Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermal Radiation Effects Analyzed in Translucent Composite and Thermal Barrier Coating

Ceramic parts and coatings are needed to withstand high temperatures in advanced aircraft engines. In hot environments, such as in the combustion chambers of these engines, infrared and visible radiation can penetrate into some ceramics and heat them internally. The internal temperatures depend on radiative effects combined with heat conduction, and on convection and radiation at the material boundaries. Since engine temperatures are high, radiant emission can be large from within translucent parts and coatings, and this must be included in the analysis. Transient and steady-state behavior are both important. During a transient, radiant penetration provides more rapid internal heating than conduction alone, and the temperature distributions are usually considerably different than for steady-state conditions; this can produce transient thermal stresses. Analytical and numerical methods are being used at the NASA Lewis Research Center to predict transient temperatures and heat flows in translucent materials. A transient analysis was done for a composite of two translucent layers. The layer refractive indices were larger than 1, producing internal reflections at the boundaries and at the internal interface. In addition, steady-state results were computed for a two-layer composite with one layer opaque. The results were used to assess the importance of internal radiation in a zirconia thermal barrier coating on a cooled metal wall. Since the radiative transfer equations are rather complex, especially when internal scattering is included, approximate methods are being investigated that might be convenient for computer design programs. An approximate two-flux method was used and verified by comparisons with solutions that used exact radiative transfer relations. The two-flux equations include scattering without increasing solution difficulty.

Siegel, Robert↗

Flight motor set 360L001 (STS-26R). (Reconstructed dynamic loads analysis)

A transient analysis was performed to correlate the predicted versus measured behavior of the Redesigned Solid Rocket Booster (RSRB) during Flight 360L001 (STS-26R) liftoff. Approximately 9 accelerometers, 152 strain gages, and 104 girth gages were bonded to the motors during this event. Prior to Flight 360L001, a finite element model of the RSRB was analyzed to predict the accelerations, strains, and displacements measured by this developmental flight instrumentation (DFI) within an order of magnitude. Subsequently, an analysis has been performed which uses actual Flight 360L001 liftoff loading conditions, and makes more precise predictions for the RSRB structural behavior. Essential information describing the analytical model, analytical techniques used, correlation of the predicted versus measured RSRB behavior, and conclusions, are presented. A detailed model of the RSRB was developed and correlated for use in analyzing the motor behavior during liftoff loading conditions. This finite element model, referred to as the RSRB global model, uses super-element techniques to model all components of the RSRB. The objective of the RSRB global model is to accurately predict deflections and gap openings in the field joints to an accuracy of approximately 0.001 inch. The model of the field joint component was correlated to Referee and Joint Environment Simulation (JES) tests. The accuracy of the assembled RSRB global model was validated by correlation to static-fire tests such DM-8, DM-9, QM-7, and QM-8. This validated RSRB global model was used to predict RSRB structural behavior and joint gap opening during Flight 360L001 liftoff. The results of a transient analysis of the RSRB global model with imposed liftoff loading conditions are presented. Rockwell used many gage measurements to reconstruct the load parameters which were imposed on the RSRB during the Flight 360L001 liftoff. Each load parameter, and its application, is described. Also presented are conclusions and recommendations based on the analysis of this load case and the resulting correlation between predicted and measured RSRB structural behavior.

Call, V. B.↗

Benchmarking Of Improved DPAC Transient Deflagration Analysis Code

The transient deflagration code DPAC (Deflagration Pressure Analysis Code) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak deflagration pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vessel walls. In addition, DPAC has been coupled with CEA, a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. The improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient multidimensional analysis of nonconventional heat pipes with uniform and nonuniform heat distributions

A numerical analysis of transient heat pipe performance including nonconventional heat pipes with nonuniform heat distributions is presented. A body-fitted grid system was applied to a three-dimensional wall and wick model, which was coupled with a transient compressible quasi-one-dimensional vapor flow model. The numerical results were first compared with experimental data from cylindrical heat pipes with good agreement. Numerical calculations were then made for a leading edge heat pipe with localized high heat fluxes. Performance characteristics different from conventional heat pipes are illustrated and some operating limits concerning heat pipe design are discussed.

Cao, Y.↗

Transient loads analysis for space flight applications

A significant part of the flight readiness verification process involves transient analysis of the coupled Shuttle-payload system to determine the low frequency transient loads. This paper describes a methodology for transient loads analysis and its implementation for the Spacelab Life Sciences Mission. The analysis is carried out using two major software tools - NASTRAN and an external FORTRAN code called EZTRAN. This approach is adopted to overcome some of the limitations of NASTRAN's standard transient analysis capabilities. The method uses Data Recovery Matrices (DRM) to improve computational efficiency. The mode acceleration method is fully implemented in the DRM formulation to recover accurate displacements, stresses, and forces. The advantages of the method are demonstrated through a numerical example.

Thampi, S. K.↗

Recovered transient load analysis for payload structural systems

A recovered transient analysis technique is proposed wherein the results of a previous launch vehicle/payload system can be used to obtain the information on a new payload structure to be launched by an identical launch vehicle. The advantage of the proposed method is that the complete analysis can be performed within the payload organization with the same accuracy as that of a full scale, multiorganizational loads analysis. Also, the flight measured interface accelerations can be used as the forcing functions for more realistic representations of the dynamic environments.

Chen, J. C.↗

An ODE-Enabled Distributed Transient Stability Analysis for Networked Microgrids

Networked microgrid (NMG) exhibits noteworthy resiliency and flexibility benefits for the mutual support from neighboring microgrids. With high penetration of distributed energy resources (DERs) and the associated controls, the transient stability analysis of NMGs is of critical significance. To address the issues of computation burdens and privacy in the centralized transient analysis, this paper devises an ordinary differential equation (ODE)-enabled distributed transient stability (DTS) methodology for NMGs. First, an ODE-based microgrid model is established to capture the dynamics in the droop control of DERs as well as network and load. Further, a distributed DTS is devised for the ODE representation of an NMG, allowing a privacy-preserving transient analysis of each microgrid while accurately reconstructing the frequency dynamics under droop controls in all DERs. In conclusion, extensive tests are performed to verify the validity of the ODE-based microgrid model through both dynamic response and eigenvalue analysis, and the efficacy of the DTS algorithm in simulating the large signal responses and the frequent fluctuations in NMG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transient Safety Analysis of Fast Spectrum TRU Burning LWRs with Internal Blankets

The objective of this proposal was to perform a detailed transient safety analysis of the Resource-Renewable BWR (RBWR) core designs using the U.S. NRC TRACE/PARCS code system. This project involved the same joint team that has performed the RBWR design evaluation for EPRI and therefore be able to leverage that previous work. And because of their extensive experience with fast spectrum reactors and parfait core designs, ANL was also part the project team. The principal outcome of this project was the development of a state-of-the-art transient analysis capability for GEN-IV reactors based on Monte Carlo generated cross sections and the US NRC coupled code system TRACE/PARCS, and a state-of-the-art coupled code assessment of the transient safety performance of the RBWR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.↗

Transient thermal analysis of a titanium multiwall thermal protection system

The application of the SPAR thermal analyzer to the thermal analysis of a thermal protection system concept is discussed. The titanium multiwall thermal protection system concept consists of alternate flat and dimpled sheets which are joined together at the crests of the dimples and formed into 30 cm by 30 cm (12 in. by 12 in.) tiles. The tiles are mechanically attached to the structure. The complex tile geometry complicates thermal analysis. Three modes of heat transfer were considered: conduction through the gas inside the tile, conduction through the metal, and radiation between the various layers. The voids between the dimpled and flat sheets were designed to be small enough so that natural convection is insignificant (e.g., Grashof number 1000). A two step approach was used in the thermal analysis of the multiwall thermal protection system. First, an effective normal (through-the-thickness) thermal conductivity was obtained from a steady state analysis using a detailed SPAR finite element model of a small symmetric section of the multiwall tile. This effective conductivity was then used in simple one dimensional finite element models for preliminary analysis of several transient heat transfer problems.

Blosser, M. L.↗

Transient thermal analysis of fluid systems

Computer program performs transient thermal analysis of any 2-node to 200-node-thermal network, which transports heat by fluid flow convection. Program can be modified to add conduction along tubes and radiation.

Chandler, G. D.↗

A hybrid transfinite element approach for nonlinear transient thermal analysis

A new computational approach for transient nonlinear thermal analysis of structures is proposed. It is a hybrid approach which combines the modeling versatility of contemporary finite elements in conjunction with transform methods and classical Bubnov-Galerkin schemes. The present study is limited to nonlinearities due to temperature-dependent thermophysical properties. Numerical test cases attest to the basic capabilities and therein validate the transfinite element approach by means of comparisons with conventional finite element schemes and/or available solutions.

Tamma, Kumar K.↗

Concurrent algorithms for transient FE analysis

Information on concurrent algorithms for transient finite element analysis is given in viewgraph form. Information is given on concurrent dynamic algorithms, interprocessor communication, the performance of the BAR problem on the 32 Processor Hypercube, computational efficiency and accuracy analysis.

Ortiz, M.↗