Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal model exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Experimental inference of neutral and impurity transport in Alcator C-Mod using high-resolution x-ray and ultra-violet spectra

We present experimental inferences of cross-field impurity transport coefficients for AlcatorC-Mod plasmas without edge-localized modes, leveraging a novel forward model for the entire Ca Kα spectrum, including satellite lines within the spectral range, to compare to high-resolution x-ray imaging crystal spectroscopy (XICS). These measurements are complemented by extreme ultra-violet (EUV) spectroscopy that constrains transport closer to the edge. Using new atomic data sets for both XICS and EUV analysis has enabled consideration of line ratios across both spectral ranges and has increased the accuracy of inferred transport coefficients. Inclusion of charge exchange between edge thermal neutrals and impurities is shown to be extremely important in C-Mod pedestals. Atomic D neutral densities from experimental D Lyα measurements at the midplane are compared to SOLPS-ITER simulations, finding good agreement. Bayesian inferences of impurity transport coefficients are presented for L-, EDA H-, and I-mode discharges, making use of the Aurora package for forward modeling and combining our spectroscopic constraints. Experimentally inferred diffusion profiles are found to match turbulent transport models at midradius within uncertainties, using both quasilinear gyro-fluid TGLF SAT-1 and nonlinear ion-scale gyrokinetic CGYRO simulations. Furthermore, significant discrepancies in convection are observed in some cases, suggesting difficulties in predictions of flat or hollow impurity profiles.

neutrals↗

The impact of non-ideal phase change properties on phase change thermal energy storage device performance

Phase change materials have been known to improve the performance of energy storage devices by shifting or reducing thermal/electrical loads. While an ideal phase change material is one that undergoes a sharp, reversible phase transition, real phase change materials do not exhibit this behavior and often have one or more non-idealities – glide, hysteresis, supercooling – associated with them. Experimental and modeling techniques to characterize these non-ideal properties are reasonably well understood, however, their impact on the performance of a thermal energy storage system is not fully understood. Herein, we analyze the performance of a heat exchanger with a phase change material as a function of the different non-idealities, for a heating and a cooling application. We focus on the impact of these non-ideal behaviors on different modes of operation of the thermal energy storage device, which will serve as a useful guide to researchers on the relative importance of the non-ideal properties, along with the necessary accuracy required during an experimental characterization.

25 ENERGY STORAGE↗

Design of an Additively Manufactured Recuperator With 800 °C Inlet Temperature for sCO2 Power Cycle Application

Abstract Recuperators with design temperatures at and above 800 °C can further increase the thermal efficiency of supercritical CO2 power cycles by enabling higher turbine exhaust temperatures. Mar-M247 is a well-suited nickel-based superalloy for high temperature service due to its high creep strength that prevents excessive material thickness being required for pressure containment. Additive manufacturing using a high-speed laser-directed energy deposition (L-DED) process presents a promising solution, with build trials demonstrating the ability to produce nonconventional flow channels for enhanced heat transfer. A design process is presented that includes aerothermal and mechanical evaluation to maximize performance within the constraints of the manufacturing process. A 2-D heat transfer network and pressure drop code allows prediction of flow distribution and its effect on overall thermal performance. Established literature correlations, along with CFD simulation, inform the prediction of heat transfer coefficients and friction factors for the flowpaths and enhancement features in the heat exchanger core. Mechanical evaluation using finite element analysis (FEA) modeling with the intent of the ASME Boiler & Pressure Vessel Code (BPVC) Section VIII, Div. 2 assesses the operational safety of the design. The detailed design features annular finned passages that take advantage of helical flow paths to distribute the flow from separated headers to shared heat transfer surfaces. Performance predictions for the recuperator at a 50 kW scale provide insights into the feasibility of the additively manufactured (AM) process to produce recuperators on a commercial scale that extend existing operating envelopes.

Engineering↗

Predictive model using artificial neural network to design phase change material-based ocean thermal energy harvesting systems for powering uncrewed underwater vehicles

Uncrewed Underwater Vehicles (UUVs) are a major beneficiary of the phase change material (PCM)-based ocean thermal energy harvesting technology for their mission needs. However, this technology relies on different parameters and energy conversion steps that could be critical to the general energy generation efficiency. Sea trials showed that the design performed lower than their laboratory design specifications. This underperformance results from different factors, mainly the UUV’s trajectory, travel time, underwater ocean currents, temperature fluctuations, and biofouling on the heat exchanger due to long term underwater operations. Therefore, there exists a need to continuously monitor the ambient energy harvesting system and predict system performance, for mission planning purposes. Two major parameters influencing the energy harvesting system include the final pressure inside the hydraulic energy storage vessel or accumulator, and the electrical load value. Here, this work focuses on the hydraulic to electric energy conversion system. Therefore, a combination of numerical model and experimental testing is used to develop a predictive model using artificial neural network using MATLAB. After validation with experimental testing, 1000 data samples obtained from the numerical model are used to train the ANN. Compared to the experimental results, the developed ANN model can predict in less than a second the designed benchtop system’s total efficiency with less than 15 percent maximum error range. This predictive model development represents a cost-effective way for optimization and a computational energy efficient mode aboard UUVs for mission planning for deployed UUVs using PCM-based ocean thermal energy harvesting technology.

30 DIRECT ENERGY CONVERSION↗

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by film-wise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be ap-plied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine prod-uct (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a rep-resentative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Lastly, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a re-plenishable coating system.

20 FOSSIL-FUELED POWER PLANTS↗

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

CRADA Number NFE-18-07325 with TCPoly, Inc. (CRADA Final Report)

TCPoly is commercializing high performance composite materials for the 3D printing industry and the company focus is manufacturing high thermal conductivity plastics for 3D printing of heat exchangers, electronic cooling devices, and mold tooling. Through the Innovation Crossroads Program, I was able to collaborate with ORNL researchers to expand the company’s technology offering and revamp the company’s business model and focus.

36 MATERIALS SCIENCE↗

Revealing the Crystalline Architecture of Semicrystalline Ion Exchange Membranes for the Design of Conductive and Durable Alkaline Anion Exchange Membranes

Alkaline anion exchange membrane (AAEM) fuel cells offer a cost-effective alternative to proton exchange membrane (PEM) fuel cells by eliminating the need for expensive precious metal catalysts. In both PEMs and AAEMs, semicrystalline polymers are a common choice, as the crystalline domains can act as mechanical reinforcements that limit swelling and promote mechanical durability in the material. However, spatially resolved characterization of crystalline organization in ion exchange membranes beyond ensemble-averaged X-ray scattering is underrepresented, likely in part due to ionization damage limitations in soft materials. Here, in this study, we resolve the nanometer-size crystallites in semicrystalline ion exchange membranes by applying cryogenic four-dimensional scanning transmission electron microscopy (cryo-4D-STEM) along with data-processing algorithms designed to optimize signals at a low dose to minimize radiation damage. We investigate the effects of synthesis components, including molecular weight and thermal treatment, on a model system of AAEMs in comparison to Nafion, the most commonly used and commercially successful PEM today. We find that excess water uptake in polymer membranes, a property directly associated with weak mechanical durability and with possible negative impacts on ion conductivity, can be reduced by over 30% by varying the polymer's crystalline morphology through changes in synthesis parameters such as molecular weight and thermal history. Our results indicate that this improvement is correlated with smaller crystalline domains with a more homogeneous distribution. More broadly, these results demonstrate how the crystalline architecture of polymer membranes can be tuned through their chemistry and thermal treatment in order to improve their conductivity and durability for commercial fuel cell performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetothermal properties of Tm x Dy 1- x Al 2 ( x = 0.25, 0.50 and 0.75)

Here, we describe magnetic, thermal, and magnetocaloric properties of rare earth intermetallic compounds Tm x Dy 1-x Al 2 with 0.25, 0.5 and 0.75. Using model Hamiltonian we consider contributions of the crystalline electric field anisotropy in both Tm and Dy magnetic sublattices, disorder in exchange interactions among Tm-Tm, Dy-Dy and Tm-Dy magnetic ions, and the Zeeman effect. Employing earlier reported and new experimental measurements, we first determine a single free variable – the intersublattice magnetic exchange parameter – to properly model the temperature and magnetic field dependencies of heat capacity and magnetization, and then use the modeling results to explain the emergence of an anomalous spin reorientation transition and its influence on the magnetocaloric effect in the title compounds. Theoretical results agree with experimental data reasonably well.

36 MATERIALS SCIENCE↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal characterization of the build chamber in electron beam melting

Electron beam powder bed fusion, commonly termed electron beam melting (EBM), offers great versatility in multiple-part processes and can produce high quality as-built components due to low residual stresses. The EBM process is complex and requires careful thermal management, including uniform and consistent preheating of the powder bed, in order to ensure quality and consistency of the product. However, most of the simulations in the literature focus on the selective melting stage of the process. As of today, optimal conditions for initial pre-heating temperatures are only available for specific materials. Thus, in order to extend the EBM technology to other desired build materials, a much better understanding of the pre-heating stages is required. In this work, numerical and experimental approaches are combined in order to investigate the effects and sensitivities of heat removal from the build plate during EBM pre-heating stages. For this purpose, a carefully reconstructed numerical model of the build chamber of an ARCAM Q20 + machine is developed. It includes all main parts of the chamber and all relevant heat transfer mechanisms, whereas special attention is paid to radiation heat exchange between various bodies. In order to validate the model, dedicated experiments are performed, in which a system of thermocouples is installed in the build chamber, allowing direct measurement of the local temperatures of the start-plate and heat shields. A good agreement between the simulation and experimental findings is achieved, leading to a better understanding of the thermal processes characteristic to the pre-heating stages. This basic analysis is followed by a representative pre-heating case, where a powder bed is also considered. The energy required to obtain the desired pre-heating temperatures is evaluated, and the role of the powder bed in heat transfer within the chamber is assessed. The pre-heating stage, simulated in the present work, is supposed to create proper conditions for sintering and consequent melting of the powder, which are highly dependent on the local temperatures and heat transfer features. Thus, the findings of the reported work present a step towards a better understanding of the thermal processes that characterize EBM. The reported model can be further used to provide realistic boundary condition inputs for other meso- or macro-scale models as a function of time and geometry. The model can serve also for verification of machine settings, i.e., jump-safe and melt-safe ones which actually provide desired preheat, and for development of settings for new powders.

36 MATERIALS SCIENCE↗

Monte Carlo simulation to study the effect of molecular spin state on the spatio-temporal evolution of equilibrium magnetic properties of magnetic tunnel junction based molecular spintronics devices

With a variable spin state, paramagnetic molecules can affect the impact of magnetic exchange coupling strength between two ferromagnetic electrodes. Our magnetic tunnel junction based molecular spintronics devices (MTJMSD) were successful in connecting paramagnetic single molecular magnet (SMM) between two ferromagnetic electrodes. Isolated SMM exhibited a wide range of spin states. However, it was extremely challenging to identify the SMM spin state when connected to the ferromagnetic electrodes. Our prior experimental and Monte Carlo Simulations (MCS) studies showed that paramagnetic molecules produced unprecedented strong antiferromagnetic coupling between two ferromagnets at room temperature. The overall antiferromagnetic coupling occurred when a paramagnetic SMM made antiferromagnetic coupling to the first electrode and ferromagnetic coupling to the second ferromagnetic electrode. This paper studies the impact of variable molecular spin states of the SMMs, producing strong antiferromagnetic coupling between the ferromagnetic electrodes of MTJMSD. The MTJMSD used in this study was represented by an 11 x 50 x 50 Ising model, with 11 being the thickness of the MTJMSD and 5 x 10 x 50 being each electrode’s size. We employed a continuous MCS algorithm to investigate SMM’s spin state’s impact as a function of molecular exchange coupling strength and thermal energy.

36 MATERIALS SCIENCE↗