Search NASA⌕ Search

SEARCH · Search NASA

Results for “total variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantifying Site Effects and Their Influence on Earthquake Source Parameter Estimations Using a Dense Array in Oklahoma

We investigate the effects of site response on source parameter estimates using earthquakes recorded by the LArge-n Seismic Survey in Oklahoma (LASSO). While it is well known that near-surface unconsolidated sediments can cause an apparent breakdown of earthquake self-similarity, the influence of laterally varying site conditions remains unclear. We analyze site conditions across the 1825-station array on a river plain within an area of 40 km by 23 km using vertical ground motions from 14 regional earthquakes. While the source radiation pattern controls P-wave ground motions below 8 Hz, the surface geology correlates with P-wave ground motions above 8 Hz and S-wave ground motions at 2–21 Hz. Stations installed in alluvial sediments have vertical ground motions that can exceed three times the array median. We use the variation of ground motion of regional earthquakes across the array as a proxy for site effects. The corner frequencies and stress drops of local earthquakes ( M L = 0.01–3) estimated using a standard single-spectra approach show negative correlations with the site-effect proxy, while the seismic moments show positive correlations. In contrast, the spectral-ratio approach effectively shows no correlation. The overall bias is small as expected for this relatively homogeneous structure; accurate estimation of site-related biases requires at least 30 stations. Correcting for site-related biases reduces the standard deviations of the source parameters by less than 13% of the total variations. Remaining variations are partially associated with source directivity and model misfits— as small earthquakes can have complex ruptures.

58 GEOSCIENCES↗

Doping-evolution of the superconducting gap in single crystals of (Ca 1- x La x ) 10 (Pt 3 As 8 )(Fe 2 As 2 ) 5 superconductor from London penetration depth measurements

The doping-evolution of the superconducting gap structure in iron-based superconductor (Ca 1-x La x ) 10 (Pt 3 As 8 )(Fe 2 As 2 ) 5 (x = 0.04, 0.06, 0.09, 0.11, and 0.18) was probed by high-resolution measurements of the London penetration depth, λ(T). The samples spanned compositions from underdoped to slightly overdoped with superconducting critical temperatures, T c , from 12.7 K (x = 0.04) through (optimal) 23.3 K (x = 0.11) to 21.9 K (x = 0.18). The low-temperature variation (up to 0.3 T c ) of λ(T) was analysed using a power-law function, Δλ = AT n . For compositions close to the optimal doping, (x = 0.09, 0.11, and 0.18), characterized by T c > 20K, Δλ(T) shows a tendency to saturation, indicative of a full gap on the Fermi surface. Fitting over the lowest temperature range (T < 0.1 T c ) gives n = 2.6. This value is well outside the range 1 ≤ n ≤ 2 expected for the line-nodal superconductor. The exponent n decreased to n ~ 2 in the two most underdoped compositions x = 0.04 (T c = 12.7 K) and 0.06 (T c = 18.2 K), implying the development of a notable gap anisotropy revealed by the enhanced influence of pair-breaking scattering. This decrease is accompanied by a significant increase of the total variation of the penetration depth Δλ in a fixed temperature interval (e.g., T min - 0.3T c ). Both the decrease of the exponent and the increase of the absolute value of Δλ in the underdoped regime are similar to the observations in other charge-doped iron-based superconductors, such as doped BaFe 2 As 2 and NaFeAs, suggesting a universal behavior in iron-based superconductors.

Cho, K.↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

Linear functional minimization for inverse modeling

In this paper, we present a novel inverse modeling strategy to estimate spatially distributed parameters of nonlinear models. The maximum a posteriori (MAP) estimators of these parameters are based on a likelihood functional, which contains spatially discrete measurements of the system parameters and spatiotemporally discrete measurements of the transient system states. The piecewise continuity prior for the parameters is expressed via Total Variation (TV) regularization. The MAP estimator is computed by minimizing a nonquadratic objective equipped with the TV operator. We apply this inversion algorithm to estimate hydraulic conductivity of a synthetic confined aquifer from measurements of conductivity and hydraulic head. The synthetic conductivity field is composed of a low-conductivity heterogeneous intrusion into a high-conductivity heterogeneous medium. Our algorithm accurately reconstructs the location, orientation, and extent of the intrusion from the steady-state data only. Finally, addition of transient measurements of hydraulic head improves the parameter estimation, accurately reconstructing the conductivity field in the vicinity of observation locations.

47 OTHER INSTRUMENTATION↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Central Compact Finite‐Difference Scheme With High Spectral Resolution for KdV Equation

This work presents a combination of cell‐node and cell‐centered compact finite difference scheme for the approximation of third derivatives involved in Korteweg–de Vries (KdV) equations. This approach employs a half‐shifted derivative construction at cell centers, avoiding the need for compact interpolation, thereby removing transfer errors; hence, it improves spectral resolution and maintains high‐order accuracy. Fourier analysis is performed to show the spectral properties of the proposed formulation, which provides higher spectral resolutions as compared to node‐based compact schemes. A filtering strategy is incorporated to suppress high‐frequency oscillations without compromising the accuracy of the numerical scheme, and the total variation diminishing Runge Kutta (TVDRK3) method is applied for time integration. Numerical experiments on linear, nonlinear, and coupled KdV systems are conducted, and a comparative analysis with cell‐node compact schemes confirms that the proposed scheme consistently reduces errors by up to an order of magnitude and achieves high spectral resolution properties.

97 MATHEMATICS AND COMPUTING↗

Landscaping the strong CP problem

One often hears that the strong CP problem is the one problem which cannot be solved by anthropic reasoning. We argue that this is not so. Due to nonperturbative dynamics, states with a different CP violating paramenter θ acquire different vacuum energies after the QCD phase transition. These add to the total variation of the cosmological constant in the putative landscape of Universes. An interesting possibility arises when the cosmological constant is mostly cancelled by the membrane nucleation mechanism. If the step size in the resulting discretuum of cosmological constants, ΔΛ, is in the interval (meV) 4 < ΔΛ < (100 MeV) 4 , the cancellation of vacuum energy can be assisted by the scanning of θ. For (meV) 4 < ΔΛ < (keV) 4 this may yield θ < 10 -10 , meeting the observational limits. This scenario opens up 24 orders of magnitude of acceptable parameter space for ΔΛ compared to membrane nucleation acting alone. In such a Universe one may not need a light axion to solve the strong CP problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong Stability Preserving Integrating Factor Two-Step Runge-Kutta Methods

In this report, problems with components that feature significantly different time scales, where the stiff time-step restriction comes from a linear component, implicit-explicit (IMEX) methods alleviate this restriction if the concern is linear stability. However, when nonlinear non-inner-product stability properties are of interest, such as in the evolution of hyperbolic partial differential equations with shocks or sharp gradients, linear inner-product stability is no longer sufficient for convergence, and so strong stability preserving (SSP) methods are often needed. Where the SSP property is needed, IMEX SSP Runge-Kutta (SSP-IMEX) methods have very restrictive time-steps. An alternative to SSP-IMEX schemes is to adopt an integrating factor approach to handle the linear component exactly and step the transformed problem forward using some time-evolution method. The strong stability properties of integrating factor Runge-Kutta methods were established in Isherwood et al. (SIAM J Numer Anal 56(6):3276–3307, 2018), where it was shown that it is possible to define explicit integrating factor Runge-Kutta methods that preserve strong stability properties satisfied by each of the two components when coupled with forward Euler time-stepping. It was proved that the solution will be SSP if the transformed problem is stepped forward with an explicit SSP Runge-Kutta method that has non-decreasing abscissas. However, explicit SSP Runge-Kutta methods have an order barrier of p=4, and sometimes higher order is desired. In this work we consider explicit SSP two-step Runge-Kutta integrating factor methods to raise the order. We show that strong stability is ensured if the two-step Runge-Kutta method used to evolve the transformed problem is SSP and has non-decreasing abscissas. We find such methods up to eighth order and present their SSP coefficients. Adding a step allows us to break the fourth order barrier on explicit SSP Runge-Kutta methods; furthermore, our explicit SSP two-step Runge-Kutta methods with non-decreasing abscissas typically have larger SSP coefficients than the corresponding one-step methods. A selection of our methods are tested for convergence and demonstrate the design order. We also show, for selected methods, that the SSP time-step predicted by the theory is a lower bound of the allowable time-step for linear and nonlinear problems that satisfy the total variation diminishing (TVD) condition. We compare some of the non-decreasing abscissa SSP two-step Runge-Kutta methods to previously found methods that do not satisfy this criterion on linear and nonlinear TVD test cases to show that this non-decreasing abscissa condition is indeed necessary in practice as well as theory. We also compare these results to our SSP integrating factor Runge-Kutta methods designed in Isherwood et al. (2018).

97 MATHEMATICS AND COMPUTING↗

Reduction of amplified spontaneous emission noise using a statistical signal adaptive filter

This paper proposes a statistical signal adaptive filter (SSAF) based on adaptive total variation to reduce amplified spontaneous emission (ASE) noise in optical amplifiers, e.g. erbium doped fiber amplifiers. Non-return-to-zero on–off keying signal to noise ratio (SNR) is degraded by ASE noise. However, this can be improved by squeezing ASE using the proposed SSAF after photodetection to effectively remove the noise by analyzing the signal movement statistically. We obtained 4-dB SNR gain by reducing ASE beat noise compared with not applying SSAF. Simultaneous optical bandpass filter and SSAF application reduced the 2-dB power penalty for a 20-km optical link more than when only SSAF was used.

36 MATERIALS SCIENCE↗

A higher-order Lagrangian discontinuous Galerkin hydrodynamic method for solid dynamics

We present a new multidimensional high-order Lagrangian discontinuous Galerkin (DG) hydrodynamic method that supports hypoelastic and hyperelastic strength models for simulating solid dynamics with higher-order elements. We also present new one-dimensional test problems that have an analytic solution corresponding to a hyperelastic–plastic wave. A modal DG approach is used to evolve fields relevant to conservation laws. These fields are approximated high-order Taylor series polynomials. The stress fields are represented using nodal quantities. The constitutive models used to calculate the deviatoric stress are either a hypoelastic–plastic, infinitesimal strain hyperelastic–plastic, or finite strain hyperelastic–plastic model. These constitutive models require new methods for calculating high-order polynomials for the velocity gradient and deformation gradient in an element. The plasticity associated with the strength model is determined using a radial return method to with a J 2 yield criterion and perfect plasticity. The temporal evolution of the governing equations is achieved with the total variation diminishing Runge–Kutta (TVD RK) time integration method. A diverse suite of 1D and 2D test problems are calculated. Here, the new 1D piston test problems, which have analytic solutions for each elastic–plastic model, are presented and calculated to demonstrate the stability and formal accuracy of the various models with the new Lagrangian DG method. 2D test problems are calculated to demonstrate the stability and robustness of the new Lagrangian DG method on multidimensional problems with high-order elements, which have faces that can bend.

42 ENGINEERING↗

Controlling risk and demand ambiguity in newsvendor models

We use distributionally robust optimization (DRO) to model a general class of newsvendor problems with unknown demand distribution. The goal is to find an order quantity that minimizes the worst-case expected cost among an ambiguity set of distributions. The ambiguity set consists of those distributions that are not far—in the sense of the total variation distance—from a nominal distribution. The maximum distance allowed in the ambiguity set (called level of robustness) places the DRO between the risk-neutral stochastic programming and robust optimization models. An important problem a decision maker faces is how to determine the level of robustness—or, equivalently, how to find an appropriate level of risk-aversion. We answer this question in two ways. Our first approach relates the level of robustness and risk to the regions of demand that are critical (in a precise sense we introduce) to the optimal cost. Our second approach establishes new quantitative relationships between the DRO model and the corresponding risk-neutral and classical robust optimization models. To achieve these goals, we first focus on a single-product setting and derive explicit formulas and properties of the optimal solution as a function of the level of robustness. Then, we demonstrate the practical and managerial relevance of our results by applying our findings to a healthcare problem to reserve operating room time for cardiovascular surgeries. Finally, we extend some of our results to the multi-product setting and illustrate them numerically.

99 GENERAL AND MISCELLANEOUS↗

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction

Purpose: To evaluate the performance of a 4-dimensional (4-D) cone-beam computed tomographic (CBCT) reconstruction scheme based on simultaneous motion estimation and image reconstruction (SMEIR) through patient studies. Methods and Materials: The SMEIR algorithm contains 2 alternating steps: (1) motion-compensated CBCT reconstruction using projections from all phases to reconstruct a reference phase 4D-CBCT by explicitly considering the motion models between each different phase and (2) estimation of motion models directly from projections by matching the measured projections to the forward projection of the deformed reference phase 4D-CBCT. Four lung cancer patients were scanned for 4 to 6 minutes to obtain approximately 2000 projections for each patient. To evaluate the performance of the SMEIR algorithm on a conventional 1-minute CBCT scan, the number of projections at each phase was reduced by a factor of 5, 8, or 10 for each patient. Then, 4D-CBCTs were reconstructed from the down-sampled projections using Feldkamp-Davis-Kress, total variation (TV) minimization, prior image constrained compressive sensing (PICCS), and SMEIR. Using the 4D-CBCT reconstructed from the fully sampled projections as a reference, the relative error (RE) of reconstructed images, root mean square error (RMSE), and maximum error (MaxE) of estimated tumor positions were analyzed to quantify the performance of the SMEIR algorithm. Results: The SMEIR algorithm can achieve results consistent with the reference 4D-CBCT reconstructed with many more projections per phase. With an average of 30 to 40 projections per phase, the MaxE in tumor position detection is less than 1 mm in SMEIR for all 4 patients. Conclusion: The results from a limited number of patients show that SMEIR is a promising tool for high-quality 4D-CBCT reconstruction and tumor motion modeling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗