Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Existence of a robust optimal control process for efficient measurements in a two-qubit system

The verification of quantum entanglement is essential for quality control in quantum communication. In this work we propose an efficient protocol to directly verify the two-qubit entanglement of a known target state through a single-expectation-value measurement. Our method provides exact entanglement quantification using the concurrence measure without performing quantum state tomography. We prove the existence of a unitary transformation that drives a known initial state of a two-qubit system to a designated final state, where the trace over a chosen observable directly yields the concurrence of the initial state. Furthermore, we implement an optimal control process of that transformation and demonstrate its effectiveness through numerical simulations. We also show that this process is robust to environmental noise. Our approach offers advantages in directly verifying entanglement with low circuit depth, making it suitable for industrial-scale quality control of entanglement generation. Our results presented here provide mathematical justification for our earlier computational experiments.

Rodriguez, Ricardo [McPherson Coll.] (ORCID:000000↗

Advanced Fluid Reduced Order Models for Compressible Flow.

This report summarizes fiscal year (FY) 2017 progress towards developing and implementing within the SPARC in-house finite volume flow solver advanced fluid reduced order models (ROMs) for compressible captive-carriage flow problems of interest to Sandia National Laboratories for the design and qualification of nuclear weapons components. The proposed projection-based model order reduction (MOR) approach, known as the Proper Orthogonal Decomposition (POD)/Least- Squares Petrov-Galerkin (LSPG) method, can substantially reduce the CPU-time requirement for these simulations, thereby enabling advanced analyses such as uncertainty quantification and de- sign optimization. Following a description of the project objectives and FY17 targets, we overview briefly the POD/LSPG approach to model reduction implemented within SPARC . We then study the viability of these ROMs for long-time predictive simulations in the context of a two-dimensional viscous laminar cavity problem, and describe some FY17 enhancements to the proposed model reduction methodology that led to ROMs with improved predictive capabilities. Also described in this report are some FY17 efforts pursued in parallel to the primary objective of determining whether the ROMs in SPARC are viable for the targeted application. These include the implemen- tation and verification of some higher-order finite volume discretization methods within SPARC (towards using the code to study the viability of ROMs on three-dimensional cavity problems) and a novel structure-preserving constrained POD/LSPG formulation that can improve the accuracy of projection-based reduced order models. We conclude the report by summarizing the key takeaways from our FY17 findings, and providing some perspectives for future work.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enhanced Sensitivity for Selected Reaction Monitoring–Mass Spectrometry-based Targeted Proteomics using a Dual-Stage Electrodynamic Ion Funnel Interface

Selected reaction monitoring-mass spectrometry (SRM-MS) is playing an increasing role in quantitative proteomics and biomarker discovery studies as a method for high throughput candidate quantification and verification. While SRM-MS offers advantages in sensitivity and quantification compared to other MS-based techniques, current SRM technologies are still challenged by detection and quantification of low-abundance proteins (e.g., present at ~10 ng/mL or lower levels in blood plasma). Here we report enhanced detection sensitivity and reproducibility for SRM-based targeted proteomics by coupling a dual electrodynamic ion funnel interface to a commercial triple quadrupole mass spectrometer. Due to the increased efficiency in ion transmission, significant enhancements in overall signal intensities and improved limits of detection were observed with the new interface compared to the original (capillary/skimmer) interface for SRM measurements of tryptic peptides from proteins spiked into non-depleted mouse plasma over a range of concentrations. Overall, average SRM peak intensities were increased by ~70-fold. The average level of detection for peptides also improved by ~14-fold, with notably improved reproducibility of peptide measurements as indicated by the reduced coefficients of variance. The ability to detect proteins ranging from 40 to 80 ng/mL within mouse plasma was demonstrated for all spiked proteins without the application of front-end immunoaffinity depletion and fractionation. This significant improvement in detection sensitivity for low-abundance proteins in complex matrices is expected to enhance a broad range of SRM-MS applications in addition to targeted protein and metabolite validation.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Uncertainty Quantification in Fission Cross Section Measurements at LANSCE

Neutron-induced fission cross sections have been measured for several isotopes of uranium and plutonium at the Los Alamos Neutron Science Center (LANSCE) over a wide range of incident neutron energies. The total uncertainties in these measurements are in the range 3–5% above 100 keV of incident neutron energy, which results from uncertainties in the target, neutron source, and detector system. The individual sources of uncertainties are assumed to be uncorrelated, however correlation in the cross section across neutron energy bins are considered. The quantification of the uncertainty contributions will be described here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification in Scale-Dependent Models of Flow in Porous Media

Equations governing flow and transport in heterogeneous porous media are scale-dependent. We demonstrate that it is possible to identify a support scale $\eta^*$, such that the typically employed approximate formulations of Moment Equations (ME) yield accurate (statistical) moments of a target environmental state variable. Under these circumstances, the ME approach can be used as an alternative to the Monte Carlo (MC) method for Uncertainty Quantification in diverse fields of Earth and environmental sciences. MEs are directly satisfied by the leading moments of the quantities of interest and are defined on the same support scale as the governing stochastic partial differential equations (PDEs). Computable approximations of the otherwise exact MEs can be obtained through perturbation expansion of moments of the state variables in orders of the standard deviation of the random model parameters. As such, their convergence is guaranteed only for the standard deviation smaller than one. Furthermore, we demonstrate our approach in the context of steady-state groundwater flow in a porous medium with a spatially random hydraulic conductivity.

42 ENGINEERING↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of anti-CRISPR protein AcrIIA4 as a capture ligand for CRISPR/Cas9 detection

The clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 9 (Cas9) ribonucleoprotein (RNP) complex is an RNA-guided DNA-nuclease that is part of the bacterial adaptive immune system. CRISPR/Cas9 RNP has been adapted for targeted genome editing within cells and whole organisms with new applications vastly outpacing detection and quantification of gene-editing reagents. Detection of the CRISPR/Cas9 RNP within biological samples is critical for assessing gene-editing reagent delivery efficiency, retention, persistence, and distribution within living organisms. Conventional detection methods are effective, yet the expense and lack of scalability for antibody-based affinity reagents limit these techniques for clinical and/or field settings. This necessitates the development of low cost, scalable CRISPR/Cas9 RNP affinity reagents as alternatives or augments to antibodies. Herein, we report the development of the Streptococcus pyogenes anti-CRISPR/Cas9 protein, AcrIIA4, as a novel affinity reagent. An engineered cysteine linker enables covalent immobilization of AcrIIA4 onto glassy carbon electrodes functionalized via aryl diazonium chemistry for detection of CRISPR/Cas9 RNP by electrochemical, fluorescent, and colorimetric methods. Electrochemical measurements achieve a detection of 280 pM RNP in reaction buffer and 8 nM RNP in biologically representative conditions. Our results demonstrate the ability of anti-CRISPR proteins to serve as robust, specific, flexible, and economical recognition elements in biosensing/quantification devices for CRISPR/Cas9 RNP.

59 BASIC BIOLOGICAL SCIENCES↗

Single Molecule Kinetics of ENTH Binding to Lipid Membranes

Transient recruitment of proteins to membranes is a fundamental mechanism by which the cell exerts spatial and temporal control over proteins’ localization and interactions. Thus, the specificity and the kinetics of peripheral proteins’ membrane residence are an attribute of their function. In this article, we describe the membrane interactions of the interfacial epsin N-terminal homology (ENTH) domain with its target lipid phosphatidylinositol (4,5)-bisphosphate (PtdIns(4,5)P 2 ). The direct visualization and quantification of interactions of single ENTH molecules with supported lipid bilayers is achieved using total internal reflection fluorescence microscopy (TIRFM) with a time resolution of 13 ms. This enables the recording of the kinetic behavior of ENTH interacting with membranes with physiologically relevant concentrations of PtdIns(4,5)P 2 despite the low effective binding affinity. Subsequent single fluorophore tracking permits us to build up distributions of residence times and to measure ENTH dissociation rates as a function of membrane composition. In addition, due to the high time resolution, we are able to resolve details of the motion of ENTH associated with a simple, homogeneous membrane. In this case ENTH’s diffusive transport appears to be the result of at least three different diffusion processes.

membrane-protein interactions↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency).

Per- and poly-fluorinated alkyl substances (PFAS),↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Quantification of uncertainty in photon source spot size inference during laser-driven radiography experiments at TRIDENT

Images of the R2DTO resolution target were obtained during laser-driven-radiography experiments performed at the TRIDENT laser facility, and analysis of these images using the Bayesian Inference Engine (BIE) determines a most probable full-width half maximum (FWHM) spot size of 78 μm. However, significant uncertainty prevails due to variation in the measured detector blur. Propagating this uncertainty in detector blur through the forward model results in an interval of probabilistic ambiguity spanning approximately 35-195 μm when the laser energy impinges on a thick (1 mm) tantalum target. In other phases of the experiment, laser energy is deposited on a thin (~100 nm) aluminum target placed 250 μm ahead of the tantalum converter. When the energetic electron beam is generated in this manner, upstream from the bremsstrahlung converter, the inferred spot size shifts to a range of much larger values, approximately 270-600 μm FWHM. This report discusses methods applied to obtain these intervals as well as concepts necessary for interpreting the result within a context of probabilistic quantitative inference.

47 OTHER INSTRUMENTATION↗

Reducing Direct Drive Preheat with Dopants

Preheat in laser-driven experiments can have negative impacts on inertial confinement fusion (ICF) and hydrodynamic experiments. While many groups employ the use of dopants to reduce or block preheat, direct quantification has not previously been explored. We developed a planar platform and a series of ablator targets to measure the electron and x-ray spectra generated by laser-plasma interactions with a direct drive using OMEGA-60. By comparing both thin ablators (75 μm) and thick ablators (270 μm) that were either pure CH, 3% Si doped or 3% I doped, we were able to measure differences in electron and x-ray spectra. In addition, we observed the preheat growth of tracer layers and observed reductions in the growth with different materials. We find that iodine or a thin gold layer is the best at tamping the direct-drive preheat at OMEGA, but that the growth is still significant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved electrical mobility in highly epitaxial La:BaSnO{sub 3} films on SmScO{sub 3}(110) substrates

Heteroepitaxial growth of BaSnO{sub 3} and Ba{sub 1−x}La{sub x}SnO{sub 3} (x = 7%) lanthanum doped barium stannate thin films on different perovskite single crystal (SrTiO{sub 3} (001) and SmScO{sub 3} (110)) substrates has been achieved by pulsed laser deposition under optimized deposition conditions. X-ray diffraction measurements indicate that the films on either of these substrates are relaxed due to the large mismatch and present a high degree of crystallinity with narrow rocking curves and smooth surface morphology while analytical quantification by proton induced X-ray emission confirms the stoichiometric La transfer from a polyphasic target, producing films with measured La contents above the bulk solubility limit. The films show degenerate semiconducting behavior on both substrates, with the observed room temperature resistivities, Hall mobilities, and carrier concentrations of 4.4 mΩ cm, 10.11 cm{sup 2} V{sup −1} s{sup −1}, and 1.38 × 10{sup 20} cm{sup −3} on SmScO{sub 3} and 7.8 mΩ cm, 5.8 cm{sup 2} V{sup −1} s{sup −1}, and 1.36 × 10{sup 20} cm{sup −3} on SrTiO{sub 3} ruling out any extrinsic contribution from the substrate. The superior electrical properties observed on the SmScO{sub 3} substrate are attributed to reduction in dislocation density from the lower lattice mismatch.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of the frequency and nature of erroneous x-ray photoelectron spectroscopy analyses in the scientific literature

Here, this study was undertaken to understand the extent and nature of problems in x-ray photoelectron spectroscopy (XPS) data reported in the literature. It first presents an assessment of the XPS data in three high-quality journals over a six-month period. This analysis of 409 publications showing XPS spectra provides insight into how XPS is being used, identifies the common mistakes or errors in XPS analysis, and reveals which elements are most commonly analyzed. More than 65% of the 409 papers showed fitting of XP spectra. An ad hoc group (herein identified as “the committee”) of experienced XPS analysts reviewed these spectra and found that peak fitting was a common source of significant errors. The papers were ranked based on the perceived seriousness of the errors, which ranged from minor to major. Major errors, which, in the opinion of the ad hoc committee, can render the interpretation of the data meaningless, occurred when fitting protocols ignored underlying physics and chemistry or contained major errors in the analysis. Consistent with other materials analysis data, ca. 30% of the XPS data or analysis was identified as having major errors. Out of the publications with fitted spectra, ca. 40% had major errors. The most common elements analyzed by XPS in the papers sampled and researched at an online database, include carbon, oxygen, nitrogen, sulfur, and titanium. A scrutiny of the papers showing carbon and oxygen XPS spectra revealed the classes of materials being studied and the extent of problems in these analyses. As might be expected, C 1s and O 1s analyses are most often performed on sp2-type materials and inorganic oxides, respectively. These findings have helped focus a series of XPS guides and tutorials that deal with common analysis issues. The extent of problematic data is larger than the authors had expected. Quantification of the problem, examination of some of the common problem areas, and the development of targeted guides and tutorials may provide both the motivation and resources that enable the community to improve the overall quality and reliability of XPS analysis reported in the literature.

Major, George H.↗

Matilda v1.0: An R package for probabilistic climate projections using a reduced complexity climate model

A primary advantage to using reduced complexity climate models (RCMs) has been their ability to quickly conduct probabilistic climate projections, a key component of uncertainty quantification in many impact studies and multisector systems. Providing frameworks for such analyses has been a target of several RCMs used in studies of the future co-evolution of the human and Earth systems. In this paper, we present Matilda, an open-science R software package that facilitates probabilistic climate projection analysis, implemented here using the Hector simple climate model in a seamless and easily applied framework. The primary goal of Matilda is to provide the user with a turn-key method to build parameter sets from literature-based prior distributions, run Hector iteratively to produce perturbed parameter ensembles (PPEs), weight ensembles for realism against observed historical climate data, and compute probabilistic projections for different climate variables. This workflow gives the user the ability to explore viable parameter space and propagate uncertainty to model ensembles with just a few lines of code. The package provides significant freedom to select different scoring criteria and algorithms to weight ensemble members, as well as the flexibility to implement custom criteria. Additionally, the architecture of the package simplifies the process of building and analyzing PPEs without requiring significant programming expertise, to accommodate diverse use cases. We present a case study that provides illustrative results of a probabilistic analysis of mean global surface temperature as an example of the software application.

54 ENVIRONMENTAL SCIENCES↗

Model-based image change quantification

A system is provided for identifying and quantizing a change in a scene having objects based on comparison of features representing a target object derived from a first image and a second image that includes the target object. The system segments, based on a scene model of the scene, a second image that includes the target object to identify a second area representing the target object within the second image. The system extracts, from the second image, second features for the target object based on the second area. The system determines a second effectiveness of the second features indicating effectiveness of the second features in representing the target object. The system detects a change based on a difference between first features and the second features factoring in a first effectiveness and the second effectiveness.

Roberts, Randy S.↗

Multiscale-Informed Modeling of High Temperature Component Response with Uncertainty Quantification

This report summarizes a joint effort between Argonne National Laboratory, Idaho National Laboratory, and Los Alamos National Laboratory to develop and deploy constitutive models targeted at predicting the life of Grade 91 alloy components subjected to high temperature environments typical of those that structural components in advanced nuclear reactors would experience. Two distinct, but complementary constitutive modeling approaches have been taken here. The first employs a phenomenological viscoplastic model for which parameters have been calibrated based on experimental data for a wide range of Grade 91 alloy that has undergone a variety of processing. A Bayesian approach was used to derive distributions of uncertain parameters for this model based on this data set. The second approach is a reduced order model suitable for engineering-scale analysis that is based on the results of a large set of mesoscale simulations. Mesoscale models allow for the microstructure and composition of a particular alloy to be directly taken into account in the computation of the viscoplastic response, but are computationally expensive, which makes it impractical to directly call those models for the material constitutive response in an engineering-scale simulation. The reduced-order representation of the response of the underlying model used here allows for an engineering-scale model to take into account the characteristics of the underlying microstructure, while only incurring a reasonable computational expense. Both of these approaches have different strengths, and are applicable for different parts of the design/analysis process. The phenomenological models can be readily parameterized based on a set of experimental data for a given class of materials and used for scoping calculations. Once a specific material is chosen and adequately characterized, the reduced order models can accurately predict the response of that specific alloy, and because the models are based on predictive models of the underlying microstructure, they can be used to more confidently predict the response under conditions in regions where there is limited experimental data. Both of these models have been integrated in the Grizzly code, which is used here to perform proof-of-concept uncertainty quantification analyses of a simple component under prototypical conditions. The built- in stochastic analysis capabilities in the MOOSE framework that Grizzly is built on are used here to run large sets of simulations for this uncertainty quantification analysis. As would be expected, because the reduced order models are developed for a much more tightly defined alloy, they predict tighter distributions of the time to failure than the phenomenological models, which are calibrated to a broader set of data. Also important is that these simulations demonstrate that a reduced order modeling approach can be successfully deployed to propagate uncertainties from the material scale to practical engineering-scale component simulations.

42 ENGINEERING↗