplies originally installed nearby as part of the Low Energy Demonstration Accelerator (LEDA) project. Significant material and labor cost savings can be achieved by leaving these supplies installed where they are and building a HV transport system to bring high voltage power from the existing LEDA facility to the LANSCE facility. The different replacement options will be compared based on material and labor costs as offset by long-term energy savings.
Recently, there have been several proposals submitted to funding agencies for long-lived high altitude (about 70,000 feet) airships for communications, surveillance, etc. In order for these airships to remain at altitude, high power, high efficiency, lightweight solar arrays must be used, and high efficiency power management and distribution systems must be employed. The needs for high power and high efficiency imply high voltage systems. However, the air pressure at these extreme altitudes is such that electrical power systems will be near the Paschen discharge minimum over a wide range of electrode separations. In this paper, preliminary calculations are made for acceptable high voltage design practices under ambient, hydrogen and helium gas atmospheres.