Search NASA⌕ Search

SEARCH · Search NASA

Results for “vanes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Pressure-loss and flow coefficients inside a chordwise-finned, impingement, convection, and film air-cooled turbine vane

Total-pressure-loss coefficients, flow discharge coefficients, and friction factors were determined experimentally for the various area and geometry changes and flow passages within an air-cooled turbine vane. The results are compared with those of others obtained on similar configurations, both actual and large models, of vane passages. The supply and exit air pressures were controlled and varied. The investigation was conducted with essentially ambient-temperature air and without external flow of air over the vane.

Hippensteele, S. A.↗

Experimental transient vane temperatures in a cascade for gas stream temperature cycling between 922 and 1644 K (1200 and 2500 F)

Experimental transient turbine vane metal temperatures were obtained from tests conducted on air-cooled vanes installed in a four-vane cascade for a gas temperature cycled between 922 and 1644 K (1200 and 2500 F). Transient data were recorded by a high-speed data acquisition system. Temperatures at the same phase of each transient cycle were repeatable between cycles to within 11 kelvins (20 F), simulated cruise and idle steady-state readings were repeated by the cruise and idle readings taken from the ends of a transient half-cycle at low pressure to within 17 kelvins (30 F). The tests were conducted at pressure levels of 31 and 83 N-sq cm (45 and 120 psia) with coolant temperatures of 811 and 589 K (1000 and 600 F), respectively.

Gauntner, D. J.↗

Water table tests of proposed heat transfer tunnels for small turbine vanes

Water-table flow tests were conducted for proposed heat-transfer tunnels which were designed to provide uniform flow into their respective test sections of a single core engine turbine vane and a full annular ring of helicopter turbine vanes. Water-table tests were also performed for the single-vane test section of the core engine tunnel. The flow in the heat-transfer tunnels was shown to be acceptable.

Meitner, P. L.↗

Metal temperatures and coolant flow in a wire cloth transpiration cooled turbine vane

An experimental heat transfer investigation was conducted on an air-cooled turbine vane made from wire-wound cloth material and supported by a central strut. Vane temperature data obtained are compared with temperature data from two full-coverage film-cooled vanes made of different laminated construction. Measured porous-airfoil temperatures are compared with predicted temperatures.

Gladden, H. J.↗

Reduction of Noise from a Fan Stage for a Turbofan Engine by Use of Long-Chord Acoustically-Treated Stator Vanes

A set of acoustically-treated long-chord vanes was designed to replace the vanes in an existing fan stage to investigate the noise reduction possibilities of both increased stator chord length and a method of incorporating acoustic damping material. The vanes were tested with both active and inactive acoustic surfaces. Results of the inactive tests show significant broadband noise effects with noise reductions in the middle to high frequencies and an increase at low frequencies. No reduction in blade passage tone was observed, but decreases in the overtones were observed. Results of the tests with the active acoustic treatment show large noise reductions over a wide frequency range.

Dittmar, J. H.↗

Reduction of noise from a fan stage for a turbofan engine by use of long-chord acoustically-treated stator vanes

A set of acoustically-treated long-chord vanes was designed to replace the vanes in an existing fan stage to investigate the noise reduction possibilities of both increased stator chord length and this method of incorporating acoustic damping material. The vanes were tested with both active and inactive acoustic surfaces. The inactive tests showed significant broadband noise effects with noise reductions in the middle to high frequencies and an increase at low frequencies. No reduction in blade passage tone was observed, but decreases in the overtones were observed. The tests with the active acoustic treatment showed large noise reductions over a wide frequency range.

Dittmar, J. H.↗

Film cooling on the pressure surface of a turbine vane

Film-cooling-air ejection from the pressure surface of a turbine vane was investigated, and experimental data are presented. This investigation was conducted in a four-vane cascade on a J75-size turbine vane that had a double row of staggered holes in line with the primary flow and located downstream of the leading edge region. The results showed that: (1) the average effectiveness of film-convection cooling was higher than that of either film cooling or convection cooling separately; (2) the addition of small quantities of film-cooling air always increased the cooling effectiveness relative to the zero-injection case; however, (3) the injected film must exceed a certain threshold value to obtain a beneficial effect of film cooling relative to convection cooling alone.

Gauntner, J. W.↗

Aerodynamic performance of axial-flow fan stage operated at nine inlet guide vane angles

The overall performance of a fan stage with nine inlet guide vane angle settings is presented. These data were obtained over the stable flow range at speeds from 60 to 120 percent of design for vane setting angles from -25 to 42.5 degrees. At design speed and design inlet guide vane angle, the stage has a peak efficiency of 0.892 at a pressure ratio of 1.322 and a flow of 25.31 kg/s. The stall margin based on peak efficiency and stall was 20 percent. Based on an operating line passing through the peak efficiency point at the design setting angle, the useful operating range of the stage at design speed is limited by stall at the positive setting angles and by choke at the negative angles. At design the calculated static thrust along the operating line varied from 68 to 114 percent of that obtained at design setting angle.

Moore, R. D.↗

Design, durability and low cost processing technology for composite fan exit guide vanes

A lightweight composite fan exit guide vane for high bypass ratio gas turbine engine application was investigated. Eight candidate material/design combinations were evaluated by NASTRAN finite element analyses. A total of four combinations were selected for further analytical evaluation, part fabrication by two ventors, and fatigue test in dry and wet condition. A core and shell vane design was chosen in which the unidirectional graphite core fiber was the same for all candidates. The shell material, fiber orientation, and ply configuration were varied. Material tests were performed on raw material and composite specimens to establish specification requirements. Pre-test and post-test microstructural examination and nondestructive analyses were conducted to determine the effect of material variations on fatigue durability and failure mode. Relevant data were acquired with respect to design analysis, materials properties, inspection standards, improved durability, weight benefits, and part price of the composite fan exit guide vane.

Blecherman, S. S.↗

Force and moment data from a wind-tunnel test of a tilt-nacelle V/STOL propulsion system with an attitude control vane

A large scale, tilt nacelle V/STOL propulsion system, with an attitude control vane assembly mounted in the exhaust, was tested. The effectiveness of the control vane as well as the aerodynamic characteristics of the entire propulsion system were determined. The results, in the form of tabulated coefficients, for both the vane forces and moments and the total forces and moments produced by the propulsion system are presented.

Betzina, M. D.↗

Effects of a ceramic coating on metal temperatures of an air-cooled turbine vane

The metal temperatures of air cooled turbine vanes both uncoated and coated with the NASA thermal barrier system were studied experimentally. Current and advanced gas turbine engine conditions were simulated at reduced temperatures and pressures. Airfoil metal temperatures were significantly reduced, both locally and on the average, by use of the the coating. However, at low gas Reynolds number, the ceramic coating tripped a laminar boundary layer on the suction surface, and the resulting higher heat flux increased the metal temperatures. Simulated coating loss was also investigated and shown to increase local metal temperatures. However, the metal temperatures in the leading edge region remained below those of the uncoated vane tested at similar conditions. Metal temperatures in the trailing edge region exceeded those of the uncoated vane.

Gladden, H. J.↗

Similarity tests of turbine vanes, effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. It is shown that the thermal performance can be evaluated reliably at reduced gas and coolant conditions; however, thermal conductivity corrections are required for the data at reduced conditions. Corrections for a ceramic thermal barrier coated vane are significantly different than for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 percent.

Gladden, H. J.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model is developed for variable-area (pivoted vane) radial turbines. The variation in stator loss with stator area is determined by a viscous loss model while the variation in rotor loss due to stator area variation (for no stator end-clearance gap) is determined through analytical matching of experimental data. An incidence loss model is also based on matching of the experimental data. A stator vane end-clearance leakage model is developed and sample calculations are made to show the predicted effects of stator vane end-clearance leakage on performance.

Meitner, P. L.↗

Similarity tests of turbine vanes - Effects of ceramic thermal barrier coatings

The role of material thermal conductivity was analyzed for its effect on the thermal performance of air-cooled gas turbine components coated with a ceramic thermal barrier material when tested at reduced temperatures and pressures. This study shows that the thermal performance can be evaluated reliably at reduced gas and coolant conditions. However, thermal conductivity corrections are required for the data at reduced conditions. These corrections for a ceramic thermal barrier coated vane are significantly different than the corrections for an uncoated vane. Comparison of uncorrected test data, therefore, would show erroneously that the thermal barrier coating was ineffective. When thermal conductivity corrections are applied to the test data these data are then shown to be representative of engine data and also show that the thermal barrier coating increases the vane cooling effectiveness by 12.5 precent.

Gladden, H. J.↗

Effects of blade-vane ratio and rotor-stator spacing on fan noise with forward velocity

A research fan stage is acoustically tested in an anechoic wind tunnel with a 41 m/sec tunnel flow. Two stator vane numbers giving cut-on and cut-off conditions are tested at three rotor stator spacings ranging from 0.5 to 2.0 rotor chords. Hot-film anemometer turbulence measurements are made at the leading edge of the stator for each spacing, and a crossed film anemometer is radially transversed to define streamwise and upwash characteristics of the rotor blade wakes. Trends in the acoustic results are observed in the front and aft quadrants at 80% design fan speed. Aft quadrant results demonstrate a fundamental tone 9 dB lower for the 25 vane stator than for the 11 vane stator, while overtone levels are 3 dB higher. The cut-off criterion strongly controls fundamental tone level at all spacings, and spacing trends of the wake-defect upwash component show good agreement with corresponding cut-on acoustic tone levels.

Woodward, R. P.↗

Icing Characteristics and Anti-Icing Heat Requirements for Hollow and Ternally Modified Gas-Heated Inlet Guide Vanes

A two-dimensional inlet-guide-vane cascade was investigated to determine the effects of ice formations on the pressure losses across the guide vanes and to evaluate the heated gas flow and temperature required to prevent Icing at various conditions. A gas flow of approximately 0.4 percent of the inlet-air flow was necessary for anti-icing a hollow guide-vane stage at an inlet-gas temperature of 500 F under the following icing conditions: air velocity, 280 miles per hour; water content, 0.9 gram per cubic meter; and Inlet-air static temperature, 00 F. Also presented are the anti-icing gas flows required with modifications of the hollow Internal gas passage, which show heatinput savings greater than 50 percent.

Gray, Vernon H.↗

Gas turbine ceramic-coated-vane concept with convection-cooled porous metal core

Analysis and flow experiments on a ceramic-coated-porous-metal vane concept indicated the feasibility, from a heat transfer standpoint, of operating in a high-temperature (2500 F) gas turbine cascade facility. The heat transfer and pressure drop calculations provided a basis for selecting the ceramic layer thickness (to 0.08 in.), which was found to be the dominant factor in the overall heat transfer coefficient. Also an approximate analysis of the heat transfer in the vane trailing edge revealed that with trailing-edge ejection the ceramic thickness could be reduced to (0.01 in.) in this portion of the vane.

Kascak, A. F.↗

Programmable controller system for wind tunnel diversion vanes

A programmable controller (PC) system automatic sequence control, which acts as a supervisory controller for the servos, selects the proper drives, and automatically sequences the vanes, was developed for use in a subsonic wind tunnel. Tunnel modifications include a new second test section (80 ft x 100 ft with a maximum air speed capability of 110 knots) and an increase in maximum velocity flow from 200 knots to 300 knots. A completely automatic sequence control is necessary in order to allow intricate motion of the 14 triangularly arranged vanes which can be as large as 70 ft high x 35 ft wide and which require precise acceleration and deceleration control. Rate servos on each drive aid in this control, and servo cost was minimized by using four silicon controlled rectifier controllers to control the 20 dc drives. The PC has a programming capacity which facilitated the implementation of extensive logic design. A series of diagrams sequencing the vanes and a block diagram of the system are included.

King, R. F.↗