Search NASA⌕ Search

SEARCH · Search NASA

Results for “terminal metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hubble Space Telescope First Servicing Mission Prelaunch Mission Operation Report

The Hubble Space Telescope (HST) is a high-performance astronomical telescope system designed to operate in low-Earth orbit. It is approximately 43 feet long, with a diameter of 10 feet at the forward end and 14 feet at the aft end. Weight at launch was approximately 25,000 pounds. In principle, it is no different than the reflecting telescopes in ground-based astronomical observatories. Like ground-based telescopes, the HST was designed as a general-purpose instrument, capable of using a wide variety of scientific instruments at its focal plane. This multi-purpose characteristic allows the HST to be used as a national facility, capable of supporting the astronomical needs of an international user community. The telescope s planned useful operational lifetime is 15 years, during which it will make observations in the ultraviolet, visible, and infrared portions of the spectrum. The extended operational life of the HST is possible by using the capabilities of the Space Transportation System to periodically visit the HST on-orbit to replace failed or degraded components, install instruments with improved capabilities, re-boost the HST to higher altitudes compensating for gravitational effects, and to bring the HST back to Earth when the mission is terminated. The largest ground-based observatories, such as the 200-inch aperture Hale telescope at Palomar Mountain, California, can recognize detail in individual galaxies several billion light years away. However, like all earthbound devices, the Hale telescope is limited because of the blurring effect of the Earth s atmosphere. Further, the wavelength region observable from the Earth s surface is limited by the atmosphere to the visible part of the spectrum. The very important ultraviolet portion of the spectrum is lost. The HST uses a 2.4-meter reflective optics system designed to capture data over a wavelength region that reaches far into the ultraviolet and infrared portions of the spectrum.

Source record↗

ATD-2 TFDM Terminal Publication Service (TTP)

Learn the many benefits of the newest SWIM feed from the surface system. This will discuss current options to onboard with this feed, allow participants to ask questions and provide some examples of how the data can be used. Service Includes Flight Data Individual flight updates containing flight identifiers, targeted times, actual times, runway, parking gate, spot, departure fix (predicted, assigned, actual as appropriate), flight states, and more. Airport Information Airport configurations, airport and runway rates, ramp closures, runway closures, taxiway closures. Traffic Management Restrictions Call for Release programs departure MIT/MINIT restrictions, departure stop/ground stop programs. Along with list of impacted flights for each. Flight Delay Airport and runway delay by arrival, departure, and total. Operational Metrics Metrics on airport throughput and individual flight metrics. Surface Metering Program SMP start / end times, metering constraint type / details, updates to existing programs, TMAT compliance window, departure queue length, and more.

Gorman, Shawn M.↗

The color bar phase meter: A simple and economical method for calibrating crystal oscillators

Comparison of crystal oscillators to the rubidium stabilized color burst is made easy and inexpensive by use of the color bar phase meter. Required equipment consists of an unmodified color TV receiver, a color bar synthesizer and a stop watch (a wrist watch or clock with sweep second hand may be used with reduced precision). Measurement precision of 1 x 10 to the minus 10th power can be realized in measurement times of less than two minutes. If the color bar synthesizer were commercially available, user cost should be less than $200.00, exclusive of the TV receiver. Parts cost for the color bar synthesizer which translates the crystal oscillator frequency to 3.579MHz and modulates the received RF signal before it is fed to the receiver antenna terminals is about $25.00. A more sophisticated automated version, with precision of 1 x 10 to the minus 11th power would cost about twice as much.

Davis, D. D.↗

Radar Reflectivity in Wingtip-Generated Wake Vortices

This report documents new predictive models of radar reflectivity, with meter-scale resolution, for aircraft wakes in clear air and fog. The models result from a radar design program to locate and quantify wake vortices from commercial aircraft in support of the NASA Aircraft Vortex Spacing System (AVOSS). The radar reflectivity model for clear air assumes: 1) turbulent eddies in the wake produce small discontinuities in radar refractive index; and 2) these turbulent eddies are in the 'inertial subrange' of turbulence. From these assumptions, the maximum radar frequency for detecting a particular aircraft wake, as well as the refractive index structure constant and radar volume reflectivity in the wake can be obtained from the NASA Terminal Area Simulation System (TASS) output. For fog conditions, an empirical relationship is used to calculate radar reflectivity factor from TASS output of bulk liquid water. Currently, two models exist: 1) Atlas-based on observations of liquid water and radar reflectivity factor in clouds; and 2) de Wolf- specifically tailored to a specific measured dataset (1992 Vandenberg Air Force Base).

Marshall, Robert E.↗

Evidence for Asteroidal Origin of the Tunguska Object

The progress in the understanding of the Tunguska object is reviewed in the light of evidence presented in numerous recent investigations, which appeared following the publication of my 1983 paper on the object's proposed asteroidal nature. The issues addressed extensively in the present review involve: (i) the fundamental characteristics of the event, such as the object's energy, altitude and velocity at the time of its terminal explosion and the dynamic pressure involved; (ii) the problem of atmospheric fragmentation of very massive impactors and the implications for their ablation and deceleration; (iii) new analysis of the orientation of the Tunguska object's heliocentric orbit based on the best data on the apparent radiant of the fireball's atmospheric trajectory; and (iv) comparison with the findings of other recent investigations, including compositional studies. Also employed in the arguments are the results now available on the impacts of comet Shoemaker-Levy 9's fragments into Jupiter and the findings of a recent comparative study of two huge fireballs (one cometary, one stony, both involving impactors several meters across) observed with the cameras of the European Network of fireball monitoring. It is concluded that hypotheses based on presumed cometary origin of the Tunguska object encounter unsurmountable difficulties and that the interpretation of the event as a fall of a small stony or carbonaceous asteroid is not only plausible, but virtually certain.

Sekanina, Z.↗

Impact of Electrolyte Solvent on Li 4 Ti 5 O 12 /LiNi 0.90 Mn 0.05 Co 0.05 O 2 Battery Performance for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) systems require dedicated development of battery materials that target long cycle life and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) and LiNi 0.9 Mn 0.05 Co 0.05 O 2 (NMC90-5-5) shows promise to achieve targets for BTMS applications; however, minimal literature is available that discusses electrolyte solvent selection for this pairing. This study explores the role of electrolyte solvent on cycle life in LTO/NMC90-5-5 batteries. Four model electrolytes are evaluated; the baseline, Gen2, is compared with 1M LiPF 6 added to each of three separate solvents: ethylene carbonate (EC), ethyl methyl carbonate (EMC), and fluoroethylene carbonate (FEC). An additional consideration is that NMC90-5-5 undergoes an H2→H3 phase transition that allows for a significant increase to capacity; however, it’s unclear how this phase transition impacts electrolyte stability and cycle life. Therefore, the phase transition is avoided or accessed by cycling to 2.6V or 2.7V, respectively. The cells with Gen2, cycled to 2.6V, show the highest capacity retention due to EC passivating the LTO, EMC improving stability at the NMC90-5-5, and avoiding increased degradation from the 2.7V protocol. Despite having high initial reactivity that causes Li-depletion, FEC was the only solvent to avoid increased degradation when moving to the higher termination voltage.

25 ENERGY STORAGE↗

Simulator Investigation of Controls and Display Required for Terminal Phase of Coplanar Orbital Rendezvous

A simulator study was made of presentations and control requirements for a manned astrovehicle employed in the interception of artificial satellites during the terminal phase of an orbital rendezvous of the satellite. The study was considered in terms of a manned interceptor having a home berth at a manned space station which is in circular orbit 500 miles above the earth. Interceptions were restricted to coplanar conditions and ranges of one-half mile. The results are believed to be generally applicable to conditions wherein the target is in the terminal area. Presentations which do not provide for attitude indications of the intercepting vehicle are not satisfactory. A direct-visual-observation presentation employing a screen, a projected star background, and a projected image of the target provided a feeling of "realism" in tracking and would be a satisfactory pilot-training aid. Use of longitudinal-translation and attitude controls alone is inadequate. Use of translation control alone, parallel and normal to the axis of the intercepting vehicle, is effective; the addition of attitude control enhanced the effectiveness, provided the control was used discriminately. Direct-visual-observation interceptions can be performed effectively without the aid of range and rate-of-closure-of-range meters at speeds up to approximately 50 feet per second; however, higher speeds of interception require the use of these instruments.

Wolowicz, Chester H.↗

Improved Gas Filling and Sealing of an HC-PCF

An improved packaging approach has been devised for filling a hollow-core photonic-crystal fiber (HC-PCF) with a gas, sealing the HC-PCF to retain the gas, and providing for optical connections and, optionally, a plumbing fitting for changing or augmenting the gas filling. Gas-filled HC-PCFs can be many meters long and have been found to be attractive as relatively compact, lightweight, rugged alternatives to conventional gas-filled glass cells for use as molecular-resonance frequency references for stabilization of lasers in some optical-metrology, lidar, optical-communication, and other advanced applications. Prior approaches to gas filling and sealing of HC-PCFs have involved, variously, omission of any attempt to connectorize the PCF, connectorization inside a vacuum chamber (an awkward and expensive process), or temporary exposure of one end of an HC-PCF to the atmosphere, potentially resulting in contamination of the gas filling. Prior approaches have also involved, variously, fusion splicing of HC-PCFs with other optical fibers or other termination techniques that give rise to Fresnel reflections of about 4 percent, which results in output intensity noise.

Poberezhskiy, Ilya↗

Design of a 2.5 Gbps Optical Transmitter for the International Space Station

A high data rate laser transmitter assembly (LTA) has been designed as the source for an optical free-space communication link between the International Space Station and the 1-meter Optical Communication Telescope Laboratory (OCTL) to be built at the Table Mountain Facility (IMF, Wrightwood, CA). The transmitter design concept uses a fiber-based master oscillator power amplifier (MOPA) configuration with an average output power of 200 made at a 1550 nm transmit wavelength. This transmitter source is also designed to provide a signal at 980 nm to the Silicon-based focal plane array for the point-ahead beam control function. This novel integration of a 980 nm boresight signal allows the use of Silicon based imagers for the acquisition/tracking and point-ahead functions, yet permits the transmit signal to be at any wavelength outside the Silicon sensitivity. The LTA, a sub-system of the Flight Terminal, has been designed to have a selectable data rate from 155 - 2500 Mbps in discrete steps. It also incorporates a 2.5 Gbps pseudo-random bit sequence (PRBS) generator for complete link testing and diagnostics. The design emphasizes using commercial off the shelf components (COTS).

Ortiz, Gerardo G.↗

Strategies for Choosing Descent Flight-Path Angles for Small Jets

Three candidate strategies for choosing the descent flight path angle (FPA) for small jets are proposed, analyzed, and compared for fuel efficiency under arrival metering conditions. The strategies vary in operational complexity from a universally fixed FPA, or FPA function that varies with descent speed for improved fuel efficiency, to the minimum-fuel FPA computed for each flight based on winds, route, and speed profile. Methodologies for selecting the parameter for the first two strategies are described. The differences in fuel burn are analyzed over a year s worth of arrival traffic and atmospheric conditions recorded for the Dallas/Fort Worth (DFW) Airport during 2011. The results show that the universally fixed FPA strategy (same FPA for all flights, all year) burns on average 26 lbs more fuel per flight as compared to the minimum-fuel solution. This FPA is adapted to the arrival gate (direction of entry to the terminal) and various timespans (season, month and day) to improve fuel efficiency. Compared to a typical FPA of approximately 3 degrees the adapted FPAs vary significantly, up to 1.3 from one arrival gate to another or up to 1.4 from one day to another. Adapting the universally fixed FPA strategy to the arrival gate or to each day reduces the extra fuel burn relative to the minimum-fuel solution by 27% and 34%, respectively. The adaptations to gate and time combined shows up to 57% reduction of the extra fuel burn. The second strategy, an FPA function, contributes a 17% reduction in the 26 lbs of extra fuel burn over the universally fixed FPA strategy. Compared to the corresponding adaptations of the universally fixed FPA, adaptations of the FPA function reduce the extra fuel burn anywhere from 15-23% depending on the extent of adaptation. The combined effect of the FPA function strategy with both directional and temporal adaptation recovers 67% of the extra fuel relative to the minimum-fuel solution.

Wu, Minghong Gilbert↗

Trajectory Prediction Accuracy and Error Sources for Regional Jet Descents: Results of a 2010 Flight Trial at Denver International Airport using a Global 5000 Test Aircraft - Part I

The Efficient Descent Advisor (EDA) controller automation tool generates trajectory-based speed, path, and altitude-profile advisories to facilitate efficient, continuous descents into congested terminal airspace. While prior field trials have assessed the trajectory-prediction accuracy for large jet (i.e., Boeing and Airbus) types, smaller (i.e., regional and business) jet types present unique challenges involving different descent procedures and Flight Management System (FMS) capabilities. A small-jet field trial was conducted at Denver in the fall of 2010 with the objective of measuring trajectory prediction accuracy and quantifying the primary sources of error. This paper uses data collected onboard a Bombardier Global 5000 test aircraft to quantify the size and sources of trajectory prediction error. Error sources were quantified for the 44 runs by incrementally replacing predicted data with data collected onboard the aircraft and measuring the effect on time error. Results for en-route descents, from prior to top of descent to the meter fix 60-120 nmi downstream, indicate that the aircraft arrived an average 15 seconds earlier than predicted, with a standard deviation of 10 seconds. Target Mach and CAS deceleration were found to be the two largest error sources. If CAS deceleration error was reduced using a typical, more predictable level flight deceleration then the arrival time prediction error in 2010 would be on par with a 2009 flight trial of Airbus and Boeing revenue flights. Four of the error sources, tracker jumps, CAS deceleration, target Mach, and path distance, lend themselves to significant reductions with modest to no changes to ATC automation andor procedures. Wind error and its impact on arrival time error was significantly reduced in 2010 compared to a 1994 flight test using NASAs Boeing 737 test aircraft.

Trajectory Prediction Error↗

Hybrid Glacier Inventory, Gravimetry and Altimetry (HIGA) Mass Balance Product for Greenland and the Canadian Arctic

We present a novel inversion algorithm that generates a mass balance field that is simultaneously consistent with independent observations of glacier inventory derived from optical imagery, cryosphere-attributed mass trends derived from satellite gravimetry, and ice surface elevation trends derived from airborne and satellite altimetry. We use this algorithm to assess mass balance across Greenland and the Canadian Arctic over the Sep-2003 to Oct- 2009 period at 26 kilometers resolution. We evaluate local algorithm-inferred mass balance against forty in situ point observations. This evaluation yields a root mean squared error (RMSE) of 0.15 mWE/a ( 0.15 meters (water equivalent) per annum), and highlights a paucity of in situ observations from regions of high dynamic mass loss and peripheral glaciers. We assess mass losses of 212 plus or minus 67 Gigatons per annum to the Greenland ice sheet proper, 38 Gigatons per annum to peripheral glaciers in Greenland, and 42 Gigatons per annum to glaciers in the Canadian Arctic. These magnitudes of mass loss are dependent on the gravimetry-derived spherical harmonic mass trend we invert. We spatially partition the transient glacier continuity equation by differencing algorithm inferred mass balance from modeled surface mass balance, in order to solve the horizontal divergence of ice flux as a residual. This residual ice dynamic field infers flux divergence (or submergent flow) in the ice sheet accumulation area and at tidewater margins, and flux convergence (or emergent flow) in land-terminating ablation areas, which is consistent with continuum mechanics theory.

Altimetry↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

A flight evaluation of VTOL jet transport under visual and simulated instrument conditions

A flight investigation was performed with the Dornier DO-31 VTOL to evaluate the performance, handling qualities, and operating characteristics that are considered to be important in the operation of a commerical VTOL transport in the terminal area. The DO-31, a 20,000 kilogram transport, has a mixed jet propulsion system; main engines with nozzles deflect from a cruise to a hover position, and vertical lift engines operated below 170 knots. This VTOL mode incorporates pitch and roll attitude and yaw rate stabilization. The tests concentrated on the transition, approach, and vertical landing. The mixed jet propulsion system provided a large usable performance envelope that enabled simulated IFR approaches to be made on 7 deg and 12 deg glide slopes. In these approaches management of thrust magnitude and direction was a primary problem, and some form of integrating the controls will be necessary. The handling qualities evaluation pointed out the need for additional research of define flight path criteria. The aircraft had satisfactory control and stability in hover out of ground effect. The recirculation effects in vertical landing were large below 15 meters.

Holzhauser, C. A.↗

Great Salt Lake Health and Air Quality: Monitoring Lakebed Exposure and its Impact on Air Quality and Environmental Hazards in the Great Salt Lake Watershed

Water flow into the Great Salt Lake has declined rapidly over the last forty years due to human withdrawals and climate change. As a result of declining lake levels, over 50% of the lakebed is now exposed. Dust storms may grow in frequency and intensity across Northern Utah as lakebed dust becomes airborne under specific meteorological conditions. In our research project, we utilized satellite imagery from Terra and Aqua, Sentinel-5P, CALIPSO, Landsat 5 TM, Landsat 7 ETM+, Landsat 8 OLI-2, Suomi NPP, ground sensor environmental data, and demographic data to understand the relationship between lake desiccation and dust, and the impact of pollution upon the communities surrounding the Great Salt Lake. By plotting changes in Lake Surface Area against Aerosol Optical Depth (AOD) over our study period (2010-2022), we found an inverse relationship (R2=0.3423) between lake surface area and dust levels within our study area. We conducted a Vertical Feature Mask (VFM) and Extinction Coefficient Plot, from which we identified that during dust events, the aerosol type is mainly polluted dust and the aerosol height is 200 meters from the surface. Lastly, we created bivariate choropleth maps, which demonstrate which census tracts within our study area are most vulnerable to AOD (a proxy for PM2.5 from dust), NO2 and HCHO (precursors to ozone). In summary, our findings revealed that declining lake levels are associated with an increase in intensity of dust events, and these dust events will particularly impact residents of Tooele County and the west side of Salt Lake City. Project resources support partner needs by informing targeted air monitoring efforts, lakebed management practices, and advocacy efforts for GSL stewardship.

Terminal Saline Lake↗

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

Trajectory Prediction Accuracy and Error Sources for Regional Jet Descents: Results of a 2010 Flight Trial at Denver International Airport using SkyWest Revenue Flights - Part II

The Efficient Descent Advisor (EDA) controller automation tool generates trajectory-based speed, path, and altitude-profile advisories to facilitate efficient, continuous descents into congested terminal airspace. While prior field trials have assessed the trajectory prediction accuracy for large jet (i.e., Boeing and Airbus) types, smaller (i.e., regional and business) jet types present unique challenges involving different descent procedures and Flight Management System (FMS) capabilities. This paper quantifies the trajectory prediction accuracy for small jet revenue flight descents based on SkyWest Canadair Regional Jet 200, 700, and 900 aircraft arrivals to Denver in the fall of 2010. Post flight test data analysis and SkyWest pilot interviews uncovered unexpected variation between flight crews due to different interpretations of (1) which fixed flight path angle (FPA) to fly based on the flight trial procedure and (2) how to fly the descent to achieve the target FPA. Pilot reports were used to select a subset of flights where pilots indicated an FPA according to the flight trial procedure to remove the unexpected variation due to (1) to focus on (2). Results for the subset for en-route descents, from prior to top of descent to the meter fix 30 to 130 nmi downstream, indicate that aircraft arrived to the meter fix six seconds early with about a twelve second standard deviation. Large FPA errors up to one degree relative to the EDA flight trial procedure were detected after the flight trial as a characteristic of the unexpected variation. It is recommended that quantitative validation be performed during future flight trials so that experimental procedures can be adjusted if unexpected results are detected.

Field Test Results↗

Indigenous and Contaminant Microbes in Ultradeep Mines

Rock, air and service water samples were collected for microbial analyses from 3.2 kilometers depth in a working Au mine in the Witwatersrand basin, South Africa. The approx. 1 meter wide mined zone was comprised of a carbonaceous, quartz, sulfide, uraninite and Au bearing layer, called the Carbon Leader, sandwiched by quartzite and conglomerates. The microbial community in the service water was dominated by mesophilic aerobic and anaerobic, alpha, beta, and gamma-Proteobacteria with a total biomass concentration approx. 10(exp 4) cells/ml, whereas, that of the mine air was dominated by members of the Chlorobi and Bacteroidetes groups and a fungal component. The microorganisms in the Carbon Leader were predominantly mesophilic, aerobic heterotrophic, nitrate reducing and methylotrophic, beta and gamma-Proteobacteria that were more closely related to service water microorganisms rather than air microbes. Rhodamine WT dye and fluorescent microspheres employed as contaminant tracers, however, indicated that service water contamination of most of the rock samples was < 0.01% during acquisition. The microbial contaminants most likely originated from the service water, infiltrated the low permeability rock through and accumulated within mining-induced fractures where they survived for several days prior to being mined. Combined PLFA and terminal restriction fragment length profile (T-RFLP) analyses suggest that the maximum concentration of indigenous microorganisms in the Carbon Leader was < 10(exp 2) cells/g. PLFA, (35)S autoradiography and enrichments suggest that the adjacent quartzite was less contaminated and contained approx. 10(exp 3) cells/gram of a thermophilic, sulfate reducing bacteria, SRB, some of whom are delta Proteobacteria. Pore water and rock geochemical analyses suggest that these SRB's may have been sustained by sulfate diffusing from the adjacent U-rich, Carbon Leader where it was formed by radiolysis of sulfide.

Onstott, T. C.↗