Search NASA⌕ Search

SEARCH · Search NASA

Results for “two photon absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Instrumentation Working Group Summary

The Instrumentation Working Group compiled a summary of measurement techniques applicable to gas turbine engine aerosol precursors and particulates. An assessment was made of the limits, accuracy, applicability, and technology readiness of the various techniques. Despite advances made in emissions characterization of aircraft engines, uncertainties still exist in the mechanisms by which aerosols and particulates are produced in the near-field engine exhaust. To adequately assess current understanding of the formation of sulfuric acid aerosols in the exhaust plumes of gas turbine engines, measurements are required to determine the degree and importance of sulfur oxidation in the turbine and at the engine exit. Ideally, concentrations of all sulfur species would be acquired, with emphasis on SO2 and SO3. Numerous options exist for extractive and non-extractive measurement of SO2 at the engine exit, most of which are well developed. SO2 measurements should be performed first to place an upper bound on the percentage of SO2 oxidation. If extractive and non-extractive techniques indicate that a large amount of the fuel sulfur is not detected as SO2, then efforts are needed to improve techniques for SO3 measurements. Additional work will be required to account for the fuel sulfur in the engine exhaust. Chemical Ionization Mass Spectrometry (CI-MS) measurements need to be pursued, although a careful assessment needs to be made of the sampling line impact on the extracted sample composition. Efforts should also be placed on implementing non-intrusive techniques and extending their capabilities by maximizing exhaust coverage for line-of-sight measurements, as well as development of 2-D techniques, where feasible. Recommendations were made to continue engine exit and combustor measurements of particulates. Particulate measurements should include particle size distribution, mass fraction, hydration properties, and volatile fraction. However, methods to ensure that unaltered samples are obtained need to be developed. Particulate speciation was also assigned a high priority for quantifying the fractions of carbon soot, PAH, refractory materials, metals, sulfates, and nitrates. High priority was also placed on performing a comparison of particle sizing instruments. Concern was expressed by the workshop attendees who routinely make particulate measurements about the variation in number density measured during in-flight tests by different instruments. In some cases, measurements performed by different groups of researchers during the same flight tests showed an order of magnitude variation. Second priority was assigned to measuring concentrations of odd hydrogen and oxidizing species. Since OH, HO2, H2O2, and O are extremely reactive, non-extractive measurements are recommended. A combination of absorption and fluorescence is anticipated to be effective for OH measurements in the combustor and at the engine exit. Extractive measurements of HO2 have been made in the stratosphere, where the ambient level of OH is relatively low. Use of techniques that convert HO2 to OH for combustor and engine exit measurements needs to be evaluated, since the ratio of HO2/OH may be 1% or less at both the combustor and engine exit. CI-MS might be a viable option for H2O2, subject to sampling line conversion issues. However, H2O2 is a low priority oxidizing species in the combustor and at the engine exit. Two candidates for atomic oxygen measurements are Resonance Enhanced Multi-Photon Ionization (REMPI) and Laser-Induced Fluorescence (LIF). Particulate measurement by simultaneous extractive and non-extractive techniques was given equal priority to the oxidizer measurements. Concern was expressed over the ability of typical ground test sampling lines to deliver an unaltered sample to a remotely located instrument. It was suggested that the sampling probe and line losses be checked out by attempting measurements using an optical or non-extractive technique immediately upstream of the sampling probe. This is a possible application for Laser Induced Incandescence (LII) as a check on the volume fraction of soot. Optical measurements of size distribution are not well developed for ultrafine particles less than about 20 nm in diameter, so a non-extractive technique for particulate size distribution cannot be recommended without further development. Carbon dioxide measurements need to be made to complement other extractive measurement techniques. CO2 measurements enable conversion of other species concentrations to emission indices. Carbon monoxide, which acts as a sink for oxidizing species, should be measured using non-extractive techniques. CO can be rapidly converted to CO2 in extractive probes, and a comparison between extractive and non-extractive measurements should be performed. Development of non-extractive techniques would help to assess the degree of CO conversion, and might be needed to improve the concentration measurement accuracy. Measurements of NO(x) will continue to be critical due to the role of NO and NO2 in atmospheric chemistry, and their influence on atmospheric ozone. Time-resolved measurements of temperature, velocity, and species concentrations were included on the list of desired measurement. Thermocouples are typically adequate for engine exit measurements. PIV and LDV are well established for obtaining velocity profiles. The techniques are listed in the accompanying table; are divided into extractive and non-extractive techniques. Efforts were made to include a measurement uncertainty for each technique. An assessment of the technology readiness was included.

Zaller, Michelle↗

Comparative lifetesting results for microchannel plates in windowless EUV photon detectors

Microchannel plates (MCPs) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (l/d) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCPs with l/d's of 80:1. Results for MCPs with funnelled channel throats are also discussed. Properties of the MCPs which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100 C, and charge extraction to 0.01 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.

Malina, R. F.↗

X-Ray Imaging-Spectroscopy of Abell 1835

We present detailed spatially-resolved spectroscopy results of the observation of Abell 1835 using the European Photon Imaging Cameras (EPIC) and the Reflection Grating Spectrometers (RGS) on the XMM-Newton observatory. Abell 1835 is a luminous (10(exp 46)ergs/s), medium redshift (z = 0.2523), X-ray emitting cluster of galaxies. The observations support the interpretation that large amounts of cool gas are present in a multi-phase medium surrounded by a hot (kT(sub e) = 8.2 keV) outer envelope. We detect O VIII Ly(alpha) and two Fe XXIV complexes in the RGS spectrum. The emission measure of the cool gas below kT(sub e) = 2.7 keV is much lower than expected from standard cooling-flow models, suggesting either a more complicated cooling process than simple isobaric radiative cooling or differential cold absorption of the cooler gas.

Peterson, J. R.↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

Analysis of Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption from 3-13 km Altitudes

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS space mission [1]. It uses two pulsed laser transmitters allowing simultaneous measurement of a CO2 absorption line in the 1575 nm band, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are precisely stepped in wavelength across the CO2 line and an O2 line region during the measurement. The direct detection receiver measures the energies of the laser echoes from the surface along with the range profile of scattering in the path. The column densities for the CO2 and O2 gases are estimated from the ratio of the on- and off-line signals via the integrated path differential absorption (IPDA) technique. The time of flight of the laser pulses is used to estimate the height of the scattering surface and to reject laser photons scattered in the atmosphere. We developed an airborne lidar to demonstrate an early version of the CO2 measurement from the NASA Glenn Lear-25 aircraft. The airborne lidar stepped the pulsed laser's wavelength across the selected CO2 line with 20 wavelength steps per scan. The line scan rate is 450 Hz, the laser pulse widths are 1 usec, and laser pulse energy is 24 uJ. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a NIR photomultiplier and is recorded on every other reading by a photon counting system [2]. During August 2009 we made a series of 2.5 hour long flights and measured the atmospheric CO2 absorption and line shapes using the 1572.33 nm CO2 line. Measurements were made at stepped altitudes from 3-13 km over locations in the US, including the SGP ARM site in Oklahoma, central Illinois, north-eastern North Carolina, and over the Chesapeake Bay and the eastern shore of Virginia. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes, and some measurements were made through thin clouds. The Oklahoma and east coast flights were coordinated with a LaRC/ITT CO2 lidar on the LaRC UC-12 aircraft, and in-situ measurements were made using its CO2 sensor and radiosondes. We have conducted an analysis of the ranging and IPDA lidar measurements from these four flights. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We used a cross-correlation approach to process the laser echo records. This was used to estimate the range to the scattering surface, to define the edges of the laser pulses and to determine echo pulse energy at each wavelength. We used a minimum mean square approach to fit an instrument response function and to solve for the best-fit CO2 absorption line shape. We then calculated the differential optical depth (DOD) of the fitted CO2 line. We computed its statistics at the various altitude steps, and compare them to the DODs calculated from spectroscopy based on HITRAN 2008 and the column conditions calculated from the airborne in-situ readings. The results show the lidar and in-situ measurements have very similar DOD change with altitude and greater than 10 segments per flight where the scatter in the lidar measurements are less than or equal to 1ppm. We also present the results from subsequent CO2 column absorption measurements, which were made with stronger detected signals during three flights on the NASA DC-8 over the southwestern US in during July 2010.

Abshire, James B.↗

Background studies in gas ionizing x ray detectors

The background response of a gas ionizing proportional x ray detector is estimated by solving the one dimensional photon transport equation for two regions using Monte Carlo techniques. The solution was effected using the SSL VAX 780 and the CRAY XMP computers at Marshall Space Flight Center. The isotropic photon energy spectrum encompassing the range from 1 to 1000 KeV incident onto the first region, the shield, is taken so as to represent the measured spectrum at an altitude of 3 mb over Palastine, Texas. The differential energy spectrum deposited in the gas region, xenon, over the range of 0 to 100 KeV is written to an output file. In addition, the photon flux emerging from the shield region, tin, over the range of 1 to 1000 KeV is also tabulated and written to a separate file. Published tabular cross sections for photoelectric, elastic and inelastic Compton scattering as well as the total absorption coefficient are used. Histories of each incident photon as well as secondary photons from Compton and photoelectric interactions are followed until the photon either is absorbed or exits from the regions under consideration. The effect of shielding thickness upon the energy spectrum deposited in the xenon region for this background spectrum incident upon the tin shield was studied.

Eldridge, Hudson B.↗

Coherent Effects in Tiny Optics: Tunneling Through the Looking Glass

I will discuss two types of one-dimensional photonic bandgap (PBG) effects that can arise in systems of coupled spherical resonators: (1) nearly-free-photon Fabry-Perot photonic bands that arise in quarter-wave concentrically stratified spheres and, (2) tight- binding photonic bands that arise in weakly-coupled mutually-resonant spheres as a result of whispering-gallery mode splitting. These effects can be derived directly from Mie theory, in a more straightforward manner, by exploiting an analogy with stratified planar systems. For odd numbers of mutually-resonant lossless coupled ring resonators, the circulating intensity can increase exponentially with the number of resonators, which can potentially be exploited for the development of advanced sensors. For even numbers of resonators, mode splitting and classical destructive interference lead to a cancellation of absorption and slow light on-resonance, reminiscent of electromagnetic induced transparency. The analogy between these coherent photon trapping effects and population trapping in an atomic system will be explored.

Smith, David D.↗

Reduced dimer production in solar-simulator-pumped continuous wave iodine lasers based on model simulations and scaling and pumping studies

A numerical rate equation model for a continuous wave iodine laser with longitudinally flowing gaseous lasant is validated by approximating two experiments that compare the perfluoroalkyl iodine lasants n-C3F7I and t-C4F9I. The salient feature of the simulations is that the production rate of the dimer (C4F9)2 is reduced by one order of magnitude relative to the dimer (C3F7)2. The model is then used to investigate the kinetic effects of this reduced dimer production, especially how it improves output power. Related parametric and scaling studies are also presented. When dimer production is reduced, more monomer radicals (t-C4F9) are available to combine with iodine ions, thus enhancing depletion of the laser lower level and reducing buildup of the principal quencher, molecular iodine. Fewer iodine molecules result in fewer downward transitions from quenching and more transitions from stimulated emission of lasing photons. Enhanced depletion of the lower level reduces the absorption of lasing photons. The combined result is more lasing photons and proportionally increased output power.

Costen, Robert C.↗

Photocatalytic Coatings for Exploration and Spaceport Design

This project developed self-cleaning photocatalytic coatings that remove contamination without human intervention. The coatings chemically remove organic contaminants and leave no residue. The photocatalyst will not negatively affect other coating properties, especially corrosion resistance. Titanium dioxide, TiO2, is an extremely popular photocatalyst because of its chemical stability, nontoxicity, and low cost. TiO2 is commonly used in the photocatalytic oxidation of organic matter or pollutants in the gas and liquid phases. However, TiO2 does have some drawbacks. It has limited light absorption because of its large band-gap and suffers from a photonic efficiency of less than 10 percent for organic degradation. Dopants can lower the band-gap and improve efficiency. Since the photocatalytically active form of TiO2 is a nanocrystalline powder, it can be difficult to make a robust coating with enough catalyst loading to be effective. Photocatalysts become active when certain light energy is absorbed. When photons with an energy greater than the band-gap, Eg, (wavelengths shorter than 400 nm) impinge upon the surface of the TiO2, an electron-hole pair is formed. The electron-hole pair oxidizes adsorbed substances either directly or via reactive intermediates that form on the surface, such as hydroxyl radicals (OH) or superoxide ions (O2-). Several factors can influence the band-gap energy of TiO2, two of which are crystal structure and impurities. TiO2 exists as three crystal structures brookite, anatase, and rutile that can be controlled via heat treatment. Anatase is the most photocatalytically active crystal form of TiO2. Doping TiO2 with impurities can alter its band-gap energy, as well as its effectiveness as a catalyst. Depending on their size, dopant atoms can occupy either the substitutional or interstitial lattice positions. Atoms that are relatively large will assume the interstitial positions and create a much greater energy disturbance in the crystal than will smaller atoms that take on the substitutional positions. This energy disturbance narrows the band-gap and thus allows photons with longer wavelengths and smaller energies (such as those in the visible-light spectrum) to create electron-hole pairs. Raman spectroscopy was performed for the purpose of determining the crystal structure and the degree of crystallinity of the TiO2 particles. Reflectance measurements indicated the wavelengths of light absorbed by the different catalysts.

Source record↗

Pulsed Lidar for Measurement of C02 Concentrations for the ASCENDS Mission - Update

We have been developing a laser-based sounding technique for the remote measurement of the tropospheric CO2 concentrations from orbit for NASA is ASCENDS mission. The mission's goals are to provide measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution. These are needed to better understand CO2 fluxes and the processes that regulate CO2 storage by the land and oceans. For the lIP, we are developing and demonstrating the lidar techniques and key lidar technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to demonstrate the key capabilities needed for a space lidar and mission approach for the ASCENDS mission. We use a pulsed lidar technique, which is much less sensitive to errors from cloud and atmospheric scattering and to noise from solar background. It allows continuous measurements of CO2 mixing ratio in the lower troposphere during day and night. Our approach uses the 1570nm CO2 band and a two-wavelength laser absorption spectrometer, which continuously measures at nadir from a circular polar orbit. It directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses a pair of tunable laser transmitters, which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band and from a line pair in the Oxygen A-band near 765 nm. These regions have temperature insensitive absorption lines are free from interference from other gases. The lasers pulse at 10KHz, use tunable diode seed lasers followed by laser amplifiers, and have MHz spectral widths. During the measurement the lasers are stepped across the selected lines at a kHz rate. The receiver uses a 1-m class telescope and photon sensitive detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and off line echo pulse energies via the integrated path differential absorption (IPDA) technique. Our technique exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. Pulsed laser signals, time gated receiver are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. We have successfully demonstrated many key aspects of the approach and lidar technology in the laboratory. We have demonstrated CO2 column measurements in airborne flights during the summers of 2009 and 2010. These included measurements from 3-l3 km altitudes made over a variety of surfaces and through thin and broken clouds. We demonstrated initial airborne measurements of O2 column density to 10 km altitudes during the summer 2010 flights. More details approach, key technologies, and demonstration measurements will be given in the presentation.

Abshire, James↗

Cyclotron Line Measurements with INTEGRAL

Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

Pottschmidt, K.↗

SIRENA Software for Athena X-IFU Event Reconstruction

The X-ray Observatory Athena was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESAs Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard Athena is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by an international consortium led by IRAP (PI), SRON (co-PI) and IAPS/INAF (co-PI) and involving ESA Member States, Japan and the United States. In Spain, IFCA (CSIC-UC) has an anticipated contribution to X-IFU through the Digital Readout Electronics (DRE) unit, in particular in the Event Processor Subsytem. For this purpose and in collaboration with the Athena end-to-end simulations team, we are currently developing the SIRENA package as part of the publicly available SIXTE end-to-end simulator. SIRENA comprises a set of processing algorithms aimed at recognizing, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, to lately reconstruct their energy, position and arrival time. This poster describes the structure of the package and the different algorithms currently implemented as well as their comparative performance in the energy resolution achieved in the reconstruction of the instrument events.

M T Ceballos↗

Dip Spectroscopy of the Low Mass X-Ray Binary XB 1254-690

We observed the low mass X-ray binary XB 1254-690 with the Rossi X-ray Timing Explorer in 2001 May and December. During the first observation strong dipping on the 3.9-hr orbital period and a high degree of variability were observed, along with "shoulders" approx. 15% deep during extended intervals on each side of the main dips. The first observation also included pronounced flaring activity. The non-dip spectrum obtained using the PCA instrument was well-described by a two-component model consisting of a blackbody with kT = 1.30 +/- 0.10 keV plus a cut-off power law representation of Comptonized emission with power law photon index 1.10 +/- 0.46 and a cut-off energy of 5.9(sup +3.0, sub -1.4) keV. The intensity decrease in the shoulders of dipping is energy-independent, consistent with electron scattering in the outer ionized regions of the absorber. In deep dipping the depth of dipping reached 100%, in the energy band below 5 keV, indicating that all emitting regions were covered by absorber. Intensity-selected dip spectra were well-fit by a model in which the point-like blackbody is rapidly covered, while the extended Comptonized emission is progressively overlapped by the absorber, with the, covering fraction rising to 95% in the deepest portion of the dip. The intensity of this component in the dip spectra could be modeled by a combination of electron scattering and photoelectric absorption. Dipping did not occur during the 2001 December observation, but remarkably, both bursting and flaring were observed contemporaneously.

Smale, Alan P.↗

Looking for Speed!! Go Optical Ultra-Fast Photonic Logic Gates for the Future Optical Communication and Computing

Recently, we developed two ultra-fast all-optical switches in the nanosecond and picosecond regimes. The picosecond switch is made of a polydiacetylene thin film coated on the interior wall of a hollow capillary of approximately 50 micron diameter by a photo-polymerization process. In the setup a picosecond Nd:YAG laser at 10 Hz and at 532 nm with a pulse duration of approximately 40 ps was sent collinearly along a cw He-Ne laser beam and both were waveguided through the hollow capillary. The setup functioned as an Exclusive OR gate. On the other hand, the material used in the nanosecond switch is a phthalocyanine thin film, deposited on a glass substrate by a vapor deposition technique. In the setup a nanosecond, 10 Hz, Nd:YAG laser of 8 ns pulse duration was sent collinearly along a cw He-Ne laser beam and both were wave-guided through the phthalocyanine thin film. The setup in this case functioned as an all-optical AND logic gate. The characteristic table of the ExOR gate in polydiacetylene film was attributed to an excited state absorption process, while that of the AND gate was attributed to a saturation process of the first excited state. Both mechanisms were thoroughly investigated theoretically and found to agree remarkably well with the experimental results. An all-optical inverter gate has been designed but has not yet been demonstrated. The combination of all these three gates form the foundation for building all the necessary gates needed to build a prototype of an all-optical system.

Abdeldayem, Hossin↗

Two-sample discrimination of Poisson means

This paper presents a statistical test for detecting significant differences between two random count accumulations. The null hypothesis is that the two samples share a common random arrival process with a mean count proportional to each sample's exposure. The model represents the partition of N total events into two counts, A and B, as a sequence of N independent Bernoulli trials whose partition fraction, f, is determined by the ratio of the exposures of A and B. The detection of a significant difference is claimed when the background (null) hypothesis is rejected, which occurs when the observed sample falls in a critical region of (A, B) space. The critical region depends on f and the desired significance level, alpha. The model correctly takes into account the fluctuations in both the signals and the background data, including the important case of small numbers of counts in the signal, the background, or both. The significance can be exactly determined from the cumulative binomial distribution, which in turn can be inverted to determine the critical A(B) or B(A) contour. This paper gives efficient implementations of these tests, based on lookup tables. Applications include the detection of clustering of astronomical objects, the detection of faint emission or absorption lines in photon-limited spectroscopy, the detection of faint emitters or absorbers in photon-limited imaging, and dosimetry.

Lampton, M.↗

Spatially Resolved Spectroscopy of the SNR IC443

IC 443 is a supernova remnant of intermediate age, i.e. a few thousand years. It is especially interesting because part of its periphery is expanding into a molecular cloud while other sections are expanding into a typical interstellar medium of much lower density. Since the evolution of a supernova remnant through its various phases is affected by the density of the medium it expands into with the reasonable assumption that the supernova explosion was approximately symmetric we have an opportunity to observe a single object in two phases simultaneously. It was observed by ASCA in April, 1993 for a short period during the PV phase and more thoroughly in a 42 ksec exposure in March, 1994. The latter measurement provides most of the results that have been reported. Most of the analysis took place after the grant ended but is included here for completeness. The data was sent simultaneously to US and Japanese Pls. We worked independently. The software set of FTOOLs was used to construct images and spectra. They were judged to be rather unintuitive and not at all user friendly. I found I was using one FTOOL to read the header to obtain information that would only be provided to another FTOOL. The Japanese investigators were more successful. They analyzed the data and published results more rapidly. The scientific results summarized below are based primarily on their publications. Since IC 443 is an interesting example of a middle aged SNR in which a variety of processes are occurring it is one of a class. IC 443 exhibits shell-like emission in hard X-rays and extended soft X-rays with thin thermal spectra. It resembles SN 1006 in these respects. IC 443 contains hard X-rays in a semi-circular shell surrounding the thermal component. The total hard X-ray flux in the ASCA FOV is only a half of the Ginga hard component; which suggests that the hard X-rays are not confined only in the shell but some are extended larger than the ASCA FOV of eq 1 degree diameter. Japanese investigators examined the spatial structure of the thermal component and analyzed the GIS spectra with a non-equilibrium plasma model, and found no systematic variation of the interstellar absorption across the remnant. Evidence for shock acceleration of cosmic rays to high energies (10 TeV) was found by Keohane. X-ray imaging spectroscopy with ASCA reveals two regions of particularly hard emission: an unresolved source embedded in an extended emission region, and a ridge of emission coincident with the southeastern rim. Both features are located on part of the radio shell where the shock wave is interacting with molecular gas, and together they account for a majority of the emission at 7 keV. Though we would not have noticed it a priori, the unresolved feature is coincident with one resolved by the ROSAT HRI. The ASCA measurements were combined with higher energy data from the XTE and GRO missions and with radio and TeV gamma-ray data to produce a nonthermal multiwavelength spectrum for IC 443 which was fit with a cosmic ray interaction model. This model calculates the cynchrotron, bremsstrahlung, invers Compton, and neutral pion decay emission produced by locally accelerated cosmic ray interacting with ambient matter, soft photon fields, and magnetic fields.

Gorenstein, P.↗

Infrared to x-ray spectral energy distributions of high redshift quasars

We have observed 14 quasars with z greater than 2.8 with the ROSAT-PSPC, and detected 12 of them, including the z=4.11 quasar 0000-263. We present the first x-ray spectrum of a radio quiet quasar with z greater than 3, 1946+768. Its x-ray spectrum is consistent with a power law with spectral index alpha(sub E)=1.8(sup +2.1, sub -1.4) and no evidence for absorption in excess of the galactic column (alpha(sub E)=1.00(sup +0.28, sub -0.32) assuming N(sub H)=N(sub H)(Gal)). A Position Sensitive Proportional Counter (PSPC) hardness ratio is used to constrain the x-ray spectral properties of the quasars for which there were less than 100 photons detected. For the radio quiet quasars, (alpha(sub E)) approximately equals 1.2, if one assumes that there is no absorption in excess of the galactic column. We combine the x-ray data with new ground based optical and near-IR spectrophotometry obtained at the Steward 2.3 m and Multiple Mirror Telescope, and data from the literature. The spectral energy distributions are compared to those of low redshift objects. For the radio quiet quasars with z greater than 2.5, the mean (alpha(sub ox)) is approximately 1.8. This is larger than the mean for quasars with z less than 2.5, but consistent with the expected value for quasars with the high optical luminosities of the objects in this sample. For the radio-loud quasars, (alpha(sub ox)) is approximately 1.4, independent of redshift. This is smaller than the expected value for the optically luminous, high redshift objects in this sample, if they are mostly GHz peaked radio sources and hence comparable to steep-spectrum, compact radio sources at lower redshift. Finally, we compare the spectral energy distributions of two representative objects to the predicted spectrum of a thin accretion disk in the Kerr geometry, and discuss the uncertainties in deriving black hole masses and mass accretion rates.

Bechtold, Jill↗

IUE observations of oxygen-rich supernova remnants

The IUE observations were used to determine the composition of the ejecta (especially C and Si abundances) and to test models for the ionization and excitation of the ejecta of two oxygen-rich supernova remnants (N132D in the Large Magellanic Cloud and 1E 0102-7219 in the Small Magellanic Cloud). Time-dependent photoionization by the EUV and X-ray radiation from 1E 0102-7219 can qualitatively explain its UV and optical line emission, but the density and ionization structures are complex and prevent a unique model from being specified. Many model parameters are poorly constrained, including the time dependence and shape of the ionizing spectrum. Moreover, the models presented are not self-consistent in that the volumes and densities of the optically emitting gas imply optical depths of order unity in the EUV, but absorption of the ionizing radiation was ignored. It is possible that these shortcomings reflect a more fundamental limitation of the model assumptions. It is assumed that the electron velocity distribution is Maxwellian and that the energy deposited by photoionization heats the electrons directly. The 500 eV electrons produced by the Auger process may excite or ionize other ions before they slow down enough to share their energy with other electrons. Many of the excitations would produce photons that could ionize lower ionization stages.

Blair, W. P.↗