Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cement sensors with acoustic bandgaps using carbon nanotubes

Cement is widely used in wellbores to stabilize the steel casing used in wellbore operations for oil and gas production, enhanced geothermal systems and carbon sequestration, and to limit fluid movement between sub-surface strata. Flaws such as microcracks in wellbore cement can lead to leakage along the wellbore compromising wellbore integrity. There is an increasing need for methods to monitor cement crack propagation in wellbore environments. In this study, we develop and report the first cementitious sensors capable of exhibiting high frequency acoustic bandgaps (ABGs) using carbon nanotubes (CNTs). Computational simulations of a sensor unit cell are used to design cement-multi walled carbon nanotubes (MWCNTs) sensors that show a wide bandgap. When the cement-MWCNTs sensors is embedded in cement specimens, bandgaps were measured experimentally under 300 kHz and under 600 kHz, consistent with the computationally predicted bandgaps in the range of 290–360 kHz, 410–460 kHz and 515–585 kHz. These bandgap features were absent in homogeneous cement specimens. X-ray tomographic reconstructions showed microscopic debonding at cement-MWCNTs sensor interface. Frequency response analysis of a three-dimensional computational model indicated a shift of frequency of minimum transmission due to the interface debonding, but no perturbation of bandgap response was observed. Here, the cement-MWCNTs sensors developed in this study show the potential of a packed CNT inclusion material in cementitious matrix to create ABGs in a cement matrix.

36 MATERIALS SCIENCE↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in g4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages of this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Abrasion-fission reactions at intermediate energies

The availability of high-intensity, heavy-ion beams coupled to sensitive, large solid-angle acceptance spectrometers has enabled a detailed examination of the fission fragments produced in induced-fission reactions. The abrasion fission process involves the formation of projectile-like prefragments in violent nuclear collisions at relative energies in excess of 100 MeV/u. At intermediate energies below this threshold, experiments suggest a change in the prefragment kinematic qualities. Information regarding the influence of this transitional phase upon the evolution of nuclei approaching the point of scission is scarce. In this article, data are presented for over 200 nuclei from nickel to palladium produced in abrasion-fission reactions of a 80 MeV/u 238 U beam. Cross sections were obtained following yield measurements performed for the principal charge states of the identified fission fragments and a detailed analysis of the ion transmission. A full kinematic analysis of the fission fragments has been performed using the LISE ++ software package, where the trajectory of an ion passing through a spectrometer can be reconstructed based upon measurements at the focal plane. Furthermore, the results obtained at the S800 spectrograph are compared with predictions obtained with a three-fission progenitor (3EER) model. Systematic studies of fission-fragment properties continue to provide a valuable experimental benchmark for theoretical efforts directed toward describing this complex decay channel, that is important in the context of planning experiments to explore the neutron-rich region of the nuclear chart at rare-isotope beam facilities.

59 ≤ A ≤ 8990 ≤ A ≤ 149↗

Machine‐Learning‐Driven Exploration of Surface Reconstructions of Reduced Rutile TiO 2

Abstract Titanium dioxide (TiO 2 ) is widely used as a catalyst support due to its stability, tunable electronic properties, and surface oxygen vacancies, which are crucial for catalytic processes such as the reverse water‐gas shift (RWGS) reaction. Reduced TiO 2 surfaces undergo complex surface reconstructions that endow unique properties but are computationally challenging to describe. In this study, we utilize machine‐learning interatomic potentials (MLIPs) integrated with an active‐learning workflow to efficiently explore reduced rutile TiO 2 surfaces. This approach enabled the prediction of a phase diagram as a function of oxygen chemical potential, revealing a variety of reconstructed phases, including a previously unreported subsurface shear plane structure. We further investigate the electronic properties of these surfaces and validate our results by comparing experimental and theoretical high‐resolution transmission electron microscopy (HRTEM). Our findings provide new insights into how extreme surface reductions influence the structural and electronic properties of TiO 2 , with potential implications for catalyst design.

Lee, Yonghyuk [Chemistry and Biochemistry Universi↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

Tomographic FLEET with a wedge array for multi-point three-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) velocimetry is an important diagnostic technique for seedless velocimetry measurements particularly in supersonic and hypersonic flows. Typical FLEET measurements feature a single laser line and camera system to achieve one-component velocimetry along a line, although some multiple-spot and multiple-component configurations have been demonstrated. In this work, tomographic imaging is used to track the three-dimensional location of many FLEET spots. A quadscope is used to combine four unique views onto a single high-speed image intensifier and camera. Tomographic reconstructions of the FLEET emission are analyzed for three-component velocimetry from multiple FLEET spots. Glass wedges are used to create many (nine) closely spaced FLEET spots with less than 10% transmission losses. These developments lead to a significant improvement in the dimensionality and spatial coverage of a FLEET instrument with some increases in experimental complexity and data processing. Multiple-point three-component FLEET velocimetry is demonstrated in an underexpanded jet.

47 OTHER INSTRUMENTATION↗

Super high compression of line drawing data

Models which can be used to accurately represent the type of line drawings which occur in teleconferencing and transmission for remote classrooms and which permit considerable data compression were described. The objective was to encode these pictures in binary sequences of shortest length but such that the pictures can be reconstructed without loss of important structure. It was shown that exploitation of reasonably simple structure permits compressions in the range of 30-100 to 1. When dealing with highly stylized material such as electronic or logic circuit schematics, it is unnecessary to reproduce configurations exactly. Rather, the symbols and configurations must be understood and be reproduced, but one can use fixed font symbols for resistors, diodes, capacitors, etc. Compression of pictures of natural phenomena such as can be realized by taking a similar approach, or essentially zero error reproducibility can be achieved but at a lower level of compression.

Cooper, D. B.↗

Dynamic compressed sensing for real-time tomographic reconstruction

Electron tomography has achieved higher resolution and quality at reduced doses with recent advances in compressed sensing. Compressed sensing (CS) exploits the inherent sparse signal structure to efficiently reconstruct three-dimensional (3D) volumes at the nanoscale from undersampled measurements. However, the process bottlenecks 3D reconstruction with computation times that run from hours to days. Here we demonstrate a framework for dynamic compressed sensing that produces a 3D specimen structure that updates in real-time as new specimen projections are collected. Researchers can begin interpreting 3D specimens as data is collected to facilitate high-throughput and interactive analysis. Using scanning transmission electron microscopy (STEM), we show that dynamic compressed sensing accelerates the convergence speed by ~3-fold while also reducing its error by 27% for a Au/SrTiO 3 nanoparticle specimen. Before a tomography experiment is completed, the 3D tomogram has interpretable structure within ~33% of completion and fine details are visible as early as ~66%. Upon completion of an experiment, a high-fidelity 3D visualization is produced without further delay. Additionally, we report reconstruction parameters that tune data fidelity can be manipulated throughout the computation without re-running the entire process.

47 OTHER INSTRUMENTATION↗

4D Imaging of ZnO-Coated Nanoporous Al 2 O 3 Aerogels by Chemically Sensitive Ptychographic Tomography: Implications for Designer Catalysts

The 3D chemical structure (4D spectromicroscopy) of nanoporous Al 2 O 3 aerogels coated with ZnO by atomic layer deposition (ALD) was studied by multienergy scanning transmission X-ray microscopy. These materials are representative of a class of designer catalysts in which the nanoporous support is prepared separately from the active catalyst material, which is subsequently introduced by ALD, thereby allowing independent optimization of the morphology, chemistry, and spatial distribution of the support and catalyst. The samples studied were prepared by Ga ion and Xe plasma focused ion beam (FIB) milling as well as drop casting from water suspension. Zn L and Al K edge spectra of six samples with three different ZnO loadings were measured to investigate how loading and different sample preparation methods affect the 3D distribution of the ZnO and Al 2 O 3 . Scanning transmission X-ray microscopy (STXM) and ptychographic imaging at two energies each at the Zn L 3 and Al K edge were measured. The ptychography data were analyzed by using the SHARP reconstruction code to generate quantitative 2D chemical maps of the Al 2 O 3 and the ZnO. The STXM and ptychography maps were then measured at a sequence of tilt angles, covering up to 160° of rotation. The 3D structure of the ZnO and Al 2 O 3 was derived from the tilt series data by tomographic reconstruction using a compressed sensing algorithm. A twodimensional spatial resolution (half-period) of 6 nm, measured by Fourier ring correlation, and a 3D spatial resolution (half-period) of 9 nm, measured by Fourier shell correlation, were achieved when using the COSMIC beamline at the Advanced Light Source (ALS). The results show that for all of the ZnO loadings studied there is nonuniform coverage of the ZnO on the Al 2 O 3 aerogel framework. In addition, we found that both FIB methods create sample artifacts, although the distortion was less with Xe plasma than Ga ion FIB.

36 MATERIALS SCIENCE↗

ASGS - An Innovative Approach for Waste Characterization - From the First Study to Experimental Validation - 20260

For disposal of nuclear waste a clear identification of the nuclear inventory is mandatory. Since this waste is usually filled in drums, nuclear specific characterization methods using HPGe detectors usually require the understanding of the limitations of the method assumptions (such as the homogeneity criteria), and often results in applying high uncertainties to the result in waste that is not well known a priori. There are several methods and approaches such as Far-Field, Segmented Gamma Scans (SGS) or Tomographic Gamma Scans (TGS) available. The SGS allows measuring the waste drum in different segments (or 'layers') which allows getting more detailed information about the activity distribution inside a waste drum. In addition, with the transmission source used in tomographic scans, it is possible to also determine the material (and its homogeneity) composition inside a drum. Mirion Technologies developed in cooperation with Aachen Institute for Nuclear Training (AiNT) an innovative measurement approach which allows more accurate results and therefore applying lower uncertainties. This new measurement approach extends the concept of SGS by partitioning the drum into single drum sectors instead of segments. The goal is to perform measurements with high throughput and an accurate analysis based on the reconstruction of activities for each sector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient transfer of images over networks

Effective remote observing requires sending large images over long distances. The usual approach to the transfer problem is to require high bandwidth transmission links, which are expensive to install and operate. An alternative approach is to use existing low-bandwidth connections, such as phone lines or the Internet, in a highly efficient manner by compressing the images. The combined use of existing low-cost infrastructure and standard networking software means that remote observing can be made practical even for small observatories with limited network resources. The authors have implemented such a scheme based on the H-transform compression method developed for astronomical images, which are often resistant to compression because they are noisy. The H-transform can be used for either lossy or lossless compression, and compression factors of at least 10 can be achieved with no noticeable losses in the astrometric or photometric properties of the compressed images. The H-transform allows us to organize the information in an image so that the 'useful' information can be sent first, followed by the noise, which makes up the bulk of the transmission. The receiver can invert a partially received set of H-coefficients, creating an image that improves with time. The H-transform is particularly well-suited to this style of incremental reconstruction, because the spatially localized nature of the basis functions of the H-transorm prevents the appearance of artifacts such as ringing around point sources and edges. The authors' implementation uses the WIYN Telescope Control System's TCP-based communications protocol. An 800x800 16-bit astronomical image was sent over a 2400 baud connection, which would normally take about 71 minutes; after only 60 seconds, the partially received H-transform produced an image that did not differ appreciably from the original. This poster presents a quantification of the efficiencies, as well as examples of images reconstructed from partial data.

Percival, J. W.↗

Structural characterization and gas reactions of small metal particles by high resolution in-situ TEM (Transmission Electron Microscopy) and TED (Transmission Electron Diffraction)

The detection and size analysis of small metal particles supported on amorphous substrates becomes increasingly difficult when the particle size approaches that of the phase contrast background structures of the support. An approach of digital image analysis, involving Fourier transformation of the original image, filtering, and image reconstruction was studied with respect to the likelihood of unambiguously detecting particles of less than 1 nm diameter on amorphous substrates from a single electron micrograph.

Heinemann, K.↗

Transmission Electron Microscopy based Characterization of a U-20Pu-10Zr Fuel Irradiated in Experimental Breeder Reactor-II

U-Pu-Zr metallic fuels are important fuel candidate for future advanced and/or test reactors. To better understand fuel performance and guide future fuel development, a U-20Pu-10Zr (in weight) metallic fuel irradiated in the Experimental Breeder Reactor was revisited using advanced electron microscopies. This fuel was irradiated to a burnup of 7.6 % at a peak cladding temperature of 521 °C. In this research, several transmission electron microscopy samples were extracted from different but representative radial locations of the fuel cross section using focused ion beam technique. Phase identification and chemical analysis with sub-micron spatial resolution was carried out using scanning transmission electron microscopy. Multiple phenomena that are critical to fuel performance, such as Zr phase and its distribution in a different matrix, were revealed in an unpreceded and highly detailed manner. An improved understanding of fuel reconstruction in U-Pu-Zr metallic fuel under reactor irradiation is provided.

36 MATERIALS SCIENCE↗

Evaluation of Electron Tomography Capabilities for Shale Imaging

Despite the advantageous resolution of electron tomography (ET), reconstruction of three-dimensional (3D) images from multiple two-dimensional (2D) projections presents several challenges, including small signal-to-noise ratios, and a limited projection range. This study evaluates the capabilities of ET for thin sections of shale, a complex nanoporous medium. A numerical phantom with 1.24 nm pixel size is constructed based on the tomographic reconstruction of a Barnett shale. A dataset of 2D projection images is numerically generated from the 3D phantom and studied over a range of conditions. First, common reconstruction techniques are used to reconstruct the shale structure. The reconstruction uncertainty is quantified by comparing overall values of storage and transport metrics, as well as the misclassification of pore voxels compared to the phantom. We then select the most robust reconstruction technique and we vary the acquisition conditions to quantify the effect of artifacts. We find a strong agreement for large pores over the different acquisition workflows, while a wider variability exists for nanometer-scale features. Furthermore, the limited projection range and reconstruction are identified as the main experimental bottlenecks, thereby suggesting that sample thinning, advanced holders, and advanced reconstruction algorithms offer opportunities for improvement.

3D scanning transmission electron microscopy↗

3D Nanotomography of calcium silicate hydrates by transmission electron microscopy

Calcium silicate hydrate (C-S-H), is the principal hydration product of Portland cement that mainly contributes to the physical and mechanical properties of concrete. This paper aims to investigate the three-dimensional structure of C-S-H with Ca/Si ratios of 1.0 and 1.6 at the nanoscale using electron tomography. The 3D reconstructions and selected region of interest analysis confirm that the morphology of both C-S-H materials are foil-like structures. Additionally, the difference between the two materials is the density of elongated structures. C-S-H with Ca/Si ratio 1.6 is clearly composed of denser particles compared to the other C-S-H material due to overlapping of the foil-like structure. Pore analysis shows that C-S-H 1.0 and C-S-H 1.6 have porosities 69.2% and 49.8% respectively. Pore size distribution also reveals that C-S-H 1.0 has pore size range between 0-250 nm and C-S-H 1.6 between 0-100 nm. The pore network's size of C-S-H 1.0 is significantly larger than 1.6. This study illustrates the capability of using electron tomography to determine the 3D nanoscale structure of cementitious products and to distinguish between C-S-H 1.0 and 1.6.

42 ENGINEERING↗

Application of high precision two-way S-band ranging to the navigation of the Galileo Earth encounters

The application of high-accuracy S/S-band (2.1 GHz uplink/2.3 GHz downlink) ranging to orbit determination with relatively short data arcs is investigated for the approach phase of each of the Galileo spacecraft's two Earth encounters (8 December 1990 and 8 December 1992). Analysis of S-band ranging data from Galileo indicated that under favorable signal levels, meter-level precision was attainable. It is shown that ranginging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. Explicit modeling of ranging bias parameters for each station pass is used to largely remove systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle finding capabilities of the data. The accuracy achieved using the precision range filtering strategy proved markedly better when compared to post-flyby reconstructions than did solutions utilizing a traditional Doppler/range filter strategy. In addition, the navigation accuracy achieved with precision ranging was comparable to that obtained using delta-Differenced One-Way Range, an interferometric measurement of spacecraft angular position relative to a natural radio source, which was also used operationally.

Pollmeier, Vincent M.↗

Multibeam Electron Diffraction

One of the primary uses for transmission electron microscopy (TEM) is to measure diffraction pattern images in order to determine a crystal structure and orientation. In nanobeam electron diffraction (NBED), we scan a moderately converged electron probe over the sample to acquire thousands or even millions of sequential diffraction images, a technique that is especially appropriate for polycrystalline samples. However, due to the large Ewald sphere of TEM, excitation of Bragg peaks can be extremely sensitive to sample tilt, varying strongly for even a few degrees of sample tilt for crystalline samples. In this paper, we present multibeam electron diffraction (MBED), where multiple probe-forming apertures are used to create multiple scanning transmission electron microscopy (STEM) probes, all of which interact with the sample simultaneously. We detail designs for MBED experiments, and a method for using a focused ion beam to produce MBED apertures. We show the efficacy of the MBED technique for crystalline orientation mapping using both simulations and proof-of-principle experiments. We also show how the angular information in MBED can be used to perform 3D tomographic reconstruction of samples without needing to tilt or scan the sample multiple times. Finally, we also discuss future opportunities for the MBED method.

47 OTHER INSTRUMENTATION↗