Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: Initial test with elemental Hg

A portable optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode plasma spectrometer is described. A compact, low-power, atmospheric argon microwave plasma torch (MPT) is utilized as the emission source when the spectrometer is operating in the OES mode. The same MPT serves as the atomization source for ringdown measurements in the CRDS mode. Initial demonstration of the instrument is carried out by observing OES of multiple elements including mercury (Hg) in the OES mode and by measuring absolute concentrations of Hg in the metastable state 6s6p {sup 3}P{sub 0} in the CRDS mode, in which a palm-size diode laser operating at a single wavelength 405 nm is incorporated in the spectrometer as the light source. In the OES mode, the detection limit for Hg is determined to be 44 parts per 10{sup 9} (ppb). A strong radiation trapping effect on emission measurements of Hg at 254 nm is observed when the Hg solution concentration is higher than 50 parts per 10{sup 6} (ppm). The radiation trapping effect suggests that two different transition lines of Hg at 253.65 nm and 365.01 nm be selected for emission measurements in lower (<50 ppm) and higher concentration ranges (>50 ppm), respectively. In the CRDS mode, the detection limit of Hg in the metastable state 6s6p {sup 3}P{sub 0} is achieved to be 2.24 parts per 10{sup 12} (ppt) when the plasma is operating at 150 W with sample gas flow rate of 480 mL min{sup -1}; the detection limit corresponds to 50 ppm in Hg sample solution. Advantage of this novel spectrometer has two-fold, it has a large measurement dynamic range, from a few ppt to hundreds ppm and the CRDS mode can serve as calibration for the OES mode as well as high sensitivity measurements. Measurements of seven other elements, As, Cd, Mn, Ni, P, Pb, and Sr, using the OES mode are also carried out with detection limits of 1100, 33, 30, 144, 576, 94, and 2 ppb, respectively. Matrix effect in the presence of other elements on Hg measurements has been found to increase the detection limit to 131 ppb. These elements in lower concentrations can also be measured in the CRDS mode when a compact laser source is available to be integrated into the spectrometer in the future. This exploratory study demonstrates a new instrument platform using an OES-CRDS dual-mode technique for potential field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗

Experimental results of the QUENCH-16 bundle test on air ingress

The out-of-pile bundle experiment QUENCH-16 on air ingress was conducted in the electrically heated 21-rod QUENCH facility at KIT in July 2011. It was performed in the frame of the EC supported LACOMECO program. The test scenario included the oxidation of the Zircaloy-4 claddings in air following a limited pre-oxidation in steam, and involved a long period of oxygen starvation to promote interaction with the nitrogen. The primary aim was to examine the influence of the formed oxide layer structure on bundle coolability and hydrogen release during the terminal flooding phase. QUENCH-16 was thus a companion test to the earlier air ingress experiment, QUENCH-10, which was performed with strongly pre-oxidized bundle. Unlike QUENCH-10, significant temperature escalation and intensive hydrogen release were observed during the reflood phase. Post-test investigations of bundle cross sections reveal residual nitride traces at various elevations. The external part of the oxide scale is of porous structure due to re-oxidation of nitrides during reflood. Relative thick internal oxide scales underneath this porous layer and residual nitrides were formed during reflood. At lower bundle elevations frozen partially oxidized melt was detected, relocated from upper elevations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiological Monitoring of Waste Treatment Plant

Scheduled waste in West Malaysia is handled by Concession Company and is stored and then is incinerated. It is known that incineration process may result in naturally occurring radioactive materials (NORM) to be concentrated. In this study we have measured three samples consist of by-product from the operation process such as slag, filter cake and fly ash. Other various environmental media such as air, surface water, groundwater and soil within and around the plant have also been analysed for their radioactivity levels. The concentration of Ra-226, Ac-228 and K-40 in slag are 0.062 Bq/g, 0.016 Bq/g and 0.19 Bq/g respectively. The total activity (Ra{sub eq}) in slag is 99.5 Bq/kg. The concentration in fly ash is 0.032 Bq/g, 0.16 Bq/g and 0.34 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 287.0 Bq/kg. For filter cake, the concentration is 0.13 Bq/g, 0.031 Bq/g and 0.33 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 199.7 Bq/kg. The external radiation level ranges from 0.08 {mu}Sv/h (Administrative building) to 0.35 {mu}Sv/h (TENORM storage area). The concentration level of radon and thoron progeny varies from 0.0001 to 0.0016 WL and 0.0006 WL to 0.002 WL respectively. For soil samples, the activity ranges from 0.11 Bq/g to 0.29 Bq/g, 0.06 Bq/g to 0.18 Bq/g and 0.065 Bq/g to 0.38 Bq/g for Ra-226, Ac-228 and K-40 respectively. While activity in water, except for a trace of K-40, it is non-detectable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology

Abstract The brain is a privileged organ with regard to its trace element composition and maintains a robust barrier system to sequester this specialized environment from the rest of the body and the vascular system. Stroke is caused by loss of adequate blood flow to a region of the brain. Without adequate blood flow ischaemic changes begin almost immediately, triggering an ischaemic cascade, characterized by ion dysregulation, loss of function, oxidative damage, cellular degradation, and breakdown of the barrier that helps maintain this environment. Ion dysregulation is a hallmark of stroke pathophysiology and we observe that most elements in the brain are dysregulated after stroke. X-ray fluorescence-based detection of physiological changes in the neurometallome after stroke reveals profound ion dysregulation within the lesion and surrounding tissue. Not only are most elements significantly dysregulated after stroke, but the level of dysregulation cannot be predicted from a cell-level description of dysregulation. X-ray fluorescence imaging reveals that the stroke lesion retains <25% of essential K+ after stroke, but this element is not concomitantly elevated elsewhere in the organ. Moreover, elements like Na+, Ca2+, and Cl− are vastly elevated above levels available in normal brain tissue (>400%, >200%, and >150%, respectively). We hypothesize that weakening of the blood–brain barrier after stroke allows elements to freely diffuse down their concentration gradient so that the stroke lesion is in equilibrium with blood (and the compartments containing brain interstitial fluid and cerebrospinal fluid). The change observed for the neurometallome likely has consequences for the potential to rescue infarcted tissue, but also presents specific targets for treatment.

Biochemistry & Molecular Biology↗

Evaluating a Semi-Quantitative, Spectrophotometric Method for the Rapid Determination of Total Rare Earth Element Concentrations in Citrate Leaching Solutions

Quick, reliable methods to measure the rare earth elements (REEs) in process streams are needed to support real-time parameterization and monitoring for a burgeoning number of REE extraction schemes. Such methods would ideally be fast, reproducible, and field-deployable. This study evaluates the feasibility of using a chromogenic indicator, arsenazo(III) (hereafter abbreviated as Arsz(III)) to detect the concentration of REEs in complex citrate leaching solutions using a spectrophotometer. Arsz(III) forms a chromogenic complex with the lanthanide elements that produces a blue/purple color detectable in the visible light range. Matrices of solutions containing varied concentrations of calcium, iron, and lanthanum were scanned in the presence of an Arsz(III) indicator to generate a modeled relationship that could be used to back calculate REE concentrations. While relatively quick (scan times on the order of seconds), the results indicated that the calcium and iron concentrations of typical mining solutions overwhelm the signal of the REEs, to the extent that sensitivity of the method is no less than 50 µM REEs. These results demonstrate the difficulties of accurately measuring trace metals in complex solutions, although the method may still hold utility for processes with significantly lower calcium and iron concentrations or REE concentrations much greater than 50 µM.

36 MATERIALS SCIENCE↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

COSMIC ORIGINS SPECTROGRAPH OBSERVATIONS OF WARM INTERVENING GAS AT z {approx} 0.325 TOWARD 3C 263

We present HST/COS high-S/N observations of the z = 0.32566 multiphase absorber toward 3C 263. The Cosmic Origins Spectrograph (COS) data show absorption from H I (Ly{alpha} to Ly{theta}), O VI, C III, N III, Si III, and C II. The Ne VIII in this absorber is detected in the FUSE spectrum along with O III, O IV, and N IV. The low and intermediate ions are kinematically aligned with each other and H I and display narrow line widths of b {approx} 6-8 km s{sup -1}. The O VI {lambda}{lambda}1031, 1037 lines are kinematically offset by {Delta}v {approx} 12 km s{sup -1} from the low ions and are a factor of {approx}4 broader. All metal ions except O VI and Ne VIII are consistent with an origin in gas photoionized by the extragalactic background radiation. The bulk of the observed H I is also traced by this photoionized medium. The metallicity in this gas phase is Z {approx}> 0.15 Z{sub Sun} with carbon having near-solar abundances. The O VI and Ne VIII favor an origin in collisionally ionized gas at T = 5.2 Multiplication-Sign 10{sup 5} K. The H I absorption associated with this warm absorber is a broad-Ly{alpha} absorber (BLA) marginally detected in the COS spectrum. This warm gas phase has a metallicity of [X/H] {approx}-0.12 dex, and a total hydrogen column density of N( H) {approx} 3 Multiplication-Sign 10{sup 19} cm{sup -2}, which is {approx}2 dex higher than what is traced by the photoionized gas. Simultaneous detection of O VI, Ne VIII, and BLAs in an absorber can be a strong diagnostic of gas with T {approx} 10{sup 5}-10{sup 6} K corresponding to the warm phase of the warm-hot intergalactic medium or shock-heated gas in the extended halos of galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

National Security Science and Technology Initiative: Air Cargo Screening

The non-intrusive inspection (NII) of consolidated air cargo carried on commercial passenger aircraft continues to be a technically challenging, high-priority requirement of the Department of Homeland Security's Science and Technology Directorate (DHS S&T), the Transportation Security Agency and the Federal Aviation Administration. The goal of deploying a screening system that can reliably and cost-effectively detect explosive threats in consolidated cargo without adversely affecting the flow of commerce will require significant technical advances that will take years to develop. To address this critical National Security need, the Battelle Memorial Institute (Battelle), under a Cooperative Research and Development Agreement (CRADA) with four of its associated US Department of Energy (DOE) National Laboratories (Oak Ridge, Pacific Northwest, Idaho, and Brookhaven), conducted a research and development initiative focused on identifying, evaluating, and integrating technologies for screening consolidated air cargo for the presence of explosive threats. Battelle invested $8.5M of internal research and development funds during fiscal years 2007 through 2009. The primary results of this effort are described in this document and can be summarized as follows: (1) Completed a gap analysis that identified threat signatures and observables, candidate technologies for detection, their current state of development, and provided recommendations for improvements to meet air cargo screening requirements. (2) Defined a Commodity/Threat/Detection matrix that focuses modeling and experimental efforts, identifies technology gaps and game-changing opportunities, and provides a means of summarizing current and emerging capabilities. (3) Defined key properties (e.g., elemental composition, average density, effective atomic weight) for basic commodity and explosive benchmarks, developed virtual models of the physical distributions (pallets) of three commodity types and three explosive benchmarks combinations, and conducted modeling and simulation studies to begin populating the matrix of commodities, threats, and detection technologies. (4) Designed and fabricated basic (homogeneous) commodity test pallets and fabricated inert stimulants to support experiments and to validate modeling/simulation results. (5) Developed/expanded the team's capabilities to conduct full-scale imaging (neutron and x-ray) experiments of air cargo commodities and explosive benchmarks. (6) Conducted experiments to improve the collection of trace particles of explosives from a variety of surfaces representative of air cargo materials by means of mechanical (air/vibration/pressure), thermal, and electrostatic methods. Air cargo screening is a difficult challenge that will require significant investment in both research and development to find a suitable solution to ensure the safety of passengers without significantly hindering the flow of commodities. The initiative funded by Battelle has positioned this group to make major contributions in meeting the air cargo challenge by developing collaborations, developing laboratory test systems, improving knowledge of the challenges (both technical and business) for air cargo screening, and increasing the understanding of the capabilities for current inspection methods (x-ray radiography, x-ray backscatter, etc.) and potential future inspection methods (neutron radiography, fusion of detector modalities, advanced trace detection, etc.). Lastly, air cargo screening is still an issue that will benefit from collaboration between Department of Energy Laboratories and Battelle. On January 7, 2010, DHS Secretary Napolitano joined White House Press Secretary Robert Gibbs and Assistant to the President for Counterterrorism and Homeland Security John Brennan to announce several recommendations DHS has made to the President for improving the technology and procedures used to protect air travel from acts of terrorism. (This announcement followed the 25 Dec'09 Delta/Northwest Airlines Flight 253 terror attack.) Secretary Napolitano outlined five recommendations DHS will pursue to enhance the safety of the traveling public. One of the five recommendations, read as follows: 'Establish a partnership on aviation security between DHS and the Department of Energy and its National Laboratories in order to develop new and more effective technologies to deter and disrupt known threats and proactively anticipate and protect against new ways by which terrorists could seek to board an aircraft.' In conclusion, it appears very timely that Battelle and its DOE lab partners initiated a serious collaboration on the air cargo topic, and that we should continue to work toward future collaboration in response to the government's needs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Field-deployable, nano-sensing approach for real-time detection of free mercury, speciation and quantification in surface stream waters and groundwater samples at the U.S. Department of Energy contaminated sites

The detrimental effects on human health caused by long-term exposure to trace contamination of toxic metals have been documented in numerous epidemiological and toxicological studies. The fact that metals are non-biodegradable and accumulate in the food chain poses a severe threat to the environment and human health. Their monitoring in drinking water, aquatic ecosystems, food and biological fluids samples is then essential for global sustainability. While research efforts employing established methodology continue to advance conceptual/computational models of contaminant behavior, the increasing awareness and public concern with environmental and occupational exposure to toxic metals calls for sensing devices capable to handle on-site elemental analysis in short analysis time. Field analysis with potable methodology prevents unnecessary scrutiny of un-contaminated samples via laboratory-bound methods, reduces analysis cost and expedites turnaround time for decision making and remediation purposes. Of particular toxicological interest are mercury and its species. Mercury is recognized as a major environmental pollution issue. The field-portable sensor developed in this project provides a unique and valuable tool for the on-site, real-time determination of inorganic mercury in surface waters. The ability to perform on-site analysis of mercury should prove useful in remote locations with difficult accessibility. It should facilitate data collection from statistically meaningful population sizes for a better understanding of the dose-effect role and the water-soil-plant-animal-human transfer mechanisms. The acquired knowledge should benefit the development of efficient environmental remediation processes, which is extremely relevant for a globally sustainable environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.

Pavlish, John↗

Microscale Thermophoresis (MST) as a Tool to Study Binding Interactions of Oxygen-Sensitive Biohybrids

Microscale thermophoresis (MST) is a technique used to measure the strength of molecular interactions. MST is a thermophoretic-based technique that monitors the change in fluorescence associated with the movement of fluorescent-labeled molecules in response to a temperature gradient triggered by an IR LASER. MST has advantages over other approaches for examining molecular interactions, such as isothermal titration calorimetry, nuclear magnetic resonance, biolayer interferometry, and surface plasmon resonance, requiring a small sample size that does not need to be immobilized and a high-sensitivity fluorescence detection. In addition, since the approach involves the loading of samples into capillaries that can be easily sealed, it can be adapted to analyze oxygen-sensitive samples. In this Bio-protocol, we describe the troubleshooting and optimization we have done to enable the use of MST to examine protein–protein interactions, protein–ligand interactions, and protein–nanocrystal interactions. The salient elements in the developed procedures include 1) loading and sealing capabilities in an anaerobic chamber for analysis using a NanoTemper MST located on the benchtop in air, 2) identification of the optimal reducing agents compatible with data acquisition with effective protection against trace oxygen, and 3) the optimization of data acquisition and analysis procedures. The procedures lay the groundwork to define the determinants of molecular interactions in these technically demanding systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Luminescent Materials and Instrumentation for Critical Mineral Discovery and Monitoring

Presentation discussing career paths in chemistry as well as how chemical research is applied to address real-world problems. Here, a variety of different materials (metal-organic frameworks, carbon dots, thin films, etc.) are used as luminescent sensors to detect trace quantities of economically critical metals, which are used in applications ranging from renewable energy to national defense. In an application particularly relevant to Western Pennsylvania, the sensor technologies are deployed in coal utilization byproducts including fly ash leachates and acid mine drainage. Taken together, this research presents an exciting path towards reducing the characterization costs associated with metals prospecting and process monitoring, facilitating domestic production of these metals.

analytical chemistry↗

The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: {phi}{sub scd} = 1.10{sup 6} n/cm{sup 2}/s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OBSERVATIONS OF Mg II ABSORPTION NEAR z {approx} 1 GALAXIES SELECTED FROM THE DEEP2 REDSHIFT SURVEY

We study the frequency of Mg II absorption in the outer halos of galaxies at z = 0.6-1.4 (with median z = 0.87), using new spectra obtained of 10 background quasars with galaxy impact parameters of b < 100 kpc. The quasar sight lines were selected from the Sloan Digital Sky Survey DR6 QSO catalog based on proximity to galaxies in the DEEP2 redshift survey. In addition to the 10 small impact systems, we examine 40 additional galaxies at 100 kpc < b < 500 kpc serendipitously located in the same fields. We detect Mg II absorbers with equivalent width W{sub r} = 0.15-1.0 A, though not all absorbers correlate with DEEP galaxies. We find five unique absorbers within {Delta}v = 500 km s{sup -1} and b < 100 kpc of a DEEP galaxy; this small sample contains both early- and late-type galaxies and has no obvious trends with star formation rate. No Mg II is detected more than 100 kpc from galaxies; inside this radius the covering fraction scales with impact parameter and galaxy luminosity in a very similar fashion to samples studied at lower redshift. In all but one case, when Mg II is detected without a spectroscopically confirmed galaxy, there exists a plausible photometric candidate which was excluded because of slit collision or apparent magnitude. We do not detect any strong absorbers with W{sub r} > 1.0 A, consistent with other samples of galaxy-selected Mg II systems. We speculate that Mg II systems with 0.3 < W{sub r} < 1.0 trace old relic material from galactic outflows and/or the halo assembly process, and that in contrast, systems with large W{sub r} are more likely to reflect the more recent star-forming history of their associated galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗