Search NASA⌕ Search

SEARCH · Search NASA

Results for “technical potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of Supply Chains and Advanced Manufacturing of Small Hydropower Systems

Clean energy manufacturing is a sector of increasing importance both in the United States and worldwide. In the United States, it has been presented as an engine for job creation in a sector of the U.S. economy that was hit hard by the 2008-2009 recession. The Clean Energy Manufacturing Analysis Center (CEMAC), sponsored by the U.S. Department of Energy (DOE), conducts credible, objective, industry-relevant, recurring, and consistent analyses of clean energy technologies. In this project, the National Renewable Energy Laboratory (NREL) and the Oak Ridge National Laboratory (ORNL) collaborated in a hydropower manufacturing and supply chain analysis primarily for U.S. small hydropower (SHP) market to provide insights on supply chain constraints, manufacturing cost, location factors, and opportunities for hydropower using advanced manufacturing technologies. The goal of the project is to improve understanding of the manufacturing opportunities in the U.S. hydropower supply chain, specific competitive advantages, and factors for manufacturing location decisions for SHP. These insights could be used to inform investment and research strategies, policy, and other decisions that could promote economic growth and strengthen U.S. manufacturing capabilities. The project scope included a design for manufacturing and assembly (DFMA) costs analysis and a levelized cost of electricity (LCOE) sensitivity analysis of modular, representative SHP turbines. A representative SHP system was chosen to be made up of two 5 megawatt (MW) turbines, as these Kaplan style turbines could be useable for many non-powered dams (NPDs) across the U.S. The sensitivity analysis used the Integrated Design and Assessment (IDEA) tool, which has helped highlight the impact of the turbine equipment cost on the potential capital expenditure (CAPEX) and LCOE of the installed, representative system. In addition, the project team analyzed international tradeflows (e.g., export and import of hydropower turbines and the parts used in hydropower systems). As part of this project, hydropower stakeholder interviews were undertaken to help identify insights related to hydropower manufacturing opportunities for U.S. players in SHP, the country-specific manufacturing advantages in the United States and threats, and key factors behind manufacturing location decisions made by the SHP industry. Key opportunities for the US SHP market and industry include: Foreign export markets such as Chile, China, Columbia, India and Japan, have an estimated 71,795 MW of technical potential that could be serviced with SHP installations. Utilization of existing manufacturing capacity and expertise, along with economies of scale benefits, could result in increased global competitiveness through lower investment requirements and component costs, which could lead to increased U.S. strength in the export of SHP systems and components. Technology advances such as modular turbine designs, standardized units for conduit systems, precast systems, and improved powertrain technologies could help reduce costs, particularly for manufacturing a small number of units. The DOE is also exploring modular hydropower designs, which would integrate standard independently-produced components, validated to meet multiple specifications. Using modules in product design simplifies manufacturing activities such as inspection, testing, assembly, and purchasing, may increase economies of scale to lower total system cost. There are significant opportunities for the use of composites and Additive Manufacturing (AM) for hydropower components, when design changes are made to hydropower systems. By taking advantage of the corrosion resistance, light-weighting and structural benefits, composites and AM could help significantly alter hydropower structures and installations.

13 HYDRO ENERGY↗

Performance Assessment of a Photonic Radiative Cooling System for Office Buildings

Spectrally selective materials show high technical potential for use as radiative cooling heat exchangers for buildings. Recent work by Stanford University has applied a photonic approach to tailor the optical properties of a coating material. In a prototype test, a radiative cooler based on that photonic material has demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. This paper presents the simulation and parametric analysis of photonic radiative cooling system that integrates the use of the photonic radiative cooler and radiant floor cooling via the whole energy simulation program EnergyPlus. The simulation was made for a medium office building with three floors and a total floor area of 5,000 m2. Three key design parameters including the storage tank size, the radiator area, and the number of floors are expected to have a large impact on system performance were investigated in this paper. The results show that the percentage of cooling electricity savings from the photonic radiative cooling system relative to a reference variable-air-volume system has a linear relationship with the radiator area, and a quadratic correlation with both tank size and the number of floors. The findings from this parametric analysis are valuable to understand how component sizing affects system performance.

Wang, Weimin↗

Trade Space Assessment for Human Exploration Mission Design

Many human space exploration mission architecture assessments have been performed over the years by diverse organizations and individuals. Direct comparison of metrics among these studies is extremely difficult due to widely varying assumptions involving projected technology readiness, mission goals, acceptable risk criteria, and socio-political environments. However, constant over the years have been the physical laws of celestial dynamics and rocket propulsion systems. A finite diverse yet finite architecture trade space should exist which captures methods of human exploration - particularly of the Moon and Mars - by delineating technical trades and cataloging the physically realizable options of each. A particular architectural approach should then have a traceable path through this "trade tree". It should be pointed out that not every permutation of paths will result in a physically realizable mission approach, but cataloging options that have been examined by past studies should help guide future analysis. This effort was undertaken in two phases by multi-center NASA working groups in the spring and summer of 2004 using more than thirty years of past studies to "flesh out" the Moon-Mars human exploration trade space. The results are presented, not as a "trade tree", which would be unwieldy, but as a "menu" of potential technical options as a function of mission phases. This is envisioned as a tool to aid future mission designers by offering guidance to relevant past analyses.

Joosten, B. Kent↗

The Realistic Potential of Soil Carbon Sequestration in U.S. Croplands for Climate Mitigation

Existing estimates of the climate mitigation potential from cropland carbon sequestration (C-sequestration) are limited because they tend to assume constant rates of soil organic carbon change over all available cropland area, use relatively coarse land delineations, and often fail to adequately consider the agronomic and socioeconomic dimensions of agricultural land use. This results in an inflated estimate of the C-sequestration potential. We address this gap by defining a more appropriate land base for cover cropping in the United States for C-sequestration purposes: stable croplands in annual production systems that can integrate cover cropping without irrigation. Our baseline estimate of this suitable stable cropland area is 32% of current U.S. cropland extent. Even an alternative, less restrictive definition of stability results in a large reduction in area (44% of current U.S. croplands). Focusing cover crop implementation to this constrained land base would increase durability of associated C-sequestration and limit soil carbon loss from land conversion to qualify for carbon-specific incentives. Applying spatially-variable C-sequestration rates from the literature to our baseline area yields a technical potential of 19.4 Tg CO 2 e yr –1 annually, about one-fifth of previous estimates. We also find the cost of realizing about half (10 Tg CO 2 e yr –1 ) of this potential could exceed 100 USD Mg CO 2 e –1 , an order of magnitude higher than previously thought. While our economic analyses suggest that financial incentives are necessary for large-scale adoption of cover cropping in the U.S., they also imply any C-sequestration realized under such incentives is likely to be additional.

54 ENVIRONMENTAL SCIENCES↗

Space Shuttle SRM performance improvement

A number of options for Solid Rocket Motor (SRM) performance improvement were studied and evaluated by NASA with respect to payload improvement potential, technical risk, schedule, cost, and impact on Shuttle system performance. It was found that the SRM delivered specific impulse could be improved by increasing the nozzle expansion ratio from 7.16 to 7.72. This was achieved by decreasing the throat diameter of the nozzle exit cone, while staying within tooling, facility, and ICD limitations. A simple modification of the grain inhibiting pattern was made to reshape the thrust-time history and thereby obtain more delivered impulse during the early portion of motor operation. These performance options, initiated in October 1980, provide a 3,000 lb payload increase. Longer range options are the use of a filament wound composite case, a HTPB propellant, and further increases in the nozzle expansion ratio. These improvements have a potential of 10,000 to 11,000 lb payload increase.

Speak, C. A.↗

Aquapv

This project brings together a multidisciplinary team to develop tools and analysis that will help U.S. industry accelerate deployment of floating PV on reservoirs and estuaries through producing: • A tool to assess potential environmental interactions of FPV on reservoirs and estuaries and thresholds for corresponding impacts. • A tailored FPV-specific techno-economic tool to guide users on financial performance and corresponding design considerations. • A synthesized tool, AquaPV, that combines the environmental and economic tools. • A set of case studies on an open-loop reservoir with a traditional hydropower plant (i.e., connected to a natural waterbody), closed-loop reservoir with a proposed pumped storage hydropower plant (i.e., manmade and disconnected from a natural waterbody), and a marine estuary (i.e., where a river meets the ocean), with an FPV system designed and modeled for each site. • A review of regulatory, environmental, and stakeholder opportunities and challenges to identify clear regulatory and environmental pathways to siting FPV on U.S. reservoirs. • A novel, high-fidelity geospatial resource assessment to estimate FPV technical potential on reservoirs in the United States.

Phillips, TylerB. [Idaho National Laboratory (INL)↗

Comparing vis–NIRS, LIBS, and Combined vis–NIRS‐LIBS for Intact Soil Core Soil Carbon Measurement

Core Ideas First rigorous integration of VisNIR and LIBS spectroscopic techniques for soil profile C measurement. Field‐moist intact soil cores scanned with LIBS and VisNIR simulating in situ measurements. Combined VisNIR‐LIBS wavelengths selected by MRCE were split nearly equally between sensors, suggesting molecular and elemental information was successfully integrated for predicting TC, IC, and SOC. Stoichiometric relationships in LIBS elemental emissions are more strongly correlated to IC concentration than were carbonate absorptions in VisNIR. Lack of variation and consistent, definable chemical composition and stoichiometry likely contributed to poor LIBS and combined VisNIR – LIBS prediction accuracy for SOC. Soil organic carbon (SOC) measurement is critically important to quantify regional and global soil C stocks and better understand soil C biogeochemical processes. Recent studies employing laser‐induced breakdown spectroscopy (LIBS) and visible‐near infrared diffuse reflectance spectroscopy (vis–NIRS) indicate their potential for in situ soil C determination. Visible and near infrared diffuse reflectance spectroscopy and LIBS spectroscopy fundamentally differ and we hypothesize that their integration would provide improved soil C predictions. We report the first rigorous integration of vis–NIRS and LIBS, evaluating the precision of vis–NIRS, LIBS, and combined vis–NIRS‐LIBS spectra for simulated in situ soil profile total C (TC), inorganic C (IC) and SOC measurement. Three multivariate variable selection and regression approaches were evaluated for soil C prediction. The highest soil C prediction accuracies were observed using multivariate regression with covariance estimation (MRCE). Inorganic C was best predicted by LIBS, vis–NIRS provided better SOC predictions, and TC was best predicted using combined vis–NIRS‐LIBS data. Combined vis–NIRS‐LIBS did not consistently increase soil C prediction accuracy. Soil organic C was not well predicted, presumably due to challenges associated with scanning surfaces of intact soil cores, variable SOC chemistries, and low SOC variation in the dataset. Considering the challenging conditions under which combined vis–NIRS– LIBS was tested for soil C measurement, data integration and model calibrations had acceptable performance. Further testing under more controlled soil conditions with samples containing greater SOC diversity is necessary to determine the technical potential of combined vis–NIRS/LIBS for soil C determination.

Bricklemyer, Ross S.↗

Enhanced triboelectrification of the polydimethylsiloxane surface by ultraviolet irradiation

Study of the triboelectric charging effect has recently gained much attraction by proposing a new potential technical application in the field of energy harvesting. Transparent polydimethylsiloxane (PDMS) has some advantages in employing the triboelectric effect due to good conformity at nanometer scale and the simple fabrication process. In this study, we demonstrate that UV irradiation can enhance the performance of a PDMS-based nanotribogenerator. Contact atomic force microscopy combined with Kelvin probe force microscopy enables an in-depth investigation of the effect of UV illumination on local triboelectric charge generation and its decay in PDMS. We found that UV exposure not only facilitates triboelectric charge generation but also enhances charge redistribution, which is related to the wettability of the PDMS surface. This study provides insights into the fundamental understanding and design of triboelectric generator devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Building Commissioning: A Golden Opportunity for Reducing Energy Costs and Greenhouse-gas Emissions

The aim of commissioning new buildings is to ensure that they deliver, if not exceed, the performance and energy savings promised by their design. When applied to existing buildings, commissioning identifies the almost inevitable 'drift' from where things should be and puts the building back on course. In both contexts, commissioning is a systematic, forensic approach to quality assurance, rather than a technology per se. Although commissioning has earned increased recognition in recent years - even a toehold in Wikipedia - it remains an enigmatic practice whose visibility severely lags its potential. Over the past decade, Lawrence Berkeley National Laboratory has built the world's largest compilation and meta-analysis of commissioning experience in commercial buildings. Since our last report (Mills et al. 2004) the database has grown from 224 to 643 buildings (all located in the United States, and spanning 26 states), from 30 to 100 million square feet of floorspace, and from $17 million to $43 million in commissioning expenditures. The recorded cases of new-construction commissioning took place in buildings representing $2.2 billion in total construction costs (up from 1.5 billion). The work of many more commissioning providers (18 versus 37) is represented in this study, as is more evidence of energy and peak-power savings as well as cost-effectiveness. We now translate these impacts into avoided greenhouse gases and provide new indicators of cost-effectiveness. We also draw attention to the specific challenges and opportunities for high-tech facilities such as labs, cleanrooms, data centers, and healthcare facilities. The results are compelling. We developed an array of benchmarks for characterizing project performance and cost-effectiveness. The median normalized cost to deliver commissioning was $0.30/ft2 for existing buildings and $1.16/ft2 for new construction (or 0.4% of the overall construction cost). The commissioning projects for which data are available revealed over 10,000 energy-related problems, resulting in 16% median whole-building energy savings in existing buildings and 13% in new construction, with payback time of 1.1 years and 4.2 years, respectively. In terms of other cost-benefit indicators, median benefit-cost ratios of 4.5 and 1.1, and cash-on-cash returns of 91% and 23% were attained for existing and new buildings, respectively. High-tech buildings were particularly cost-effective, and saved higher amounts of energy due to their energy-intensiveness. Projects with a comprehensive approach to commissioning attained nearly twice the overall median level of savings and five-times the savings of the least-thorough projects. It is noteworthy that virtually all existing building projects were cost-effective by each metric (0.4 years for the upper quartile and 2.4 years for the lower quartile), as were the majority of new-construction projects (1.5 years and 10.8 years, respectively). We also found high cost-effectiveness for each specific measure for which we have data. Contrary to a common perception, cost-effectiveness is often achieved even in smaller buildings. Thanks to energy savings valued more than the cost of the commissioning process, associated reductions in greenhouse gas emissions come at 'negative' cost. In fact, the median cost of conserved carbon is negative - -$110 per tonne for existing buildings and -$25/tonne for new construction - as compared with market prices for carbon trading and offsets in the +$10 to +$30/tonne range. Further enhancing the value of commissioning, its non-energy benefits surpass those of most other energy-management practices. Significant first-cost savings (e.g., through right-sizing of heating and cooling equipment) routinely offset at least a portion of commissioning costs - fully in some cases. When accounting for these benefits, the net median commissioning project cost was reduced by 49% on average, while in many cases they exceeded the direct value of the energy savings. Commissioning also improves worker comfort, mitigates indoor air quality problems, increases the competence of in-house staff, plus a host of other non-energy benefits. These findings demonstrate that commissioning is arguably the single-most cost-effective strategy for reducing energy, costs, and greenhouse gas emissions in buildings today. Energy savings tend to persist well over at least a 3- to 5-year timeframe, but data over longer time horizons are not available. It is thus important to 'Trust but Verify,' and indeed the field is moving towards a monitoring-based paradigm in which instrumentation is used not only to confirm savings, but to identify opportunities that would otherwise go undetected. On balance, we view the findings here as conservative, in the sense that they underestimate the actual performance of projects when all costs and benefits are considered. They underestimate the technical potential for a scenario in which best practices are applied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Materials Perspective on Direct Recycling of Lithium-Ion Batteries: Principles, Challenges and Opportunities

As the dominant means of energy storage technology today, the widespread deployment of lithium-ion batteries (LIBs) would inevitably generate countless spent batteries at their end of life. From the perspectives of environmental protection and resource sustainability, recycling is a necessary strategy to manage end-of-life LIBs. Compared with traditional hydrometallurgical and pyrometallurgical recycling methods, the emerging direct recycling technology, rejuvenating spent electrode materials via a non-destructive way, has attracted rising attention due to its energy efficient processes along with increased economic return and reduced CO 2 footprint. This review investigates the state-of-the-art direct recycling technologies based on effective relithiation through solid-state, aqueous, eutectic solution and ionic liquid mediums and thoroughly discusses the underlying regeneration mechanism of each method regarding different battery chemistries. It is concluded that direct regeneration can be a more energy-efficient, cost-effective, and sustainable way to recycle spent LIBs compared with traditional approaches. Additionally, it is also identified that the direct recycling technology is still in its infancy with several fundamental and technological hurdles such as efficient separation, binder removal and electrolyte recovery. Finally, in addressing these remaining challenges, this review proposes an outlook on potential technical avenues to accelerate the development of direct recycling toward industrial applications.

25 ENERGY STORAGE↗

Imaging of Acute Traumatic Aortic Injury

Purpose of Review: This article aims to review the key aspects of the imaging evaluation of acute traumatic aortic injury (ATAI) with an emphasis on factors that affect management of these patients. Recent Findings: In the setting of trauma, the chest radiograph typically serves as the initial imaging evaluation and can be useful in detecting signs of mediastinal hematoma. In the current era, definitive diagnosis of ATAI is made with computed tomography (CT), where indirect and direct findings of ATAI can enable a confident diagnosis. Knowledge of potential technical and anatomic CT imaging pitfalls can prevent misdiagnosis of ATAI. Summary: Diagnosis of ATAI in the setting of blunt or penetrating trauma relies heavily on timely and accurate imaging interpretation. Once the diagnosis is made, a meaningful report including appropriate descriptors of the characteristics and location of ATAI should be generated by the radiologist to help direct management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Turbine scale and siting considerations in wind plant layout optimization and implications for capacity density

Improvements in wind energy technology, reduced costs, and ambitious clean energy goals have led to projections of high wind contribution in coming years. Developing methodologies to design wind plants with a variety of siting constraints and turbine sizes helps enable high wind penetration, and gain a better understanding of how wind plants are sensitive to setback constraints and turbine design. In this paper, we present a two-step optimization method to simultaneously determine the optimal number of turbines and their locations in a wind plant domain divided into many small, discrete parcels. We present the optimized performance metrics of a wind plant optimized with different turbine sizes and ratings, and with different siting restrictions within the wind plant. Our results indicate that taller and larger turbines are more sensitive to increasing siting constraints. We also compare the optimal wind plant layouts and performance for wind plants optimized for minimum COE and maximum profit. Wind plants optimized for profit had 130%-190% of the capacity of plants optimized for COE, which demonstrates that the optimal results are greatly affected by the objective function, which should be carefully considered. Finally, in this paper we demonstrate the effect of increasing siting constraints on wind plant capacity density, and how the results change when different land areas are used to calculate capacity density. When using the entire wind plant boundary area to determine capacity density, increasing siting constraints decreases the capacity density. However, when we only use the available area (the area left after removing the siting constraints) to calculate the capacity density, increasing the siting constraints increases capacity density. This is a critical insight because of how capacity density is typically defined and used in research, and has important implications for assessment of technical potential and capacity expansion modeling, as well as future wind deployment potential.

17 WIND ENERGY↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

Energy efficiency as a means to expand energy access: A Uganda roadmap

While energy efficiency can contribute significantly towards improving access to modern energy services, energy sector investments in many developing countries have largely focused on increasing energy access by increasing supply. This is because the links between energy efficiency and energy access, is often overlooked. This oversight of energy efficiency is frequently a missed opportunity, as efficiency is often a very cost-effective energy resource. In combination with grid expansion and new clean energy generation, efficiency efforts can help to ensure that reliable power is provided to the maximum number of customers at a lower cost than would be required to increase generation alone. Here in this paper we describe an analysis method for determining a country's energy efficiency priorities and devising an action plan to integrate energy efficiency as a resource for meeting a nation's energy access goals. We illustrate this method with a detailed case study of Uganda. If the most efficient technologies on the market were adopted in Uganda, 442 MW of generation-level demand could be offset and energy access for an additional 6 M rural customers could be achieved by 2030. Of this technical potential for efficiency, 91% is cost-effective, and 47% is economically achievable under conservative assumptions.

Sub-Saharan Africa↗

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building and grid system benefits of demand flexibility and energy efficiency

The global electricity system is undergoing a dramatic transformation. Technology advancements in clean energy generation (e.g., solar photovoltaics and wind) and electrified demand (e.g., transportation and building heating) are providing a cost-competitive pathway to mitigate the urgent and severe consequences associated with a changing climate. In addition, as extreme events continue to increase in frequency and magnitude, solutions are needed for adapting to the current climate. Through energy efficiency and demand flexibility, buildings play a prominent role in meeting these challenges; recently in Joule, a paper by Langevin et al. provides clear insight into the magnitude of buildings’ technical potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗