Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Laser Time-of-Flight Mass Spectrometry for Future In Situ Planetary Missions

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) is a versatile, low-complexity instrument class that holds significant promise for future landed in situ planetary missions that emphasize compositional analysis of surface materials. Here we describe a 5kg-class instrument that is capable of detecting and analyzing a variety of analytes directly from rock or ice samples. Through laboratory studies of a suite of representative samples, we show that detection and analysis of key mineral composition, small organics, and particularly, higher molecular weight organics are well suited to this instrument design. A mass range exceeding 100,000 Da has recently been demonstrated. We describe recent efforts in instrument prototype development and future directions that will enhance our analytical capabilities targeting organic mixtures on primitive and icy bodies. We present results on a series of standards, simulated mixtures, and meteoritic samples.

Getty, S. A.↗

The time-of-flight system on the Goddard medium energy gamma-ray telescope

A scintillation counter time of flight system, incorporated into the Goddard 50 cm by 50 cm spark chamber gamma ray telescope is described. The system, which utilizes constant fractions timing and particle position compensation and digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns is analyzed. The performance of this system during balloon flight is discussed.

Ross, R. W.↗

Constraining time-dependent ion temperature measurements in inertial confinement fusion (ICF) implosions with an intermediate distance neutron time-of-flight (nToF) detector

A concept for using an intermediate distance (0.3–3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

Moore, A. S. (ORCID:0000000221258882)↗

TRINIDI (Time-of-Flight Resonance Imaging with Neutrons for Isotopic Density Inference)

This software is an open-source Python library that provides tools for processing hyperspectral neutron time-of-flight radiography data. This type of data allows material decomposed reconstructions to be generated with the use of material characteristic spectral responses and the algorithms provided in this code library. The software library will contain tools for pre-processing the neutron measurement data, estimating measurement system parameters, reconstructing material decomposed radiographs, and computing material decomposed computed tomography (CT). Furthermore, it will have capability to generate and process simulated neutron time-of-flight data with the goal of benchmarking and demonstrating the tools that are provided. The software will include thorough documentation and application examples.

Balke, Thilo↗

Simultaneous analysis of collinear neutron time-of-flight (nToF) traces applied to pulsed fusion experiment

On pulsed fusion experiments, the neutron time of flight (nToF) diagnostic provides critical information on the fusion neutron energy spectrum. This work presents an analysis technique that uses two collinear nToF detectors, potentially to measure nuclear bang time and directional flow velocities. Two collinear detectors may be sufficient to disambiguate the contributions of nuclear bang time and directional flow velocities to the first moment of the neutron energy spectrum, providing an independent measurement of nuclear bang time. In conclusion, preliminary results from measured nToF traces on the National Ignition Facility and additional applications of this technique are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The time-of-flight system on the Goddard medium energy gamma-ray telescope

A scintillation counter time-of-flight system has been incorporated into the Goddard 50 cm by 50 cm spark chamber gamma-ray telescope. This system, utilizing constant fraction timing and particle position compensation, digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns. Event selection decisions, discriminating against upward-moving particles, are made prior to spark chamber triggering. The performance of this system during a November 1978 balloon flight is discussed.

Ross, R. W.↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

Two-step Laser Time-of-Flight Mass Spectrometry to Elucidate Organic Diversity in Planetary Surface Materials.

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) holds promise to be a low-mass, compact in situ analytical capability for future landed missions to planetary surfaces. The ability to analyze a solid sample for both mineralogical and preserved organic content with laser ionization could be compelling as part of a scientific mission pay-load that must be prepared for unanticipated discoveries. Targeted missions for this instrument capability include Mars, Europa, Enceladus, and small icy bodies, such as asteroids and comets.

Europa↗

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Biomark/Organic Analysis with Time-of-Flight Mass Spectrometry

The concept of a Comprehensive 2-Dimensional Gas Chromatography coupled with Time-of-Flight Mass Spectrometry (GCxGC-TOWS) for the analysis of organic compounds has been proven with commercially available instrumentation (LECO Corp). The performance of a GCxGC instrument has been characterized in various stages using two independent breadboard systems. The GCxGC separation systems, including the thermal modulator, have been miniaturized to the size of a benchtop configuration. One breadboard system employs a Flame Ionization Detector (FID), whereas the second breadboard system employs a Time-of-Fight mass spectrometer (TOFWS) as a detection system.

Waite, J. Hunter, Jr.↗

Video Guidance Sensor and Time-of-Flight Rangefinder

A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The additional timing and control signals generated by the FPGA would cause the VGS to alternate between an imaging (direction-finding) mode and a time-of-flight (range-finding mode) and would govern operation in the range-finding mode.

Bryan, Thomas↗

Time-of-flight velocity analysis of atomic and molecular beams

Conditions required for resolving a given beam speed distribution were evaluated by calculating the time-of-flight (TOF) signal for a finite open time of the beam shutter. Design criteria for a beam chopper and detection system are discussed in terms of the resolution, the range of speeds to be measured, and the optimum signal to noise ratio. A TOF system for detection of high intensity molecular beams with large speed ratios, as well as for low intensity scattered beams, is described. Experimental results are presented.

Hagena, O. F.↗

Inference of the neutron down-scatter ratio using neutron time-of-flight data for DT-layered implosions on the OMEGA laser

First analysis of the neutron time of flight (nTOF) data is presented to infer the areal density using the neutron down-scatter ratio (DSR) for OMEGA deuterium–tritium (DT)-layered (cryogenic) implosions. The required very-high-dynamic range (nTOF) signal is constructed using an nTOF detector [Forrest et al., Rev. Sci. Ins. 83, 10D919 (2012)] with multiple time-gated photomultiplier tubes. The nTOF data are analyzed using a forward-fit technique to account for the detector responses and infer the DSR and areal density for DT-layered implosions. The areal densities inferred using this analysis are found to be in agreement with the areal densities measured using the magnetic recoil spectrometer detector that is located in a similar line-of-sight. This work establishes the feasibility of the DSR measurement using nTOF data on OMEGA and provides an additional areal-density measurement that will benefit the assessment of the implosion performance and 3D reconstruction of the imploded core.

47 OTHER INSTRUMENTATION↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗