Search NASA⌕ Search

SEARCH · Search NASA

Results for “value analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Comparing CRT and Pandora Tagged Tracks in ICARUS

The ICARUS Liquid Argon Time Projection Chamber (LArTPC) is used to investigate short-baseline neutrino oscillations and the possible existence of sterile neutrinos. To aid in identifying and rejecting cosmic ray backgrounds, the system is outfitted with external Cosmic Ray Taggers (CRTs). The CRT is able to measure more tracks and at a wider range of angles, useful in further detailing future calibrations. This project compared the most probable values (MPVs) of charge deposition between CRT tagged and TPC tagged tracks. The Y-Z maps of charge scale for both datasets show a strong correlation, not just in their overall structure, but also in how they reflect known detector effects. Both reconstruction paths showed similar structures in their charge distribution, such as less effective wire section or mechanical support, confirming that CRT-tagged tracks, despite being external, respond to the same calibration landscape as Pandora tracks, validating previous Pandora reconstructions and values. Overall, the analysis supports the idea that the CRT tags are a useful addition to ICARUS calibration efforts. Their broad angular range and independence from Pandora reconstruction make them a helpful secondary tool and a potential asset in extending calibration across the detector volume.

Thayer, Abbie [Fermilab; Colorado State U.]↗

Analysis of Waste Material Feedstocks Using Laser-Induced Breakdown Spectroscopy and Machine Learning

Predicting properties such as heating value, ash fusion temperature, and mineral ash composition from Laser-Induced Breakdown Spectroscopy (LIBS) data can make gasifiers more flexible to different feedstocks. Understanding these feedstock properties in-situ improves feedstock conversion modelling methods that allow for consistent operation, higher carbon conversion, and reduced fouling and erosion rates. The purpose of this study is to demonstrate methods for model creation that take LIBS data as predictor features and estimate higher order material properties as a function of feedstock material properties. Six samples were chosen to represent a mixture of abundant and carbon rich waste materials. LIBS measurements were performed on these samples for elemental wavelengths and intensity values. Laboratory analytical results were obtained for each sample’s heating value, proximate and ultimate analysis, mineral ash composition, ash fusion temperatures, and viscosity temperatures. Thermal conductivity was measured using a HotDisk TPS 2500S. LIBS measurements were processed and used as predictor features for machine learning (ML) models to predict the sample’s material properties. Predictor feature selection algorithms, particularly minimum redundancy maximum relevance (mRMR), reduced the dimensionality of ML models. Many modelling methods such as Gaussian process regression (GPR), regression tree, neural networks (NN), and support vector machines (SVM) were demonstrated to be effective at predicting higher order properties; however, mRMR with GPR stood out as a clear winning combination.

01 COAL, LIGNITE, AND PEAT↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗

Model of Operation-and-Maintenance Costs for Photovoltaic Systems

This article presents a method for calculating costs associated with operation and maintenance (O&M) of photovoltaic (PV) systems. It compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($\$$/year) for each year of an analysis period, the net present value ($\$$) of life cycle costs accumulated over the analysis period, and the reserve account amount ($\$$). Here we show that this method is an improvement over the previous averaged or levelized per-unit ($\$$/kW/year) valuations for estimating PV O&M costs, because it allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string or central inverter) and site and environmental conditions (e.g., snow, pollen, bird populations). This model also distinguishes costs that vary from year to year and increase at different rates over time because of heuristic failure distributions (e.g. Weibull or Lognormal distribution) based on actuarial data for many of the services. This cost model was created by the PV O&M Working Group of researchers and industry, sponsored by DOE Solar Energy Technologies Office, and has been published in an on-line version hosted by SunSpec Alliance at apsuite.sunspec.org. A spreadsheet version is included with this paper as supplementary material.

14 SOLAR ENERGY↗

Computer-aided design of stability enhanced nicotinamide cofactor biomimetics for cell-free biocatalysis

Cell-free biocatalysis (CFB) is an efficient and environmentally friendly method to synthesize molecules such as pharmaceuticals, biochemicals, and biofuels through the in vitro use of enzyme cascades. These enzymes often require redox cofactors to drive chemical reactions. Natural redox cofactors (NAD(P)H) are expensive to isolate, motivating synthetic nicotinamide cofactor biomimetics (NCBs) as a cost-effective solution. A select handful of NCBs have been identified as potential NAD(P)H alternatives with comparable or improved redox capabilities, however, they display a tendency to degrade in common buffers. In this study, a library of 132 NCB candidates is systematically generated, over 85% of which have not been characterized in the literature, to expand the diversity of currently explored NCBs. The decomposition mechanism of NCBs in phosphate is evaluated using density functional theory (DFT), revealing protonation at the nicotinamide C5 position as a reporter of cofactor stability. Based on this result, we trained a linear regression model on DFT calculated descriptors to predict NCB stability in phosphate buffer, achieving mean absolute error (MAE) and root mean squared error (RMSE) values within computational accuracy. Analysis of key atomic descriptors and qualitative trends in our dataset informed the design of novel NCB candidates we propose with optimized stability. This work enables researchers to predict the relative stability of NCBs before synthesis, thereby streamlining the process to make CFB more affordable and viable at industry scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shell model analysis of the B ( E 2,2 + → 0 + ) values in the A = 70, T = 1 triplet 70 Kr, 70 Br, and 70 Se

The B(E2, 2 + → 0 + ) transition strengths of the T=1 isobaric triplet 70 Kr, 70 Br, 70 Se, recently measured at the RIKEN Radioactive Isotope Beam Factory (RIBF), are discussed in terms of state-of-the-art large scale shell model calculations using the JUN45 and JUN45 + LNPS plus Coulomb interactions. In this Letter we argue that, depending on the effective charges used, the calculations are either in line with the experimental data within statistical uncertainties, or the anomaly happens in 70 Br, rather than 70 Kr. In the latter case, we suggest that it can be due to the presence of a hitherto undetected 1 + T = 0 state below the yrast 2 + T = 1 state. Furthermore, our results do not support a shape change of 70 Kr with respect to the other members of the isobaric multiplet.

59 ≤ A ≤ 89↗

Grid Value Propositions for Tidal Generation Resources - a Temporal Analysis

As the energy sector experiences a paradigm shift towards cleaner and greener generation sources, the need for evaluating the applicability of marine energy for grid-based applications has intensified. This is because marine energy (ocean, wave and tidal) may be utilized to provide unique benefits to electric grid operations, especially in conjunction with other established renewable technologies (such as wind and solar) or technologies like energy storage. In this work, we focus our attention on some specific characteristics of two types of marine energy resources i.e. tidal and ocean current based resources. Specifically, we perform a comprehensive temporal analysis using a suite of metrics on resource data to characterize the inherent predictability of the resource across various time scales of interest. We also investigate the correlation of tidal power generation profiles with energy demand and comment on the effectiveness of having such resources in the overall generation portfolio.

Bhattacharya, Saptarshi↗

Comparative Techno-economic Analysis and Life Cycle Assessment of Producing High-Value Chemicals and Fuels from Waste Plastic via Conventional Pyrolysis and Thermal Oxo-degradation

The rapid rise in global plastic production in recent decades has resulted in the massive generation of plastic waste. Over 75% of the plastic waste generated in the United States was sent to landfills, with a meager 8.7% recycled. Plastics are valuable feedstocks for platform chemicals and fuels. Chemical upcycling of waste high-density polyethylene (HDPE) is gaining more attention as a potentially feasible and environmentally friendly plastic waste management technology. Conventional pyrolysis (CPY) and thermal oxo-degradation (TOD) are two chemical upcycling technologies actively researched for decomposing waste HDPE into valuable chemicals and fuels. However, there are few studies on the techno-economic analysis (TEA) and life cycle assessment (LCA) of these technologies for converting waste HDPE to valuable products. This study conducts a comparative TEA and LCA study of the thermochemical decomposition of waste HDPE to produce gaseous (ethylene and propylene) and liquid (naphtha, diesel, and wax) products by CPY and TOD. The study elucidates and compares the impact of hydrocracking longer chain hydrocarbons to produce more valuable products on the TEA and LCA. The TEA showed that the fixed capital investment could range from $\$32.5$ million for TOD without hydrocracking to $\$244$ million for CPY with hydrocracking scenarios. Annual revenues range from $\$28.1$ million to $\$71.5$ million in favor of scenarios with hydrocracking. However, the net present value ranges from $\$1.4$ million to $\$265.8$ million in favor of scenarios without hydrocracking. Sensitivity analysis showed that fixed capital cost, facility capacity, and product prices have the biggest impact on the process economics of the facilities, while utilities and waste transportation to refineries have the biggest impact on environmental impacts. Here, the LCA showed that primary products from scenarios without hydrocracking can be more environmentally friendly than virgin products from petroleum processes. However, TOD and CPY with hydrocracking primary products have more emissions than those of virgin products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Demonstration of 151 Sm analysis using Trinity nuclear debris samples

Here, the long-lived fission product 151 Sm (T 1/2 ≈ 90 y) present in archived dissolved Trinity nuclear test debris samples was analyzed using liquid scintillation counting and the results were compared to the expected values based upon historical analysis results. The measured 151 Sm activities were found to agree with the expected values within experimental error. This demonstration validates the use of this technique in situations where the sample is too old for traditional shorter half-life radioactive fission product signatures such as 99 Mo (T 1/2 = 2.75 d), 97 Zr (T 1/2 = 16.7 h), 147 Nd (T 1/2 = 10.98 d), and 153 Sm (T 1/2 = 46.3 h), or too dilute for determining fissions through stable isotope ratio measurements.

151Sm↗

Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product Report

Objective analysis (OA) is a method of mapping unstructured data to a structured grid. In the context of scanning radar data, OA is used to interpolate data in antenna coordinates (range, azimuth, and elevation) onto a regularly spaced Cartesian grid (Trapp and Doswell 2000). The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Mapped Moments to a Cartesian Grid (MMCG) Value-Added Product (VAP) uses the Python ARM Radar Toolkit (Py-ART), a data model-driven interactive architecture for working with weather radar data, to map the data to a Cartesian grid (Helmus and Collis 2016). MMCG, with Py-ART built in, has the ability to take radar data in antenna coordinates and map the gates to a Cartesian grid using inverse distance weight functions such as Cressman (square) and Barnes (exponential), but also can filter the data during the interpolation. MMCG also allows arbitrary formulations for the radius of influence, which are matched to particular radar scanning strategies. This creates a complex parameter space for optimizing the retention of storm structure detail while minimizing artifacts. MMCG takes data processed with ARM’s Corrected Precipitation Radar Moments in Antenna Coordinates (CMAC) VAP and maps it to a Cartesian grid as the output product. A variety of fields that have been mapped to the Cartesian grid are then saved to plots to complement each grid file.

54 ENVIRONMENTAL SCIENCES↗

Image-Guided Intraoperative Assessment of Surgical Margins in Oral Cavity Squamous Cell Cancer: A Diagnostic Test Accuracy Review

The assessment of resection margins during surgery of oral cavity squamous cell cancer (OCSCC) dramatically impacts the prognosis of the patient as well as the need for adjuvant treatment in the future. Currently there is an unmet need to improve OCSCC surgical margins which appear to be involved in around 45% cases. Intraoperative imaging techniques, magnetic resonance imaging (MRI) and intraoral ultrasound (ioUS), have emerged as promising tools in guiding surgical resection, although the number of studies available on this subject is still low. The aim of this diagnostic test accuracy (DTA) review is to investigate the accuracy of intraoperative imaging in the assessment of OCSCC margins. By using the Cochrane-supported platform Review Manager version 5.4, a systematic search was performed on the online databases MEDLINE-EMBASE-CENTRAL using the keywords “oral cavity cancer, squamous cell carcinoma, tongue cancer, surgical margins, magnetic resonance imaging, intraoperative, intra-oral ultrasound”. Ten papers were identified for full-text analysis. The negative predictive value (cutoff < 5 mm) for ioUS ranged from 0.55 to 0.91, that of MRI ranged from 0.5 to 0.91; accuracy analysis performed on four selected studies showed a sensitivity ranging from 0.07 to 0.75 and specificity ranging from 0.81 to 1. Image guidance allowed for a mean improvement in free margin resection of 35%. IoUS shows comparable accuracy to that of ex vivo MRI for the assessment of close and involved surgical margins, and should be preferred as the more affordable and reproducible technique. Both techniques showed higher diagnostic yield if applied to early OCSCC (T1–T2 stages), and when histology is favorable.

60 APPLIED LIFE SCIENCES↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Baseline Characterization Database Verification Report ? NBG-17 Billet V104

The purpose of this report is to present data collected in the Baseline Graphite Characterization Program, which is directly tasked with supporting the Idaho National Laboratory’s (INL’s) research and development efforts on the Advanced Reactor Technologies (ART) Program. This program populates a comprehensive database that reflects the baseline properties of nuclear-grade graphite regarding individual grade, billet, and position within individual billets. The physical- and mechanical-property information being collected will be transferred to the Nuclear Data Management and Analysis System (NDMAS), and that database will help populate the handbook of property data available to member nations of the Generation-IV International Forum. Transfer of these data from the applicable technical lead to the dissemination databases available to other end users requires a full review of the test procedures and data-collection efforts through an analysis of the multiple summary spreadsheets and values being collected. This report represents the analysis for NBG-17 Billet V104 and facilitates release of associated data to the NDMAS custodians. Millions of raw data points have been collected during testing and quantification analyses for these billets. The summary scalar property values and supplementary traceability data are collected into comprehensive spreadsheets. Data sets are composed of single billets of graphite for any given grade, organized by mechanical test-specimen type, and further subdivided into individual spreadsheet tabs according to the specific test or evaluation being performed. A direct analysis of properties was not conducted, and this report does not provide information on the validity or performance characteristics of the graphite itself. Rather, this report is intended as a verification of the completeness of actual data collected in accordance with PLN-3467, “Baseline Graphite Characterization Plan: Electromechanical Testing,” [1] and PLN-3348 “Graphite Mechanical Testing” [2] and their representation of the measurement and test results with sole regard to the graphite billets under evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ice-nucleating particles in precipitation samples from the Texas Panhandle

Ice-nucleating particles (INPs) influence the formation of ice crystals in clouds and many types of precipitation. This study reports unique properties of INPs collected from 42 precipitation samples in the Texas Panhandle region from June 2018 to July 2019. We used a cold stage instrument called the West Texas Cryogenic Refrigerator Applied to Freezing Test system to estimate INP concentrations per unit volume of air (nINP) through immersion freezing in our precipitation samples with our detection capability of >0.006 INP L -1 . A disdrometer was used for two purposes: (1) to characterize the ground-level precipitation type and (2) to measure the precipitation intensity as well as size of precipitating particles at the ground level during each precipitation event. While no clear seasonal variations of n INP values were apparent, the analysis of yearlong ground-level precipitation observation as well as INPs in the precipitation samples showed some INP variations, e.g., the highest and lowest n INP values at -25°C both in the summer for hail-involved severe thunderstorm samples (3.0 to 1130 INP L -1 ), followed by the second lowest at the same temperature from one of our snow samples collected during the winter (3.2 INP L -1 ). Furthermore, we conducted bacteria community analyses using a subset of our precipitation samples to examine the presence of known biological INPs. In parallel, we also performed metagenomics characterization of the bacterial microbiome in suspended ambient dust samples collected at commercial open-lot livestock facilities (cattle feedyards hereafter) in the Texas Panhandle (i.e., the northernmost counties of Texas, also known as “West Texas”) to ascertain whether local cattle feedyards can act as a source of bioaerosol particles and/or INPs found in the precipitation samples. Some key bacterial phyla present in cattle feedyard samples appeared in precipitation samples. However, no known ice nucleation active species were detected in our samples. Overall, our results showed that cumulative n INP in our precipitation samples below -20°C could be high in the samples collected while observing > 10 mm h -1 precipitation with notably large hydrometeor sizes and an implication of cattle feedyard bacteria inclusion.

54 ENVIRONMENTAL SCIENCES↗

ECAR-1930 BASELINE CHARACTERIZATION DATABASE VERIFICATION REPORT - NBG-18 BILLET 635-14

The purpose of this Engineering Calculations and Analysis Report is to present the data being collected in the Baseline Graphite Characterization program, which is directly tasked with supporting the Idaho National Laboratory’s (INL’s) research and development efforts on the Next Generation Nuclear Plant (NGNP)/Very High Temperature Reactor (VHTR). This program is populating a comprehensive database that will reflect the baseline properties of nuclear-grade graphite with regard to individual grade, billet, and position within individual billets. The physical and mechanical property information being collected will be transferred to the NGNP Data Management and Analysis System (NDMAS), and from that database will help populate handbook of property data available to member nations of the Generation IV International Forum (GIF). The transfer of this data from the applicable technical lead to the dissemination databases available to other end users requires a full review of the test procedures and data collection efforts through an analysis of the multiple summary spreadsheets and values being collected. This report represents that analysis for a single billet of nuclear grade graphite (NBG-18 billet 635-14) and facilitates the release of the associated data to the NDMAS custodians.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗