Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Determining the Effects of Neutron Irradiation on the Structural Integrity of Additively Manufactured Heat Exchangers for Very Small Modular Reactor Applications, DOE Final Report (Project # 19-16980)

Auburn University (AU) teamed with the University of Missouri Research Reactor (MURR) and Kansas State University (KSU) to determine how to best use laser-powder bed fusion (L-PBF) additive manufacturing (AM) methods for generating radiation resistant nickel-based superalloys, Inconel alloy 625 and 718, for special purpose reactor (SPR) or very small modular reactor (vSMR) heat-exchangers (HeXs). Compact, conformal, and durable HeXs that are tolerant of extreme environments are needed for supporting the technical maturity of next-generation, portable compact reactors. AM is an enabler for realizing this new wave of HeXs – providing a means to make customizable hot and cold stream architectures with novel flow path geometries (e.g., tortuous channels with non-uniform, asymmetric cross-sections) and reduced layer-to-layer contact resistance (i.e., no separate bonding procedure required). AM further enables a more time/cost efficient means for fabricating SPRs by reducing the number of suppliers required for HeX assembly and allowing for on-site HeX fabrication. The project aim has been to better understand how neutron irradiation affects the microstructure and properties of additively manufactured nickel-based superalloys, to accelerate their safe, reliable use in the modular reactor industry. The major objective was to qualify/quantify the microstructure and microhardness of nickel-based superalloys (including Inconel 718 and 625) additively manufactured via the L-PBF process in the neutron-dosed (irradiated) and non-irradiated states over a course of 3 years. Effects of build orientation during L-PBF and post-AM heat treatments on neutron resistance, microstructure and mechanical properties were also investigated. Neutron damage mechanisms via hardening were characterized. This project combined subject-matter experts in AM, mechanical/microstructure metallic part characterization, and neutron irradiation, as well as unique assets and capabilities at AU and MURR at MU, to ensure project results translated to effectively addressing known gaps in nuclear science and engineering. Parts were fabricated using L-PBF systems readily available at AU. Specimens were then irradiated using MURR facilities; a manipulator equipped hot cell was also used to measure material hardness after dosing. MURR, a 10 MW, light-water nuclear reactor, is the largest, highest powered, highest-flux university owned research reactor in the U.S. The major findings in this project provide evidence that AM can serve as an alternative way to build structural components for future advanced small modular reactors using advanced materials like Inconel 625 (IN625) or Inconel 718 (IN718). After full spectrum neutron irradiation, vertically as-built AM IN625 samples were observed to display better resistance towards radiation-induced-hardening defects relative to traditionally machined metals. A Vickers microhardness tester, using settings of 1 kgf and dwell time of 15 seconds per indentation, was used to measure hardness in this study. The as-built, vertically printed samples experienced 1.2% of radiation hardening vs. 5.25% radiation hardening observed in wrought IN625. Another set of IN625 and IN718 samples were exposed to fast neutron irradiation. It was observed that IN718 showed more resistance towards radiation hardening compared to IN625 samples indicating IN718 had a better performance. Results showed that the IN718 samples experienced less change (-2.5 to 3.24 %) in microhardness. On the other hand, IN625 samples underwent more (0.9 to 7.21%) change in microhardness after fast neutron irradiation. AM IN625 samples were irradiated using an ion (proton) beam in cyclotron. The mechanical properties of AM samples post irradiation were compared with wrought samples. The irradiated region on the samples were tested using nano-hardness indention. It was observed that the beam current and time used in this study generated an annealing effect and thus reduced the hardness of the samples. The sum of the project results provide precious insight into how one may minimize radiation hardening in AM materials while maintaining material property constraints. Results should assist engineers in selecting an appropriate heat treatment for AM nickel-based superalloys for increased radiation resistance. Results should increase confidence levels for adopting AM for building nuclear reactor components which perform the same or better than conventionally manufactured components. Fast neutron irradiation testing provided an accelerated means of obtaining radiation effects without making materials radioactive and difficult to handle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Prospective Study of the Utility of Magnetic Resonance Imaging in Determining Candidacy for Partial Breast Irradiation

Purpose: Retrospective data have demonstrated that breast magnetic resonance imaging (MRI) may change a patient's eligibility for partial breast irradiation (PBI) by identifying multicentric, multifocal, or contralateral disease. The objective of the current study was to prospectively determine the frequency with which MRI identifies occult disease and to establish clinical factors associated with a higher likelihood of MRI prompting changes in PBI eligibility. Methods and Materials: At The University of Chicago, women with breast cancer uniformly undergo MRI in addition to mammography and ultrasonography. From June 2009 through May 2011, all patients were screened prospectively in a multidisciplinary conference for PBI eligibility based on standard imaging, and the impact of MRI on PBI eligibility according to National Surgical Adjuvant Breast and Bowel Project protocol B-39/Radiation Therapy Oncology Group protocol 0413 entry criteria was recorded. Univariable analysis was performed using clinical characteristics in both the prospective cohort and in a separate cohort of retrospectively identified patients. Pooled analysis was used to derive a scoring index predictive of the risk that MRI would identify additional disease. Results: A total of 521 patients were screened for PBI eligibility, and 124 (23.8%) patients were deemed eligible for PBI based on standard imaging. MRI findings changed PBI eligibility in 12.9% of patients. In the pooled univariable analysis, tumor size ≥2 cm on mammography or ultrasonography (P=.02), age <50 years (P=.01), invasive lobular histology (P=.01), and HER-2/neu amplification (P=.01) were associated with a higher likelihood of MRI changing PBI eligibility. A predictive score was generated by summing the number of significant risk factors. Patients with a score of 0, 1, 2, and 3 had changes to eligibility based on MRI findings in 2.8%, 13.2%, 38.1%, and 100%, respectively (P<.0001). Conclusions: MRI identified additional disease in a significant number of patients eligible for PBI, based on standard imaging. Clinical characteristics may be useful in directing implementation of MRI in the staging of PBI candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Permanent, Transparent Anti-Fog Coating for Spacesuit Helmet

Fogging of polycarbonate spacesuit helmets is detrimental to astronaut safety and to mission success. Currently used anti-fogging methods are temporary and require the reapplication of a coating before each use. These temporary solutions have been shown to delaminate during use and have led to eye irritation and temporary blindness during spacewalks. Potential permanent solutions NASA has previously tested lack in durability and are prone to coating damage and delamination during cleaning. Lynntech is leveraging its experience with coating development to fabricate an anti-fog coating with the durability necessary for permanent use, to be applied to polycarbonate. In this SBIR Phase I project, Lynntech has demonstrated the proof of concept by applying our coating to flat polycarbonate and characterized the durability of its anti-fogging properties. Toward this end, Lynntech has developed a breath simulating testbed, exposing coatings to conditions they would experience on the interior of a spacesuit helmet during use. Additionally, Lynntech is developing an application method to uniformly deposit their coating on non-planar objects, such as a prototype spacesuit helmet.

spacesuit↗

Multidisciplinary Aerospace Systems Optimization: Computational AeroSciences (CAS) Project

The report describes a method for performing optimization of a system whose analysis is so expensive that it is impractical to let the optimization code invoke it directly because excessive computational cost and elapsed time might result. In such situation it is imperative to have user control the number of times the analysis is invoked. The reported method achieves that by two techniques in the Design of Experiment category: a uniform dispersal of the trial design points over a n-dimensional hypersphere and a response surface fitting, and the technique of krigging. Analyses of all the trial designs whose number may be set by the user are performed before activation of the optimization code and the results are stored as a data base. That code is then executed and referred to the above data base. Two applications, one of the airborne laser system, and one of an aircraft optimization illustrate the method application.

Kodiyalam, S.↗

Extend an innovative HPC-Compatible Multiple Temporal-spatial Resolution Concurrent Finite Element Modeling Approach to Guide Laser Powder Bed Fusion Additive

Laser power bed fusing (PBF) additive manufacturing is a key enabling technology to manufacture highly complex and integrated automotive structures. However, the geometric complexity of PBF-AM technique also leads to highly non-uniform heating and cooling rate in the manufactured part, which may cause flaw formation and produce excessive and nonuniform residual stresses, which increase quality uncertainties and manufacture issues, leading to increases in cost and energy consumption in the form of rejected parts. In this research project, we developed an innovative Multi-Spatial-Temporal-Resolution Finite Element (MUST-FE) method and completed the corresponding high performance computation (HPC) platform-based in-house code, which enables high accuracy prediction of temperature and residual stress fields for component-scale PBF-AM manufacture in efficient computation time. The MUST-FE model is calibrated and validated with a “2D pad” AlSi10Mg experiments by matching the melt pool shape and dimension, and with a “XY-cross” AlSi10Mg experiment by matching the thermal distortion and residual stress. The innovative multi-resolution and concurrent modeling approach adopted in this code ensures accuracy and computational efficiency, which will enable energy-efficient and high-yield, low-cost manufacturing of optimized, qualifiable automotive structures and contribute towards reaching technical targets outlined in AMO’s Program Plan to develop additive manufacturing systems that deliver consistently reliable parts with predictable properties.

36 MATERIALS SCIENCE↗

Characterization and Alteration of Wettability States of Alaskan Reserviors to Improve Oil Recovery Efficiency (including the within-scope expansion based on Cyclic Water Injection - a pulsed waterflood for Enhanced Oil Recovery)

Numerous early reports on experimental works relating to the role of wettability in various aspects of oil recovery have been published. Early examples of laboratory waterfloods show oil recovery increasing with increasing water-wetness. This result is consistent with the intuitive notion that strong wetting preference of the rock for water and associated strong capillary-imbibition forces gives the most efficient oil displacement. This report examines the effect of wettability on waterflooding and gasflooding processes respectively. Waterflood oil recoveries were examined for the dual cases of uniform and non-uniform wetting conditions. Based on the results of the literature review on effect of wettability and oil recovery, coreflooding experiments were designed to examine the effect of changing water chemistry (salinity) on residual oil saturation. Numerous corefloods were conducted on reservoir rock material from representative formations on the Alaska North Slope (ANS). The corefloods consisted of injecting water (reservoir water and ultra low-salinity ANS lake water) of different salinities in secondary as well as tertiary mode. Additionally, complete reservoir condition corefloods were also conducted using live oil. In all the tests, wettability indices, residual oil saturation, and oil recovery were measured. All results consistently lead to one conclusion; that is, a decrease in injection water salinity causes a reduction in residual oil saturation and a slight increase in water-wetness, both of which are comparable with literature observations. These observations have an intuitive appeal in that water easily imbibes into the core and displaces oil. Therefore, low-salinity waterfloods have the potential for improved oil recovery in the secondary recovery process, and ultra low-salinity ANS lake water is an attractive source of injection water or a source for diluting the high-salinity reservoir water. As part of the within-scope expansion of this project, cyclic water injection tests using high as well as low salinity were also conducted on several representative ANS core samples. These results indicate that less pore volume of water is required to recover the same amount of oil as compared with continuous water injection. Additionally, in cyclic water injection, oil is produced even during the idle time of water injection. It is understood that the injected brine front spreads/smears through the pores and displaces oil out uniformly rather than viscous fingering. The overall benefits of this project include increased oil production from existing Alaskan reservoirs. This conclusion is based on the performed experiments and results obtained on low-salinity water injection (including ANS lake water), vis-a-vis slightly altering the wetting conditions. Similarly, encouraging cyclic water-injection test results indicate that this method can help achieve residual oil saturation earlier than continuous water injection. If proved in field, this would be of great use, as more oil can be recovered through cyclic water injection for the same amount of water injected.

02 PETROLEUM↗

The local dispersion relation for magneto-atmospheric waves

The local dispersion relation for magneto-atmospheric waves is discussed in terms of the linearized theory of waves in a plane-stratified, inviscid, perfectly conducting atmosphere under uniform gravity. The normally used local dispersion relation is demonstrated to not be unique, depending instead on the order of derivation from the fundamental first-order perturbation equations of continuity, momentum, energy, and induction. Furthermore, it is shown that the local dispersion relation predicts that the cutoff frequency decreases with increasing magnetic field strength, while the WKB approximation method projects an increase in the cutoff frequency with increasing magnetic field strength. A new form of the local dispersion relation is developed, and consideration is given to the special case of a global dispersion relation in conditions of an isothermal atmosphere with a horizontal magnetic field.

Thomas, J. H.↗

TH-A-18C-09: Ultra-Fast Monte Carlo Simulation for Cone Beam CT Imaging of Brain Trauma

Purpose: Application of cone-beam CT (CBCT) to low-contrast soft tissue imaging, such as in detection of traumatic brain injury, is challenged by high levels of scatter. A fast, accurate scatter correction method based on Monte Carlo (MC) estimation is developed for application in high-quality CBCT imaging of acute brain injury. Methods: The correction involves MC scatter estimation executed on an NVIDIA GTX 780 GPU (MC-GPU), with baseline simulation speed of ~1e7 photons/sec. MC-GPU is accelerated by a novel, GPU-optimized implementation of variance reduction (VR) techniques (forced detection and photon splitting). The number of simulated tracks and projections is reduced for additional speed-up. Residual noise is removed and the missing scatter projections are estimated via kernel smoothing (KS) in projection plane and across gantry angles. The method is assessed using CBCT images of a head phantom presenting a realistic simulation of fresh intracranial hemorrhage (100 kVp, 180 mAs, 720 projections, source-detector distance 700 mm, source-axis distance 480 mm). Results: For a fixed run-time of ~1 sec/projection, GPU-optimized VR reduces the noise in MC-GPU scatter estimates by a factor of 4. For scatter correction, MC-GPU with VR is executed with 4-fold angular downsampling and 1e5 photons/projection, yielding 3.5 minute run-time per scan, and de-noised with optimized KS. Corrected CBCT images demonstrate uniformity improvement of 18 HU and contrast improvement of 26 HU compared to no correction, and a 52% increase in contrast-tonoise ratio in simulated hemorrhage compared to “oracle” constant fraction correction. Conclusion: Acceleration of MC-GPU achieved through GPU-optimized variance reduction and kernel smoothing yields an efficient (<5 min/scan) and accurate scatter correction that does not rely on additional hardware or simplifying assumptions about the scatter distribution. The method is undergoing implementation in a novel CBCT dedicated to brain trauma imaging at the point of care in sports and military applications. Research grant from Carestream Health. JY is an employee of Carestream Health.

60 APPLIED LIFE SCIENCES↗

Production of Seamless Superconducting Radio Frequency Cavities from Ultra-fine Grained Niobium, Phase II Final Report

The positron and electron linacs of the International Linear Collider (ILC) will require over 14,000, nine-cell, one meter length, superconducting radio frequency (SRF) cavities [ILC Reference Design Report, 2007]. Manufacturing on this scale will benefit from more efficient fabrication methods. The current methods of fabricating SRF cavities involve deep drawing of the halves of each of the elliptical cells and joining them by high-vacuum, electron beam welding, with at least 19 circumferential welds per cavity. The welding is costly and has undesirable effects on the cavity surfaces, including grain-scale surface roughening at the weld seams. Hydroforming of seamless tubes avoids welding, but hydroforming of coarse-grained seamless tubes results in strain-induced surface roughening. Surface roughness limits accelerating fields, because asperities prematurely exceed the critical magnetic field and become normal conducting. This project explored the technical and economic feasibility of an improved processing method for seamless tubes for hydroforming. Severe deformation of bulk material was first used to produce a fine structure, followed by extrusion and flow-forming methods of tube making. Extrusion of the randomly oriented, fine-grained bulk material proceeded under largely steady-state conditions, and resulted in a uniform structure, which was found to be finer and more crystallographically random than standard (high purity) RRR niobium sheet metal. A 165 mm diameter billet of RRR grade niobium was processed into five, 150 mm I.D. tubes, each over 1.8 m in length, to meet the dimensions used by the DESY ILC hydroforming machine. Mechanical properties met specifications. Costs of prototype tube production were approximately twice the price of RRR niobium sheet, and are expected to be comparable with economies of scale. Hydroforming and superconducting testing will be pursued in subsequent collaborations with DESY and Fermilab. SRF Cavities are used to construct particle accelerators for high-energy physics research, as well as for lower energy particle accelerators, and Free Electron Lasers. These machines have applications in the fields of basic science, industrial processing, medical diagnostics, pharmaceutical research and weapons systems. The scientific community and the general public will benefit from the implementation of this technology since lower production costs will increase the availability of SRF particle accelerators.

36 MATERIALS SCIENCE↗

Validating a large geophysical data set: Experiences with satellite-derived cloud parameters

We are validating the global cloud parameters derived from the satellite-borne HIRS2 and MSU atmospheric sounding instrument measurements, and are using the analysis of these data as one prototype for studying large geophysical data sets in general. The HIRS2/MSU data set contains a total of 40 physical parameters, filling 25 MB/day; raw HIRS2/MSU data are available for a period exceeding 10 years. Validation involves developing a quantitative sense for the physical meaning of the derived parameters over the range of environmental conditions sampled. This is accomplished by comparing the spatial and temporal distributions of the derived quantities with similar measurements made using other techniques, and with model results. The data handling needed for this work is possible only with the help of a suite of interactive graphical and numerical analysis tools. Level 3 (gridded) data is the common form in which large data sets of this type are distributed for scientific analysis. We find that Level 3 data is inadequate for the data comparisons required for validation. Level 2 data (individual measurements in geophysical units) is needed. A sampling problem arises when individual measurements, which are not uniformly distributed in space or time, are used for the comparisons. Standard 'interpolation' methods involve fitting the measurements for each data set to surfaces, which are then compared. We are experimenting with formal criteria for selecting geographical regions, based upon the spatial frequency and variability of measurements, that allow us to quantify the uncertainty due to sampling. As part of this project, we are also dealing with ways to keep track of constraints placed on the output by assumptions made in the computer code. The need to work with Level 2 data introduces a number of other data handling issues, such as accessing data files across machine types, meeting large data storage requirements, accessing other validated data sets, processing speed and throughput for interactive graphical work, and problems relating to graphical interfaces.

Kahn, Ralph↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full wave simulation of waves in ECRIS plasmas based on the finite element method

This paper describes the modeling and the full wave numerical simulation of electromagnetic waves propagation and absorption in an anisotropic magnetized plasma filling the resonant cavity of an electron cyclotron resonance ion source (ECRIS). The model assumes inhomogeneous, dispersive and tensorial constitutive relations. Maxwell's equations are solved by the finite element method (FEM), using the COMSOL Multiphysics{sup ®} suite. All the relevant details have been considered in the model, including the non uniform external magnetostatic field used for plasma confinement, the local electron density profile resulting in the full-3D non uniform magnetized plasma complex dielectric tensor. The more accurate plasma simulations clearly show the importance of cavity effect on wave propagation and the effects of a resonant surface. These studies are the pillars for an improved ECRIS plasma modeling, that is mandatory to optimize the ion source output (beam intensity distribution and charge state, especially). Any new project concerning the advanced ECRIS design will take benefit by an adequate modeling of self-consistent wave absorption simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-fast Boriding for Improved Energy Efficiency and Reduced Emissions in Materials Processing Industries (Final Report)

High-temperature treatment processes (such as nitriding, carburizing, and boronizing) are well-established and used widely by numerous industrial sectors to achieve superior mechanical and tribological properties on all kinds of engineering components made out of ferrous materials. Unfortunately, these traditional processes are very slow and energy intensive, and they produce large amounts of CO 2 emissions and liquid/solid wastes to deal with during and after each process run. From economic and environmental points of views, it is highly desirable to develop and implement novel surface treatment technologies that are quick, cheap, clean, and energy efficient. The main objective of this project was to develop an industrial-scale ultra-fast boriding process that realizes all of these desirable attributes. The other objectives of the project were to demonstrate the superior performance, properties, and durability of borided surfaces under relevant test conditions and to transfer optimized technology to industry for large-scale practice. Major research activities included process design, modeling, product optimization, and scale-up. This project has achieved all of its stated objectives, and the industrial-scale boriding process has been successfully transferred to industry. Specifically, all of the original tasks have been completed, and the milestones have been met by scaling up from a small proof-of-concept system (which could only handle about 0.25 kg melt) to a commercial-scale boriding unit that can handle up to 4,000 kg melt. Mechanical and tribological testing of borided test samples and industrial parts has also been carried out, and their superior performance over a broad range of test conditions has been validated. With the large-scale, ultra-fast boriding process, we could achieve thick, hard, and uniform boride layers on all kinds of steel components, even after only 5 min of treatment time. We could also attain excellent uniformity in thickness over the entire exposed surfaces — even in the very sharp corners or interior sections of odd-shaped workpieces. Boriding of numerous nonferrous materials was also demonstrated, and thick boride layers (up to 300 µm in thickness) were achieved on their outer surfaces. With the use of a large-scale boriding unit at Argonne National Laboratory, our research team has successfully treated large numbers of industrial components in a batch-to-batch operation without creating any in-house gaseous emissions or producing solid and/or liquid wastes. With the use of this large unit, our team achieved surface hardness values of 15 to 45 GPa, depending on the type of metal or alloy being treated. The thick boride layers attained on steel components consisted of FeB, Fe 2 B, and Fe 3 B phases, and their hardness values ranged from 16 to 22 GPa. Layers consisting of Fe 2 B phase alone are also possible with this process, and in the case of nonferrous materials. Overall, because of the much superior property and performance improvements in treated products, much lower energy consumption, and nearly zero environmental waste and emissions, the demonstrated boriding technology may find broad applications in many cross-cutting industries. Mechanical wear, abrasion, erosion, corrosion, and scuffing are often life-limiting factors in mechanical systems that are used in manufacturing, transportation, aerospace, agricultural, earth-moving, and mining equipment; but the machine components treated by ultra-fast boriding can effectively prevent such degradations. In this project, the ultra-fast boriding was proven to be most ideal for the treatment of iron and many other ferrous alloys, like stainless steel. We have shown through our experimental studies that our method can also be used for the treatment of many nonferrous metals and alloys. In the case of superalloys and Ni 3 Al intermetallic materials, more than a 300-µm thick boride layer can be achieved with our boriding furnace within 15 to 30 min (which results in five times the hardness of the base materials). Pre-carburized steels and nonferrous alloys can also be treated by the new boriding technique. Overall, very thick (more than a quarter millimeter) and hard surface layers produced by ultra-fast boriding are expected to have a positive impact on the performance and durability of all types of machine components that are subject to corrosive, erosive, abrasive, and adhesive wear. Since the focus of our project was primarily on the large-scale boriding of ferrous materials, in this report, we will broadly cover the results from various ferrous materials that were used in our experiments. Another transformational feature of ultra-fast boriding is that it does not create any greenhouse gas emissions or solid and/or liquid wastes to deal with during or after the treatment; hence, it is an ultra-green technology (no need for expensive waste disposal and/or treatment facilities). It may eliminate the use of natural gas and other carbon-based fuels as the primary energy source in the heat treatment industry (which is the most common practice at present), thus, minimizing the CO 2 , NO x , CO, and SO x emissions that are generated in large quantities by current heat treatment practices. The main ingredient used during boriding is borax, which is a natural mineral. Our demonstrated and scaled-up technology can now be used in a wide range of manufacturing and transportation applications. It can deliver thick and uniform boride layers of more than 200 µm in steels, if needed, over the entire exposed surfaces — even in the very sharp corners or interior sections of workpieces (which are typical of gears, tools, pipes, and other components). Beneath the distinct boride layers is an equally-thick boron diffusion layer or zone, which is comparable to the diffusion zones achieved by carburizing and nitriding processes. In the cases of traditional boriding, nitriding, and/or carburizing methods, achieving such layer thickness and case depths would have taken several hours, and these surfaces would not have achieved the same levels of hardness and other desirable properties as they do with ultra-fast boriding. Some of the key stakeholders of ultra-fast boriding technology include companies that are active in heat-treatment, thermal-diffusion, and hard-coating processes; metal-forming, machining, and other manufacturing processes; and technologies related to transportation (including original equipment manufacturers for autos), mining and oil exploration, agricultural and heavy equipment. Bodycote Thermal Processing was the cost-sharing industrial partner and licensee in this project. They also provided test components and technical and commercial information pertaining to industrial components that are most suitable for ultra-fast boriding. Bodycote also coordinated some of the field tests and metallurgical examinations. Overall, ultra-fast boriding is a transformational technology that can complement, if not replace, many of the energy- and carbon-intensive surface treatment processes that are in use today, such as conventional boriding, carburizing, nitriding, carbo-nitriding, and physical and chemical vapor deposition. In our project, the developed technology was scaled-up and proven to be an ultra-green, ultra-efficient process that can drastically reduce costs, increase productivity, and improve the performance and reliability of machine components used in cross-cutting industrial applications.

Erdemir, Ali↗

Montage electron tomography of vitrified specimens

Cryo-electron tomography provides detailed views of macromolecules in situ. However, imaging a large field of view to provide more cellular context requires reducing magnification during data collection, which in turn restricts the resolution. To circumvent this trade-off between field of view and resolution, we have developed a montage data collection scheme that uniformly distributes the dose throughout the specimen. In this approach, sets of slightly overlapping circular tiles are collected at high magnification and stitched to form a composite projection image at each tilt angle. These montage tilt-series are then reconstructed into massive tomograms with a small pixel size but a large field of view. For proof-of-principle, we applied this method to the thin edge of HeLa cells. Thon rings to better than 10 Å were detected in the montaged tilt-series, and diverse cellular features were observed in the resulting tomograms. These results indicate that the additional dose required by this technique is not prohibitive to performing structural analysis to intermediate resolution across a large field of view. We anticipate that montage tomography will prove particularly useful for lamellae, increase the likelihood of imaging rare cellular events, and facilitate visual proteomics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-174: Adaptive PET-Based Dose Painting with Tomotherapy

Purpose: PET imaging can be converted into dose prescription directly. Due to the variability of the intensity of PET the image, PET prescription maybe superior over uniform dose prescription. Furthermore, unlike the case in image reconstruction of not knowing the image solution in advance, the prescribed dose is known from a PET image a priori. Therefore, optimum beam orientations are derivable. Methods: We can assume the PET image to be the prescribed dose and invert it to determine the energy fluence. The same method used to reconstruct tissue images from projections could be used to solve the inverse problem of determining beam orientations and modulation patterns from a dose prescription [10]. Unlike standard tomographic reconstruction of images from measured projection profiles, the inversion of the prescribed dose results in photon fluence which may be negative and therefore unphysical. Two-dimensional modulated beams can be modelled in terms of the attenuated or exponential radon transform of the prescribed dose function (assumed to be the PET image in this case), an application of a Ram-Lak filter, and inversion by backprojection. Unlike the case in PET processing, however, the filtered beam obtained from the inversion represents a physical photon fluence. Therefore, a positivity constraint for the fluence (setting negative fluence to zero) must be applied (Brahme et al 1982, Bortfeld et al 1990) Results: Truncating the negative profiles from the PET data results in an approximation of the derivable energy fluence. Backprojection of the deliverable fluence is an approximation of the dose delivered. The deliverable dose is comparable to the original PET image and is similar to the PET image. Conclusion: It is possible to use the PET data or image as a direct indicator of deliverable fluence for cylindrical radiotherapy systems such as TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Bowtie filters for dedicated breast CT: Theory and computational implementation

Purpose: To design bowtie filters with improved properties for dedicated breast CT to improve image quality and reduce dose to the patient. Methods: The authors present three different bowtie filters designed for a cylindrical 14-cm diameter phantom with a uniform composition of 40/60 breast tissue, which vary in their design objectives and performance improvements. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. Bowtie design #3 eliminates the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. All three designs are obtained using analytical computational methods and linear attenuation coefficients. Thus, the designs do not take into account the effects of scatter. The authors considered this to be a reasonable approach to the filter design problem since the use of Monte Carlo methods would have been computationally intensive. The filter profiles for a cone-angle of 0° were used for the entire length of each filter because the differences between those profiles and the correct cone-beam profiles for the cone angles in our system are very small, and the constant profiles allowed construction of the filters with the facilities available to us. For evaluation of the filters, we used Monte Carlo simulation techniques and the full cone-beam geometry. Images were generated with and without each bowtie filter to analyze the effect on dose distribution, noise uniformity, and contrast-to-noise ratio (CNR) homogeneity. Line profiles through the reconstructed images generated from the simulated projection images were also used as validation for the filter designs. Results: Examples of the three designs are presented. Initial verification of performance of the designs was done using analytical computations of HVL, intensity, and effective attenuation coefficient behind the phantom as a function of fan-angle with a cone-angle of 0°. The performance of the designs depends only weakly on incident spectrum and tissue composition. For all designs, the dynamic range requirement on the detector was reduced compared to the no-bowtie-filter case. Further verification of the filter designs was achieved through analysis of reconstructed images from simulations. Simulation data also showed that the use of our bowtie filters can reduce peripheral dose to the breast by 61% and provide uniform noise and CNR distributions. The bowtie filter design concepts validated in this work were then used to create a computational realization of a 3D anthropomorphic bowtie filter capable of achieving a constant effective attenuation coefficient behind the entire field-of-view of an anthropomorphic breast phantom. Conclusions: Three different bowtie filter designs that vary in performance improvements were described and evaluated using computational and simulation techniques. Results indicate that the designs are robust against variations in breast diameter, breast composition, and tube voltage, and that the use of these filters can reduce patient dose and improve image quality compared to the no-bowtie-filter case.

60 APPLIED LIFE SCIENCES↗

Daily Online Cone Beam Computed Tomography to Assess Interfractional Motion in Patients With Intact Cervical Cancer

Purpose: To quantify interfraction motion in patients with intact cervical cancer and assess implications for clinical target volume (CTV) coverage and required planning margins. Methods and Materials: We analyzed 10 patients undergoing external beam radiotherapy using online cone beam computed tomography (CBCT) before each fraction. CTVs were contoured on the planning CT and on each CBCT. Each CBCT was rigidly registered to the planning CT with respect to bony anatomy. The CTV from each CBCT was projected onto the planning CT and compared to the CTV from the planning CT. Uniform three-dimensional expansions were applied to the planning CTV to assess required planning margins. For each fraction, the minimum margin required to encompass the CTV was calculated, and the volume of CTV (on the CBCT) encompassed by the PTV was determined as a function of margin size. Results: A uniform CTV planning treatment volume margin of 15 mm would have failed to encompass the CTV in 32% of fractions. The mean volume of CTV missed, however, was small (4 cc). The mean planning margin (across patients and fractions) required to encompass the CTV was 15 mm. Variation in margin estimates was high, with interpatient variation being the predominant component. Increased rectal volume was associated with posterior (p < 0.0001) and superior (p = 0.0004) shifts in the CTV, whereas increased bladder volume was associated with superior shifts (p < 0.0001). Conclusions: Interfraction motion results in a high probability of missing the CTV using conventional planning margins, but the volume of CTV missed is small. Adaptive radiotherapy approaches are needed to improve treatment accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗