Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Al III, Si IV, and C IV absorption toward zeta Ophiuchi: Evidence for photionized and collisionally ionized gas

We present Goddard High-Resolution Spectrograph observations at 3.5 km/s resolution and signal-to-noise ratios of 30 to 60 for the Al III, Si IV, and N V absorption lines in the far-ultraviolet spectrum of the O9.5 V star zeat Ophiuchi. The measurement reveal three types of highly ionized gas along the 140 pc line of sight. (1) Narrow components of Al III (b = 4.3 km/s, the mean value of (v(helio)) = -7.8 km/s; b = 3.2 km/s, the mean value of (v(sub helio)) = -14.4 km/s) and Si IV (b = 5.3 km/s, the mean value of (v(sub helio)) = -15.0 km/s) trace photionized gas in the expanding H II region surrounding zeta Oph. The observed magnitude and direction of the velocity offset between the Al III and Si IV profiles can be explained by models of H II regions that incorporate expansion. Narrow C IV absorption associated with the H II region is not detected. Predictions of the expected amounts of Si IV and C IV overestimate the column densities of these ions by factors of 30 and more than 10, respectively. The discrepancy may be due to the effects of elemental depletions in the gas and/or to the interaction of the stellar wind with surrounding matter. (2) Broad (b = 15 to 18 km/s) and weak Si IV and C IV absorption components are detected near the mean value of (v(sub helio)) = -26 km/s. The high-ionization species associated with these absorption components are probably produced by electron collisional ionization in a heated gas. This absorption may be physically related to the zeta Oph bow shock ot to a cloud complex situated within the local interstellar medium at d less than 60 pc. The C IV to Si IV column density ratio in this gas is 8, a factor of 6 less than conductive interface models predict, but this discrepancy may be removed by considering the effects of self-photoionization within the cooling gas in the model calculations. (3) A broad (b = 13 km/s) and weak C IV absorption feature detected at the mean value of (v(sub helio)) = -61 km/s is not seen in other species. We tentatively ascribe this absorption to gas in a postshock ragion of an optically thin shock in the zeta Oph stellar wind.

Sembach, Kenneth R.↗

Consistent Controls on Trace Metal Micronutrient Speciation in Wetland Soils and Stream Sediments

Trace metal are essential for microbially-mediated biogeochemical processes occurring in anoxic wetland soils and stream bed sediments, but low availability of these elements may inhibit anaerobic element cycling and transformations. Solid-phase speciation is likely a critical control on trace metal availability but has seen limited study in anoxic systems having concentrations similar to geological background levels, where metal limitations may be most prevalent. We have investigated trace metal concentrations and solid-phase speciation in three freshwater subsurface aquatic systems: marsh wetland soils, riparian wetland soils, and the sediments of a streambed. These systems displayed low solid-phase trace metal concentrations, generally at or below geological background levels, which generally followed the trend Zn > Cu ≈ Ni > Co and showed no correlation with major element compositions. All soils and sediments were dominated by quartz but varied in clay mineralogy as well as the organic matter, total sulfur, and total iron contents. X-ray absorption near-edge structure (XANES) spectroscopy shows that sulfur speciation in both wetlands is dominated by organic sulfur. Elemental sulfur and iron sulfides together made up <25% of the sulfur in the wetland soils, but the distribution between inorganic and organic forms was reversed in the stream sediments. Ferrous and ferric iron in clay minerals were common species identified by both XANES and extended X-ray absorption fine structure (EXAFS) spectroscopies at all sites. Iron(III) oxides were substantial components in all but the marsh wetland soils. Quantitative analysis of copper, nickel, and zinc XANES spectra revealed similar metal speciation across all sites. Copper speciation was dominated by sulfides, adsorbed species, and minor amounts of copper bound to organic matter; no metallic copper was detected. Nickel speciation also varied little and was dominated by nickel in clay mineral octahedral sheets and nickel sulfide, with adsorbed species also present. Zinc speciation was slightly more varied, with the marsh wetland soils and stream bed sediments containing adsorbed species, zinc associated with clay mineral structures, and zinc bound to reduced sulfur groups on organic matter, whereas the riparian wetland soils lacked clay-associated zinc but contained zinc sulfide. Trace metals bound to reduced sulfur occurred at every site, with a greater sulfur-bound fraction for copper. The fractional abundance of sulfur-bound species showed no relationship with soil or sediment total sulfur content, which varied by two orders of magnitude. More broadly, the observations in this study suggest that trace metal speciation in freshwater wetland soils and stream sediments is consistently dominated by a small set of recurring components which are distinct for each metal. Furthermore, this may represent a general geochemical phenomenon in anoxic soils and sediments containing trace metals at background concentrations (as low as 3 µg g -1 ) that was not predicted from systems that are contaminated with or naturally-enriched in copper, nickel, or zinc.

54 ENVIRONMENTAL SCIENCES↗

Rapid simulation of X-ray scatter measurements for threat detection via GPU-based ray-tracing

Scatter-based X-ray imaging has increased in prominence in areas ranging from cancer diagnostics to threat detection in aviation security, due largely to the development of new algorithms and components over the last decade. However, system design and algorithm development are often hindered by an inability to generate a sucient amount of accurate data. To further the development of scatter-based systems, we created a rapid X-ray scatter simulation tool built with a GPU-centric, parallel ray-tracing framework (NVIDIA OptiX). This tool models a full range of X-ray imaging components and describes 3D objects formed with heterogeneous media using polygon meshes. The scatter simulation algorithm we used is similar to the previously-described hybrid approach; however, instead of employing Monte Carlo techniques, we developed a purely analytical algorithm to sample the distribution of single-scatter events throughout the region of interest. The contribution of scattered photons to the measured signal is then calculated using the first-Born approximation. Here, the accuracy of the implemented pipeline has been validated by comparing simulated against experimental data obtained with a laboratory X-ray scattering system and phantoms of varied materials. Using a single desktop computer with an NVIDIA GTX 770 GPU, we show that the scatter signal generated by an incident fan beam and recorded by a 125 125 element detector array can be simulated in on the order of a few to tens of minutes (depending on the object extent and complexity). As a point of comparison, simulations performed via CPU-based Monte Carlo tools, such as GEANT4 (i.e., the gold standard), can take up to tens of hours to achieve comparable results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron microprobe analysis of trace elements in minerals at 10 PPM concentrations

An improved technique is developed for measuring backgrounds during trace element analysis of crystals and glass using electron microprobes. This technique overcomes major difficulties encountered with conventional techniques, such as the problem of obtaining the net X-ray intensity of the characteristic emission line of interest with sufficient precision and accuracy, as well as the error due to the inability to directly measure the intensity at the wavelength of the characteristic line on the sample being analyzed. It is shown that this technique can yield reproducible results to within 4 ppm in olivine, and has a minimum uncertainty and detection limit of 10 ppm Nd in olivine.

Mckay, G. A.↗

Water Vapor Sensors Go Sky-High to Assure Aircraft Safety

JPL used a special tunable diode laser, which NASA scientists could tune to different wavelengths, like a radio being tuned to different frequencies, to accurately target specific molecules and detect small traces of gas. This tunable diode laser was designed to emit near-infrared light at wavelengths absorbed by the gas or gases being detected. The light energy being absorbed by the target gas is related to the molecules present. This is usually measured in parts per million or parts per billion. Multiple measurements are made every second, making the system quick to respond to variations in the target gas. NASA scientists developed this technology as part of the 1999 Mars Polar Lander mission to explore the possibility of life-giving elements on Mars. NASA has since used the tunable diode laser-based gas sensor on aircraft and on balloons to successfully study weather and climate, global warming, emissions from aircraft, and numerous other areas where chemical gas analysis is needed. SpectraSensors, Inc., was formed in 1999 as a spinoff company of JPL, to commercialize tunable diode laser-based analyzers for industrial gas-sensing applications (Spinoff 2000). Now, the San Dimas, California-based firm has come back to the market with a new product featuring the NASA-developed instrument for atmospheric monitoring. This instrument is now helping aircraft avoid hazardous weather conditions and enabling the National Weather Service to provide more accurate weather forecasts.

Source record↗

Detailed Abundances in the Ultra-faint Magellanic Satellites Carina II and III

We present the first detailed elemental abundances in the ultra-faint Magellanic satellite galaxies Carina II (Car II) and Carina III (Car III). With high-resolution Magellan/MIKE spectroscopy, we determined the abundances of nine stars in Car II, including the first abundances of an RR Lyrae star in an ultra-faint dwarf galaxy (UFD), and two stars in Car III. The chemical abundances demonstrate that both systems are clearly galaxies and not globular clusters. The stars in these galaxies mostly display abundance trends matching those of other similarly faint dwarf galaxies: enhanced but declining [α/Fe] ratios, iron-peak elements matching the stellar halo, and unusually low neutron-capture element abundances. One star displays a low outlying [Sc/Fe] = −1.0. We detect a large Ba scatter in Car II, likely due to inhomogeneous enrichment by low-mass asymptotic giant branch star winds. The most striking abundance trend is for [Mg/Ca] in Car II, which decreases from +0.4 to −0.4 and indicates clear variation in the initial progenitor masses of enriching core-collapse supernovae. So far, the only UFDs displaying a similar [Mg/Ca] trend are likely satellites of the Large Magellanic Cloud. We find two stars with [Fe/H] ≤ −3.5 whose abundances likely trace the first generation of metal-free Population III stars and are well fit by Population III core-collapse supernova yields. An appendix describes our new abundance uncertainty analysis that propagates line-by-line stellar parameter uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activation analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology

Abstract The brain is a privileged organ with regard to its trace element composition and maintains a robust barrier system to sequester this specialized environment from the rest of the body and the vascular system. Stroke is caused by loss of adequate blood flow to a region of the brain. Without adequate blood flow ischaemic changes begin almost immediately, triggering an ischaemic cascade, characterized by ion dysregulation, loss of function, oxidative damage, cellular degradation, and breakdown of the barrier that helps maintain this environment. Ion dysregulation is a hallmark of stroke pathophysiology and we observe that most elements in the brain are dysregulated after stroke. X-ray fluorescence-based detection of physiological changes in the neurometallome after stroke reveals profound ion dysregulation within the lesion and surrounding tissue. Not only are most elements significantly dysregulated after stroke, but the level of dysregulation cannot be predicted from a cell-level description of dysregulation. X-ray fluorescence imaging reveals that the stroke lesion retains <25% of essential K+ after stroke, but this element is not concomitantly elevated elsewhere in the organ. Moreover, elements like Na+, Ca2+, and Cl− are vastly elevated above levels available in normal brain tissue (>400%, >200%, and >150%, respectively). We hypothesize that weakening of the blood–brain barrier after stroke allows elements to freely diffuse down their concentration gradient so that the stroke lesion is in equilibrium with blood (and the compartments containing brain interstitial fluid and cerebrospinal fluid). The change observed for the neurometallome likely has consequences for the potential to rescue infarcted tissue, but also presents specific targets for treatment.

Biochemistry & Molecular Biology↗

Evaluating a Semi-Quantitative, Spectrophotometric Method for the Rapid Determination of Total Rare Earth Element Concentrations in Citrate Leaching Solutions

Quick, reliable methods to measure the rare earth elements (REEs) in process streams are needed to support real-time parameterization and monitoring for a burgeoning number of REE extraction schemes. Such methods would ideally be fast, reproducible, and field-deployable. This study evaluates the feasibility of using a chromogenic indicator, arsenazo(III) (hereafter abbreviated as Arsz(III)) to detect the concentration of REEs in complex citrate leaching solutions using a spectrophotometer. Arsz(III) forms a chromogenic complex with the lanthanide elements that produces a blue/purple color detectable in the visible light range. Matrices of solutions containing varied concentrations of calcium, iron, and lanthanum were scanned in the presence of an Arsz(III) indicator to generate a modeled relationship that could be used to back calculate REE concentrations. While relatively quick (scan times on the order of seconds), the results indicated that the calcium and iron concentrations of typical mining solutions overwhelm the signal of the REEs, to the extent that sensitivity of the method is no less than 50 µM REEs. These results demonstrate the difficulties of accurately measuring trace metals in complex solutions, although the method may still hold utility for processes with significantly lower calcium and iron concentrations or REE concentrations much greater than 50 µM.

36 MATERIALS SCIENCE↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Molecular and Higher Precision Isotopic Measurements of the Mars Atmosphere and Subsurface Volatiles

In response to the question 'what to do next' at Mars we explore the value of a high precision in situ measurement of isotopic and trace gas constituents in the atmosphere combined with a similar analysis of gas extracted from near surface rocks and soils. The scientific goals are to advance our understanding of the evolution of the Martian atmosphere and to search for fossils of past geochemical conditions. One element of this program that ties directly to the goals of the Astrobiology Program will be a sensitive search for simple or complex organic molecules contained in the atmosphere and in the solid phase. The broad chemical and isotopic analysis planned insures that a highly successful program will be carried out even if no organics are detected. We will demonstrate that the technology to carry out this Program is presently in hand.

Mahaffy, P. R.↗

Microscale Thermophoresis (MST) as a Tool to Study Binding Interactions of Oxygen-Sensitive Biohybrids

Microscale thermophoresis (MST) is a technique used to measure the strength of molecular interactions. MST is a thermophoretic-based technique that monitors the change in fluorescence associated with the movement of fluorescent-labeled molecules in response to a temperature gradient triggered by an IR LASER. MST has advantages over other approaches for examining molecular interactions, such as isothermal titration calorimetry, nuclear magnetic resonance, biolayer interferometry, and surface plasmon resonance, requiring a small sample size that does not need to be immobilized and a high-sensitivity fluorescence detection. In addition, since the approach involves the loading of samples into capillaries that can be easily sealed, it can be adapted to analyze oxygen-sensitive samples. In this Bio-protocol, we describe the troubleshooting and optimization we have done to enable the use of MST to examine protein–protein interactions, protein–ligand interactions, and protein–nanocrystal interactions. The salient elements in the developed procedures include 1) loading and sealing capabilities in an anaerobic chamber for analysis using a NanoTemper MST located on the benchtop in air, 2) identification of the optimal reducing agents compatible with data acquisition with effective protection against trace oxygen, and 3) the optimization of data acquisition and analysis procedures. The procedures lay the groundwork to define the determinants of molecular interactions in these technically demanding systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Luminescent Materials and Instrumentation for Critical Mineral Discovery and Monitoring

Presentation discussing career paths in chemistry as well as how chemical research is applied to address real-world problems. Here, a variety of different materials (metal-organic frameworks, carbon dots, thin films, etc.) are used as luminescent sensors to detect trace quantities of economically critical metals, which are used in applications ranging from renewable energy to national defense. In an application particularly relevant to Western Pennsylvania, the sensor technologies are deployed in coal utilization byproducts including fly ash leachates and acid mine drainage. Taken together, this research presents an exciting path towards reducing the characterization costs associated with metals prospecting and process monitoring, facilitating domestic production of these metals.

analytical chemistry↗

Conductivity of a Copper-Carbon Covetic Composite

NASA is currently engaged in the development of highly electrically conductive wire for space and aviation power and propulsion applications. Higher levels of electrical conductivity and lower densities compared to copper and aluminum are needed to improve the efficiency of commercial aviation and space flight. Carbon, in various forms, is being considered as a component in composites to increase conductivity and decrease density in Cu and Al. One form of carbon that is currently receiving much interest is known as covectic. The technology currently known as covetics was first introduced by Shugart and Scherer whose patents claimed "Carbon can be incorporated into any of these metals by melting the metal, mixing the carbon into the molten metal and, while mixing, applying a current of sufficient amperage to the molten mixture such that the carbon becomes incorporated into the metal, thereby forming a single phase metal-carbon material." It is reported that in this process a conversion reaction occurs with the carbon forming covalent bonds with the host metal, and that covetic processing enables higher carbon solubility and improvements in properties. Although there is a growing body of work supporting covetic materials, it is still a very new and somewhat controversial field. Composition, density, and electrical conductivity measurements of a covetically processed alloy ingot of Cu and C, with a nominal composition of Cu-0.4wt.% C, were made. A pure Cu ingot was similarly processed for comparison. Sections of these ingots were worked into wire and tested. Only small amounts of C could be detected in the Cu-0.4wt.% C ingot, and trace amounts (0.006 wt.%) in the wire. All wires had densities very close to the full density of pure Cu, indicating a high level of Cu purity and low void fraction. Finally, the electrical conductivity of the Cu-0.4wt.% C wires were 9% lower than the samples similarly processed but without C additions. The wires made without C additions had conductivities approximately equal to pure Cu. The low conductivity of the Cu-0.4wt.% C material is believed to be due to: (1) a structure of interfaces in the wire created by collapsed voids lined with elemental C, (2) impurities, such as Fe in the Cu, which came from the added C, and (3) a small volume fraction of voids.

Degroh, Henry C.↗

Measurement of tropospheric OH by laser long-path absorption spectroscopy

OH-radicals are measured by laser long-path absorption spectroscopy. A tunable Nd:YAG/dye laser system provides broadbanded light at 308 nm. The beam is expanded to 0.3 m and pointed to an array of retroreflectors placed at a distance of 2800 m. The returning beam is separated from the outgoing beam and focused into a spectrometer of 0.3 pm resolution. A 1024 element diode array is used as a detector. The signal is digitized by a 14 bit analog to digital converter. The ultimate aim is a detection limit of 10(exp 5) molecules cm(exp -3) of OH. However the measurements in 1991 allowed only the recognition of OH absorptions corresponding to 3 x 10(exp 6) OH cm(exp -3) with a signal to noise ratio of two. Improvements of the instrument are under way. The advantages of the DOAS method are: the accuracy of detection is guaranteed because loss of OH radicals within the device is avoided, the rate of OH production by the device is negligible, and absorptions of other trace gases could be corrected for; and the calibration procedure for the device is fast and easy. The disadvantages of the system are: time resolution is about minutes because about ten spectra had to be added to keep the noise level down, the OH concentration is averaged along the whole light path, weight (500 kg) and size (4x4 m) of the device; and approximately 10 l/min of coolant and supply of 8 kW electrical power are necessary.

Kraft, Michael↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗