Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Study of Large Droplet Ice Accretion in the NASA Lewis IRT at Near-Freezing Conditions

Results of experiments designed to determine the effects of large droplet ice accretion on a NACA 23012 wing section are presented. Using primarily an icing condition with a median volumetric diameter droplet size of 160 micron and a liquid water content of 0.82 grams per cubic meter, the effects of various air temperatures, angles of attack, and de-icer boot cycle interval times on ice accretion were studied. Measurements of aerodynamic performance penalties due to the ice accretions were made. Results were also compared with similar tests conducted with a Twin Otter wing section in Part 1 of this study. The form of the ice from the large droplet cloud varied as a function of air total temperature; particularly at the near-freezing temperatures of 28 F to 34 F. Changing boot cycle interval time did not prevent formation of an ice ridge. The most detrimental aerodynamic effects occurred at an air total temperature of 28 F.

Addy, Harold E., Jr.↗

Large-Drop Ice Accretion Test Results for a Large Scale Swept Wing Model

In-flight icing is an important consideration that affects aircraft design, performance and safety. Newer regulations combined with increasing demand to reduce fuel burn, emissions and noise are driving a need for improvements in icing simulation capability. To that end, this paper presents the results of ice accretion testing conducted in the NASA Icing Research Tunnel on a large swept wing section typical of a modern commercial transport. The model was based upon a section of the Common Research Model wing at the 64% semispan station with a streamwise chord length of 136 in. The test conditions were developed with an icing scaling analysis to generate similar conditions for a small MVD = 25 μm and a large MVD = 110 μm. A series of tests were conducted over a range of total temperature from -23.8 ˚C to -1.4 ˚C with all other conditions held constant. The results for the small MVD cloud conditions were consistent with previous work and showed the changing ice morphology from rime ice at colder temperatures to highly 3D scallop ice in the range of -8.7 ˚C to -3.8 ˚C. The results for the large MVD cloud conditions exhibited some differences in the ice accretion morphology from the small MVD conditions. Scallop-like ice features were observed at total temperature of -3.8˚C. The large MVD ice accretion at lower temperatures tended to be smoother than the corresponding ice accretion for small MVD. The thickness of the main ice shape tended to be larger for the small MVD conditions compared to the corresponding large MVD ice shape while the latter had more ice farther downstream. The measured ice mass was approximately equal between the corresponding small and large MVD ice shapes up to a freezing fraction of 0.6. For higher freezing fraction, the large MVD ice shapes weighed more. Cloud MVD variation from 50 μm to 230 μm while holding the scaling parameters constant resulted in very minor differences in the ice shapes, mostly in the upper and lower surface chordwise extents. Ice volume was computed from 3D scan data and used to calculate a ratio of ice mass to volume. The resulting values were in the range of 240 to 455 Kg/m3. While this is consistent with analogous values previously reported in the literature, more data are needed to determine a specific trend in this ratio as a function of freezing fraction and the corresponding governing physical phenomena. This work has resulted in a significant experimental database of ice accretion for small and large MVD conditions applicable to large-scale swept wings.

Icing↗

Effect of Steady-State Temperature Distortion on Inlet Flow to a High-Bypass-Ratio Turbofan Engine

The effects of circumferential inlet temperature distortion on the flow characteristics between a distortion generator and a high bypass ratio turbofan engine and through its compression system were evaluated to support the effort to generate analytical models. The flow characteristics are defined by the inlet duct, the flow angles, and the total temperature, total pressure, and static pressure profiles in the inlet duct and through the fan and compressor. The effects of Reynolds number, rotor speed, and distortion extent are also considered.

Soeder, R. H.↗

A study of nonadiabatic boundary-layer stabilization time in a cryogenic tunnel for typical wing and fuselage models

A theoretical study has been made of the time varying effect of nonadiabatic wall conditions on boundary layer properties for a two-dimensional wing section and an axisymmetric body of revolution typical of a fuselage. The wing section and body of revolution are representative of the root chord and fuselage of what is considered to be a typical size transport model for the National Transonic Facility. The transient analysis was made at a Mach number of 0.85, for stagnation pressures of 2, 6, and 9 atmospheres at several cryogenic values of total temperature for a solid wing and for three different fuselage skin thickness configurations. The analysis considered wing and fuselage sections made from stainless steel, beryllium copper, and aluminum. Examples are presented that may be used to determine the time required to reach an adiabatic condition after a change in total temperature.

Johnson, C. B.↗

Aero-Thermal Calibration of the NASA Glenn Icing Research Tunnel (2004 and 2005 Tests)

A full aero-thermal calibration of the NASA Glenn Icing Research Tunnel was completed in 2004 following the replacement of the inlet guide vanes upstream of the tunnel drive system and improvement to the facility total temperature instrumentation. This calibration test provided data used to fully document the aero-thermal flow quality in the IRT test section and to construct calibration curves for the operation of the IRT. The 2004 test was also the first to use the 2-D RTD array, an improved total temperature calibration measurement platform.

Arrington, E. Allen↗

Effect of Air Cooling of Turbine Disk on Power and Efficiency of Turbine from Turbo Engineering Corporation TT13-18 Turbosupercharger.

An investigation was conducted to determine the effect of turbine-disk cooling with air on the efficiency and the power output of the radial-flow turbine from the Turbo Engineering Corporation TT13-18 turbosupercharger. The turbine was operated at a constant range of ratios of turbine-inlet total pressure to turbine-outlet static pressure of 1,5 and 2.0, turbine-inlet total pressure of 30 inches mercury absolute, turbine-inlet total temperature of 12000 to 20000 R, and rotor speeds of 6000 to 22,000 rpm, Over the normal operating range of the turbine, varying the corrected cooling-air weight flow from approximately 0,30 to 0.75 pound per second produced no measurable effect on the corrected turbine shaft horsepower or the turbine shaft adiabatic efficiency. Varying the turbine-inlet total temperature from 12000 to 20000 R caused no measurable change in the corrected cooling-air weight flow. Calculations indicated that the cooling-air pumping power in the disk passages was small and was within the limits of the accuracy of the power measurements. For high turbine power output, the power loss to the compressor for compressing the cooling air was approximately 3 percent of the total turbine shaft horsepower.

Berkey, William E.↗

Unsteady Flow in Multistage Turbines

The development of an efficient model for the response of a multistage turbine to either a total pressure or total temperature distortion is discussed. Each turbine blade row is modeled as an actuator disk and is often used to describe the flow through turbine and compressor blade rows. The flow approaching the blade row is assumed to be subsonic and inviscid. The distortion occurs at upstream infinity and is in the form of total pressure or total temperature. A solution was found to unsteady Euler equations by using a finite volume method. With prescribed inlet and boundary conditions flow variables such as density, pressure, and velocities can be calculated at cell centers in the entire flow region. The inlet and exit of the blade row coincide with lines of constant.

Surampudi, S. P.↗

Boundary layer study on nozzle wall at hypersonic velocities

The boundary layer on the wall of the Hypervelocity Tunnel 9 was investigated with pitot pressure and total temperature measurements. Experimental results are presented for standard and supercooled Mach 14 runs. The boundary layer data at supercooled conditions are compared to numerical predictions made with a Navier-Stokes algorithm including vibrational nonequilibrium and intermolecular force effects. For standard tunnel conditions, the numerical solutions agree well with experimental data. For the supercooled cases, the numerical code predicts the total temperature but overpredicts the pitot pressure.

Jones, Kenneth M.↗

Rod Internal Pressure Distribution and Uncertainty Analysis Using FRAPCON

The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data, and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed that tracks intercycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB 2 ) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rod–specific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB 2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rods without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd/tonne U is determined to be the total fuel rod void volume and the amount of released fission gas in the fuel rod, respectively. Cumulative distribution functions (CDFs) are prepared from the distribution of RIP and CHS predictions for all standard and IFBA rods. The provided CDFs allow for the determination of the portion of WBN1 fuel rods that exceeds a specified RIP or CHS limit. Results are separated into IFBA and standard rods so that the two groups may be analyzed individually. FRAPCON results are provided in sufficient detail to enable the recalculation of the RIP while considering any desired plenum gas temperature, total void volume, or total amount of gas present in the void volume. A method to predict the CHS from a determined or assumed RIP is also proposed that is based on the approximately linear relationship between the CHS and the RIP. Finally, improvements to the computational methodology of FRAPCON are proposed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SSME Turbopump Turbine Computations

A two-dimensional viscous code was developed to be used in the prediction of the flow in the SSME high-pressure turbopump blade passages. The rotor viscous code (RVC) employs a four-step Runge-Kutta scheme to solve the two-dimensional, thin-layer Navier-Stokes equations. The Baldwin-Lomax eddy-viscosity model is used for these turbulent flow calculations. A viable method was developed to use the relative exit conditions from an upstream blade row as the inlet conditions to the next blade row. The blade loading diagrams are compared with the meridional values obtained from an in-house quasithree-dimensional inviscid code. Periodic boundary conditions are imposed on a body-fitted C-grid computed by using the GRAPE GRids about Airfoils using Poisson's Equation (GRAPE) code. Total pressure, total temperature, and flow angle are specified at the inlet. The upstream-running Riemann invariant is extrapolated from the interior. Static pressure is specified at the exit such that mass flow is conserved from blade row to blade row, and the conservative variables are extrapolated from the interior. For viscous flows the noslip condition is imposed at the wall. The normal momentum equation gives the pressure at the wall. The density at the wall is obtained from the wall total temperature.

Jorgenson, P. G. E.↗

The Scaling of Broadband Shock-Associated Noise with Increasing Temperature

A physical explanation for the saturation of broadband shock-associated noise (BBSAN) intensity with increasing jet stagnation temperature has eluded investigators. An explanation is proposed for this phenomenon with the use of an acoustic analogy. For this purpose the acoustic analogy of Morris and Miller is examined. To isolate the relevant physics, the scaling of BBSAN at the peak intensity level at the sideline ( = 90 degrees) observer location is examined. Scaling terms are isolated from the acoustic analogy and the result is compared using a convergent nozzle with the experiments of Bridges and Brown and using a convergent-divergent nozzle with the experiments of Kuo, McLaughlin, and Morris at four nozzle pressure ratios in increments of total temperature ratios from one to four. The equivalent source within the framework of the acoustic analogy for BBSAN is based on local field quantities at shock wave shear layer interactions. The equivalent source combined with accurate calculations of the propagation of sound through the jet shear layer, using an adjoint vector Green s function solver of the linearized Euler equations, allows for predictions that retain the scaling with respect to stagnation pressure and allows for the accurate saturation of BBSAN with increasing stagnation temperature. This is a minor change to the source model relative to the previously developed models. The full development of the scaling term is shown. The sources and vector Green s function solver are informed by steady Reynolds-Averaged Navier-Stokes solutions. These solutions are examined as a function of stagnation temperature at the first shock wave shear layer interaction. It is discovered that saturation of BBSAN with increasing jet stagnation temperature occurs due to a balance between the amplification of the sound propagation through the shear layer and the source term scaling.A physical explanation for the saturation of broadband shock-associated noise (BBSAN) intensity with increasing jet stagnation temperature has eluded investigators. An explanation is proposed for this phenomenon with the use of an acoustic analogy. For this purpose the acoustic analogy of Morris and Miller is examined. To isolate the relevant physics, the scaling of BBSAN at the peak intensity level at the sideline psi = 90 degrees) observer location is examined. Scaling terms are isolated from the acoustic analogy and the result is compared using a convergent nozzle with the experiments of Bridges and Brown and using a convergent-divergent nozzle with the experiments of Kuo, McLaughlin, and Morris at four nozzle pressure ratios in increments of total temperature ratios from one to four. The equivalent source within the framework of the acoustic analogy for BBSAN is based on local field quantities at shock wave shear layer interactions. The equivalent source combined with accurate calculations of the propagation of sound through the jet shear layer, using an adjoint vector Green s function solver of the linearized Euler equations, allows for predictions that retain the scaling with respect to stagnation pressure and allows for the accurate saturation of BBSAN with increasing stagnation temperature. This is a minor change to the source model relative to the previously developed models. The full development of the scaling term is shown. The sources and vector Green s function solver are informed by steady Reynolds-Averaged Navier-Stokes solutions. These solutions are examined as a function of stagnation temperature at the first shock wave shear layer interaction. It is discovered that saturation of BBSAN with increasing jet stagnation temperature occurs due to a balance between the amplification of the sound propagation through the shear layer and the source term scaling.

Miller, Steven A.↗

Measurement of Turbulent Pressure and Temperature Fluctuations in a Gas Turbine Combustor

The report summarizes the results of the redesign efforts directed towards the gas-turbine combustor rapid-injector flow diagnostic probe developed under sponsorship of NASA-GRC and earlier reported in NASA-CR-2003-212540. Lessons learned during the theoretical development, developmental testing and field-testing in the previous phase of this research were applied to redesign of both the probe sensing elements and of the rapid injection device. This redesigned probe (referred to herein as Turboprobe) has been fabricated and is ready, along with the new rapid injector, for field-testing. The probe is now designed to capture both time-resolved and mean total temperatures, total pressures and, indirectly, one component of turbulent fluctuations.

Povinelli, Louis↗

The effect of unsteadiness on the time-mean thermal loads in a turbine stage

Two steady numerical analysis methods and one unsteady method are used to study the viscous three-dimensional flow in the middle stage of the Pratt & Whitney alternate design Space Shuttle Main Engine fuel turbine. The principal characteristic of this flow is that the secondary flows generated in the rotor blade reconfigure a radial inlet total temperature distortion into one with a pitchwise exit hot streak distortion. Secondary flows in the following vane redistribute the radial variation while unsteadiness causes a segregation of hot and cold flow from the hot streak within the vane. Such redistribution and segregation can lead to unexpected thermal loads and reduced durability. The physical phenomena and the ability of a steady analysis to capture them are investigated by performing a numerical experiment whereby the results of the two steady analysis methods are compared to the time-mean of the unsteady simulation. The flow physics related to the segregation and mixing of total temperature are discussed.

Kirtley, K. R.↗

The 727 airplane side inlet low-speed performance confirmation model test for refanned JT8D engines

The results of a low-speed wind tunnel test of a 0.3 scale model 727 airplane side inlet for JT8D-100 engines are presented. The objectives of the test were to develop lines for a full-scale flightworthy inlet, to evaluate inlet total pressure recovery and steady-state total pressure distortion, and to obtain model-scale distortion data which can be used in the assessment of the compatibility of the inlet with the JT8D-100 series engines. A secondary objective was to obtain internal/external cowl static pressures for the determination of nacelle loads. Two basic inlet models were tested at static, forward speed, angle-of-attack (inflow angle), and cross-wind conditions. One model was with and one without an acoustic ring. Two modifications to the models were also tested, one with the ring closer to the inlet throat and one with a larger lip. Test measurements consisted of inlet surface static pressure, engine face total pressure, inlet airflow, tunnel total pressure, tunnel total temperature and tunnel velocity. Total pressure traverses were taken directly behind the ring and strut. No dynamic measurements were taken.

Schuehle, A. L.↗

Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30 degree inclination angle.

Wang, C. R.↗

Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center-line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30-deg inclination angle.

Wang, C. R.↗