Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigation of long-term light stability of negative charge injected into oxide-nitride-oxide passivation stack of crystalline silicon solar cells

A negatively charged oxide-nitride-oxide stack for field-effect passivation of crystalline silicon solar cells is discussed. The negative charge was injected into the stack by a plasma charge injection technology. Charge stability was studied by exposing samples to AM1.5 simulation visible light and full-spectrum light at temperatures ranging from 55 to 78 °C for up to 300 h. Charge injection and loss were quantified based on shifts in the flatband voltage of capacitance–voltage curves measured with a mercury probe. The most probable mechanism of charge loss was found to be diffusion of negative charged hydrogen atoms through nitride and bottom oxide. The optimum recipe for each layer of the stack was investigated to minimize the loss of injected charge. The flatband voltage decay of the optimized stack was found to fit a power-law trend, suggesting the dispersive transport of hydrogen atoms with a dispersion parameter of ~0.06–0.07. The optimized stack is projected to maintain a negative charge density of about 3.6 × 10 12 cm –2 or more after 25 years of field operation in an environment such as Arizona, which would be sufficient for field-effect passivation under one-sun illumination. Furthermore, the high stability of the negative injected charge makes the plasma charging technology a safer and lower cost alternative to Al 2 O 3 -passivation technology commonly used to passivate p-type surfaces.

14 SOLAR ENERGY↗

Electrochemical Measurement of Water Transport Numbers in Anion-Exchange Membranes

Anion-exchange membranes (AEMs) are a possible replacement for perfluorosulfonic-acid membranes in energy-conversion devices, primarily due to the hydroxide mobile ion allowing the devices to operate in alkaline conditions with less expensive electrocatalysts. However, the transport properties of AEMs remain understudied, especially electro-osmosis. In this work, an electrochemical technique, where the open-circuit voltage is measured between two ends of a membrane maintained at different relative humidities, is used to determine the water transport number of various ionomers, including Versogen and Sustainion AEMs and Nafion cation-exchange membrane (CEM), as a function of water content and temperature. In addition, the CEMs and AEMs are examined in differing single-ion forms, specifically proton and sodium (CEM) and hydroxide and carbonate (AEM). Carbonate-form AEMs have the highest transport number (∼11), followed by sodium-form CEMs (∼8), hydroxide-form AEMs (∼6), and proton-form CEMs (∼3). Finally, a multicomponent transport model based on the Stefan-Maxwell-Onsager framework of binary interactions is used to develop a link between water transport number and water-transport properties, extracting a range for the unmeasured membrane water permeability of Versogen as a function of water content.

30 DIRECT ENERGY CONVERSION↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classic state estimation algorithms. In this paper, a new method, called the pruned physics-aware neural network (P2N2), is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one- year smart meter data of load consumptions for three-phase power flow is developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS in terms of data redundancy and estimation accuracy.

distribution system state estimation↗

Investigations of room temperature multiferroic and magneto-electric properties of (1-Φ) PZTFT-Φ CZFMO particulate composites

Multiferroic composites consisting of a single-phase multiferroic [0.6(PbZr 0.53 Ti 0.47 O 3 )-0.4(PbFe 0.5 Ta 0.5 )O 3 ] as a matrix and a magnetostrictive phase (Co 0.6 Zn 0.4 Fe 1.7 Mn 0.3 O 4 ) dispersed in the matrix are fabricated via hybrid synthesis technique. The structure and surface morphology studies using x-ray diffraction and field emission scanning electron microscopy techniques indicate the formation of 3-0 type particulate composites. Coexistence of soft-magnetic behavior and ferroelectric characteristics are confirmed for composites from magnetization vs magnetic field (M–H) and polarization vs electric field (P–E) measurements, respectively. Magneto-dielectric (MD) measurement shows significant changes in the dielectric properties with the application of a magnetic field, indicating the existence of strong MD behavior. The biquadratic nature of magneto-electric (ME) coupling is described by the Landau free energy equation arising from the strain transfer at the interfaces between the constituent phases. The direct magneto-electric voltage coefficient measurement also confirms very strong coupling between ferroelectricity and magnetism and supports the strain-mediated magneto-electric effect in composites. The Φ = 0.3 composite exhibits the maximum ME coefficient of 20.72 mV/cm Oe with M S = 24.62 emu/g, H C = 59.66 Oe, and piezoelectric coefficient value d 33 = 19 pC/N. In conclusion, the strong magneto-electric effect along with low dielectric loss at room temperature in these composites suggests their suitability for multifunctional magneto-electric device applications such as magnetic sensors, etc.

36 MATERIALS SCIENCE↗

Event Screening Methods for the Eastern Interconnection Situational Awareness and Monitoring System (ESAMS)

The Eastern Interconnection Situational Awareness and Monitoring System (ESAMS) is a tool developed to explore the applications and advantages of sharing phasor measurement unit (PMU) data among operating entities. An initial conclusion from testing was that detected events required further screening before being reported to ensure that events would be of interest to system operators. The methods described in this report were integrated into ESAMS to meet this need. First, an event is screened for whether the change in voltage angle measurements indicates that the detected disturbance is sufficiently large. Next, an event is classified to determine if it was related to a loss of generation. Finally, a neural network is used to determine if the system’s response to the disturbance is normal or abnormal. These methods were tested with one month of field-measured PMU data. Results indicate that the additional information provided by these additional screening tools will improve selection of events for inclusion in the daily event reports automatically generated by ESAMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks: Preprint

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classical state estimation algorithms. In this paper, a new method so-called pruned physics-aware neural network (P2N2) is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one-year smart meter data of load consumptions for threephase power flow is developed to generate the measurement and voltage state data. The IEEE 123 node system is selected as the test network to benchmark the proposed algorithm against the classical weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS, in terms of data redundancy and estimation accuracy.

distribution systems state estimation↗

Self-potential tomography preconditioned by particle swarm optimization—Self-potential monitoring and streamflow data acquired March 26–September 14, 2023 at East Fork Poplar Creek near Oak Ridge Tennessee

This data release contains self-potential (SP) monitoring data measured on the flood plain of East Fork Poplar Creek (East Fork) in Oak Ridge, Tennessee and streamflow data measured at streamgage EFK5.4 about 310 meters upstream from the SP monitoring site. Additionally, forward and inverse numerical modeling scripts used to model the electrical-potential field on the East Fork flood plain are provided. SP monitoring data included in this data release were measured at 39 different data-collection points on the east flood plain; 30 points were spaced 3-m apart along an 87-m profile parallel to the edge of the streambank, and 9 points were spaced 5-m apart along a 40-m profile approximately perpendicular to the streambank. The two profiles of SP data-collection points intersected at the approximate midpoint of the profile parallel to the streambank. Transient voltages were measured at each data-collection point every 60 seconds between 16:13 Eastern Standard Time (EST) on March 26, 2023, and 11:41 EST on September 14, 2023. Streamflow data included in this data release overlap the time-period of self-potential monitoring and were measured every 900 seconds between 16:23 on March 26, 2023, and 23:53 on September 14, 2023.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Transverse Resistance for Stacks of Non-insulated REBCO Tapes

Transverse resistance among adjacent conductors is a key parameter to calculate AC losses in superconducting cables with non-insulated conductors. The transverse pressure insert (TPI) previously developed and used at Fermilab was modified to measure transverse resistance of stacks made of non-insulated REBCO tapes as a function of transverse pressure at liquid nitrogen temperature. Pressure up to 322 MPa was applied with a hydraulic cylinder. A small current up to 10 A was flown in the stack sample through REBCO tape leads spliced above and below the stack. The latter had a bending radius larger than 6 mm to prevent the critical current degradation in REBCO leads. The voltage was measured just outside the compressed area. Stack samples included stacks of bare 4-mm wide REBCO tapes, as well as REBCO tapes alternated with 4-mm wide stainless-steel ribbons of 40 μm and 30 μm of thickness. We herein present the results of these transverse resistance measurements. Results show a stronger dependence on pressure for smaller pressure vs. larger ones. Also, of the two components of contact resistance, i.e. contact and bulk, the latter was negligible.

Tamagnini, E. [Turin Polytechnic]↗

Measurements of the electron energy distribution function in partially magnetized low temperature plasmas

While Langmuir probes (LPs) are relatively simple and inexpensive plasma diagnostics for the electron density, temperature, and the electron energy distribution function (EEDF), the interpretation of the measured current–voltage (I–V) characteristic is complicated considerably by the presence of a magnetic field. In regimes where the electron gyroradius is comparable to the probe radius, the electron flux to the probe surface is retarded by reduced mobility across field lines and can no longer be described by a thermal model. Predicting the current collected by the probe in these regimes requires accurate estimates of the plasma diffusion coefficients, which are usually difficult to obtain. In this work, we measure electron energy distribution functions in E×B plasmas with magnetized electrons and non-magnetized ions in argon and krypton gases, using both a LP and laser Thomson scattering (LTS) at various magnetic fields. Using the LTS measurements to provide a robust benchmark for comparison, we compare existing theories describing the flux to the probe under magnetized conditions. We find that even when the electron gyroradius associated with the effective electron temperature is small compared to the probe radius, the EEDF computed using classical probe theory is still robust at energies higher than the energy at which the gyroradius becomes larger than the probe size. For plasmas that are not strongly non-Maxwellian, we formulate a method to extract robust density and temperature measurements using physics-informed fitting techniques to analyze EEDFs computed using classical theory.

Devin, E. G. [Princeton Plasma Physics Laboratory ↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anodic Interfacial Evolution in Extremely Fast Charged Lithium-Ion Batteries

Interfacial reaction mechanisms at the anode/separator interface play a central role in the performance and safety of lithium-ion batteries during fast charging. We report a mechanistic study on the evolution and interactions of the aging mechanisms at the anode/separator interface in lithium cobalt oxide/graphite pouch cells charged with variable charging rates (1–6C) over 10 cycles. In situ electrochemical measurements, including voltage relaxation, Coulombic efficiency, and direct current internal resistance, indicated an incremental lithium loss until the C rates were ≤5C. A substantial capacity fade is observed in the first few cycles of fast charging, but the magnitude of capacity fade progressively diminishes with the number of cycles, indicating a suppression in the lithium deposition mechanism. Post-mortem film thickness, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) analyses were performed to elucidate the evolution of electrolyte decomposition, the solid–electrolyte interface (SEI), lithium plating, and film fracture mechanisms with C rate. XPS measurements confirmed an increasing lithium concentration in an SEI film with an increase in the C rate. SEM images showed a growth of dendritic lithium on the anode surface from 1C to 3C. Precrack formation leading to an interfacial film fracture was observed at higher C rates. Furthermore, a differential analysis of the discharge capacity indicated a possible two-phase delithiation from the anode and reduced cathodic lithiation due to lithium loss at high C rates.

36 MATERIALS SCIENCE↗

Quantitative Prediction of Perovskite Stability Using Accelerated Testing and Machine Learning

PV technologies based on hybrid perovskites offer the potential for reducing solar cell costs, but they are particularly vulnerable to degradation by environmental factors such as moisture, oxygen, and illumination. Commercialization will require not only stable materials and device architectures but also accelerated testing protocols and models that can predict degradation from the accelerated testing data. Here, we report results from in situ photoluminescence (PL) and photoconductivity (PC) measurements during perovskite degradation with simultaneous optical transmittance (Tr) measurements or reflected dark field (DF) imaging. From PL, PC, Tr, and DF, we determine (respectively) the steady-state quasi-Fermi level splitting, the mean effective carrier diffusion length, the extent of conversion of perovskite to higher bandgap degradation products, and the extent of scattering from domains with different orientation or composition, all as a function of time during degradation. Simultaneous measurement of PL-PC-Tr or PL-PC-DF on perovskite absorbers in an environmental chamber over a wide range of humidity, oxygen, temperature, and illumination levels yields a rich data set. We use machine learning to develop a model that accurately predicts (within 10%) the time for the diffusion length to decrease to 85% of its initial value. The model takes the environmental conditions and the first few measurements from the PL-PC-Tr or PL-PC-DF experiment as input. Thus, the model provides a framework to interpret the results of accelerated testing of absorber materials. One of the dominant features in the model of degradation for CH 3 NH 3 PbI 3 is the initial rate at which transmittance increase. For devices with opaque contacts, the pixel-averaged rate of change of the intensity in dark-field images can be used in place of transmittance. Results are also presented on full PV devices with in-situ current-voltage (JV) measurements. Here, the data from simultaneous PL-DF-JV under environmental stresses reveal intimate connection between degradation and shunts and provide a framework to extend accelerated testing to devices. Further, the presentation reveals underlying universal behavior in degradation pathways over a broad range of environmental stresses and perovskite compositions.

14 SOLAR ENERGY↗

Trap Passivation for Reducing On-Resistance and Saturation Voltage in Wafer-Bonded InGaAs-Channel/GaN-Drain Vertical FETs

High frequency and high power are the driving forces behind semiconductor transistor technology. However, conventional devices have the tradeoff of either being high speed or high breakdown—but not both. Wafer-bonded current aperture vertical electron transistors (BAVETs) help eliminate the tradeoff by combining a high-speed III-As channel to a high-breakdown III-N drift region. The device presented herein comprises of an InAlAs gate-barrier/InGaAs channel, wafer-bonded to an InGaN/GaN drift region, with the InGaAs/InGaN interface referred to as the wafer-bonded interface (WBI). The electronic behavior of WBIs is yet less known but necessary in realizing the potential of a BAVET. Herein, strong trap activity at the WBI is shown to be the cause of abnormally high saturation voltage ( V DS_SAT ) in BAVETs. The traps cause unintentional space charge (SC) region in the drain region of the device. This causes a drain resistance, a higher ON-resistance ( R ON ), and a higher V DS_SAT . Here, the challenge is overcome by hydrogen passivation of traps at WBI by using a p-doping for the InAlAs layer, which reduces the trap-charge concentration at the WBI. Consequently, the width of the SC region is reduced and a reduction in V DS_SAT is demonstrated, wherein it reduces from >12 to 5 V.

36 MATERIALS SCIENCE↗

Probing the Atomic Scale Mechanisms of Time Dependent Dielectric Breakdown in Si/SiO 2 MOSFETs (June 2022)

Here we report on an atomic-scale study of trap generation in the initial/intermediate stages of time-dependent dielectric breakdown (TDDB) in high-field stressed (100) Si/SiO2 MOSFETs using two powerful analytical techniques: electrically detected magnetic resonance (EDMR) and near-zero-field magnetoresistance (NZFMR). We find the dominant EDMR-sensitive traps generated throughout the majority of the TDDB process to be silicon dangling bonds at the (100) Si/SiO2 interface (Pb0 and Pb1 centers) for both the spin-dependent recombination (SDR) and trap-assisted tunneling (SDTAT) processes. We find this generation to be linked to both changes in the calculated interface state densities as well as changes in the NZFMR spectra for recombination events at the interface, indicating a redistribution of mobile magnetic nuclei which we conclude could only be due to the redistribution of hydrogen at the interface. Additionally, we observe the generation of traps known as E’ centers in EDMR measurements at lower experimental temperatures via SDR measurements at the interface. Our work strongly suggests the involvement of a rate-limiting step in the tunneling process between the silicon dangling bonds generated at the interface and the ones generated throughout the oxide.

36 MATERIALS SCIENCE↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗