Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hard x-ray photoelectron spectroscopy: a snapshot of the state-of-the-art in 2020

Hard X-ray photoelectron spectroscopy (HAXPES) is establishing itself as an essential technique for the characterisation of materials. The number of specialised photoelectron spectroscopy techniques making use of hard X-rays is steadily increasing and ever more complex experimental designs enable truly transformative insights into the chemical, electronic, magnetic, and structural nature of materials. This paper begins with a short historic perspective of HAXPES and spans from developments in the early days of photoelectron spectroscopy to provide an understanding of the origin and initial development of the technique to state-of-the-art instrumentation and experimental capabilities. The main motivation for and focus of this paper is to provide a picture of the technique in 2020, including a detailed overview of available experimental systems worldwide and insights into a range of specific measurement modi and approaches. Herein, we also aim to provide a glimpse into the future of the technique including possible developments and opportunities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The SuperCam Instrument Suite on the Mars 2020 Rover: Science Objectives and Mast-Unit Description

On the NASA 2020 rover mission to Jezero crater, the remote determination of the texture, mineralogy and chemistry of rocks is essential to quickly and thoroughly characterize an area and to optimize the selection of samples for return to Earth. As part of the Perseverance payload, SuperCam is a suite of five techniques that provide critical and complementary observations via Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), visible and near-infrared spectroscopy (VISIR), high-resolution color imaging (RMI), and acoustic recording (MIC). SuperCam operates at remote distances, primarily 2–7 m, while providing data at sub-mm to mm scales. We report on SuperCam’s science objectives in the context of the Mars 2020 mission goals and ways the different techniques can address these questions. The instrument is made up of three separate subsystems: the Mast Unit is designed and built in France; the Body Unit is provided by the United States; the calibration target holder is contributed by Spain, and the targets themselves by the entire science team. This publication focuses on the design, development, and tests of the Mast Unit; companion papers describe the other units. The goal of this work is to provide an understanding of the technical choices made, the constraints that were imposed, and ultimately the validated performance of the flight model as it leaves Earth, and it will serve as the foundation for Mars operations and future processing of the data.

47 OTHER INSTRUMENTATION↗

Advanced Method Optimization with Categorical and Constrained Continuous Parameters

Traditional approaches to analytical method optimization (e.g., univariate and “guess-and-check”) can be time-consuming, costly, and often fail to identify true optima within the parameter space. Previous work defined and implemented a generalized technique for method optimization for continuous method parameters, but a knowledge gap remains for the incorporation of categorical variables into these advanced method optimization schemes. This work presents and validates a generalized optimization approach that incorporates both continuous and categorical variables while also utilizing a multivariate, multiobjective optimization scheme with Karush–Kuhn–Tucker conditions to bound the optimization space to solutions within the physical limitations of the parameter space. Method optimization from a case study using GC–MS for the analysis of 11 analytical standards with objectives to minimize peak width and maximize peak height resulted in a 3 orders of magnitude improvement in the average peak height and a 2 orders of magnitude improvement in the average peak width compared to the least optimal (but reasonable) instrumental parameters utilized in this study. This approach to optimization allows for a customizable method optimization in which users can include both continuous and categorical variables to achieve objectives specific to their analytical goals. This approach significantly reduces the labor and cost associated with traditional method development approaches and can be applied in a variety of scientific fields across a range of laboratory techniques (e.g., instrument method development, sample preparation, and extraction techniques).

Amorphous materials↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Automatic inspection of program state in an uncooperative environment

Abstract The program state is formed by the values that the program manipulates. These values are stored in the stack, in the heap, or in static memory. The ability to inspect the program state is useful as a debugging or as a verification aid. Yet, there exists no general technique to insert inspection points in type‐unsafe languages such as C or C++. The difficulty comes from the need to traverse the memory graph in a so‐called uncooperative environment. In this article, we propose an automatic technique to deal with this problem. We introduce a static code transformation approach that inserts in a program the instrumentation necessary to report its internal state. Our technique has been implemented in LLVM. It is possible to adjust the granularity of inspection points trading precision for performance. In this article, we demonstrate how to use inspection points to debug compiler optimizations; to augment benchmarks with verification code; and to visualize data structures.

Magalhães, José Wesley de Souza↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Beam-ion Studies in NSTX and NSTX-U (Final Technical Report)

The confinement of high energy "fast ions" is crucial for the success of magnetic fusion as a practical energy source. The research performed by UC Irvine on NSTX and NSTX-U provided new information about this important topic in the configuration known as a "spherical tokamak." Injected neutral beams provided the fast ions (also known as "beam ions"). There were five overarching goals of the research. One objective was to measure the confinement of beam ions in order to ascertain if they were accomplishing their desired purpose of transferring their energy to the bulk plasma. A second goal was to better understand instabilities that are driven unstable by the fast ions. A related goal was to use the similarities and differences between NSTX and the DIII-D conventional tokamak to better understand the fast-ion driven instabilities. A fourth goal was to develop new instruments to measure fast ions and techniques that facilitate analysis of the data. The fifth objective was to measure and understand acceleration of beam ions by RF waves. Much was accomplished in all of these five areas. In the first, it was shown that the large magnetic moment of the beam ions did not harm confinement but instabilities known as the "sawtooth" and "long-lived mode" do. In the second area, much attention was devoted to the fast-ion instabilities known as "Alfvén eigenmodes." In particular, Alfvén eigenmode "avalanches" can cause ~ 30% of the fast ions to be lost in a single explosive burst. The comparative studies with DIII-D showed that an instability discovered on NSTX is also important in conventional tokamaks. In the fourth category, several instruments were developed, a number of effects that complicate interpretation of the data were understood, and progress toward a new method to infer the fast-ion distribution function from the data was made. In the fifth category, the measured profile of accelerated fast ions was initially much broader than theoretical predictions but subsequent improvements in the theoretical modeling achieved good agreement with the data.

43 PARTICLE ACCELERATORS↗

Development of a cosmic ray oriented trigger for the fluorescence telescope on EUSO-SPB2

The Extreme Universe Space Observatory on a Super Pressure Balloon 2 (EUSO-SPB2), in preparation, aims to make the first observations of Ultra-High Energy Cosmic Rays (UHECRs) from near space using optical techniques. EUSO-SPB2 will prototype instrumentation for future satellite-based missions, including the Probe of Extreme Multi-Messenger Astrophysics (POEMMA) and K-EUSO. The payload will consist of two telescopes. The first is a Cherenkov telescope (CT) being developed to quantify the background for future below-the-limb very high energy (E 10 PeV) astrophysical neutrino observations, and the second is a fluorescence telescope (FT) being developed for detection of UHECRs. The FT will consist of a Schmidt telescope, and a 6192 pixel ultraviolet camera with an integration time of 1.05 s. The first step in the data acquisition process for the FT is a hardware level trigger in order to decide which data to record. In order to maximize the number of UHECR induced extensive air showers (EASs) which can be detected, a novel trigger algorithm has been developed based on the intricacies and limitations of the detector. Finally, the expected performance of the trigger has been characterized by simulations and, pending hardware verification, shows that EUSO-SPB2 is well positioned to attempt the first near-space observation of UHECRs via optical techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Ferrimagnetic spin waves in honeycomb and triangular layers of Mn{sub 3}Si{sub 2}Te{sub 6}.

A detailed analysis of the ferrimagnetic ground state of Mn 3 Si 2 Te 6 has been performed using inelastic neutron scattering. Although the proposed valence of the nominal Mn 2+ ions would have quenched orbital angular momentum, a significant exchange anisotropy exists in Mn 3 Si 2 Te 6 . This apparent exchange anisotropy is a manifestation of a weak spin-orbit coupling in the layered material. We employ a detailed simulation of the spin-wave spectrum coupling traditional refinement of dispersion parameters to image analysis techniques, while including Monte Carlo simulations of the instrumental resolution to accurately identify the exchange couplings to the third nearest neighbor. An independent validation of our results is made by comparing our final Hamiltonian to heat capacity measurements.

Sala, G.↗

First observations from the Kr multi-monochromatic x-ray imager for time and spatially resolved diagnosis of hot implosion cores

This paper presents initial findings from the recently deployed Kr multi-monochromatic x-ray imager (Kr MMI) at the Omega laser facility. The experiment focuses on exploring implosion dynamics in exploding pusher capsules at three distinct initial gas fill densities. Utilizing time-gated and spatially integrated measurements, core size, electron temperature (Te), and electron densities (ne) are extracted through the analysis of the spectral region encompassing the Kr He α and its satellite lines. A comprehensive spectral database, incorporating atomic kinetics, spectroscopic-quality radiation transport, and Stark broadened line shapes, has been developed for rigorous data analysis. These measurements underscore the utility of the new Kr MMI instrument, which, combined with sophisticated analysis techniques, enables the diagnosis of plasma conditions at Te>2000 eV, thereby extending the capabilities beyond the prior Ar MMI design. This is an important stepping stone for achieving time-gated and space-resolved diagnostics of electron temperature, electron density, and heat transport in high temperature implosion cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Advances in secondary ion mass spectrometry for N-doped niobium

Accurate secondary ion mass spectroscopy measurement of nitrogen in niobium relies on the use of closely equivalent standards, made by ion implantation, to convert nitrogen signal intensity to nitrogen content by determination of relative sensitivity factors (RSFs). Accurate RSF values for ppm-range nitrogen contents are increasingly critical, as more precision is sought in processes for next-generation superconducting radiofrequency (SRF) accelerator cavities. Furthermore, factors influencing RSF value measurements were investigated with the aim of reliably attaining better than 10% accuracy in nitrogen concentrations at various depths into the bulk. This has been accomplished for materials typical of SRF cavities at the cost of increased attention to all aspects.

47 OTHER INSTRUMENTATION↗