Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Tracking and data acquisition system for the 1990's. Volume 7: TDAS space technology assessment

The results of the TDAS and user spacecraft technology assessment effort are provided. For each TDAS Satellite enhancement and user spacecraft element previously enumerated, the technology issues are identified and the R&D needed to resolve these issues is delineated. Subsequently, taking into account developments taking place elsewhere, the addition unique TDAS satellite module and user spacecraft element R&D efforts needed are identified, and conclusions are drawn in each case. From these conclusions, it is evident that with additional unique R&D efforts carried out for TDAS and appropriate user spacecraft elements the desired TDAS' capabilities for the 1990's can be realized and user spacecraft can be implemented that adequately interface with the projected TDAS.

Khatri, R.↗

Tracking and data acquisition system for the 1990's. Volume 8: TDAS frequency planning

Current planning calls for the TDAS to support new user and crosslink services, in addition to TDRSS-compatible services. TDRSS-compatible services would operate in current S-band and K-band channels used by TDRSS. New services, however, can take advantage of technology advances at microwave and optical frequencies. For augmented space-to-space services, 60 GHz and GaAs laser systems offer technical advantages, relative freedom from RFI, and a benign regulatory environment (i.e., minimal congestion and, in the case of 60 GHz, maximum regulatory support for TDAS-type services). For TDAS Earth-to-space and space-to-Earth services, the 30/20 GHz band offers the best mix of technical and regulatory advantages. But use of these bands would have to be coordinated with the U.S. military.

Heppe, S. B.↗

Category 5 problem solution using an unstructured finite volume algorithm

For the simulation of flows with complex geometries, unstructured finite volume methods have proven to be very popular, and simulations of a large number of flows have been done with good results using this approach. Since most of the simulations to date were done for steady flows, it is not clear that present unstructured finite volume algorithms can accurately track the unsteady propagation of acoustic waves in a computation. Therefore, there is a need to assess the accuracy of these methods for acoustic calculations. In this paper, we perform the numerical simulation of a very small amplitude acoustic wave incident on the non-uniform steady flow in a quasi- 1 D convergent-divergent nozzle using an unstructured finite volume algorithm with piece-wise linear, least square reconstruction, Roe flux difference splitting, and second-order MacCormack time marching. First, the spatial accuracy of the algorithm is evaluated for the steady flow by running the simulation with a sequence of successively finer meshes. Then the unsteady numerical solution with the acoustic perturbation is presented.

Bui, Trong T.↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Simulation of the Formation of DNA Double Strand Breaks and Chromosome Aberrations in Irradiated Cells

The formation of DNA double-strand breaks (DSBs) and chromosome aberrations is an important consequence of ionizing radiation. To simulate DNA double-strand breaks and the formation of chromosome aberrations, we have recently merged the codes RITRACKS (Relativistic Ion Tracks) and NASARTI (NASA Radiation Track Image). The program RITRACKS is a stochastic code developed to simulate detailed event-by-event radiation track structure: [1] This code is used to calculate the dose in voxels of 20 nm, in a volume containing simulated chromosomes, [2] The number of tracks in the volume is calculated for each simulation by sampling a Poisson distribution, with the distribution parameter obtained from the irradiation dose, ion type and energy. The program NASARTI generates the chromosomes present in a cell nucleus by random walks of 20 nm, corresponding to the size of the dose voxels, [3] The generated chromosomes are located within domains which may intertwine, and [4] Each segment of the random walks corresponds to approx. 2,000 DNA base pairs. NASARTI uses pre-calculated dose at each voxel to calculate the probability of DNA damage at each random walk segment. Using the location of double-strand breaks, possible rejoining between damaged segments is evaluated. This yields various types of chromosomes aberrations, including deletions, inversions, exchanges, etc. By performing the calculations using various types of radiations, it will be possible to obtain relative biological effectiveness (RBE) values for several types of chromosome aberrations.

Plante, Ianik↗

Test beam demonstration of silicon microstrip modules with transverse momentum discrimination for the future CMS tracking detector

A new CMS Tracker is under development for operation at the High Luminosity LHC from 2026 onwards. It includes an outer tracker based on dedicated modules that will reconstruct short track segments, called stubs, using spatially coincident clusters in two closely spaced silicon sensor layers. These modules allow the rejection of low transverse momentum track hits and reduce the data volume before transmission to the first level trigger. The inclusion of tracking information in the trigger decision is essential to limit the first level trigger accept rate. A customized front-end readout chip, the CMS Binary Chip (CBC), containing stub finding logic has been designed for this purpose. A prototype module, equipped with the CBC chip, has been constructed and operated for the first time in a 4 GeemVem/emc positron beam at DESY. The behaviour of the stub finding was studied for different angles of beam incidence on a module, which allows an estimate of the sensitivity to transverse momentum within the future CMS detector. A sharp transverse momentum threshold around 2 emVem/emc was demonstrated, which meets the requirement to reject a large fraction of low momentum tracks present in the LHC environment on-detector. This is the first realistic demonstration of a silicon tracking module that is able to select data, based on the particle's transverse momentum, for use in a first level trigger at the LHC . The results from this test are described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-J-01: A Formulation of 4D Treatment Planning for Tumour Tracking Volumetric Modulated Arc Therapy for Lung Cancer

Purpose: To develop a formulation for 4D treatment planning for a tumour tracking volumetric modulated arc therapy treatment (VMAT) plan for lung cancer. Methods: A VMAT plan was optimized based on a reference phase of the 4DCT of a lung cancer patient. The PTV was generated from the GTV of the reference phase. The collimator angle was set to 90 degrees such that the MLC travels along superior-inferior direction which is the main component of movement of a lung tumour. Then, each control point of the VMAT plan was assigned to a particular phase of the 4DCT in chronological order. The MLC positions of each control point were shifted according to the position of the tumour centroid of its assigned phase to form a tumour tracking VMAT plan. The control points of the same phase were grouped to form a pseudo VMAT plan for that particular phase. Dose calculation was performed for each pseudo VMAT plan on the corresponding phase of the 4DCT. The CTs of all phases were registered to the reference phase CT according to the displacement of the tumour centroid. The individual dose distributions of the pseudo VMAT plans were summed up and displayed on the reference phase of the 4DCT. A control VMAT plan was optimized based on a PTV generated from the ITV of all phases and compared with the tumour tracking VMAT plan. Results: Both plans achieved >95% volume coverage at the prescription dose level (96% for the tumour tracking plan and 97% for the control plan). But the normal lung volume irradiated at the prescription dose level was 39% less for the tumour tracking plan than the control plan. Conclusion: A formulation of 4D treatment planning for tumour tracking VMAT plans for lung cancer was developed.

60 APPLIED LIFE SCIENCES↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

Multiscale in-situ characterization of static recrystallization using dark-field X-ray microscopy and high-resolution X-ray diffraction

Abstract Dark-field X-ray microscopy (DFXM) is a high-resolution, X-ray-based diffraction microstructure imaging technique that uses an objective lens aligned with the diffracted beam to magnify a single Bragg reflection. DFXM can be used to spatially resolve local variations in elastic strain and orientation inside embedded crystals with high spatial (~ 60 nm) and angular (~ 0.001°) resolution. However, as with many high-resolution imaging techniques, there is a trade-off between resolution and field of view, and it is often desirable to enrich DFXM observations by combining it with a larger field-of-view technique. Here, we combine DFXM with high-resolution X-ray diffraction (HR-XRD) applied to an in-situ investigation of static recrystallization in an 80% hot-compressed Mg–3.2Zn–0.1Ca wt.% (ZX30) alloy. Using HR-XRD, we track the relative grain volume of > 8000 sub-surface grains during annealing in situ. Then, at several points during the annealing process, we “zoom in” to individual grains using DFXM. This combination of HR-XRD and DFXM enables multiscale characterization, used here to study why particular grains grow to consume a large volume fraction of the annealed microstructure. This technique pairing is particularly useful for small and/or highly deformed grains that are often difficult to resolve using more standard diffraction microstructure imaging techniques.

36 MATERIALS SCIENCE↗

SU-C-17A-07: The Development of An MR Accelerator-Enabled Planning-To-Delivery Technique for Stereotactic Palliative Radiotherapy Treatment of Spinal Metastases

Purpose: To develop an MR accelerator-enabled online planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases. The technical challenges include; automated stereotactic treatment planning, online MR-based dose calculation and MR guidance during treatment. Methods: Using the CT data of 20 patients previously treated at our institution, a class solution for automated treatment planning for spinal bone metastases was created. For accurate dose simulation right before treatment, we fused geometrically correct online MR data with pretreatment CT data of the target volume (TV). For target tracking during treatment, a dynamic T2-weighted TSE MR sequence was developed. An in house developed GPU based IMRT optimization and dose calculation algorithm was used for fast treatment planning and simulation. An automatically generated treatment plan developed with this treatment planning system was irradiated on a clinical 6 MV linear accelerator and evaluated using a Delta4 dosimeter. Results: The automated treatment planning method yielded clinically viable plans for all patients. The MR-CT fusion based dose calculation accuracy was within 2% as compared to calculations performed with original CT data. The dynamic T2-weighted TSE MR Sequence was able to provide an update of the anatomical location of the TV every 10 seconds. Dose calculation and optimization of the automatically generated treatment plans using only one GPU took on average 8 minutes. The Delta4 measurement of the irradiated plan agreed with the dose calculation with a 3%/3mm gamma pass rate of 86.4%. Conclusions: The development of an MR accelerator-enabled planning-todelivery technique for stereotactic palliative radiotherapy treatment of spinal metastases was presented. Future work will involve developing an intrafraction motion adaptation strategy, MR-only dose calculation, radiotherapy quality-assurance in a magnetic field, and streamlining the entire treatment process on an MR accelerator.

60 APPLIED LIFE SCIENCES↗

Truchas-Flow

The truchas flow algorithm is designed for simulating the behavior of incompressible (but not necessarily constant density) fluids on unstructured meshes while allowing for solid and void phases to serve as moving boundaries. The interface between fluids, solids and void is tracked via a geometric volume of fluid approach. This allows for a single fluid formulation of the governing equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Task 12 PV Sustainability - Status of PV Module Recycling in Selected IEA PVPS Task 12 Countries

Photovoltaic (PV) deployment has accelerated in recent years compared to projections in the early 2010s. This means that PV end of life (EOL) waste streams will also increase at a higher pace than anticipated. To meet and optimise PV EOL management, appropriate regulatory and technological approaches must be implemented in the near term, ensuring that available options are adapted to the conditions of each country or region. This report aims to review the current regulatory and industrial landscape for selected countries belonging to the International Energy Agency's PV Power Systems technology collaboration programme, to assess status of PV EOL management, allow for comparison and cross-fertilization, and establish a foundation for future tracking of progress. Although volumes of EOL PV modules are still small, EOL PV is treated and recycled in a proper manner in the countries and regions that have EOL regulations in place. However, the current low volumes, limited available recycling technologies, logistics challenges, and undeveloped markets for recovered materials result in a high-cost, low-revenue scenario for PV module recycling globally. Nevertheless, the implementation of PV EOL regulations in more countries and R&D investment in PV recycling is expected to accelerate further improvements to meet future demand and to achieve high-value, low-cost recycling. We hope this report contributes to understanding the global status of PV recycling and to accelerating its development as a promising option for the proper EOL management of PV modules in the coming decades.

14 SOLAR ENERGY↗

Hazard Detection Detector Cards

This report presents a comprehensive summary of five advanced anomaly detection tools developed and deployed by Oak Ridge National Laboratory in support of the VA’s Health Information Technology modernization. These detectors—Order Path Tracker, Trend Watcher, Pain Pointer, Performance Monitor, and Patient Record Flag Detector—leverage statistical and machine learning methods to monitor workflow disruptions, detect anomalies in care sequences and volumes, identify bottlenecks, and track system-level performance metrics across VistA and Millennium systems. All detectors have been integrated into the Health Data Analytics Platform (HDAP), with most having completed deployment and testing using live data from targeted stations in cardiology and oncology domains. This work enhances VA’s capacity for proactive system surveillance, promotes patient safety, and informs data-driven operational improvements across the EHR ecosystem.

97 MATHEMATICS AND COMPUTING↗

Tracking and Data Relay Satellite System configuration and tradeoff study. Volume 2: Delta 2914 launched TDRSS, Configuration 2. Part 2: Final Report, 22 August 1972 - 1 April 1973

Configuration data and design information for a Delta 2914 launched configuration with greatly enhanced telecommunication service over the Part I Delta 2914 configuration is contained. The overall system definition, operations and control, and telecommunication service system, including link budgets are discussed. A brief description of the user transceiver and ground station is presented. A final section includes a summary description of the TDR spacecraft and all the subsystems. The data presented are largely in tabular form.

Source record↗

Tracking and Data Relay Satellite System configuration and tradeoff study. Volume 3: Atlas Centaur launched TDRSS. Part 2: Final Report, 22 August 1972 - 1 April 1973

Configuration data and design information for the Atlas Centaur launched configuration are presented. Overall system definition, operations and control, and telecommunication service system, including link budgets, are discussed. A brief description of the user telecommunications equipment and ground station is presented. A summary description of the TDR spacecraft and all the subsystems is included. The data presented are largely in tabular form. A brief treatment of an optional configuration with enhanced telecommunications service is described.

Source record↗

Tracking and Data Relay Satellite System configuration and tradeoff study. Volume 4: Space shuttle launched TDRSS. Part 2: Final Report, 22 August 1972 - 1 April 1973

Configuration data and design information for the space shuttle launched configuration is presented. The overall system definition, operations and control, and telecommunication service system including link budgets are discussed. A brief description of the user transceiver and ground station is presented. A final section includes a summary description of the TDR spacecraft and all the subsystems. The data presented are largely in tabular form.

Source record↗