Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Doping- and Strain-Dependent Electrolyte-Gate-Induced Perovskite to Brownmillerite Transformation in Epitaxial La 1– x Sr x CoO 3–δ Films

Much recent attention has focused on the voltage-driven reversible topotactic transformation between the ferromagnetic metallic perovskite (P) SrCoO 3-δ and oxygen-vacancy-ordered antiferromagnetic insulating brownmillerite (BM) SrCoO 2.5 . This is emerging as a paradigmatic example of the power of electrochemical gating (using, e.g., ionic liquids/gels), the wide modulation of electronic, magnetic, and optical properties generating clear application potential. SrCoO 3 films are challenging with respect to stability, however, and there has been little exploration of alternate compositions. Here, we present the first study of ion-gel-gating-induced P. BM transformations across almost the entire La 1-x SrxCoO 3 phase diagram (0 ≤ x ≤ 0.70), under both tensile and compressive epitaxial strain. Electronic transport, magnetometry, and operando synchrotron X-ray diffraction establish that voltage-induced P → BM transformations are possible at essentially all x, including x ≤ 0.50, where both P and BM phases are highly stable. Under small compressive strain, the transformation threshold voltage decreases from approximately +2.7 V at x = 0 to negligible at x = 0.70. Both larger compressive strain and tensile strain induce further threshold voltage lowering, particularly at low x. The P → BM threshold voltage is thus tunable, via both composition and strain. At x = 0.50, voltage-controlled ferromagnetism, transport, and optical transmittance are then demonstrated, achieving Curie temperature and resistivity modulations of similar to 220 K and at least 5 orders of magnitude, respectively, and enabling estimation of the voltage-dependent Co valence. The results are analyzed in the context of doping- and strain-dependent oxygen vacancy formation energies and diffusion coefficients, establishing that it is thermodynamic factors, not kinetics, that underpin the decrease in the threshold voltage with x, that is, with increasing formal Co valence. These findings substantially advance the practical and mechanistic understanding of this voltage-driven transformation, with fundamental and technological implications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduction of Effective Carrier Density and Charge Collection Efficiency in SiC Devices Due to Radiations

6H-Silicon Carbide (SiC) diodes were fabricated and irradiated with Co-60 gamma-rays, 1 MeV electrons, and 65 MeV protons. After the radiation damage was introduced in devices, the Charge Collection Efficiency (CCE) was evaluated by using the Transient Ion Beam Induced Current (TIBIC) system. The effective carrier density was also estimated from Capacitance-Voltage (C-V) characteristics. It was found that both the CCE and the effective carrier density decrease with increase in the fluence. We discuss whether Non-Ionizing Energy Loss (NIEL) analysis can estimate the degradation in these parameters. Results from this study suggest that the damage factors of these parameters in SiC can be scaled by the NIEL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Specifying angular reference for robust three-phase state estimation

While the phase angle of any of the bus voltages can be chosen as the angular reference in the state estimation formulation of positive sequence networks, the same approach does not readily extend to three-phase network state estimation problem. It is commonly assumed that there is at least one bus where the bus voltages are perfectly balanced with phase angles displaced ±120° and these balanced three phase voltages are used as the three-phase reference in solving the three-phase state estimation problem. This assumption may be quite realistic in transmission networks, and for distribution networks with a strong transmission system connection. However, it might not be realistic to assume existence of a perfectly balanced reference bus in today’s distribution systems with ever increasing penetration of renewable sources or for isolated operation of microgrids. In this paper, a novel state estimation formulation will be presented which facilitates correct solution irrespective of the existence of buses with perfectly balanced voltages. The new formulation is general, and lends itself to bad data processing. It yields accurate results in any three-phase power system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. The performance of the method is validated using the IEEE 123 bus three-phase system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of plasma on gas flow and air concentration in the effluent of a pulsed cold atmospheric pressure helium plasma jet

In this work, we report on the flow effects induced by a nanosecond pulsed helium cold atmospheric pressure plasma jet impinging on a glass substrate. Herein, gas temperature measurements have been performed using optical emission spectroscopy including rotational spectra of OH(A-X) (0,0) and N 2 (C-B) (0,0) and resonance broadening of a helium emission line at 667.8 nm. The measured increase in gas temperature was less than 15 K. We have measured the air concentration distribution in the jet effluent by means of Rayleigh scattering exploiting the large difference in Rayleigh cross-section of air and helium. The obtained results show that the plasma causes a broadening of the helium channel suggesting an enhanced gas velocity and mixing with the ambient air. The impact of the plasma on the jet effluent is polarity dependent and is larger in the case of positive applied voltage pulses. Using an estimation of the increased gas velocity required to obtain the observed air concentrations, we have shown that both gas heating and electrohydrodynamic (EHD) forces related to the propagation of an ionization front are not causing the observed phenomena. The surface charge which can exist for a much longer time than the duration of the applied voltage pulse is the primary cause of the EHD forces on the bulk charges which lead to significant different air concentration profiles in the jet effluent for plasma on and off.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport properties of La{sub 2/3}Sr{sub 1/3}MnO{sub 3}/LaAlO{sub 3}/Pt tunnel junctions

Magnetotransport properties of La{sub 2/3}Sr{sub 1/3}MnO{sub 3}/LaAlO{sub 3}/Pt tunnel junctions have been thoroughly analyzed, as a function of temperature and magnetic field, to test the suitability of LaAlO{sub 3} for insulating barriers and spin injection processes. The insulating behavior of LaAlO{sub 3} maintained down to 1–2 nm (corresponding to 4–5 unit cells) renders this material useful as tunnel barrier. The temperature dependence of the junction resistance, R(T), down to 200 K confirms direct tunneling as the dominant conduction channel. The barrier parameters of the junctions, φ{sub 0} and s, are estimated using Simmons' model in the intermediate voltage range. The energy of the barrier was estimated to be φ{sub 0} ∼ 0.4 eV at room temperature. The dependence of R(T) and φ{sub 0} on the magnetic field shows an anisotropic tunneling magnetoresistance of ∼4% at low T when changing the direction of the magnetization with respect to the current flow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Principles Determination of the Potential-of-Zero-Charge in an Alumina-Coated Aluminum/Water Interface Model for Corrosion Applications

The surfaces of most metals immersed in aqueous electrolytes have a several-nanometer-thick oxide/hydroxide surface layer. This gives rise to the existence of both metal|oxide and oxide|liquid electrotlyte interfaces, and makes it challenging to correlate atomic length-scale structures with electrochemical properties such the potential-of-zero-charge (PZC). The PZC has been shown to be correlated the onset potential for pitting corrosion. Here, we conduct large-scale Density Functional Theory and ab initio molecular dynamics to calculate the PZC of a Al(111)| γ -Al 2 O 3 (110)| water double-interface model within the context of aluminum corrosion. By partitioning the multiple interfaces involved into binary components with additive contributions to the overall work function and voltage, we predict the PZC to be -1.53 V vs SHE for this model. Furthermore, we calculate the orbital energy levels of defects like oxygen vacancies in the oxide, which are critical parameters in theories associated with pitting corrosion. We predict that the Fermi level at the PZC lies above the impurity defect levels of the oxygen vacancies, which are therefore uncharged at the PZC. From the PZC estimate, we predict the voltage needed to create oxygen vacancies with net positive charges within a flatband approximation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Stage Cryogenic HEMT-Based Amplifier for Low-Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$ (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1–100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance (~ 1.6 pF) HEMT is used as a buffer stage at T = 10 mK to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance (~ 200 pF) HEMT amplifier stage at T = 4 K. Importantly, the design of this amplifier makes it usable with any insulating material—allowing for rapid prototyping of a variety of novel detector materials. Here, we present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

47 OTHER INSTRUMENTATION↗

Efficient charge transfer and field-induced tunneling transport in hybrid composite device of organic semiconductor and cadmium telluride quantum dots

Temperature and photo-dependent current–voltage characteristics are investigated in thin film devices of a hybrid-composite comprising of organic semiconductor poly(3,4-ethylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) and cadmium telluride quantum dots (CdTe QDs). A detailed study of the charge injection mechanism in ITO/PEDOT:PSS-CdTe QDs/Al device exhibits a transition from direct tunneling to Fowler–Nordheim tunneling with increasing electric field due to formation of high barrier at the QD interface. In addition, the hybrid-composite exhibits a huge photoluminescence quenching compared to aboriginal CdTe QDs and high increment in photoconductivity (∼ 400%), which is attributed to the charge transfer phenomena. The effective barrier height (Φ{sub B} ≈ 0.68 eV) is estimated from the transition voltage and the possible origin of its variation with temperature and photo-illumination is discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A New Multi-Scale State Estimation Framework for the Next Generation of Power Grid EMS

Accurate system state information under various operation conditions is a prerequisite for power grid monitoring and efficient control. To achieve that goal, a new multi-scale state estimation framework is proposed, paving the way for the development of next generation of energy management system (EMS). The developed framework consists of three key components, namely the static state estimation (SSE) module, the dynamic state estimation (DSE) module, the interfaces and switching logics between the two modules. Specifically, the singular spectrum analysis (SSA)-based change point detection approach is developed to monitor the system continuously. If no event is detected by the SSA, the robust SSE using both SCADA and PMU measurements is executed. Otherwise, the event is declared and the results from SSE are used to derive the initial condition for DSE. During the transient process, only PMU-based DSE is executed for system monitoring and it will be terminated when SSA does not detect any change point of the system. After that, the DSE results are forwarded for SSE initialization and bus voltage magnitude and angle estimations. Simulation results carried out on the IEEE 39-bus system demonstrate the effectiveness and benefits of the proposed framework.

Power system state estimation, energy management s↗

Improved fast vertical control in KSTAR

Fast vertical control of shaped plasmas is essential for the successful realization of plasma operation near the limit of vertical control to achieve maximum confinement and stable, disruption free operation. In KSTAR, the normal conducting in-vessel vertical control coil (IVC coil) is employed to respond to vertical transients much faster than the superconducting coils are capable. The power supply for the IVC coil is capable of responding in a time commensurate with the expected vertical growth rates on KSTAR. The diagnostics used for the fast vertical control since the first operation with shaped plasmas in KSTAR, however, have a low signal-to-noise ratio which limits the gains that can be used successfully in the proportional and derivative control loops and thus the speed of the control loop. The successful use of relative flux for the Z-position estimate and of the loop voltage difference from a pair of up-down symmetric loops to provide sensitive and less noisy vertical estimate will be discussed. In addition, the control loop for the IVC coil is decoupled from the slow motion controlled by the superconducting coils using a high-pass filter in the control software. Lastly the noticeable improvement in plasma control for plasmas near the vertical stability limit will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating Customer Impact of Volt-Watt Using Only Smart Meter Voltage Data

The autonomous inverter control mode known as volt-watt control can be useful as a backstop against high customer voltages outside of the ranges specified in ANSI C84.1 (i.e. above 1.05-1.06 per unit). Volt-watt control mitigates high voltages by directly reducing the active power output of a distributed energy resource based on local voltage measurements. Therefore volt-watt control also can impact the energy produced by the DER (e.g. PV system), especially for customers with persistently high voltages, and in such cases it is difficult to determine exactly how much the DER has been curtailed because it is not generally known exactly how much energy the PV system could have produced. These slides propose a relatively simple method of estimating the DER's energy curtailment using only data from the utility advanced metering infrastructure (AMI) data). The method proves surprisingly accurate when validated against detailed quasi-static time-series simulations and against limited field data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BMINN: Learning chemical potentials and parameters from voltage data for multi-phase battery modeling

Free-energy landscapes and chemical potentials govern the dynamics of phase transitions, transport, and stability in functional materials, yet they remain experimentally inaccessible under realistic operating conditions. Here we introduce a Bayesian model-integrated neural network (BMINN) that embeds physics-based formulations of non-autonomous partial differential-algebraic equations into probabilistic learning. This approach reconstructs hidden thermodynamics directly from macroscopic current-voltage data, providing quantitative access to metastable states, staging transitions, and energy barriers without synchrotron probes. Demonstrated on lithium-graphite electrodes, BMINN recovers full Gibbs free-energy landscapes with fidelity validated against operando X-ray diffraction. The framework generalizes across dynamical regimes, enabling accurate voltage prediction, internal state estimation, and inference of governing parameters. Beyond batteries, BMINN exemplifies a broadly applicable strategy for learning missing physics in multiphase, non-equilibrium systems, offering a new pathway to uncover hidden thermodynamic functions across condensed matter and materials physics.

25 ENERGY STORAGE↗

Mid- to long-wave infrared computational spectroscopy with a graphene metasurface modulator

In recent years there has been much interest concerning the development of modulators in the mid- to long-wave infrared, based on emerging materials such as graphene. These have been frequently pursued for optical communications, though also for other specialized applications such as infrared scene projectors. Here we investigate a new application for graphene modulators in the mid- to long-wave infrared. We demonstrate, for the first time, computational spectroscopy in the mid- to long-wave infrared using a graphene-based metasurface modulator. Furthermore, our metasurface device operates at low gate voltage. To demonstrate computational spectroscopy, we provide our algorithm with the measured reflection spectra of the modulator at different gate voltages. We also provide it with the measured reflected light power as a function of the gate voltage. The algorithm then estimates the input spectrum. We show that the reconstructed spectrum is in good agreement with that measured directly by a Fourier transform infrared spectrometer, with a normalized mean-absolute-error (NMAE) of 0.021.