Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Anomalous reduction of the switching voltage of Bi-doped Ge{sub 0.5}Se{sub 0.5} ovonic threshold switching devices

Switching devices based on Ovonic Threshold Switching (OTS) have been considered as a solution to overcoming limitations of Si-based electronic devices, but the reduction of switching voltage is a major challenge. Here, we investigated the effect of Bi-doping in Ge{sub 0.5}Se{sub 0.5} thin films on their thermal, optical, electrical properties, as well as on the characteristics of OTS devices. As Bi increased, it was found that both of the optical energy gap (E{sub g}{sup opt}) and the depth of trap states decreased resulting in a drastic reduction of the threshold voltage (V{sub th}) by over 50%. In addition, E{sub g}{sup opt} was found to be about three times of the conduction activation energy for each composition. These results are explained in terms of the Mott delocalization effect by doping Bi.

36 MATERIALS SCIENCE↗

Volume-based glucose metabolic analysis of FDG PET/CT: The optimum threshold and conditions to suppress physiological myocardial uptake

Objective: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. Methods: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). Results: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7 ± 73.2 vs. 18.0 ± 53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. Conclusion: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, SeyedMohammad↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, Seyed Mohammad↗

Operability thresholds for thermally damaged EBW detonators

Operability thresholds that differentiate between functional RP-87 exploding bridge wire (EBW) detonators and nonfunctional RP-87 EBW detonators (duds) were determined by measuring the time delay between initiation and early wall movement (function time). The detonators were inserted into an externally heated hollow cylinder of aluminum and fired with current flow from a charged capacitor using an exploding bridge wire (EBW initiated). Functioning detonators responded like unheated pristine detonators when the function time was 4 μs or less. The operability thresholds of the detonators were characterized with a simple decomposition cookoff model calibrated using a modified version of the Sandia Instrumented Thermal Ignition (SITI) experiment. These thresholds are based on the calculated state of the PETN when the detonators fire. The operability threshold is proportional to the positive temperature difference (ΔT) between the maximum temperature within the PETN and the onset of decomposition (~406 K). Furthermore, the temperature difference alone was not sufficient to define the operability threshold. The operability threshold was also proportional to the time that the PETN had been at elevated temperatures. That is, failure was proportional to both temperature and reaction rate. The reacted gas fraction is used in the current work for the reaction correlation. Melting of PETN also had a significant effect on the operability threshold. Detonator failure occurred when the maximum temperature exceeded the nominal melting point of PETN (414 K) for 45±5 s or more.

42 ENGINEERING↗

Thickness threshold study of polyaniline-based lightning strike protection coating for carbon/glass fiber reinforced polymer composites

Different polyaniline (PANI) based lightning strike protection (LSP) coating thicknesses were tested against simulated lightning strike tests to evaluate the threshold thickness of the coating. A series of lightning strike tests were performed on carbon/glass fiber reinforced polymer (CFRP/GFRP) composites subjected to simulated lightning currents ranging from 40 to 100 kA. Five LSP-coated specimens were considered herein: two CFRP and three GFRP composites. A minimum of ~ 345 μm thick PANI-based LSP coating on CFRP and GFRP composites under a 40 kA peak current retained 83 % and 100 % residual strength, respectively. Additionally, GFRP specimens tested against 60 and 100 kA peak currents exhibited 100 % residual strength. Finally, this study proposes that a PANI-based LSP coating is suitable for protecting GFRP composites, while the careful design is necessary for CFRP composites to avoid any catastrophic failure.

36 MATERIALS SCIENCE↗

Inferring safety critical events from vehicle kinematics in naturalistic driving environment: Application of deep learning Algorithms

Advances in sensing technology has enabled the collection of countless terabytes of second-by-second kinematics data. Such data provides opportunities for real-time monitoring of driving behavior and identification of safety critical events (SCEs) including crashes and near crashes. The concept of volatility is relevant in this context, which identifies instability and erratic variations in driving behavior prior to involvement in SCEs. This study utilized vehicle kinematics from a large-scale naturalistic driving data to develop a deep learning approach based on 1D convolutional neural networks (CNN) for inferring SCEs. The data are unique in the sense that such accurate pre-crash data at high fidelity are not available in traditional crash repositories. This study contributes to the literature by providing a first attempt at predicting responses to SCEs by developing deep learning-based CNN architectures using novel driving volatility based kinematic thresholds for a sample of 9553 events. The key contribution lies in developing a volatility-based CNN input layout that is acceptable to CNN schemes and represents the motion kinematics such as speed, acceleration and volatility measures. Several 1D-CNN architectures were developed using layers, numbers of convolutions, layer patterns, and kernels. Shallow and deep architectures were tested, revealing higher accuracy of shallow architectures in detecting SCEs. The optimal number of epochs were identified using an early stopping method while the CNN performance was improved by increasing the number of epochs. The ensemble CNN had the highest predictive accuracy of 95.6% for detection of crashes and near crashes, which was 2.5% higher than the optimal CNN using 20% hold out test data. The ensemble CNN also outperformed classical machine learning models and model performance reported in past studies on detection of SCEs. Finally, these results have implications for identification of safety hotspots and providing real-time alerts and warnings in connected and highly automated vehicle environment including society of automotive engineers levels 3–5.

42 ENGINEERING↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

On/Off State Classification of a Reactor Facility Using Gas Effluence Measurements

Inferring on/off operational state of a reactor facility using measurements from an independent monitoring system is critical to the assessment of its compliance to agreements. In this paper, we consider the problem of inferring on/off state of a reactor facility using measurements of Ar-41, Cs-138, and Xe-138 gas effluence types collected at the facility’s off-gas stack. We present classifiers based on thresholding measurements of individual effluence types, and then present fusers that combine their outputs or measurements. We present five fusers based on simple majority rule, Chow’s pattern recognition function, Fisher’s combined p-value statistic, physics-based Poisson radiation counts model, and correlation coefficient method. In addition, we also test five machine learning methods based on non-linear classifiers, which are available as R packages. Finally, our results show that: (i) these gas effluence measurements are effective in inferring on/off state of a reactor facility; for example, best fusers achieve ~97% detection at ~1% false alarm rate, and (ii) fusers that combine all effluence types based on physics-based models, correlation coefficient and Fisher’s method outperform simple majority rule, Chow’s fusers and machine learning methods, as well as when they are applied to individual and pairs of effluence types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Step-Down Test Procedure for Wavelet Shrinkage Using Bootstrapping

Wavelet thresholding (or shrinkage) attempts to remove the noises existing in the signals while preserving inherent pattern characteristics in the reconstruction of true signals. For data-denoising purpose, we present a new wavelet thresholding procedure which employs the step-down testing idea of identifying active contrasts in unreplicated fractional factorial experiments. The proposed method employs bootstrapping methods to a step-down test for thresholding wavelet coefficients. By introducing the concept of a false discovery error rate in testing wavelet coefficients, we shrink the wavelet coefficients with p -values higher than the error rate. The error rate controls the expected proportion of wrongly accepted coefficients among chosen wavelet coefficients. Bootstrap samples are used to approximate the p -value for computational efficiency. We also present some guidelines for selecting the values of hyper-parameters which affect the performance in the step-down thresholding procedure. Based on some common testing signals and an air-conditioner sounds example, the comparison of our proposed procedure with other thresholding methods in the literature is performed. The analytical results show that the proposed procedure has a potential in data-denoising and data-reduction in a variety of signal reconstruction applications.

42 ENGINEERING↗

TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence. The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Semi-automatic Methods for Airway and Adjacent Vessel Measurement in Bronchiectasis Patterns in Lung HRCT Images of Cystic Fibrosis Patients

Airway and vessel characterization of bronchiectasis patterns in lung high-resolution computed tomography (HRCT) images of cystic fibrosis (CF) patients is very important to compute the score of disease severity. We propose a hybrid and evolutionary optimized threshold and model-based method for characterization of airway and vessel in lung HRCT images of CF patients. First, the initial model of airway and vessel is obtained using the enhanced threshold-based method. Then, the model is fitted to the actual image by optimizing its parameters using particle swarm optimization (PSO) evolutionary algorithm. The experimental results demonstrated the outperformance of the proposed method over its counterpart in R-squared, mean and variance of error, and run time. Moreover, the proposed method outperformed its counterpart for airway inner diameter/vessel diameter (AID/VD) and airway wall thickness/vessel diameter (AWT/VD) biomarkers in R-squared and slope of regression analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic peak interval, relative volatility, and relative amplitude detection in high-volume temporal data

Various technologies pertaining to automatic relative volatility and relative amplitude detection are described herein. A spectral density of a geospatial temporal dataset is computed, and one or more frequencies of the dataset are identified. A volatility period of interest is calculated based upon the frequencies, and volatility thresholds are computed based upon the volatility period of interest. One or more periods of potential interest are detected in the dataset based upon the geospatial temporal data and the volatility thresholds. An indication of the periods of interest, an occurrence of an event captured in the dataset, or a prediction of an occurrence of an event that is of potential interest to an analyst is output.

58 GEOSCIENCES↗

Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗