Search NASA⌕ Search

SEARCH · Search NASA

Results for “unitized”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

gRASPA

GPU Monte Carlo Simulation Code with a taste of RASPA We present enhancements in Monte Carlo simulation speed and functionality within an open-source code, gRASPA, which uses graphical processing units (GPUs) to achieve significant performance improvements compared to serial, CPU implementations of Monte Carlo. The code supports a wide range of Monte Carlo simulations, including canonical ensemble (NVT), grand canonical, NVT Gibbs, Widom test particle insertions, and continuous-fractional component Monte Carlo. Implementation of grand canonical transition matrix Monte Carlo (GC-TMMC) and a novel feature to allow different moves for the different components of metal-organic framework (MOF) structures exemplify the capabilities of gRASPA for precise free energy calculations and enhanced adsorption studies, respectively. The introduction of a High-Throughput Computing (HTC) mode permits many Monte Carlo simulations on a single GPU device for accelerated materials discovery. The code can incorporate machine learning (ML) potentials. The open-source nature of gRASPA promotes reproducibility and openness in science, and users may add features to the code and optimize it for their own purposes. The code is written in CUDA/C++ and SYCL/C++ to support different GPU vendors. The gRASPA code is publicly available at https://github.com/snurr-group/gRASPA.

Li, Zhao [Purdue/Northwestern/Notre Dame Universit↗

Leaf-level physiological strategies related to productivity and plasticity of Populus in the Southeastern United States

Introduction: Populus and its hybrids are attractive bioenergy crops and the southeastern United States has broad ability to supply bioenergy markets with woody biomass. Breeding and hybridization have led to superior eastern cottonwood (Populus deltoides W. Bartram ex Marshall) and hybrid poplars adapted to a wide variety of site types not suited for agricultural production. In order to maximize productivity and minimize inputs, genotypes need to efficiently use available site resources and tolerate environmental stresses. In addition, we need to determine plasticity of traits and their coordination across sites to select traits that will broadly characterize genotypes. Therefore, our study objectives were to determine (1) which leaf traits were correlated with growth, (2) if traits and genotypes exhibited significant plasticity across sites, and (3) how traits were coordinated within and across sites and Populus taxa. Methods: We measured trees at two sites in northeastern Mississippi, United States: one upland and one alluvial terrace site. Genotypes included eastern cottonwoods as well as F 1 crosses of eastern cottonwood and P. maximowiczii (Henry), P. nigra (L.) and P. trichocarpa (Torr. & Gray). Results: We found that sites differed in which leaf traits were correlated with productivity; with water use efficiency specifically being positively correlated with growth at an alluvial terrace site, but negatively correlated with growth at an upland site. Tree height growth, leaf isotope composition (δ 13 C and δ 15 N), as well as leaf mass per area (LMA) exhibited the least plasticity across sites, while physiological gas exchange parameters and leaf nitrogen concentration exhibited the highest plasticity. Broadly across taxa, leaf carbon isotope ratios were correlated with intrinsic water use efficiency, and stomatal conductance was positively correlated with photosynthetic nitrogen use efficiency across sites, while leaf nitrogen isotope ratios exhibited contrasting relationships with leaf nitrogen concentration. Discussion: Overall, these results allow us to refine selections of productive genotypes based on site conditions and site-specific relationships with physiological parameters to better match Populus taxa with sites and landowner objectives.

bioenergy feedstocks↗

Integration of GOES Data for Solar Resource Assessment of the Contiguous United States

The National Solar Radiation Database (NSRDB), produced by the National Laboratory of the Rockies (NLR), provides high-resolution solar resource data for the contiguous United States (CONUS) using Geostationary Operational Environmental Satellite (GOES) East and West observations. This study evaluates the integration of multi-satellite data within the GOES-East/West overlap regions, where conventional longitude-based selection methods often produce an artificial boundary seam. Our results demonstrate that an advanced blending algorithm, which incorporates sun-satellite scattering angles and satellite viewing zenith angles, improves NSRDB accuracy and creates a spatially continuous dataset. Validation against ground-based irradiance measurements reveals reductions in both percentage error (PE) and normalized Root Mean Square Error (nRMSE), particularly in the central United States. The dynamical integration of multi-satellite data provides a robust foundation for more precise modeling of solar resource and improved spatiotemporal analysis of solar ramp across the CONUS.

14 SOLAR ENERGY↗

Modeling Flexible Generator Operating Regions via Chance- constrained Stochastic Unit Commitment

Here, we introduce a novel chance-constrained stochastic unit commitment model to address uncertainty in renewables' production uncertainty in power systems operation. For most thermal generators,underlying technical constraints that are universally treated as "hard" by deterministic unit commitment models are in fact based on engineering judgments, such that system operators can periodically request operation outside these limits in non-nominal situations, e.g., to ensure reliability. We incorporate this practical consideration into a chance-constrained stochastic unit commitment model, specifically by in-frequently allowing minor deviations from the minimum and maximum thermal generator power output levels. We demonstrate that an extensive form of our model is computationally tractable for medium-sized power systems given modest numbers of scenarios for renewables' production. We show that the model is able to potentially save significant annual production costs by allowing infrequent and controlled violation of the traditionally hard bounds imposed on thermal generator production limits. Finally, we conduct a sensitivity analysis of optimal solutions to our model under two restricted regimes and observe similar qualitative results.

42 ENGINEERING↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid data-driven and model-based approach for computationally efficient stochastic unit commitment and economic dispatch under wind and solar uncertainty

Stochastic unit commitment (UC) and economic dispatch (ED) are imperative in dealing with uncertainty in renewable forecast for power system operation and planning such that the overall expected production cost is minimized over the planning horizon. However, accurate calculation of the expected production cost requires assessment of a very large number of different scenarios of uncertain renewable resources, such as solar and wind, which is practically infeasible to simulate in real time. This article proposes a hybrid datadriven and physics-based model-predictive paradigm to efficiently solve for stochastic unit commitment and economic dispatch considering uncertainty in wind and solar power forecasts. Here, the novelty of the approach lies in decoupling the production cost estimation from the unit commitment and economic dispatch optimization problems under uncertainty without compromising on the fidelity of the solutions. A data-driven machine learning model is first developed to predict the mean optimal production cost. A physics-based inverse problem is then solved to get the stochastic UC and ED profiles from the expected cost. The presented approach considers, for the first time, solar uncertainty in UC/ED determination and enables efficient and accurate propagation of wind and solar uncertainty to estimate the statistics of the production cost. The effectiveness of the developed approach is demonstrated systematically on a stylized RTS-GMLC single-node system. The overall framework predicts the expected cost 62.5% more accurately than the existing state-of-the-art, on unforeseen days during the entire year, and yields, for the first time, the associated physically consistent UC and ED profiles. The solutions are also shown to be flexible in providing adequate daily reserves to address any statistical deviations from probabilistic power forecasts. The computational time associated with the presented method is only about 10 s compared to over 24 h needed for a conventional stochastic UC/ED determination under uncertainty on an Intel Core i9 processor with 32 GB of RAM.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Interfacial Unit-Dependent Catalytic Activity for CO Oxidation over Cerium Oxysulfate Cluster Assemblies

Atomically precise cerium oxo clusters offer a platform to investigate structure–property relationships that are much more complex in the ill-defined bulk material cerium dioxide. We investigated the activity of the MCe 70 torus family (M = Cd, Ce, Co, Cu, Fe, Ni, and Zn), a family of discrete oxysulfate-based Ce 70 rings linked by monomeric cation units, for CO oxidation. CuCe 70 emerged as the best performing MCe 70 catalyst among those tested, prompting our exploration of the role of the interfacial unit on catalytic activity. Temperature-programmed reduction (TPR) studies of the catalysts indicated a lower temperature reduction in CuCe 70 as compared to CeCe 70 . In situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) indicated that CuCe 70 exhibited a faster formation of Ce 3+ and contained CO bridging sites absent in CeCe 70 . Isothermal CO adsorption measurements demonstrated a greater uptake of CO by CuCe 70 as compared to CeCe 70 . The calculated energies for the formation of a single oxygen defect in the structure significantly decreased with the presence of Cu at the linkage site as opposed to Ce. Furthermore, this study revealed that atomic-level changes in the interfacial unit can change the reducibility, CO binding/uptake, and oxygen vacancy defect formation energetics in the MCe 70 family to thus tune their catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Widespread Wildfires Over the Western United States in 2020 Linked to Emissions Reductions During COVID-19

Widespread wildfires struck western United States in 2020, directly damaging properties and threatening human lives. Meanwhile, the COVID-19 pandemic rapidly spread across the globe in 2020, which disrupted human activities and resulted in substantial reductions in anthropogenic emissions. Here, we investigate the effects of the emissions reductions of aerosols, precursors, and greenhouse gases during the pandemic on wildfire weather conditions in 2020 over western United States by using an earth system model together with observational data. We show that the COVID-19 emissions reductions in model experiments increased surface air temperature and decreased precipitation and relative humidity due to a weakened moisture transport, which explains 10-40% of the observed increase in the risk of wildfires over western United States in 2020. In conclusion, this study suggests that COVID-19-related abrupt emissions reductions have an unexpected influence on wildfires, highlighting a different but important role of human activities in affecting wildfire risks.

54 ENVIRONMENTAL SCIENCES↗

Cropland abandonment between 1986 and 2018 across the United States: spatiotemporal patterns and current land uses

Knowing where and when croplands have been abandoned or otherwise removed from cultivation is fundamental to evaluating future uses of these areas, e.g. as sites for ecological restoration, recultivation, bioenergy production, or other uses. However, large uncertainties remain about the location and time of cropland abandonment and how this process and the availability of associated lands vary spatially and temporally across the United States. Here, we present a nationwide, 30 m resolution map of croplands abandoned throughout the period of 1986–2018 for the conterminous United States (CONUS). We mapped the location and time of abandonment from annual cropland layers we created in Google Earth Engine from 30 m resolution Landsat imagery using an automated classification method and training data from the U.S. Department of Agriculture Cropland Data Layer. Our abandonment map has overall accuracies of 0.91 and 0.65 for the location and time of abandonment, respectively. From 1986 to 2018, 12.3 (±2.87) million hectares (Mha) of croplands were abandoned across CONUS, with areas of greatest change over the Ogallala Aquifer, the southern Mississippi Alluvial Plain, the Atlantic Coast, North Dakota, northern Montana, and eastern Washington state. The average annual nationwide abandoned area across our study period was 0.51 Mha per year. Annual abandonment peaked between 1997 and 1999 at a rate of 0.63 Mha year –1 , followed by a continuous decrease to 0.41 Mha year –1 in 2009–2011. Among the abandoned croplands, 53% (6.5 Mha) changed to grassland and pasture, 18.6% (2.28 Mha) to shrubland and forest, 8.4% (1.03 Mha) to wetlands, and 4.6% (0.56 Mha) to non-vegetated lands. Of the areas that we mapped as abandoned, 19.6% (2.41 Mha) were enrolled in the Conservation Reserve Program as of 2020. Our new map highlights the long-term dynamic nature of agricultural land use and its relation to various competitive pressures and land use policies in the United States.

54 ENVIRONMENTAL SCIENCES↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

No evidence of Bartonella infections in host-seeking Ixodes scapularis and Ixodes pacificus ticks in the United States

Background. Bartonella spp. infect a variety of vertebrates throughout the world, with generally high prevalence. Several Bartonella spp. are known to cause diverse clinical manifestations in humans and have been recognized as emerging pathogens. These bacteria are mainly transmitted by blood-sucking arthropods, such as fleas and lice. The role of ticks in the transmission of Bartonella spp. is unclear. Methods. A recently developed quadruplex polymerase chain reaction (PCR) amplicon next-generation sequencing approach that targets Bartonella-specific fragments on gltA, ssrA, rpoB, and groEL was applied to test host-seeking Ixodes scapularis ticks (n=1641; consisting of 886 nymphs and 755 adults) collected in 23 states of the eastern half of the United States and Ixodes pacificus ticks (n=966; all nymphs) collected in California in the western United States for the presence of Bartonella DNA. These species were selected because they are common human biters and serve as vectors of pathogens causing the greatest number of vector-borne diseases in the United States. Results. No Bartonella DNA was detected in any of the ticks tested by any target. Conclusions. Owing to the lack of Bartonella detection in a large number of host-seeking Ixodes spp. ticks tested across a broad geographical region, our results strongly suggest that I. scapularis and I. pacificus are unlikely to contribute more than minimally, if at all, to the transmission of Bartonella spp.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-Unit Dwelling Plug-in EV Charging Innovation Pilots (Final Report)

Nearly one-third of residences in the U.S. are multi-unit dwellings (MUDs), e.g., apartments and condominiums, and MUDs with five or more units account for approximately 45% of rental households. While 80% of EV charging takes place at home, less than 5% of home charging takes place at MUDs. With public electric vehicle (EV) charging still underdeveloped, lack of access to reliable home charging is a major barrier to EV adoption for MUD residents. Challenges to siting electric vehicle supply equipment (EVSE) at MUDs include the high upfront cost of EVSE installation, physical and/or electrical infrastructure constraints, a lack of clear incentives for property managers to invest in installing EV charging for tenants, and a limited number of EV charging service providers that offer solutions adapted to the unique needs of MUDs. Through award DE-EE0008473 from the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE), Center for Sustainable Energy (CSE), Energetics, and Forth, along with a diverse team of partners, led a three-year project to address barriers to EV charging at MUDs by developing an online toolkit geared toward residents, homeowner associations (HOAs), and property managers. The project, referred to as Vehicle Charging Innovations – Multi-Unit Dwellings (VCI-MUD project), engaged stakeholders across the country to identify real and perceived barriers to EV charging at MUDs and explored innovative technologies that attempt to alleviate the identified barriers. Over the course of three and a half years, the project conducted 60 interviews with industry stakeholders, compiled findings in an easy-to-use toolkit, and disseminated the toolkit across national, regional, state, and local channels. Key findings and outcomes of the VCI-MUD project include: Identifying six primary barriers to the installation of EV charging at MUDs; Developing five fact sheets and eight case studies highlighting innovative charging solutions to address barriers, including real-world operational and financial data; Developing a user-friendly, online empowerment toolkit with five important points for “making your pitch” to support EV charging to assist residents, property managers, building managers, and HOAs explore options for MUD charging. The VCI-MUD online toolkit was designed with replicability in mind. It includes general tools and guides to evaluate EV charging demand, gauge readiness for EV charging installation, and develop actionable plans. The fact sheets and case studies highlight the diversity of emerging MUD EV charging solutions, featuring different geographic and structural installation scenarios and providing interested parties with a menu of options, rather than prescribing a one-size-fits-all solution. The following resources are included in the toolkit to provide MUD stakeholders with all the information needed to navigate EV charging installation at their MUD location: Empowerment Toolkit – Easy-to-read FAQ overview, stakeholder roles and responsibilities, and additional resources for MUD EV charging installations; Charging Basics – Glossary of terms and descriptions of charging features, installation and operating expenses; EV Charging Survey Templates – Resident-to-Resident, Property Manager-to-Resident and HOA-to-Resident template letters with pre-populated template questions; Technology Selection Tool – Charging barrier fact sheets and case study examples; Installation Checklist – Submittal document requirements for EVSE installations; MUD Building Self-Evaluation Survey – Self-guided evaluation of potential barriers to EV charging installation at MUD locations; Curbside Resources – Case studies and fact sheets for curbside charging options; Find a Certified Electrician – Approved list of certified EV charging installers; “Right-to-Charge” State Legal References – Legal requirements for charging equipment at MUD locations. The online toolkit was promoted extensively in the final six months of the project and will continue to be disseminated by the Clean Cities Coalitions and other partners after the end of the VCI-MUD project to encourage, support, and demonstrate viable solutions for vehicle charging infrastructure in MUDs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Updated Life Cycle Assessment of Utility-Scale Solar Photovoltaic Systems Installed in the United States

Given the high deployment targets for solar photovoltaics (PV) needed to meet U.S. decarbonization goals, and the limited carbon budget remaining to limit global temperature rise, accurate accounting of the energy-use and greenhouse-gas emissions over the life-cycle of PV systems is needed. In the United States, most PV systems are large utility-scale systems which use single-axis trackers and central inverters, which are not commonly examined in existing life-cycle assessment (LCA) literature. In this study, we present a cradle-to-grave LCA of a typical silicon U.S. utility PV (UPV) installation which is consistent with the utility system features documented in the annual NREL PV system cost benchmark reports. We analyze and present results for four main metrics: cumulative energy demand (CED), greenhouse gas (GHG) emissions, energy payback time (EPBT), and carbon payback time (CPBT). We consider six primary manufacturing options: three based on an imported PV module supply chain (comparing low-carbon imports, high-carbon imports, and average imports), and three based on a potential domestic PV module supply chain (comparing low-carbon U.S. regions, high-carbon U.S. regions, and average U.S. regions). These manufacturing options were then paired with installation locations to create six main cases: low-carbon options were installed in Phoenix (Arizona), high-carbon options were installed in Seattle (Washington), and average options were installed in Fredonia (Kansas). These locations were selected to represent a range of irradiance and grid mixes in the United States, in order to illustrate the likely range of EPBTs and CPBTs possible across the United States. For all six cases, a sensitivity analysis for end-of-life (EOL) handling was explored to capture current and future management options: landfilling, partial recycling, and high-quality recycling. For the purposes of this report, the benchmark system was defined to use an average imported supply chain with partial recycling, installed in Fredonia (Kansas). CED results show ratios at or below 0.1 MJ oil-eq /MJgenerated which demonstrates efficient use of primary energy resources (below a 1:1 ratio), and represents a slight improvement over previous results in literature. GHG emissions per kWh range from 10-36 g CO 2 e, which are consistent with or lower than previous results published by NREL and IEA-PVPS. We use a graphical approach for calculating EPBT and CPBT in this report, which improves upon methods typically used in literature by accounting for non-linearity and avoiding data quality issues associated with long-term projections. EPBT was determined to vary from 0.5 to 1.2 years, with a benchmark EPBT of 0.6 years; CPBT was shown to vary from 0.8 to 20 years, with benchmark CPBT of 2.1 years, which is lower than other estimates from recent literature (typically >2 years).

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Advanced Rooftop Unit Control

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. Advanced rooftop unit controls (ARC) generally consist of a supply fan VFD, and controls to implement demand controlled ventilation (DCV) and air-side economizing, as a retrofit to improve energy efficiency of existing rooftop units (RTUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Race-Specific Risk Factors for Homeownership Disparity in the Continental United States

The United States has a racial homeownership gap due to a legacy of historic inequality and discriminatory policies, but factors that contribute to the racial disparity in homeownership rates between White Americans and people of color have not been fully characterized. In order to alleviate this issue, policymakers need a better understanding of how risk factors affect the homeownership rates of racial and ethnic groups differently. In this study, data from several publicly available surveys, including the American Community Survey and United States Census, were leveraged in combination with statistical learning models to investigate potential factors related to homeownership rates across racial and ethnic categories, with a focus on how risk factors vary by race or ethnicity. Our models indicated that job availability for specific demographics, and specific regions of the United States were factors that affect homeownership rates in Black, Hispanic, and Asian populations in different ways. Based on the results of this study, it is recommended policymakers promote strategies to increase access to jobs for people of color (POC), such as vocational training and programs to reduce implicit bias in hiring practices. These interventions could ultimately increase homeownership rates for POC and be a step toward reducing the racial wealth gap.

99 GENERAL AND MISCELLANEOUS↗