Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantum AI Based Enhanced Detection of Dementia

Quantum computing has the potential to significantly improve the early detection of Alzheimer's Disease and Related Dementias (ADRD). Quantum-enhanced machine learning can be used to perform an early screening of Alzheimer's disease using brain imaging data based on dataset of MRI scans from both healthy individuals and those diagnosed with Alzheimer's. This study aims to demonstrate the potential of quantum transfer learning to enhance the performance of the classical deep learning model for dementia detection. Using the MRI sagittal images available in the OASIS-2 (64 demented and 72 non-demented subjects between 60 and 96 years), we show how quantum techniques can transform a suboptimal classical model into a more effective solution for dementia detection, highlighting their potential impact on advancing healthcare technology. We begin with a simple classical deep learning model with a significantly smaller number of parameters, which gives suboptimal performance on the problem. Then, we apply different configurations of quantum transfer learning based on the pre-trained weak classifier (Figure 1). We fix the weak classifier's initial convolutional layers at their fixed pre-trained parameters and replace the last set of dense layers with a dressed quantum circuit (DQN), which we train to enhance performance. We performed 4-fold cross-validation for both the classical and the hybrid quantum models and trained them using Pennylane's `default.qubit' simulator and IonQ's Aria-1 simulator (noisy simulation). We showed that with significantly fewer parameters, the quantum transfer learning-based hybrid models showed significant performance enhancement over the base weak classical deep learning model for dementia detection. To classify between a demented and non-demented subject, the accuracy of quantum-based AI methods improved by 6 to 14% compared to classical methods. The sensitivity of the models improved by 4 to 17%. This shows that there are fewer chances of misclassifying demented patients. Figure 2 compares the performance of the hybrid quantum models and their base classical model, and Table 1 summarizes the results. We illustrated that with assistance from quantum machine learning, it is possible to enhance detection for dementia based on brain images. This shows the potential for practical utility of quantum computing in ADRD research.

Bhowmik, Sounak [University of Tennessee, Knoxvill↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing the properties of nebular plasmas with optical and infrared spectroscopy

A number of current developments arising from spectroscopic studies of ionized nebulae are reviewed. Until the past decade or so, such studies were generally confined to the analysis of recombination lines from hydrogen and helium, along with collisionally excited forbidden lines from second and third row elements in the periodic table. However, the advent of efficient detectors on 8m-class telescopes has enabled the detection of recombination lines from second and third row elements, along with collisionally excited lines from much less abundant species. Significant discrepancies have been found between ionic abundances derived from collisionally excited lines and those obtained for the same ions from their recombination lines. The existence of 'cold plasma' with T{sub e}{<=} 1000 K has been confirmed for a number of planetary nebulae. Optical and infrared collisionally excited ionic lines from a wide range of 'neutron-capture' elements from beyond the iron abundance peak have also been detected. There is a consequent need for new calculations and experimental measurements of the atomic data needed to interpret these observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio and optical observations in the fields of five unidentified X-ray sources at high latitudes

Radio observations at 610 MHz and optical plates were obtained for five fields centered on the unidentified X-ray sources 3U0042 + 32, 3U0917 + 63, 3U1443 + 43, 3U1555 + 27, and 3U1809 + 50. For the first three fields, several radio sources are found which are associated with stellar objects within or near the X-ray error boxes. A 'tailed' radio galaxy has been found in Abell 2142, and this cluster is suggested as the identification for 3U1555 + 27. Although there are no radio sources greater than 0.1 flux unit within the X-ray error boxes associated with 3U1809 + 50, a Zwicky cluster surrounding the 3U position contains two radio galaxies: one with an inverted spectrum and another with a wide-angle tail. A table of positions, intensities, and suggested optical identifications is given for the 249 radio sources detected in the five fields.

Harris, D. E.↗

The Einstein soft X-ray survey of the Pleiades

The results of a 0.1-4.5-keV X-ray survey of a 2 x 2-deg area centered on the Pleiades open cluster, performed using the imaging proportional counter and high-resolution imager of the Einstein Observatory on four days in 1980-1981, are presented in extensive tables, graphs, maps, histograms, and finding charts and characterized. A total of 61 sources are detected, and 44 of these are identified with cluster members of spectral types B-M. Findings discussed include Lx/Lbol of 10 the -7th for early-type stars; F-star mean Lx like that of F stars in the Hyades and in the field (denying time evolution of Lx); mean G-star Lx = 3.7 x 10 to the 29th erg/sec; G-star activity decay more gradual than 1/sq rt t, with sharp fall for t greater than 1 Gyr; and no evidence for X-ray-emissivity/rotational-velocity correlation in a homogeneous sample of K dwarfs or a sample of K and M stars with established V sin i data.

Caillault, J.-P.↗

Advanced Very High Resolution Radiometer (AVHRR) sensor comparison characteristics

Advantages and limitations of the AVHRR multichannel sea surface temperature (MCSST) detecting technique using NOAA satellites are discussed. The error characteristics of MCSST's from statistical tables and regional AVHRR error characteristics from global anomaly charts are also discussed. Some soruces of errors and positive findings are reviewed.

Mcclain, E. P.↗

Generalised form factor dark matter in the Sun

We study the effects of energy transport in the Sun by asymmetric dark matter with momentum and velocity-dependent interactions, with an eye to solving the decade-old Solar Abundance Problem. We study effective theories where the dark matter-nucleon scattering cross-section goes as v{sub rel}{sup 2n} and q{sup 2n} with n=−1,0,1 or 2, where v{sub rel} is the dark matter-nucleon relative velocity and q is the momentum exchanged in the collision. Such cross-sections can arise generically as leading terms from the most basic nonstandard DM-quark operators. We employ a high-precision solar simulation code to study the impact on solar neutrino rates, the sound speed profile, convective zone depth, surface helium abundance and small frequency separations. We find that the majority of models that improve agreement with the observed sound speed profile and depth of the convection zone also reduce neutrino fluxes beyond the level that can be reasonably accommodated by measurement and theory errors. However, a few specific points in parameter space yield a significant overall improvement. A 3–5 GeV DM particle with σ{sub SI}∝q{sup 2} is particularly appealing, yielding more than a 6σ improvement with respect to standard solar models, while being allowed by direct detection and collider limits. We provide full analytical capture expressions for q- and v{sub rel}-dependent scattering, as well as complete likelihood tables for all models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rating Correlations Between Customs Codes and Export Control Lists: Assessing the Needs and Challenges

Correlation tables are the linchpins between the customs codes used to classify commodities in international trade and the control lists used for strategic trade control (STC) purposes. While understanding the customs classification system can help the STC community better understand strategic trade flows, better identify which trade operations require permits, and more effectively detect illegal exports, the two systems are different in scope, philosophy, content, and objectives. Many indications point to the limitations of these correlation tables, and it is important to understand the nature of the limitations and the complex underlying reasons to conceive possible improvements. As part of its Strategic Trade and Supply Chain Analytics Initiative, Argonne National Laboratory supported a study of a subset of the European Union’s TARIC correlation table. The study included development of a methodology and an approach to rating the quality and relevance of individual correlations. The study was intended as a first step to engage the STC community in deflections and initiatives to improve the conception and use of correlations, and its conclusions illustrate the scope and complex nature of the challenges to overcome. This paper presents the two classification systems, analyzes the needs for correlation tables and the complex challenges associated with them, summarizes key findings, and proposes possible ways forward.

commodity classification↗

Results of the Excreta Bioassay Quality Control Program for April 1, 2009 through March 31, 2010

A total of 58 urine samples and 10 fecal samples were submitted during the report period (April 1, 2009 through March 31, 2010) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238 Pu, 239 Pu, 241 Am, 243 Am 235 U, 238 U, elemental uranium and fecal analyses for 241 Am, 238 Pu and 239 Pu were tested this year as well as four tissue samples for 238 Pu, 239 Pu, 241 Am and 241 Pu. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 33% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4).

61 RADIATION PROTECTION AND DOSIMETRY↗

A taxonomy of automatic differentiation pitfalls

Automatic differentiation is a popular technique for computing derivatives of computer programs. While automatic differentiation has been successfully used in countless engineering, science, and machine learning applications, it can sometimes nevertheless produce surprising results. In this paper, we categorize problematic usages of automatic differentiation, and illustrate each category with examples such as chaos, time-averages, discretizations, fixed-point loops, lookup tables, linear solvers, and probabilistic programs, in the hope that readers may more easily avoid or detect such pitfalls. We also review debugging techniques and their effectiveness in these situations.

Autodiff↗

Analysis of Tank 23H (HTF-23-19-23, -24, -25) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 23H to support ECP and CCP. The results of the analysis indicate the concentrations of species in Tank 23H increase with depth in the tank. The sample obtained from the lowest level of 60” from the bottom of the tank shows the highest concentrations for most species analyzed. The surface sample and the 140” sub-surface sample show similar compositions with the sub-surface sample being slightly more concentrated, and both are more dilute than the lowest 60” sub-surface sample for most species analyzed. The total uranium concentration in the three Tank 23H samples show a slight increase from the surface sample to the next lower sub-surface sample, but then a slight decrease in the uranium concentration in the lowest sub-surface sample. The U-235 weight fraction ranges from 0.94-1.2% in the Tank 23H samples. The sum of the major cations versus the sum of the major anions shows a difference of ~5% or less for all three of the Tank 23H samples indicating good data quality for the non-radioactive analytes in the table. Small %RSD values for the replicate analyses with the exception of species close to the detection limit (e.g., Fe) provide another indication of good data quality for the non-radioactive species. The silicon concentrations measured in the Tank 23H samples were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Satellite orbit predictor

An analog aid to determine satellite coverage of Emergency Locator Transmitters Emergency Position Indicating Radio Beacon (ELT/EPIRB) distress incidence is discussed. The satellite orbit predictor is a graphical aid for determining the relationship between the satellite orbit, antenna coverage of the spacecraft and coverage of the Local User Terminal. The predictor allows the user to quickly visualize if a selected position will probably be detected and is composed of a base map and a satellite track overlay for each satellite.A table of equator crossings for each satellite is included.

Friedman, Morton l.↗

COSPAS-SARSAT Satellite Orbit Predictor Volume 10

The satellite orbit predictor is a graphical aid for determining the relationship between the satellite (SARSAT or COSPAS) orbit, antenna coverage of the spacecraft and coverage of the Local User Terminals. The predictor allows the user to quickly visualize if a selected position will be detected and is composed of a base map and satellite track overlay for each satellite. A table of equator crossings for each satellite is included.

Friedman, Morton L.↗

Strong magnetic fields, galaxy formation, and the Galactic engine

The strong-magnetic-field model proposed as an energy source for AGN and quasars by Greyber (1961, 1962, 1964, 1967, 1984, 1988, and 1989) is discussed. The basic principles of the model are reviewed; its advantages (in explaining the observed features of AGN and quasars) over models based on a rotating accretion disk are indicated in a table; and its implications for galaxy and quasar formation are explored. The gravitationally bound current loops detected in nearby spiral galaxies are interpreted as weak remnants of the current loops present during their formation. An observational search for a similar loop near the Galactic center is proposed.

Greyber, Howard D.↗

Data for Comparison of Genotyping Assays for Detection of Targeted CRISPR/Cas Mutagenesis in Highly Polyploid Sugarcane

Sugarcane ( Saccharum spp.) is an important biofuel feedstock and a leading source of global table sugar. Saccharum hybrid cultivars are highly polyploid (2n = 100–130), containing large numbers of functionally redundant hom(e)ologs in their genomes. Genome editing with sequence-specific nucleases holds tremendous promise for sugarcane breeding. However, identification of plants with the desired level of co-editing within a pool of primary transformants can be difficult. While DNA sequencing provides direct evidence of targeted mutagenesis, it is cost-prohibitive as a primary screening method in sugarcane and most other methods of identifying mutant lines have not been optimized for use in highly polyploid species. In this study, non-sequencing methods of mutant screening, including capillary electrophoresis (CE), Cas9 RNP assay, and high-resolution melt analysis (HRMA), were compared to assess their potential for CRISPR/Cas9-mediated mutant screening in sugarcane. These assays were used to analyze sugarcane lines containing mutations at one or more of six sgRNA target sites. All three methods distinguished edited lines from wild type, with co-mutation frequencies ranging from 2% to 100%. Cas9 RNP assays were able to identify mutant sugarcane lines with as low as 3.2% co-mutation frequency, and samples could be scored based on undigested band intensity. CE was highlighted as the most comprehensive assay, delivering precise information on both mutagenesis frequency and indel size to a 1 bp resolution across all six targets. This represents an economical and comprehensive alternative to sequencing-based genotyping methods which could be applied in other polyploid species.

Genomics↗

Comparison of genotyping assays for detection of targeted CRISPR/Cas mutagenesis in highly polyploid sugarcane

Sugarcane (Saccharum spp.) is an important biofuel feedstock and a leading source of global table sugar. Saccharum hybrid cultivars are highly polyploid (2n = 100–130), containing large numbers of functionally redundant hom(e)ologs in their genomes. Genome editing with sequence-specific nucleases holds tremendous promise for sugarcane breeding. However, identification of plants with the desired level of co-editing within a pool of primary transformants can be difficult. While DNA sequencing provides direct evidence of targeted mutagenesis, it is cost-prohibitive as a primary screening method in sugarcane and most other methods of identifying mutant lines have not been optimized for use in highly polyploid species. In this study, non-sequencing methods of mutant screening, including capillary electrophoresis (CE), Cas9 RNP assay, and high-resolution melt analysis (HRMA), were compared to assess their potential for CRISPR/Cas9-mediated mutant screening in sugarcane. These assays were used to analyze sugarcane lines containing mutations at one or more of six sgRNA target sites. All three methods distinguished edited lines from wild type, with co-mutation frequencies ranging from 2% to 100%. Cas9 RNP assays were able to identify mutant sugarcane lines with as low as 3.2% co-mutation frequency, and samples could be scored based on undigested band intensity. CE was highlighted as the most comprehensive assay, delivering precise information on both mutagenesis frequency and indel size to a 1 bp resolution across all six targets. This represents an economical and comprehensive alternative to sequencing-based genotyping methods which could be applied in other polyploid species.

60 APPLIED LIFE SCIENCES↗

Semiconductor radiation detector

A semiconductor detector for ionizing electromagnetic radiation, neutrons, and energetic charged particles. The detecting element is comprised of a compound having the composition I-III-VI.sub.2 or II-IV-V.sub.2 where the "I" component is from column 1A or 1B of the periodic table, the "II" component is from column 2B, the "III" component is from column 3A, the "IV" component is from column 4A, the "V" component is from column 5A, and the "VI" component is from column 6A. The detecting element detects ionizing radiation by generating a signal proportional to the energy deposited in the element, and detects neutrons by virtue of the ionizing radiation emitted by one or more of the constituent materials subsequent to capture. The detector may contain more than one neutron-sensitive component.

Bell, Zane W↗