Search NASA⌕ Search

SEARCH · Search NASA

Results for “vibrator array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cryogenic Limb Array Etalon Spectrometer (CLAES) - Experiment description

The CLAES measurement concept, instrument design, and performance are presented, and the scientific capabilities and measurement modes are discussed. The CLAES experiment involves remote measurement of earth-limb emission spectra. Characteristic vibration-rotation line spectral radiances are obtained between 3.5 and 13 microns and inverted through an iterative relaxation process to yield pressure, temperature, and species mixing ratio. The UARS limb-viewing instruments, including CLAES, combined with the 57-deg orbit inclination, allow for measurements to 80-deg latitudes. CLAES requires high spectral resolution and high radiometric sensitivity to isolate and accurately measure weak emissions from trace species such as HCl and NO against intense backgrounds from abundant emitters such as CO2, H2O, and O3. Accuracy and precision of retrieved quantities, observational modes, and calibration modes are also discussed.

Roche, Aidan E.↗

Analytical nonadiabatic coupling and state-specific energy gradient for the crystal field Hamiltonian describing lanthanide single-ion magnets

Paramagnetic molecules with a metal ion as an electron spin center are promising building blocks for molecular qubits and high-density memory arrays. However, fast spin relaxation and decoherence in these molecules lead to a rapid loss of magnetization and quantum information. Nonadiabatic coupling (NAC), closely related to spin-vibrational coupling, is the main source of spin relaxation and decoherence in paramagnetic molecules at higher temperatures. Predicting these couplings using numerical differentiation requires a large number of computationally intensive ab initio or crystal field electronic structure calculations. To reduce computational cost and improve accuracy, we derive and implement analytical NAC and state-specific energy gradient for the ab initio parametrized crystal field Hamiltonian describing single-ion molecular magnets. Our implementation requires only a single crystal field calculation. In addition, the accurate NACs and state-specific energy gradients can be used to model spin relaxation using sophisticated nonadiabatic molecular dynamics, which avoids the harmonic approximation for molecular vibrations. To test our implementation, we calculate the NAC values for three lanthanide complexes. Finally, the predicted values support the relaxation mechanisms reported in previous studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗

Design and test of a High-Resolution EUV Spectroheliometer

The HiRES High-Resolution EUV Spectroheliometer is a sounding rocket instrument yielding very high spatial, spectral, and temporal resolution images of the solar outer atmosphere, on the basis of a 45-cm Gregorian telescope feeding a normal-incidence stigmatic EUV spectrometer with imaging multianode microchannel-array detector system, as well as an IR spectrometer with imaging CCD detector system. Attention is given to the expected performance of this system, including the effects of vibrational misalignments due to the sounding rocket flight environment.

Berger, Thomas E.↗

Interferometric Imaging of Titan's HC3N, H(13)CCCN, and HCCC(15)N

We present the first maps of cyanoacetylene isotopologues in Titan's atmosphere, including H(13)CCCN and HCCC(15)N, detected in the 0.9 mm band using the Atacama Large Millimeter/submillimeter array (ALMA) around the time of Titan's (southern winter) solstice in 2017 May. The first high-resolution map of HC3N in its v(sub 7) = 1 vibrationally excited state is also presented, revealing a unique snapshot of the global HC3N distribution, free from the strong optical depth effects that adversely impact the ground-state (v = 0) map. The HC3N emission is found to be strongly enhanced over Titan's south pole (by a factor of 5.7 compared to the north pole), consistent with rapid photochemical loss of HC3N from the summer hemisphere combined with production and transport to the winter pole since the 2015 April ALMA observations. The H(13)CCCN/HCCC(15)N flux ratio is derived at the southern HC3N peak, and implies an HC3N/HCCC(15)N ratio of 67 +/- 14. This represents a significant enrichment in 15N compared with Titan's main molecular nitrogen reservoir, which has a N-14/N-15 ratio of 167, and confirms the importance of photochemistry in determining the nitrogen isotopic ratio in Titan's organic inventory.

Cordiner, M. A.↗

Fiber Optic Strain Sensor for Planetary Gear Diagnostics

This paper presents a new sensing approach for helicopter damage detection in the planetary stage of a helicopter transmission based on a fiber optic strain sensor array. Complete helicopter transmission damage detection has proven itself a difficult task due to the complex geometry of the planetary reduction stage. The crowded and complex nature of the gearbox interior does not allow for attachment of sensors within the rotating frame. Hence, traditional vibration-based diagnostics are instead based on measurements from externally mounted sensors, typically accelerometers, fixed to the gearbox exterior. However, this type of sensor is susceptible to a number of external disturbances that can corrupt the data, leading to false positives or missed detection of potentially catastrophic faults. Fiber optic strain sensors represent an appealing alternative to the accelerometer. Their small size and multiplexibility allows for potentially greater sensing resolution and accuracy, as well as redundancy, when employed as an array of sensors. The work presented in this paper is focused on the detection of gear damage in the planetary stage of a helicopter transmission using a fiber optic strain sensor band. The sensor band includes an array of 13 strain sensors, and is mounted on the ring gear of a Bell Helicopter OH-58C transmission. Data collected from the sensor array is compared to accelerometer data, and the damage detection results are presented

Kiddy, Jason S.↗

Low-Environmental-Impact Monitoring of CO 2 Using Seismic Methods in North Dakota

Conference poster presented at American Association of Petroleum Geologists (AAPG) Carbon Capture, Utilization, and Storage (CCUS) Conference, Houston, Texas, March 28–30, 2022. In 2021, the Energy & Environmental Research Center initiated a multiyear research project associated with Red Trail Energy’s Carbon Capture and Storage Project. The research is based on the scalable automated sparse seismic array (SASSA), a lower-cost, less invasive seismic method that could replace the large-scale 3D seismic surveys by using four stationary seismic sources called surface orbital vibrators (SOVs) and a small number of seismic sensors deployed sparsely within the same 8-square-mile area investigated with a 3D seismic survey conducted in 2019.

01 COAL, LIGNITE, AND PEAT↗

Computerized symbolic manipulation in structural mechanics Progress and potential

Status and recent applications of computerized symbolic manipulation to structural mechanics problems are summarized. The applications discussed include; (1) generation of characteristic arrays of finite elements; (2) evaluation of effective stiffness and mass coefficients of continuum models for repetitive lattice structures; and (3) application of Rayleigh-Ritz technique to free vibration analysis of laminated composite elliptic plates. The major advantages of using computerized symbolic manipulation in each of these applications are outlined. A number of problem areas which limit the realization of the full potential of computerized symbolic manipulation in structural mechanics are examined and some of the means of alleviating them are discussed.

Noor, A. K.↗

Multiwall TPS - An emerging concept

Research on titanium multiwall used for thermal protection is reviewed. Continuing analytical and experimental studies yielding a fundamental understanding of the thermal and structural performance of the basic multiwall concept are presented noting that central to this understanding is a knowledge of the extensional behavior of the dimpled sheets since the thinner flat sheets will buckle and be relatively ineffective in supporting compressive loads. Results from radiant heating, aerothermal, vibration, acoustic and lightning strike tests are described as part of an effort to verify the performance of multiwall tiles under representative operating conditions. Flight tests of a large array of tiles are also planned as part of an orbiter experiments program. The research effort is being extended from flat all-titanium multiwall configurations limited to temperatures below 810 K to curved surfaces and higher temperature versions. Multi-wall concepts are found to offer the durability of metallic systems and to be mass competitive with the insulation system currently used on the Space Shuttle Orbiter.

Shideler, J. L.↗

Multispecies CARS measurements in turbulent combustion

A coherent anti-Stokes Raman scattering (CARS) instrument was upgraded to more accurately measure the number density of oxygen molecules. This instrument is designed to simultaneously measure nitrogen number density, oxygen number density, and the ro-vibrational temperature of nitrogen. The CARS is a nonintrusive diagnostic technique which utilizes a pulsed Nd:YAG laser, broadband dye lasers, a complex optical system, and an intensified photodiode array detector to sample hostile combustion environments. Measurements were made in a flame produced by a coaxial subsonic diffusion hydrogen-air burner. These data were used as a data base for comparison with the results of two separate computational fluid dynamics calculations. Complications which had arisen in previous studies with regard to interpretation of the oxygen data were eliminated.

Antcliff, Richard R.↗

Configurable Multi-Purpose Processor

Advancements in technology have allowed the miniaturization of systems used in aerospace vehicles. This technology is driven by the need for next-generation systems that provide reliable, responsive, and cost-effective range operations while providing increased capabilities such as simultaneous mission support, increased launch trajectories, improved launch, and landing opportunities, etc. Leveraging the newest technologies, the command and telemetry processor (CTP) concept provides for a compact, flexible, and integrated solution for flight command and telemetry systems and range systems. The CTP is a relatively small circuit board that serves as a processing platform for high dynamic, high vibration environments. The CTP can be reconfigured and reprogrammed, allowing it to be adapted for many different applications. The design is centered around a configurable field-programmable gate array (FPGA) device that contains numerous logic cells that can be used to implement traditional integrated circuits. The FPGA contains two PowerPC processors running the Vx-Works real-time operating system and are used to execute software programs specific to each application. The CTP was designed and developed specifically to provide telemetry functions; namely, the command processing, telemetry processing, and GPS metric tracking of a flight vehicle. However, it can be used as a general-purpose processor board to perform numerous functions implemented in either hardware or software using the FPGA s processors and/or logic cells. Functionally, the CTP was designed for range safety applications where it would ultimately become part of a vehicle s flight termination system. Consequently, the major functions of the CTP are to perform the forward link command processing, GPS metric tracking, return link telemetry data processing, error detection and correction, data encryption/ decryption, and initiate flight termination action commands. Also, the CTP had to be designed to survive and operate in a launch environment. Additionally, the CTP was designed to interface with the WFF (Wallops Flight Facility) custom-designed transceiver board which is used in the Low Cost TDRSS Transceiver (LCT2) also developed by WFF. The LCT2 s transceiver board demodulates commands received from the ground via the forward link and sends them to the CTP, where they are processed. The CTP inputs and processes data from the inertial measurement unit (IMU) and the GPS receiver board, generates status data, and then sends the data to the transceiver board where it is modulated and sent to the ground via the return link. Overall, the CTP has combined processing with the ability to interface to a GPS receiver, an IMU, and a pulse code modulation (PCM) communication link, while providing the capability to support common interfaces including Ethernet and serial interfaces boarding a relatively small-sized, lightweight package.

Valencia, J. Emilio↗

Silicon Micromachined Sensor for Broadband Vibration Analysis

The development of a family of silicon based integrated vibration sensors capable of sensing mechanical resonances over a broad range of frequencies with minimal signal processing requirements is presented. Two basic general embodiments of the concept were designed and fabricated. The first design was structured around an array of cantilever beams and fabricated using the ARPA sponsored multi-user MEMS processing system (MUMPS) process at the Microelectronics Center of North Carolina (MCNC). As part of the design process for this first sensor, a comprehensive finite elements analysis of the resonant modes and stress distribution was performed using PATRAN. The dependence of strain distribution and resonant frequency response as a function of Young's modulus in the Poly-Si structural material was studied. Analytical models were also studied. In-house experimental characterization using optical interferometry techniques were performed under controlled low pressure conditions. A second design, intended to operate in a non-resonant mode and capable of broadband frequency response, was proposed and developed around the concept of a cantilever beam integrated with a feedback control loop to produce a null mode vibration sensor. A proprietary process was used to integrat a metal-oxide semiconductor (MOS) sensing device, with actuators and a cantilever beam, as part of a compatible process. Both devices, once incorporated as part of multifunction data acquisition and telemetry systems will constitute a useful system for NASA launch vibration monitoring operations. Satellite and other space structures can benefit from the sensor for mechanical condition monitoring functions.

Gutierrez, Adolfo↗

First Observation of Multiphonon 𝛾-Vibrations in an Odd-Odd Nuclear System

Here, the identification of the first multiphonon 𝛾-vibrational bands in an odd-odd neutron-rich nucleus of the nuclear chart is presented. These high-spin structures of hard to access $^{104}_{41}\textrm{Nb}_{63}$, produced in fission, were studied by combining a spectrometer with isotopic resolution coupled to a 𝛾-ray tracking array and independently from high-fold 𝛾 coincidence measurements. Triaxial projected shell model calculations for the high-spin states are in good agreement with the measured observables for the yrast, one-phonon, and two-phonon 𝛾 bands. The possibility of an oblate shape of an isomeric state and coexistence of triaxial and oblate configurations is investigated from the decay of the 141 keV isomer. The present Letter illustrates the robustness of vibration excitations in the presence of an odd valence proton and neutron as well as the possibly coexisting shapes beyond the 𝑁 = 60 transitional region.

Wang, E. H. [Shandong Univ., Jinan (China); Vander↗

Fuselage shell and cavity response measurements on a DC-9 test section

A series of fuselage shell and cavity response measurements conducted on a DC-9 aircraft test section are described. The objectives of these measurements were to define the shell and cavity model characteristics of the fuselage, understand the structural-acoustic coupling characteristics of the fuselage, and measure the response of the fuselage to different types of acoustic and vibration excitation. The fuselage was excited with several combinations of acoustic and mechanical sources using interior and exterior loudspeakers and shakers, and the response to these inputs was measured with arrays of microphones and accelerometers. The data were analyzed to generate spatial plots of the shell acceleration and cabin acoustic pressure field, and corresponding acceleration and pressure wavenumber maps. Analysis and interpretation of the spatial plots and wavenumber maps provided the required information on modal characteristics, structural-acoustic coupling, and fuselage response.

Simpson, M. A.↗

Response of a Rotating Propeller to Aerodynamic Excitation

The flexural vibration of a rotating propeller blade with clamped shank is analyzed with the object of presenting, in matrix form, equations for the elastic bending moments in forced vibration resulting from aerodynamic forces applied at a fixed multiple of rotational speed. Matrix equations are also derived which define the critical speeds end mode shapes for any excitation order and the relation between critical speed and blade angle. Reference is given to standard works on the numerical solution of matrix equations of the forms derived. The use of a segmented blade as an approximation to a continuous blade provides a simple means for obtaining the matrix solution from the integral equation of equilibrium, so that, in the numerical application of the method presented, the several matrix arrays of the basic physical characteristics of the propeller blade are of simple form, end their simplicity is preserved until, with the solution in sight, numerical manipulations well-known in matrix algebra yield the desired critical speeds and mode shapes frame which the vibration at any operating condition may be synthesized. A close correspondence between the familiar Stodola method and the matrix method is pointed out, indicating that any features of novelty are characteristic not of the analytical procedure but only of the abbreviation, condensation, and efficient organization of the numerical procedure made possible by the use of classical matrix theory.

Arnoldi, Walter E.↗

An Algorithm for Synthesizing Mass and Stiffness Matrices from Experimental Vibration Modes

An algorithm is described for synthesizing the mass and stiffness matrices from experimentally derived modal data in a way that preserves the physical significance of the individual mass and stiffness elements. The mass and stiffness matrices are derived for a rollup solar array example, and are then used to define the modal response of a modified array.

Ross, R. G., Jr.↗

Ground Vibrational State SiO Emission in the VLA BAaDE Survey

Using a subsample of the Bulge Asymmetries and Dynamical Evolution (BAaDE) survey of stellar SiO masers, we explore the prevalence and characteristics of {sup 28}SiO J = 1 − 0, v = 0 emission. We identify 90 detections of maser, thermal, or composite {sup 28}SiO J = 1 − 0, v = 0 emission out of approximately 13,000 candidate spectra from the National Science Foundation’s Karl G. Jansky Very Large Array (VLA). We find that the detected sources are likely asymptotic giant branch stars belonging to a bright, foreground Milky Way stellar disk population. For the 32 sources showing thermal components, we extract values for outflow velocity by fitting thermal line profiles. We find a range of circumstellar envelope expansion velocities, and compare to previously recorded OH and CO expansion velocities. This preliminary survey is already the largest study of stellar ground vibrational state SiO masers to date, and will be expanded to include the entire VLA BAaDE data set when data reduction for the 18,988 target sources is completed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCM and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.

Huque, Naeem↗