Search NASASearch

SEARCH · Search NASA

Results for “variable density flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mode Propagation in Nonuniform Circular Ducts with Potential Flow

A previously reported closed form solution is expanded to determine effects of isentropic mean flow on mode propagation in a slowly converging-diverging duct, a circular cosh duct. On the assumption of uniform steady fluid density, the mean flow increases the power transmission coefficient. The increase is directly related to the increase of the cutoff ratio at the duct throat. With the negligible transverse gradients of the steady fluid variables, the conversion from one mode to another is negligible, and the power transmission coefficient remains unchanged with the mean flow direction reversed. With a proper choice of frequency parameter, many different modes can be made subject to a single value of the power transmission loss. A systematic method to include the effects of the gradients of the steady fluid variables is also described.

Cho, Y. C.

Mode propagation in nonuniform circular ducts with potential flow

A previously reported closed form solution is expanded to determine effects of isentropic mean flow on mode propagation in a slowly converging-diverging duct - a circular cosh duct. On the assumption of uniform steady fluid density, the mean flow increases the power transmission coefficient. The increase is directly related to the increase of the cutoff ratio at the duct throat. With the negligible transverse gradients of the steady fluid variables, the conversion from one mode to another is negligible, and the power transmission coefficient remains unchanged with the mean flow direction reversed. With a proper choice of frequency parameter, many different modes can be made subject to a single value of the power transmission loss. The paper also describes a systematic method to include the effects of the gradients of the steady fluid variables.

Cho, Y. C.

Design and operational features of low-disturbance wind tunnels at NASA Langley for Mach numbers from 3.5 to 18

The experimental and theoretical program at NASA Langley to develop high-speed low-disturbance wind tunnels for transition research is reviewed. Design and operational details of three new low-disturbance wind tunnels - the Mach-18 quiet helium, Mach-8 variable density, and Mach-3.5/Mach-6 high-speed low-disturbance tunnels, are presented. Focus is placed on the high-speed low-disturbance wind tunnel, which will have relatively large mass flows and run times from about 6 to 25 minutes. This facility is designed to provide direct simulation of low-disturbance flight conditions in the atmosphere. The Mach-8 facility will provide uniform flow conditions suitable for validation of aerodynamic codes, while the helium facility will be used for validation of boundary-layer and free shear-layer stability and transition prediction codes.

Beckwith, I. E.

Packed Bed Reactor Experiment (PBRE)-2: Pressure Drop Measurements in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this paper, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and compare with semi-empirical model pressure drop predictions. This work is supported by the National Aeronautics and Space Administration (NASA) under grant no. 80NSSC20K0830

Suratman Number

Pressure Gradient and Gas Hold-Up in Two-Phase Flows through Porous Media in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this presentation, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and gas hold-up and compare with semi-empirical model pressure drop predictions.

Brian Motil

Polynomial approximations of thermodynamic properties of arbitrary gas mixtures over wide pressure and density ranges

Computer programs for flow fields around planetary entry vehicles require real-gas equilibrium thermodynamic properties in a simple form which can be evaluated quickly. To fill this need, polynomial approximations were found for thermodynamic properties of air and model planetary atmospheres. A coefficient-averaging technique was used for curve fitting in lieu of the usual least-squares method. The polynomials consist of terms up to the ninth degree in each of two variables (essentially pressure and density) including all cross terms. Four of these polynomials can be joined to cover, for example, a range of about 1000 to 11000 K and 0.00001 to 1 atmosphere (1 atm = 1.0133 x 100,000 N/m sq) for a given thermodynamic property. Relative errors of less than 1 percent are found over most of the applicable range.

Allison, D. O.

Directional velocity analyzer for measuring electron distribution functions in plasmas

A directional velocity analyzer has been developed for measuring electron distribution functions in plasmas. It contains a collimating aperture which selects particles from a narrow cone in velocity space and a retarding potential analyzer. The distribution function f(v, theta, phi) is obtained from a large number of analyzer traces taken at different angles theta, phi. In addition, the small analyzer can be moved in space and the measurements are time resolved so as to obtain the complete phase space information f(v,r,t). The large data flow of this seven-variable function is processed with a high-speed digital data-acquisition system. The new electron velocity analyzer is applicable over a wide parameter range in electron energies and densities. Various cases of anisotropic distributions such as beams, shells, tails, and drifts have been successfully investigated.

Stenzel, R. L.

A decade's overview of Io's volcanic activity

Over the past decade some aspects of Io's volcanic activity have changed greatly, while others have essentially remained constant. This contrast has emerged from our study of multi-wavelength, infrared, observations of Io's thermal emission. From 1983 to 1992 we observed the disk integrated flux density of Io from the NASA Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii. Our spectral coverage allows us to separate out the emission components due to volcanic thermal anomalies which are warmer than the background emission caused by solar heating. Our temporal coverage allows us to resolve individual eruptions and also to obtain the disk-integrated flux density as a function of longitude (or, equivalently, orbital phase angle). Characteristics that persisted over the decade involve Loki's location and intensity of emission, the leading hemisphere emission, and the average heat flow. The variable aspects of Io over the decade include Loki's hotter area(s) and the outbursts in the leading hemisphere.

Matson, D. L.

Measurement of airfoil heat transfer coefficients on a turbine stage

A combined experimental and analytical program was conducted to examine the impact of a number of variables on the midspan heat transfer coefficients of the three airfoil rows in a one and one-half stage large scale turbine model. Variables included stator/rotor axial spacing, Reynolds number, turbine inlet turbulence, flow coefficient, relevant stator 1/stator 2 circumferential position, and rotation. Heat transfer data were acquired on the suction and pressure surfaces of the three airfoils. High density data were also acquired in the leading edge stagnation regions. Extensive documentation of the steady and unsteady aerodynamics was acquired. Finally, heat transfer data were compared with both a steady and an unsteady boundary layer analysis.

Dring, Robert P.

Energization and transport of ions of ionospheric origin in the terrestrial magnetosphere

The work of this grant has been predominantly focused on ion outflows from two data sets: Prognoz 7 and Dynamics Explorer. The Prognoz analysis studied ion densities, temperatures, and flow velocities in the magnetotail. The work performed under this contract consisted of developing a program to load the raw data, computing the background subtraction of a strong sun pulse, and using the net count to calculate the low order moments of the distribution function. The study confirms the results of ISEE with regard to the supply of plasma from the cusp as a major source of plasmasheet plasma and goes beyond this to discuss the use of ion velocities as a way to examine the motions of the magnetotail. The abstract of the work to be reported is included as an appendix. The work on the DE/Retarding Ion Mass Spectrometer is separated into two categories: (1) classification of low-energy ion flows from high-latitudes, and (2) studies of the polar wind. Major publications resulting from this work are also included as an appendix to this report. The polar wind is in a category by itself as a result of the thermal escape of hydrogen and helium because of ambipolar diffusion through the heavier, oxygen-dominated topside ionosphere. The analysis of the polar wind reports the flux variability as a function of season, magnetic activity, etc. Much effort has been expended under this grant to complete a follow on study of the thermal structure of the polar wind. Extensive display tools and analysis software have been developed and used in an attempt to carry out this thermal analysis. The present work uses a constrained fit scheme that combines the ion densities and flow velocities derived from Chandler et al. and a spacecraft potential derived from an empirical relation to the total ion density to determine the remaining fit parameter, the ion temperature, via a least squares fit to the RIMS data.

Waite, J. Hunter JR.

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center

Thermospheric variations as an indicator of magnetic storm heating and circulation

In situ measurements of the neutral constituent densities and temperature were made at 200 km by the open source mass spectrometer on the AE-D satellite during a rapid onset of the magnetic activity that occurred in January 1976. At high latitudes a 340 K temperature increase was accompanied by an increase in N2 and O2 concentrations, a decrease in He concentration, and a variable response in O concentration. At low latitudes, the rise in temperature was smaller, however; all constituent densities increased. It is concluded that the observed variations are consistent with heating and upward winds at high latitudes, meridional flow towards lower latitudes and subsidence near the equator.

Potter, W. E.

Comparison of Mixing Calculations for Reacting and Non-Reacting Flows in a Cylindrical Duct

A production 3-D elliptic flow code has been used to calculate non-reacting and reacting flow fields in an experimental mixing section relevant to a rich burn/quick mix/lean burn (RQL) combustion system. A number of test cases have been run to assess the effects of the variation in the number of orifices, mass flow ratio, and rich-zone equivalence ratio on the flow field and mixing rates. The calculated normalized temperature profiles for the non-reacting flow field agree qualitatively well with the normalized conserved variable isopleths for the reacting flow field indicating that non-reacting mixing experiments are appropriate for screening and ranking potential rapid mixing concepts. For a given set of jet momentum-flux ratio, mass flow ratio, and density ratio (J, MR, and DR), the reacting flow calculations show a reduced level of mixing compared to the non-reacting cases. In addition, the rich-zone equivalence ratio has noticeable effect on the mixing flow characteristics for reacting flows.

Oechsle, V. L.

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE

Study Proposal for the Possible Use of ISS as an Aerodynamic Facility for Aerospace Applications

In order to determine the correct design parameters for an orbital transfer vehicle (OTV) to be used in conjunction with the envisaged space station system (SSS) it is essential to know the aerodynamic coefficients in the translational flow regime of the Earth's atmosphere at approximately 80 to 200 km. Because of the inherent difficulties relating to the duplication of the abovesaid translational flow regime in a ground based aerodynamic facility, another means of making this determination had to be developed. The proposed solution is the exploitation of the tether satellite system (TSS). By employing it as a spaceborne variable low density wind tunnel, the TSS appears to be a very appealing tool for such gas dynamic research.

Buonjiolno, C.

Aerodynamic heating rate distributions induced by trailing edge controls on hypersonic aircraft configurations at Mach 8

Aerodynamic surface heating rate distributions in three dimensional shock wave boundary layer interaction flow regions are presented for a generic set of model configurations representative of the aft portion of hypersonic aircraft. Heat transfer data were obtained using the phase change coating technique (paint) and, at particular spanwise and streamwise stations for sample cases, by the thin wall transient temperature technique (thermocouples). Surface oil flow patterns are also shown. The good accuracy of the detailed heat transfer data, as attested in part by their repeatability, is attributable partially to the comparatively high temperature potential of the NASA-Langley Mach 8 Variable Density Tunnel. The data are well suited to help guide heating analyses of Mach 8 aircraft, and should be considered in formulating improvements to empiric analytic methods for calculating heat transfer rate coefficient distributions.

Kaufman, L. G., II

Assessment of closure coefficients for compressible-flow turbulence models

A critical assessment is made of the closure coefficients used for turbulence length scale in existing models of the transport equation, with reference to the extension of these models to compressible flow. It is shown that to satisfy the compressible 'law of the wall', the model coefficients must actually be functions of density gradients. The magnitude of the errors that result from neglecting this dependence on density varies with the variable used to specify the length scale. Among the models investigated, the k-omega model yields the best performance, although it is not completely free from errors associated with density terms. Models designed to reduce the density-gradient effect to an insignificant level are proposed.

Huang, P. G.