Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Validation of Combined Analytical Methods to Predict Slip in Cylindrical Roller Bearings

This paper presents a combination of models that together calculate the cage and roller speeds of a cylindrical roller bearing. The models consider elastohydrodynamic lubrication and contact elasticity between the roller and raceway, roller centrifugal forces, hydrodynamic lubrication at the cage pocket, and frictional forces. Using these models, the predicted cage and roller speeds and the extent of slip are compared to measurements acquired on cylindrical roller bearings in a commercial gearbox in steady-state and transient operating conditions of a wind turbine. In steady-state conditions at low wind speeds and low lubricant temperatures, cage and roller slip up to 60% occur in the loaded zone of the bearing. In the unloaded zone, up to 80% roller slip occurs. Cage and roller slip then decrease as the lubricant temperature and wind speed increases. In general, the analytical model results match experimental measurements within 10% for lubricant temperatures above 40 degrees C and wind speeds over 10 meters per second. The analytical model is further evaluated during a transient start-up event and highly dynamic emergency stop event and also used to examine changes in the bearing design or lubricant properties. Furthermore, roller and cage slip in cylindrical bearings is a combined effect of the bearing design, applied load, shaft speed, and lubricant properties and temperature, and can be quickly evaluated with the combined analytical models.

17 WIND ENERGY↗

Compositional screening of Ce-doped (Gd,Lu,Y) 3 (Al,Ga) 5 O 12 ceramics prepared by quenching from melt and their luminescence properties

Quenching from the melt using an Optical Floating Zone furnace was investigated as a possible high-throughput preparation method in order to screen novel scintillating materials. To validate this method, polycrystalline rare-earth aluminum garnets and yttrium gallium aluminum garnets were synthesized and characterized by X-ray diffraction, photoluminescence and radioluminescence emission spectra as well as radioluminescence imaging and compared to the previously reported properties of those materials. In order to achieve rapid, but quantitative comparison of the materials, pellets fabricated from the synthesized powders were sintered; two different sintering conditions were investigated and compared. Therefore, a simplistic energy deposition and light absorption model for brightness of opaque samples under X-ray irradiation was developed to estimate the relative scintillation efficiency of the materials. Based on the results, Y 3 Al 5 O 12 , LuY 2 Al 5 O 12 and GdY 2 Al 5 O 12 seem to have the highest scintillation efficiency among the prepared samples.

36 MATERIALS SCIENCE↗

Divide and conquer: using RhizoVision Explorer to aggregate data from multiple root scans using image concatenation and statistical methods

Roots are important in agricultural and natural systems for determining plant productivity and soil carbon inputs. Sometimes, the amount of roots in a sample is too much to fit into a single scanned image, so the sample is divided among several scans, and there is no standard method to aggregate the data. Here, we describe and validate two methods for standardizing measurements across multiple scans: image concatenation and statistical aggregation. We developed a Python script that identifies which images belong to the same sample and returns a single, larger concatenated image. These concatenated images and the original images were processed with RhizoVision Explorer, a free and open-source software. An R script was developed, which identifies rows of data belonging to the same sample and applies correct statistical methods to return a single data row for each sample. These two methods were compared using example images from switchgrass, poplar, and various tree and ericaceous shrub species from a northern peatland and the Arctic. Most root measurements were nearly identical between the two methods except median diameter, which cannot be accurately computed by statistical aggregation. We believe the availability of these methods will be useful to the root biology community.

59 BASIC BIOLOGICAL SCIENCES↗

Development and validation of a quantitative proton NMR method for the analysis of pregnenolone

Pregnenolone (PREG) is an endogenous steroid frequently sold as an over-the-counter dietary supplement touted to promote neurological and immunological health. While the PREG dietary supplement is added to the diet for health benefits, there are no FDA approved PREG drugs. However, compounded PREG drug products are available to U.S. patients. The FDA works with state regulatory authorities on the oversight of compounding activities, including developing 503A and 503B lists of bulk substances that compounders are permitted to use. PREG is one of the substances publicly nominated to be included on the 503B list. Compounded hormone therapies such as those using PREG are of interest given the lack of standardization in compounded drug products which may increase the possibility of underdosing, overdosing, or contamination. However, no USP monograph currently exists to evaluate the quality of PREG drug substance or product. To address knowledge gaps and assist in quality control, a simple and rapid quantitative proton nuclear magnetic resonance spectroscopy (qNMR) method for the identification and assay of PREG in different types of PREG products was developed and validated. PREG samples were characterized using 1D 1 H and 2D 1 H– 13 C HSQC NMR spectra. The qNMR assay method (taking approximately 10 min per NMR spectrum) was validated for precision, accuracy, specificity, robustness and linearity per ICH Q2(R1) guidance. The method was validated in a range from 0.032 to 3.2 mg/mL. As a proof of concept, seven PREG bulk substance samples, three tablet and two capsule PREG dietary supplements were assessed by the qNMR analytical procedure. NMR data from all tested samples met the expected criteria for identification and assay. The results demonstrate the potential of qNMR for the quality assessment of different types of PREG samples.

60 APPLIED LIFE SCIENCES↗

Asteroids seen by JWST-MIRI: Radiometric size, distance, and orbit constraints

Infrared measurements of asteroids are crucial for the determination of physical and thermal properties of individual objects, and for understanding the small-body populations in the solar system as a whole. However, standard radiometric methods can only be applied if the orbit of an object is known, hence its position at the time of the observation. With JWST-MIRI observations the situation will change and many unknown, often very small, solar system objects will be detected. Later orbit determinations are difficult due to the faintness of the objects and the lack of dedicated follow-up concepts. We present MIRI observations of the outer-belt asteroid (10920) 1998 BC1 and an unknown object, detected in all nine MIRI bands in close apparent proximity to (10920). We developed a new method called STM-ORBIT to interpret the multi-band measurements without knowing the object’s true location. The power of the new technique is that it determines the most-likely heliocentric and observer-centric distance and phase angle ranges, allowing us to make a radiometric size estimate. The application to the MIRI fluxes of (10920) was used to validate the method. It leads to a confirmation of the known radiometric size-albedo solution, and puts constraints on the asteroid’s location and orbit in agreement with its true orbit. To back up the validation of the method, we obtained additional ground-based light curve observations of (10920), combined with Gaia data, which indicate a very elongated object (a/b ≥ 1.5), with a spin-pole at (λ, β) ecl = (178°, +81°), with an estimated error of about 20°, and a rotation period of 4.861191 ± 0.000015 h. A thermophysical study of all available JWST-MIRI and WISE measurements leads to a size of 14.5–16.5 km (diameter of an equal-volume sphere), a geometric albedo pV between 0.05 and 0.10, and a thermal inertia in the range 9–35 (best value 15) J m -2 s -0.5 K -1 . For the newly discovered MIRI object, the STM-ORBIT method revealed a size of 100–230 m. The new asteroid must be on a low-inclination orbit (0.7° < i < 2.0°) and it was located in the inner main-belt region during JWST observations. A beaming parameter η larger than 1.0 would push the size even below 100 meters, a main-belt regime that has escaped IR detections so far. This kind of MIRI observations can therefore contribute to formation and evolution studies via classical size-frequency studies, which are currently limited to objects larger than about one kilometer in size. We estimate that MIRI frames with pointings close to the ecliptic and short integration times of only a few seconds will always include a few asteroids; most of them will be unknown objects.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INFLUENCE OF CHANGES IN NUCLEAR COVARIANCE DATA ON THE CALCULATION OF Ck FOR HIGHLY ENRICHED URANIUM SOLUTION SYSTEMS

Since their initial development nearly 20 years ago, sensitivity/uncertainty (S/U) techniques have been increasingly applied to criticality safety validation. These techniques can generally be applied quickly and for a range of purposes after the initial investment of calculating sensitivities for a safety analysis model and a range of potential benchmark experiments. This paper discusses these applications and how they have been affected by changes in covariance data libraries.Critical experiment selection is the most prominent area in which S/U methods impact validation efforts. These methods allow for rigorous calculation of similarity between safety analysis models and potential benchmarks. The most widely used of these methods is the integral parameter ck, although other integral parameters such as E and some non-integral parameters have also been explored. The ck parameter calculates the fraction of nuclear data–induced uncertainty shared between an application and an experiment; this metric is predicated on the assessment that nuclear data errors are the most likely source of computational bias. Therefore, values of ck are inherently dependent on the nuclear covariance library used to calculate them and inevitably change when these data change.Past studies have shown how much the ck values can vary, especially in difficult validation cases like burnup credit. These significant changes are the result of differences in the relative uncertainties of nuclides with large sensitivities, and they imply differences in benchmark applicability to the safety analysis model. This paper demonstrates that more common criticality safety models involving single fissile species have significantly less variability of ck between covariance libraries, thus enhancing confidence in the application of S/U methods for experiment selection in these scenarios. This paper presents case studies examining the impact of these changes on some hypothetical safety analysis systems.

Clarity, Justin↗

Quantifying metal-binding specificity of Cc NikZ-II from Clostridium carboxidivorans in the presence of competing metal ions

Many proteins bind transition metal ions as cofactors to carry out their biological functions. Despite binding affinities for divalent transition metal ions being predominantly dictated by the Irving-Williams series for wild-type proteins, in vivo metal ion binding specificity is ensured by intracellular mechanisms that regulate free metal ion concentrations. However, a growing area of biotechnology research considers the use of metal-binding proteins in vitro to purify specific metal ions from wastewater, where specificity is dictated by the protein's metal binding affinities. A goal of metalloprotein engineering is to modulate these affinities to improve a protein's specificity towards a particular metal; however, the quantitative relationship between the affinities and the equilibrium metal-bound protein fractions depends on the underlying binding mechanisms. Here we demonstrate a high-throughput intrinsic tryptophan fluorescence quenching method to validate binding models in multi-metal solutions for CcNikZ-II, a nickel-binding protein from Clostridium carboxidivorans. Using our validated models, we quantify the relationship between binding affinity and specificity in different classes of metal-binding models for CcNikZ-II. In conclusion, we further illustrate the potential relevance of data-informed models to predicting engineering targets for improved specificity.

59 BASIC BIOLOGICAL SCIENCES↗

Verification, Validation, and Calibration Through a Causal Lens

While typical validation and verification approaches focus on identifying the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on identifying causal relationships between data elements. Statistical and machine-learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between data sets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify, and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles, it is known as a directed acyclic graph. A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts can identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Simulation of kinematic Kikuchi diffraction patterns from atomistic structures

One of the limitations of atomistic simulations is that many of the computational tools used to extract structural information from atomic trajectories provide metrics that are not directly compatible with experiments for validation. In this work, to bridge between simulation and experiment, a method is presented to produce simulated Kikuchi diffraction patterns using data from atomistic simulations, without requiring a priori specification of the crystal structure or defect periodicity. The Kikuchi pattern simulation is based on the kinematic theory of diffraction, with Kikuchi line intensities computed via a discrete structure factor calculation. Reciprocal lattice points are mapped to Kikuchi lines using a geometric projection of the reciprocal space data. This method is validated using single crystal atomistic models, and the novelty of this approach is emphasized by simulating kinematic Kikuchi diffraction patterns from an atomistic model containing a nanoscale dislocation loop. Deviations in kinematic Kikuchi line intensities are explained considering the displacement field of the dislocation loop, as is done in diffraction contrast theory.

42 ENGINEERING↗

Single-Walled Carbon Nanotubes with Confined Chalcogens as the Catalysts and Electrodes for Oxygen Reduction Reaction in Fuel Cells

The goal of this project is to synthesize and characterize a new non-metal electro-catalyst for oxygen reduction reaction (ORR) for fuel cell applications. The intended catalyst is a composite material composed of sulfur chains encapsulated in narrow diameter single-walled carbon nanotubes (S@SWNTs). S@SWNTs were successfully synthesized through sulfur vapor infusion method, and validated with Raman spectroscopy. However, the electrochemical analysis on the ORR catalytic activity of S@SWNTs indicated that it had low ORR catalytic activity. Our theoretical study based on density functional theory (DFT) revealed that the poor oxygen adsorption (low binding energy) on the surface of S@SWNTs was the bottleneck of the entire catalytic reaction. The focus of the project was subsequently pivoted to the development of a new non-noble metal ORR catalyst that could provide durability in acidic electrolyte. The hypothesis was to encapsulate small iron (Fe) clusters in SWNTs (Fe@SWNTs) can provide ORR electro-catalytic activity and long durability in acidic environment. DFT-based computational studies were carried out to explore the feasibility of the Fe@SWNTs catalyst. The theoretical study indicated that Fe@SWNTs indeed could catalyze the ORR with lower theoretical overpotential than platinum (Pt). However, its weaker bonding energy with oxygen was the bottleneck of the overall reaction. On the other hand, Fe clusters (composed of 7 Fe atoms) encapsulated in nitrogen-doped SWNTs (Fe 7 @N 4 WSNTs) showed proper oxygen adsorption by the Fe cluster and low theoretical overpotential of ORR. Comparing to the Fe single atom catalyst on N-doped SWNTs (Fe-N 4 SWNTs), which is one the best non-noble metal ORR catalysts reported in the literature, the Fe 7 @N 4 WSNTs showed lower overpotential and better resistance to acidic environment. Fe encapsulated N-doped SWNTs were synthesized with ferrocene as the Fe precursors through vapor infusion method, and experimental validate is underway. This study theoretically demonstrated the feasibility of a new type of non-noble metal electro-catalyst for ORR that could have high catalytic activity and long durability.

08 HYDROGEN↗

Residual Stress Measurements in Extreme Environments for Hazardous, Layered Specimens

In nuclear fuel plates of low-enriched U-10Mo (LEU) clad with aluminum by hot isostatic pressing (HIP), post-irradiation stresses arising during reactor shutdown are a major concern for safe reactor operations. Measurement of those residual stresses has not previously been possible because the high radioactivity of the plates requires handling only by remote manipulation in a hot cell. The incremental slitting method for measuring through-thickness stress profiles was modified, and a system for automated, remote operation was built and tested. Experimental modifications consisted of replacing electric-discharge machining (EDM) with a small end mill and strain-gauge measurements with cantilever displacement measurements. The inverse method used to calculate stresses was the pulse-regularization method modified to allow discontinuities across material interfaces. The new system was validated by comparing with conventional slitting on a depleted U-10Mo (DU) fuel plate. The new system was applied to two measurements each on six as-fabricated (pre-irradiation) LEU miniature fuel plates. Variations between the measurements at two locations in the same plate were strongly correlated with measured geometrical heterogeneity in the plate—a tilt in the fuel foil. Compressive stresses in the U-10Mo were shown to increase from 20 to 250 MPa as the ratio of aluminum thickness to U-10Mo thickness increased causing increased constraint during cooling. Faster cooling rates during processing also increased stress magnitudes. The measurements trends agreed with data in the literature from similar plates made with DU, which further validates the method. Because other methods are impractical in a hot cell, the modified slitting method is now poised for the first measurements of post-irradiation stresses.

36 MATERIALS SCIENCE↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

A new calibration method for charm jet identification validated with proton-proton collision events at $\sqrt{s}$ =13 TeV

Many measurements at the LHC require efficient identification of heavy-flavour jets, i.e. jets originating from bottom (b) or charm (c) quarks. An overview of the algorithms used to identify c jets is described and a novel method to calibrate them is presented. This new method adjusts the entire distributions of the outputs obtained when the algorithms are applied to jets of different flavours. It is based on an iterative approach exploiting three distinct control regions that are enriched with either b jets, c jets, or light-flavour and gluon jets. Results are presented in the form of correction factors evaluated using proton-proton collision data with an integrated luminosity of 41.5 fb$^{-1}$ at √s = 13 TeV, collected by the CMS experiment in 2017. The closure of the method is tested by applying the measured correction factors on simulated data sets and checking the agreement between the adjusted simulation and collision data. Furthermore, a validation is performed by testing the method on pseudodata, which emulate various mismodelling conditions. The calibrated results enable the use of the full distributions of heavy-flavour identification algorithm outputs, e.g. as inputs to machine-learning models. Thus, they are expected to increase the sensitivity of future physics analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exxon Mobil-NETL Testing of DAC Materials

This joint initiative is aimed at extending our understanding of real DAC testing conditions at the NETL DAC testbed facility. Of particular focus will be: • Small Scale testing of powdered and formulated materials (supplied by ExxonMobil) to evaluate various performance metrics under DAC process cycles • Pilot scale testing of formulated materials at larger scales ExxonMobil will work with NETL to shake down equipment, validate testing methods, and define best practices for data analysis. Three tasks are proposed: 1. Validation of multi-cycle test data on powdered and formulated materials to benchmark various performance metrics of these materials. 2. Steam regeneration of powdered samples at small scale to define baseline performance under commercially relevant conditions. 3. Pilot scale testing of larger formulated materials to test commercially relevant samples under actual process cycles.

36 MATERIALS SCIENCE↗

A Versatile and Accurate Method for Halo Mass Determination from Phase-space Distribution of Satellite Galaxies

We propose a versatile and accurate method to estimate the halo mass and concentration from the kinematics of satellite galaxies. We construct the 6D phase-space distribution function of satellites from a cosmological simulation based on the similarity of internal dynamics for different halos. Within the Bayesian statistical framework, not only can we efficiently infer the halo mass and concentration, we can also treat various observational effects, including the selection function, incomplete data, and measurement errors, in a rigorous and straightforward manner. Through tests with mock samples, we show that our method is valid and accurate, as well as more precise than pure steady-state methods. It can constrain the halo mass to within ~20% using only 20 tracers and has a small intrinsic uncertainty of ~10%. In addition to the clear application to the Milky Way and similar galaxies, our method can be extended to galaxy groups or clusters.

79 ASTRONOMY AND ASTROPHYSICS↗