Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator

Ultra-high-spectral-resolution X-Ray/EUV monochromator depends on Bragg reflection from multilayer coats and diffraction by mutlilayer-coated grating to select narrow wavelength band from input beam. Its monochromatic output beam of accurately known wavelength very useful in testing and calibration of x-ray telescopes, x-ray microscopes, photographic films, and photodetectors; in research in biological and biomedical disciplines, x-ray crystallography, properties and processing of materials, and x-ray lasers; and in x-ray lithography.

Hoover, Richard B.↗

The ultra high resolution XUV spectroheliograph: An attached payload for the Space Station Freedom

The principle goal of the ultra high resolution XUV spectroheliograph (UHRXS) is to improve the ability to identify and understand the fundamental physical processes that shape the structure and dynamics of the solar chromosphere and corona. The ability of the UHRXS imaging telescope and spectrographs to resolve fine scale structures over a broad wavelength (and hence temperature) range is critical to this mission. The scientific objectives and instrumental capabilities of the UHRXS investigation are reviewed before proceeding to a discussion of the expected performance of the UHRXS observatory.

Walker, Arthur B. C., Jr.↗

The LDEF ultra heavy cosmic ray experiment

The Long Duration Exposure Facility (LDEF) Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of 4 pressure vessels (3 experiment tray). The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 2000 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Postflight work to date and the current status of the experiment are reviewed. Provisional results from analysis of preflight and postflight calibrations are presented.

Osullivan, D.↗

Ultra-high-power plasma switch INPIS for pulse power systems

A novel plasma switch, the inverse pinch switch (IN-PIS), with a combination geometry based on an inverse-pinch mechanism, has been tested and shown to alleviate the shortcomings of conventional spark gaps. The INPIS switch or INPIStron is currently being upscaled for high-voltage (approximately 1 MV) operation with a multigap arrangement similar to Sandia's rimfire electrodes used for ultra-high-voltage hold off. Preliminary results of the multigap INPIS tests at 230 kV and plasma-puff initiation methods are presented, and an application to compact pulser systems is discussed.

Lee, Ja H.↗

Ultra-precision processes for optics manufacturing

The Optics MODIL (Manufacturing Operations Development and Integration Laboratory) is developing advanced manufacturing technologies for fabrication of ultra precision optical components, aiming for a ten-fold improvement in precision and a shortening of the scheduled lead time. Current work focuses on diamond single point turning, ductile grinding, ion milling, and in/on process metrology.

Martin, William R.↗

The LDEF ultra heavy cosmic ray experiment

The LDEF Ultra Heavy Cosmic Ray Experiment (UHCRE) used 16 side viewing LDEF trays giving a total geometry factor for high energy cosmic rays of 30 sq m sr. The total exposure factor was 170 sq m sr y. The experiment is based on a modular array of 192 solid state nuclear track detector stacks, mounted in sets of four in 48 pressure vessels. The extended duration of the LDEF mission has resulted in a greatly enhanced potential scientific yield from the UHCRE. Initial scanning results indicate that at least 1800 cosmic ray nuclei with Z greater than 65 were collected, including the world's first statistically significant sample of actinides. Post flight work to date and the current status of the experiment are reviewed.

Osullivan, D.↗

Microwelding (or cold-welding) of various metallic materials under the ultra-vacuum LDEF experiment AO 138-10

The FRECOPA experimentation, as part of the Long Duration Exposure Facility (LDEF) mission, of mechanical and electrical parts of spacecraft in space ultra-vacuum has demonstrated freedom from any cold welding including microweld effects. This, as theorized, is due to integrity in space of the earthly grown oxygen layer. A further experimentation, a dynamic one this time, could provide a wealth of scientific data, yielding reliable material selecting criteria.

Assie, Jean-Pierre↗

A comparison of Ultra-Sensitive Coherent Detection (USCD) and heterodyne detection for a wind sensing application

Ultra-Sensitive Coherent Detection (USCT) and conventional heterodyne detection methods were evaluated for use as a space-borne wind sensing system. For this study, we assume that the wind sensing system would be available by the year 2015. Consequently, laser systems and detectors more advanced than those under consideration for near term programs could be included. Three laser candidates under evaluation are Nd-YAG at 1.06 microns, Ho-YAG at 2.1 microns, and CO2 at 9.11 microns. Both heterodyne and USCD detection methods were included. The primary stress is on the optimization of weight and power consumption of the wind sensor portion of the satellite system.

Amimoto, Sherwin↗

An ultra-sensitive coherent detector capable of single photon detection for lidar applications

The properties of Ultra-Sensitive Coherent Detectors (USCD's) are nearly that of an ideal detector for lidar applications. Recent progress in the development of USCD's is briefly reviewed, and its imaging capability is demonstrated. These new detectors possess properties with significant improvements over conventional technology. These improvements include a high quantum efficiency of 0.95, gain in excess of 10 exp 13, a narrow bandwidth of 180-300 MHz at 1 micron, imaging capability, and phase conjugation ability. We have constructed a USCD using two Nd:YAG laser amplifiers and a four-wave Brillouin mirror (FWBM) using SnCl4 as the Brillouin medium. Using a 10 Hz repetitively-pulsed single frequency laser, we have shown that the Brillouin medium is free from thermal blooming and from optical breakdown.

Amimoto, Sherwin↗

True covariance simulation of the EUVE (extreme ultra violet explorer) update filter

This paper presents a covariance analysis of the performance and sensitivity of the attitude determination Extended Kalman Filter (EKF) used by the onboard computer (OBC) of the Extreme Ultra Violet Explorer (EUVE) spacecraft. The linearized dynamics and measurement equations of the error states are used in formulating the 'truth model' describing the order of the systems involved. The 'design model' used by the OBC EKF is then obtained by reducing the order of the truth model. The covariance matrix of the EKF which uses the reduced order model is not the correct covariance of the EKF estimation error. A 'true covariance analysis' has to be carried out in order to evaluate the correct accuracy of the OBC generated estimates. The results of such analysis are presented which indicate both the performance and the sensitivity of the OBC EKF.

Bar-Itzhack, I. Y.↗

An improved offset generator developed for Allan deviation measurement of ultra stable frequency standards

Measuring the performance of ultra stable frequency standards such as the Superconducting Cavity Maser Oscillator (SCMO) necessitates improvement of some test instrumentation. The frequency stability test equipment used at JPL includes a 1 Hz Offset Generator to generate a beat frequency between a pair of 100 MHz signals that are being compared. The noise floor of the measurement system using the current Offset Generator is adequate to characterize stability of hydrogen masers, but it is not adequate for the SCMO. A new Offset Generator with improved stability was designed and tested at JPL. With this Offset Generator and a new Zero Crossing Detector, recently developed at JPL, the measurement flow was reduced by a factor of 5.5 at 1 second tau, 3.0 at 1000 seconds, and 9.4 at 10,000 seconds, compared against the previous design. In addition to the new circuit designs of the Offset Generator and Zero Crossing Detector, tighter control of the measurement equipment environment was required to achieve this improvement. The design of this new Offset Generator are described, along with details of the environment control methods used.

R. L. Hamell↗

The Ultra High Resolution XUV Spectroheliograph. II - Predicted performance

The phenomena to be studied with the Ultra-High Resolution XUV Spectroheliograph (UHRXS) which will be included into the instrumental load of the Space Station Freedom are discussed together with the characteristics of the nine multilayer Ritchey-Chretien telescopes constituting the UHRXS system. The telescopes will cover a spectral range from about 70 A to about 300 A. Each telescope will be able to isolate emission line multiplets excited over a narrow temperature range, providing images of diagnostic quality covering structures in the solar atmosphere ranging from T of about 50,000 K to 30,000,000 K. One of the nine UHRXS telescopes is configured as a coronagraph to allow observations to 6 solar radii beyond the solar limb. The paper presents an analysis of the expected sensitivity and resolving power of the UHRXS telescopes, and the diagnostic response of the various UHRXS instruments to structures in the solar atmosphere between 10,000 K and 100,000,000 K.

Walker, Arthur B. C., Jr.↗

A study of the damage tolerance enhancement of carbon/epoxy laminates by utilizing an outer lamina of ultra high molecular weight polyethylene

The damage tolerance of carbon/epoxy was examined when an outer layer of ultra high molecular weight polyethylene (Spectra) material was utilized on the specimen. Four types of 16 ply quasi-isotropic panels, (0,+45,90,-45)s2 were tested. The first contained no Spectra, while the others had one lamina of Spectra placed on either the top (impacted side), bottom or both surfaces of the composite plate. A range of impact energies up to approximately 8.5 Joules (6.3 ft-lbs) was used to inflict damage upon these specimens. Glass/Phenolic honeycomb beams with a core density of 314 N/m3 (2.0 lb/ft3) and 8 ply quasi-isotropic facesheets were also tested for compression-after-impact strength with and without Spectra at impact energies of 1,2,3 and 4 Joules (.74, 1.47, 2.21 and 2.95 ft-lbs). It was observed that the composite plates had little change in damage tolerance due to the Spectra, while the honeycomb panels demonstrated a slight increase in damage tolerance when Spectra was added, the damage tolerance level being more improved at higher impact energies.

Nettles, Alan T.↗

Use of space ultra-vacuum for high quality semiconductor thin film growth

The utilization of space for materials processing is being expanded through a unique concept of epitaxial thin film growth in the ultra-vacuum of low earth orbit (LEO). This condition can be created in the wake of an orbiting space vehicle; and assuming that the vehicle itself does not pertub the environment, vacuum levels of better than 10 exp -14 torr can be attained. This vacuum environment has the capacity of greatly enhancing epitaxial thin film growth and will be the focus of experiments conducted aboard the Wake Shield Facility (WSF) currently being developed by the Space Vacuum Epitaxy Center (SVEC), Industry, and NASA.

Ignatiev, A.↗

Ultra-stable, low phase noise dielectric resonator stabilized oscillators for military and commercial systems

EPSD has designed, fabricated and tested, ultra-stable, low phase noise microwave dielectric resonator oscillators (DRO's) at S, X, Ku, and K-bands, for potential application to high dynamic range and low radar cross section target detection radar systems. The phase noise and the temperature stability surpass commercially available DROs. Low phase noise signals are critical for CW Doppler radars, at both very close-in and large offset frequencies from the carrier. The oscillators were built without any temperature compensation techniques and exhibited a temperature stability of 25 parts per million (ppm) over an extended temperature range. The oscillators are lightweight, small and low cost compared to BAW & SAW oscillators, and can impact commercial systems such as telecommunications, built-in-test equipment, cellular phone and satellite communications systems. The key to obtaining this performance was a high Q factor resonant structure (RS) and careful circuit design techniques. The high Q RS consists of a dielectric resonator (DR) supported by a low loss spacer inside a metal cavity. The S and the X-band resonant structures demonstrated loaded Q values of 20,300 and 12,700, respectively.

Mizan, Muhammad↗

Ultra-high resolution water window x ray microscope optics design and analysis

This project has been focused on the design and analysis of an ultra-high resolution water window soft-x-ray microscope. These activities have been accomplished by completing two tasks contained in the statement of work of this contract. The new results from this work confirm: (1) that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use spherical mirror surfaces and to use graded multilayer coatings on the secondary in order to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater; (2) that surface contour errors will have a significant effect on the optical performance of the microscope and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror; and (3) that tolerance analysis of the spherical Schwarzschild microscope has been shown that the water window operations will require 2-3 times tighter tolerances to achieve a similar performance of operations with 130 A radiation. These results have been included in a manuscript included in the appendix.

Shealy, David L.↗

Sensitivity of LDEF foil analyses using ultra-low background germanium vs. large NaI(Tl) multidimensional spectrometers

Cobalt foils and stainless steel samples were analyzed for induced Co-60 activity with both an ultra-low background germanium gamma-ray spectrometer and with a large NaI(Tl) multidimensional spectrometer, both of which use electronic anticoincidence shielding to reduce background counts resulting from cosmic rays. Aluminum samples were analyzed for Na-22. The results, in addition to the relative sensitivities and precisions afforded by the two methods, are presented.

Reeves, James H.↗

Load test set-up for the Airmass Sunburst Ultra-Light Aircraft

The purpose of this project was to set up, instrument, and test a Sunburst Ultra-Light aircraft. The intentions of the project were that the aircraft would need to be suspended from the test stand, leveled in the stand, the strain gauges tested and wired to the test equipment, and finally, the aircraft would be destroyed to obtain the failing loads. All jobs were completed, except for the destruction of the aircraft. This notebook shows the group's progress as these tasks were completed, and the following section attempts to explain the photographs in the notebook.

Krug, Daniel W.↗