Search NASA⌕ Search

SEARCH · Search NASA

Results for “two phase flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Ghost Fluid/Level Set Method for boiling flows and liquid evaporation: Application to the Leidenfrost effect

The development of numerical methods for the direct numerical simulation of two-phase flows with phase change, in the framework of interface capturing or interface tracking methods, is the main topic of this study. We propose a novel numerical method, which allows dealing with both evaporation and boiling at the interface between a liquid and a gas. Indeed, in some specific situations involving very heterogeneous thermodynamic conditions at the interface, the distinction between boiling and evaporation is not always possible. For instance, it can occur for a Leidenfrost droplet; a water drop levitating above a hot plate whose temperature is much higher than the boiling temperature. In this case, boiling occurs in the film of saturated vapor which is entrapped between the bottom of the drop and the plate, whereas the top of the water droplet evaporates in contact of ambient air. The situation can also be ambiguous for a superheated droplet or at the contact line between a liquid and a hot wall whose temperature is higher than the saturation temperature of the liquid. In these situations, the interface temperature can locally reach the saturation temperature (boiling point), for instance near a contact line, and be cooler in other places. Thus, boiling and evaporation can occur simultaneously on different regions of the same liquid interface or occur successively at different times of the history of an evaporating droplet. Standard numerical methods are not able to perform computations in these transient regimes, therefore, we propose in this paper a novel numerical method to achieve this challenging task. Finally, we present several accuracy validations against theoretical solutions and experimental results to strengthen the relevance of this new method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Heat Transfer Investigation of Liquid and Two-Phase Methane

A heat transfer investigation was conducted for liquid and two-phase methane. The tests were conducted at the NASA Glenn Research Center Heated Tube Facility (HTF) using resistively heated tube sections to simulate conditions encountered in regeneratively cooled rocket engines. This testing is part of NASA s Propulsion and Cryogenics Advanced Development (PCAD) project. Nontoxic propellants, such as liquid oxygen/liquid methane (LO2/LCH4), offer potential benefits in both performance and safety over equivalently sized hypergolic propulsion systems in spacecraft applications. Regeneratively cooled thrust chambers are one solution for high performance, robust LO2/LCH4 engines, but cooling data on methane is limited. Several test runs were conducted using three different diameter Inconel 600 tubes, with nominal inner diameters of 0.0225-, 0.054-, and 0.075-in. The mass flow rate was varied from 0.005 to 0.07 lbm/sec. As the current focus of the PCAD project is on pressure fed engines for LO2/LCH4, the average test section outlet pressures were targeted to be 200 psia or 500 psia. The heat flux was incrementally increased for each test condition while the test section wall temperatures were monitored. A maximum average heat flux of 6.2 Btu/in.2 sec was achieved and, at times, the temperatures of the test sections reached in excess of 1800 R. The primary objective of the tests was to produce heat transfer correlations for methane in the liquid and two-phase regime. For two-phase flow testing, the critical heat flux values were determined where the fluid transitions from nucleate boiling to film boiling. A secondary goal of the testing was to measure system pressure drops in the two-phase regime.

VanNoord, Jonathan↗

Experimental Investigation of Flow Condensation in Microgravity

Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to predict the average condensation heat transfer coefficient with varying degrees of success, and a recent correlation is identified for its superior predictive capability, evidenced by a mean absolute error of 21.7%.

microgravity↗

Conceptual design for spacelab pool boiling experiment

A pool boiling heat transfer experiment to be incorporated with a larger two-phase flow experiment on Spacelab was designed to confirm (or alter) the results of earth-normal gravity experiments which indicate that the hydrodynamic peak and minimum pool boiling heat fluxes vanish at very low gravity. Twelve small sealed test cells containing water, methanol or Freon 113 and cylindrical heaters of various sizes are to be built. Each cell will be subjected to one or more 45 sec tests in which the surface heat flux on the heaters is increased linearly until the surface temperature reaches a limiting value of 500 C. The entire boiling process will be photographed in slow-motion. Boiling curves will be constructed from thermocouple and electric input data, for comparison with the motion picture records. The conduct of the experiment will require no more than a few hours of operator time.

Lienhard, J. H.↗

Computations of Boiling in Microgravity

The absence (or reduction) of gravity, can lead to major changes in boiling heat transfer. On Earth, convection has a major effect on the heat distribution ahead of an evaporation front, and buoyancy determines the motion of the growing bubbles. In microgravity, convection and buoyancy are absent or greatly reduced and the dynamics of the growing vapor bubbles can change in a fundamental way. In particular, the lack of redistribution of heat can lead to a large superheat and explosive growth of bubbles once they form. While considerable efforts have been devoted to examining boiling experimentally, including the effect of microgravity, theoretical and computational work is limited to very simple models. In this project, the growth of boiling bubbles is studied by direct numerical simulations where the flow field is fully resolved and the effects of inertia, viscosity, surface deformation, heat conduction and convection, as well as the phase change, are fully accounted for. The proposed work is based on previously funded NASA work that allowed us to develop a two-dimensional numerical method for boiling flows and to demonstrate the ability of the method to simulate film boiling. While numerical simulations of multi-fluid flows have been advanced in a major way during the last five years, or so, similar capability for flows with phase change are still in their infancy. Although the feasibility of the proposed approach has been demonstrated, it has yet to be extended and applied to fully three-dimensional simulations. Here, a fully three-dimensional, parallel, grid adaptive code will be developed. The numerical method will be used to study nucleate boiling in microgravity, with particular emphasis on two aspects of the problem: 1) Examination of the growth of bubbles at a wall nucleation site and the instabilities of rapidly growing bubbles. Particular emphasis will be put on accurately capturing the thin wall layer left behind as a bubble expands along a wall, on computing instabilities on bubble surfaces as bubbles grow, and on quantifying the effects of both these phenomena on heat transfer; and 2) Examination of the effect of shear flow on bubble growth and heat transfer.

Tryggvason, Gretar↗

Numerical Simulation of No Vent Chill and Fill of a Large Liquid Hydrogen Tank

On orbit transfer of cryogenic liquids is necessary for many future space missions. The techniques required to transfer cryogens in micro gravity are quite different from ground system applications. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor generated due to heat transfer from warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. If the normal gravity technique is used on orbit, the uncertainty of liquid and vapor distributions in unsettled condition may result in dumping of large amounts of liquid propellant overboard. The Vented Chill and No Vent Fill (VCNVF) process is a methodology [1] used to reduce propellant loss by holding the vent valve open during initial wall chilldown, preventing over-pressurization of the tank and stalling of the incoming flow, but closing the tank vent valve after chilling the tank wall sufficiently. An accurate simulation of no vent tank chill and fill is necessary to estimate the amount of propellant necessary to chill the tank, determine the maximum sustainable flowrate to fill the tank without stalling, and establish a timeline for the filling process. Numerical modeling of filling a cryogenic tank is complex because the flow is two-phase and the process involves both boiling and condensation with heat transfer between solid and fluid. In recent years, progress has been made to develop a numerical modeling technique [2,3,4] that has been verified by comparing with the test data from a small flight tank using liquid nitrogen [5]. The purpose of the present paper is to apply this technique in a larger tank with liquid hydrogen and compare with the test data of Chato [1]. The K-site Test Facility [1], shown in Figure 1, consists of a Test Tank, spray system, instrumentation, and the vacuum chamber. The test tank selected was ellipsoidal with an 87 inch major diameter and a 1.2 to 1 major to minor axis ratio. The two ends are joined by a short 1.5 inch cylindrical section. The tank is made of 2219 aluminum chemically milled to a nominal thickness of 0.087 inches. The tank weighs 329.25 pounds, and the tank volume is 175 ft 3 . The GFSSP model of the Test Tank is shown in Figure 2. Node 13 is a boundary node that represents the supply tank which is supplying liquid hydrogen at a given pressure and temperature. The total measured flowrate is evenly distributed through Branches 131 through 139. Nodes 1 through 9 represent the test tank and they are connected with metal solid nodes 14 through 22 through fluid-to-solid conductors that allow convective heat transfer between the solid and fluid nodes. The predicted tank pressure, filling rate, wall temperature and fluid temperature will be compared with test data.

Alok Majumdar↗

RELAP-7 Simulation Resolving an SBO Scenario on a Simplified Geometry of a BWR

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). RELAP-7 will become the main reactor systems toolkit for the Risk-Informed Safety Margin Characterization Pathway of the Light Water Reactor Sustainability Program and the next generation tool in the RELAP reactor safety/systems analysis application series (i.e., the replacement for RELAP5). The code is being developed based on Idaho National Laboratory’s modern scientific software development framework – MOOSE (the Multi-Physics Object-Oriented Simulation Environment). During Fiscal Year 2013, a number of physical components with two-phase flow capability have been developed to support the simplified boiling water reactor (BWR) station blackout analyses. The case selected for demonstration calculation is built from the specifications documented in an Organization for Economic Cooperation and Development benchmark problem for BWR turbine trip analysis. The reference design for the benchmark problem was from the Peach Bottom-2 nuclear station, which is a General Electric BWR-4 design. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for reactor core isolation cooling (RCIC) and the wet well of a BWR containment. The case was initially run to steady-state with RELAP-7. The station blackout transient simulations were subsequently initiated by using the INL-developed RAVEN code. Two scenarios for the station blackout simulations have been considered. Scenario I represents an extreme station blackout accident with no safety injection functioning. The reactor core could experience dry out fairly quickly with this scenario. Scenario II represents a more probable station blackout accident progression with the RCIC system functioning. In this scenario, the RCIC system is fully coupled with the reactor primary system and the safety injection to provide makeup cooling water to the reactor core from the suppression pool is dynamically simulated. With the RCIC system functioning, the core dry out is significantly postponed when compared to the results from Scenario I. This fully coupled RCIC system simulation capability represents the first-of-a-kind simulation capability. Sensitivity studies have also been carried out to study the effect of RCIC control strategy with varying core makeup cooling water mass flow rates. The next stage of development will be to demonstrate more refined BWR station blackout analyses with more realistic geometries, to be reported in the next demonstration simulation report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Collaborative investigation of the internal flow and near-nozzle flow of an eight-hole gasoline injector (Engine Combustion Network Spray G)

The internal details of fuel injectors have a profound impact on the emissions from gasoline direct injection engines. However, the impact of injector design features is not currently understood, due to the difficulty in observing and modeling internal injector flows. Gasoline direct injection flows involve moving geometry, flash boiling, and high levels of turbulent two-phase mixing. In order to better simulate these injectors, five different modeling approaches have been employed to study the engine combustion network Spray G injector. Here these simulation results have been compared to experimental measurements obtained, among other techniques, with X-ray diagnostics, allowing the predictions to be evaluated and critiqued. The ability of the models to predict mass flow rate through the injector is confirmed, but other features of the predictions vary in their accuracy. The prediction of plume width and fuel mass distribution varies widely, with volume-of-fluid tending to overly concentrate the fuel. All the simulations, however, seem to struggle with predicting fuel dispersion and by inference, jet velocity. This shortcoming of the predictions suggests a need to improve Eulerian modeling of dense fuel jets.

ECN↗

Three-Dimensional CFD Simulations in the Film Boiling Regime During Liquid Nitrogen Chilldown Process

The paper presents a three-dimensional CFD simulation for predicting the liquid nitrogen chilldown process through a SS-304 tube. A dispersed mixture model has been employed to predict the two-phase flow behavior whereas the Lee phase change model has been used to predict the boiling process. Cryogenic chilldown process starts with a pure vapor region and proceeds to film, transition and nucleate boiling regimes before reaching the single phase liquid flow and complete chilldown of the transfer line. The present numerical model predicted the film boiling regime accurately and the slope of the chilldown curve deviates slightly from the experimental curve towards the transition and nucleate boiling regime, which needs further investigation. The contours of liquid volume fraction and temperature profiles has been presented to understand the inverted annular film flows in the film boiling regime in detail. In future, the present CFD model will be extended to a wide range of chilldown conditions and different cryogenic fluids to develop a robust methodology.

CFD↗

Flow boiling of R134a in a large surface area microchannel array for high-flux laser diode cooling

Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 &times; 10 mm heated zone centered over a 5 &times; 10 mm array of 125 very small channels (45 &times; 200 &mu;m) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15&deg;C to 25&deg;C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.

42 ENGINEERING↗

Improved Method For Experiments In Vertical-Flow Boiling

Improved method of experimentation in boiling and adiabatic vertical flows provides for simultaneous determination of two-phase frictional pressure drop and vapor-volume fraction. Gravitational pressure drop determined from precise measurements of temperatures and differential pressures in conjunction with quick closure of valves.

Klausner, J. F.↗

Bubble Generation in a Flowing Liquid Medium and Resulting Two-Phase Flow in Microgravity

An experimental and theoretical research program is described herein to study bubble generation in a liquid flow in a pipe under reduced gravity conditions. The objective of the work is to study the bubble size and frequency of the generation and the resulting two-phase flow but it also concerns the fluid mechanical aspects of boiling in forced flow in microgravity. By injecting a gas into a liquid flow in a pipe through a small hole in the pipe wall we will investigate how the bubble expands and detaches from the wall, without involving the complexities of boiling. The experiments will be conducted both under isothermal conditions and with heat transfer from the wall. In the experiments with heat transfer the effect of thermocapillarity on the bubble formation and detachment will be the main subject.

Kamotani, Yasuhiro↗

Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

effect of ambient pressure on the behavior of single-component fuels in a gasoline multi-hole injector

The injection characteristics of neat ethanol and pure isooctane are studied under different ambient pressure and temperature conditions. Injection underflash-boiling conditions can enhance liquid atomization and evaporation, providing the possibility of improvement in the fuel/air mixing. These superheated conditions often introduce phenomena that are not taken into account in the standard modeling of sprays for engine applications. The present work proposes a numerical investigation of the behavior of Engine Combustion Network's 8-hole spray-G injector, starting at the subcooled nominal condition and reducing the ambient pressure at constant low temperature to reach the flare flash-boiling condition. To initialize the properties of the injected fuel, the flow in the nozzle is simulated with a Eulerian approach, handling the two phases with a mixture model and the phase change, due to cavitation and flash boiling, with the Homogenous Relaxation Model. A map of the mixture's kinematic and thermal behavior is obtained at the interface between the injector and the chamber to initialize the Lagrangian simulations. A literature-based vaporization model is implemented to obtain the proper description of the characteristic features of a multi-hole spray under super-heated conditions, like plume-plume interaction. The numerical representation of the spray is validated in terms of penetration and radial spreading on DBI images, reproducing the light attenuation profiles caused by the presence of the liquid spray. Simulations show that coupled nozzle flow and spray calculations capture the spray morphology and shape better compared to calculations performed without considering the nozzle flow simulation details, especially under flare flash conditions.

Nocivelli, Lorenzo↗

Simulation of Boiling Flow in a Helical Coil Using a Homogeneous Equilibrium Model with the Nek-2P CFD Code

Recent developments in the field of nuclear energy have lead to an increased interest in the design of helically coiled steam generators. In particular, their compact size, and high heat transfer rates make them ideal for small modular reactors. This has lead to a renewed effort to investigate the characteristics of fluid flow and heat transfer in and around helical coils both numerically and experimentally. The focus of this work is on the development of a consistent modeling, formulation, and simulation framework for boiling flows in helical coils using the highly scalable Nek-2P CFD code. As a first step, two phase flow is accounted for using a homogeneous equilibrium model. Results for both single and multiphase flows are compared to results obtained from Star-CCM+. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling of internal and near-nozzle flow for a GDI fuel injector

A numerical study of two-phase flow inside the nozzle holes and the issuing spray jets for a multi-hole direct injection gasoline injector has been presented in this work. The injector geometry is representative of the Spray G nozzle, an eight-hole counterbore injector, from the Engine Combustion Network (ECN). Simulations have been carried out for a fixed needle lift. Effects of turbulence, compressibility and non-condensable gases have been considered in this work. Standard k -ε turbulence model has been used to model the turbulence. Homogeneous Relaxation Model (HRM) coupled with Volume of Fluid (VOF) approach has been utilized to capture the phase change phenomena inside and outside the injector nozzle. Three different boundary conditions for the outlet domain have been imposed to examine non-flashing and evaporative, non-flashing and non-evaporative and flashing conditions. Noticeable hole-to-hole variations have been observed in terms of mass flow rates for all the holes under all the operating conditions considered in this study. Inside the nozzle holes mild cavitation-like and in the near-nozzle region flash boiling phenomena have been predicted when liquid fuel is subjected to superheated ambiance. Under favorable conditions considerable flashing has been observed in the near-nozzle regions. An enormous volume is occupied by the gasoline vapor, stantial computational cost. Volume-averaging instead of mass-averaging is observed to be more effective, especially for finer mesh resolutions.

42 ENGINEERING↗

Assessment of the Subchannel Code CTF for Single- and Two-Phase Flows

As part of the Consortium for Advanced Simulation of Light Water Reactors, the subchannel code CTF is being used for single-phase and two-phase flow analysis under light water reactor operating conditions. Accurate determination of flow distribution, pressure drop, and void content is crucial for predicting margins to thermal crisis and ensuring more efficient plant performance. In preparation for the intended applications, CTF has been validated against data from experimental facilities comprising the General Electric (GE) 3 × 3 bundle, the boiling water reactor full-size fine-mesh bundle tests (BFBTs), the Risø tube, and the pressurized water reactor subchannel and bundle tests (PSBTs). Meanwhile, the licensed, well-recognized subchannel code VIPRE-01 was used to generate a baseline set of simulations for the targeted tests and solution parameters were compared to the CTF results.The flow split verification problem and single-phase GE 3 × 3 results are essentially in perfect agreement between the two codes. For the two-phase GE 3 × 3 cases, flow and quality discrepancies arise in the annular-mist flow regime, yet significant improvement is observed in CTF when void drift and two-phase turbulent mixing enhancement are considered. The BFBT pressure drop benchmark shows close agreement between predicted and measured results in general, although considerable overprediction by CTF is observed at relatively high void locations of the facility. This overestimation tendency is confirmed by the Risø cases. While overall statistics are satisfactory, both BFBT and PSBT bubbly-to-churn flow void contents are markedly overpredicted by CTF.The issues with two-phase closures such as turbulent mixing, interfacial and wall friction, and subcooled boiling heat transfer need to be addressed. As a result, preliminary sensitivity studies are presented herein, but more advanced models and code stability analysis require further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗