Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Association Between Pulmonary Uptake of Fluorodeoxyglucose Detected by Positron Emission Tomography Scanning After Radiation Therapy for Non-Small-Cell Lung Cancer and Radiation Pneumonitis

Purpose: To study the relationship between fluorodeoxyglucose (FDG) uptake in pulmonary tissue after radical radiation therapy (RT) and the presence and severity of radiation pneumonitis. Methods and Materials: In 88 consecutive patients, {sup 18}F-FDG-positron emission tomography was performed at a median of 70 days after completion of RT. Patients received 60 Gy in 30 fractions, and all but 15 had concurrent platinum-based chemotherapy. RT-induced pulmonary inflammatory changes occurring within the radiation treatment volume were scored, using a visual (0 to 3) radiotoxicity grading scale, by an observer blinded to the presence or absence of clinical radiation pneumonitis. Radiation pneumonitis was retrospectively graded using the Radiation Therapy Oncology Group (RTOG) scale by an observer blinded to the PET radiotoxicity score. Results: There was a significant association between the worst RTOG pneumonitis grade occurring at any time after RT and the positron emission tomograph (PET) radiotoxicity grade (one-sided p = 0.033). The worst RTOG pneumonitis grade occurring after the PET scan was also associated with the PET radiotoxicity grade (one-sided p = 0.035). For every one-level increase in the PET toxicity scale, the risk of a higher RTOG radiation pneumonitis score increased by approximately 40%. The PET radiotoxicity score showed no significant correlation with the duration of radiation pneumonitis. Conclusions: The intensity of FDG uptake in pulmonary tissue after RT determined using a simple visual scoring system showed significant correlation with the presence and severity of radiation pneumonitis. {sup 18}F-FDG-PET may be useful in the prediction, diagnosis and therapeutic monitoring of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atypical Behavior Identification in Large Scale Network Traffic

Cyber analysts are faced with the daunting challenge of identifying exploits and threats within potentially billions of daily records of network traffic. Enterprise-wide cyber traffic involves hundreds of millions of distinct IP addresses and results in data sets ranging from terabytes to petabytes of raw data. Creating behavioral models and identifying trends based on those models requires data intensive architectures and techniques that can scale as data volume increases. Analysts need scalable visualization methods that foster interactive exploration of data and enable identification of behavioral anomalies. Developers must carefully consider application design, storage, processing, and display to provide usability and interactivity with large-scale data. We present an application that highlights atypical behavior in enterprise network flow records. This is accomplished by utilizing data intensive architectures to store the data, aggregation techniques to optimize data access, statistical techniques to characterize behavior, and a visual analytic environment to render the behavioral trends, highlight atypical activity, and allow for exploration.

99 GENERAL AND MISCELLANEOUS↗

Expanding Access to Science Participation: A FAIR Framework for Petascale Data Visualization and Analytics

The massive data generated by scientists daily serve as both a major catalyst for new discoveries and innovations, as well as a significant roadblock that restricts access to the data. Here, our paper introduces a new approach to removing Big Data barriers and democratizing access to petascale data for the broader scientific community. Our novel data fabric abstraction layer allows user-friendly querying of scientific information while hiding the complexities of dealing with file systems or cloud services. We enable FAIR (Findable, Accessible, Interoperable, and Reusable) access to datasets such as NASA’s petascale climate datasets. Our paper presents an approach to managing, visualizing, and analyzing petabytes of data within a browser on equipment ranging from the top NASA supercomputer to commodity hardware like a laptop. Our novel data fabric abstraction utilizes state-of-the art progressive compression algorithms and machine-learning insights to power scalable visualization dashboards for petascale data. The result provides users with the ability to identify extreme events or trends dynamically, expanding access to scientific data and further enabling discoveries. We validate our approach by improving the ability of climate scientists to visually explore their data via three fully interactive dashboards. We further validate our approach by deploying the dashboards and simplified training materials in the classroom at a minority-serving institution. These dashboards, released in simplified form to the general public, contribute significantly to a broader push to democratize the access and use of climate data.

Computer science↗

SU-E-J-24: An Evaluation of the Stability of Image Quality Parameters of Varian On-Board Imaging (OBI) and EPID Imaging Systems

Purpose: Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and the radiographic MV EPID mode. Methods: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For OBI CBCT, High quality head Full-Fan acquisition and Pelvis Half-Fan acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution, HU constancy and geometric distortion. Dose and kVp for the OBI were recorded using the Unfors RaySafe Xi system with the R/F High Detector for planar kV and the CT detector for CBCT. Dose for the MV EPID was recorded using a PTW975 Semiflex Ion Chamber, PTW Unidos electrometer and SolidWater™. Results: For each metric, values were normalized to the mean and the standard deviations were recorded. For the planar radiographic spatial resolution the f30, f40, f50 were 0.015, 0.008, 0.004 and 0.006, 0.009, 0.018 for the kV and MV, respectively. The standard deviation of the dose for kV was 0.010 and 0.005 for the MV. The standard deviations for Full and half fan were averaged together and the following standard deviations for each metric were recorded: 0.075(uniformity), 0.071(noise), 0.006(AP-Geometric Distortion), 0.005(LAT-Geometric Distortion), 0.058(mean slice thickness), 0.098(f30),0.101(f40),0.124(f50), 0.031(Lung/PMP-HU constancy), 0.063(Water/poly-HU constancy), 0.015(Bone/Derlin-HU constancy),0.006(Dose-Center), 0.004(Dose-Periphery). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion: A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Varian OBI and EPID Imaging systems. The two systems show consistent imaging and dosimetric properties over the evaluated time frame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-50: An Evaluation of the Stability of Image Quality Parameters of the Elekta XVI and IView Imaging Systems

Introduction Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and MV mode. Methods and Materials: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For XVI CBCT, Head and Neck Small20 (S20) and Pelvis Medium20 (M20) standard acquisition modes were evaluated for Uniformity, Noise, Spatial Resolution and HU constancy. Dose and kVp for the XVI were recorded using the Unfors RaySafe Xi system with the R/F Low Detector for the kV planar radiographic mode. Results A total of 20 and 10 measurements were acquired for the planar radiographic and CBCT systems respectively over a two month period. Values were normalized to the mean and the standard deviations (STD) were recorded. For the planar radiographic spatial resolution, the STD for f30, f40, f50 were 0.004, 0.002, 0.002 and 0.005, 0.007, 0.008 for the kV and MV, respectively. The average recorded dose for kV was 38.7±2.7 μGy. The STD of the evaluated metrics for the S20 acquisition were: 0.444(f30), 0.067(f40), 0.062(f50), 0.018(Water/poly-HU constancy), 0.028(uniformity) and 0.106(noise). The standard deviations for the M20 acquisition were: 0.108(f30), 0.073(f40), 0.091(f50), 0.008(Water/poly-HU constancy), 0.005(uniformity) and 0.005(noise). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Elekta XVI and iView imaging systems. Consistent imaging and dosimetric properties over the evaluated time frame were noted. This work was funded in part by the Cancer Prevention Research Institute of Texas Pre doctoral fellowship training grant (RP140105) to Dennis N. Stanley M.Sc.

60 APPLIED LIFE SCIENCES↗

An annotation system for 3D fluid flow visualization

Annotation is a key activity of data analysis. However, current systems for data analysis focus almost exclusively on visualization. We propose a system which integrates annotations into a visualization system. Annotations are embedded in 3D data space, using the Post-it metaphor. This embedding allows contextual-based information storage and retrieval, and facilitates information sharing in collaborative environments. We provide a traditional database filter and a Magic Lens filter to create specialized views of the data. The system has been customized for fluid flow applications, with features which allow users to store parameters of visualization tools and sketch 3D volumes.

Loughlin, Maria M.↗

Volumetric imaging of supersonic boundary layers using filtered Rayleigh scattering background suppression

We demonstrate the use of Filtererd Rayleigh Scattering and a 3D reconstruction technique to interrogate the highly three dimensional flow field inside of a supersonic inlet model. A 3 inch by 3 inch by 2.5 inch volume is reconstructed yielding 3D visualizations of the crossing shock waves and of the boundary layer. In this paper we discuss the details of the techniques used, and present the reconstructured 3D images.

Forkey, Joseph N.↗

Visualization Techniques in Space and Atmospheric Sciences

Unprecedented volumes of data will be generated by research programs that investigate the Earth as a system and the origin of the universe, which will in turn require analysis and interpretation that will lead to meaningful scientific insight. Providing a widely distributed research community with the ability to access, manipulate, analyze, and visualize these complex, multidimensional data sets depends on a wide range of computer science and technology topics. Data storage and compression, data base management, computational methods and algorithms, artificial intelligence, telecommunications, and high-resolution display are just a few of the topics addressed. A unifying theme throughout the papers with regards to advanced data handling and visualization is the need for interactivity, speed, user-friendliness, and extensibility.

Szuszczewicz, E. P.↗

Visualizing Time-Varying Phenomena In Numerical Simulations Of Unsteady Flows

Streamlines, contour lines, vector plots, and volume slices (cutting planes) are commonly used for flow visualization. These techniques are sometimes referred to as instantaneous flow visualization techniques because calculations are based on an instant of the flowfield in time. Although instantaneous flow visualization techniques are effective for depicting phenomena in steady flows,they sometimes do not adequately depict time-varying phenomena in unsteady flows. Streaklines and timelines are effective visualization techniques for depicting vortex shedding, vortex breakdown, and shock waves in unsteady flows. These techniques are examples of time-dependent flow visualization techniques, which are based on many instants of the flowfields in time. This paper describes the algorithms for computing streaklines and timelines. Using numerically simulated unsteady flows, streaklines and timelines are compared with streamlines, contour lines, and vector plots. It is shown that streaklines and timelines reveal vortex shedding and vortex breakdown more clearly than instantaneous flow visualization techniques.

Lane, David A.↗

Interactive Correlation Analysis and Visualization of Climate Data

The relationship between our ability to analyze and extract insights from visualization of climate model output and the capability of the available resources to make those visualizations has reached a crisis point. The large volume of data currently produced by climate models is overwhelming the current, decades-old visualization workflow. The traditional methods for visualizing climate output also have not kept pace with changes in the types of grids used, the number of variables involved, and the number of different simulations performed with a climate model or the feature-richness of high-resolution simulations. This project has developed new and faster methods for visualization in order to get the most knowledge out of the new generation of high-resolution climate models. While traditional climate images will continue to be useful, there is need for new approaches to visualization and analysis of climate data if we are to gain all the insights available in ultra-large data sets produced by high-resolution model output and ensemble integrations of climate models such as those produced for the Coupled Model Intercomparison Project. Towards that end, we have developed new visualization techniques for performing correlation analysis. We have also introduced highly scalable, parallel rendering methods for visualizing large-scale 3D data. This project was done jointly with climate scientists and visualization researchers at Argonne National Laboratory and NCAR.

54 ENVIRONMENTAL SCIENCES↗

Refracting Roentgen's rays: Propagation-based x-ray phase contrast for biomedical imaging

Absorption-contrast x-ray imaging serves to visualize the variation in x-ray attenuation within the volume of a given sample, whereas phase contrast allows one to visualize variations in x-ray refractive index. The former imaging mechanism has been well known and widely utilized since the time of Roentgen's Nobel prize winning work, whereas the latter mechanism--sought for, but not found, by Roentgen himself--has laid the foundation for a revolution in x-ray imaging which is the central topic of this review. We consider the physical imaging mechanisms underlying both absorption contrast and phase contrast, together with the associated inverse problem of how one may obtain quantitative two- or three-dimensional information regarding a sample, given one or more phase-contrast images of the same. Practical questions are considered, regarding optimized phase-contrast imaging geometries as a function of detector resolution, source size, x-ray spectrum, and dose. Experimental examples pertaining to biomedical applications are given, and prospects for the future outlined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Illustrating Surface Shape in Volume Data via Principal Direction-Driven 3D Line Integral Convolution

The three-dimensional shape and relative depth of a smoothly curving layered transparent surface may be communicated particularly effectively when the surface is artistically enhanced with sparsely distributed opaque detail. This paper describes how the set of principal directions and principal curvatures specified by local geometric operators can be understood to define a natural 'flow' over the surface of an object, and can be used to guide the placement of the lines of a stroke texture that seeks to represent 3D shape information in a perceptually intuitive way. The driving application for this work is the visualization of layered isovalue surfaces in volume data, where the particular identity of an individual surface is not generally known a priori and observers will typically wish to view a variety of different level surfaces from the same distribution, superimposed over underlying opaque structures. By advecting an evenly distributed set of tiny opaque particles, and the empty space between them, via 3D line integral convolution through the vector field defined by the principal directions and principal curvatures of the level surfaces passing through each gridpoint of a 3D volume, it is possible to generate a single scan-converted solid stroke texture that may intuitively represent the essential shape information of any level surface in the volume. To generate longer strokes over more highly curved areas, where the directional information is both most stable and most relevant, and to simultaneously downplay the visual impact of directional information in the flatter regions, one may dynamically redefine the length of the filter kernel according to the magnitude of the maximum principal curvature of the level surface at the point around which it is applied.

Interrante, Victoria↗

Distributed Neural Representation for Reactive In Situ Visualization

Implicit neural representations (INRs) have emerged as a powerful tool for compressing large-scale volume data. This opens up new possibilities for in situ visualization. However, the efficient application of INRs to distributed data remains an underexplored area. Here, in this work, we develop a distributed volumetric neural representation and optimize it for in situ visualization. Our technique eliminates data exchanges between processes, achieving state-of-the-art compression speed, quality and ratios. Our technique also enables the implementation of an efficient strategy for caching large-scale simulation data in high temporal frequencies, further facilitating the use of reactive in situ visualization in a wider range of scientific problems. We integrate this system with the Ascent infrastructure and evaluate its performance and usability using real-world simulations.

Wu, Qi↗

MRI- Versus CT-Based Volume Delineation of Lumpectomy Cavity in Supine Position in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine magnetic resonance imaging (MRI) and computed tomography (CT) for lumpectomy cavity (LC) volume delineation in supine radiotherapy treatment position and to assess the interobserver variability. Methods and Materials: A total of 15 breast cancer patients underwent a planning CT and directly afterward MRI in supine radiotherapy treatment position. Then, 4 observers (2 radiation oncologists and 2 radiologists) delineated the LC on the CT and MRI scans and assessed the cavity visualization score (CVS). The CVS, LC volume, conformity index (CI), mean shift of the center of mass (COM), with the standard deviation, were quantified for both CT and MRI. Results: The CVS showed that MRI and CT provide about equal optimal visibility of the LC. If the CVS was high, magnetic resonance imaging provided more detail of the interfaces of the LC seroma with the unaffected GBT. MRI also pictured in more detail the interfaces of axillary seromas (if present) with their surroundings and their relationship to the LC. Three observers delineated smaller, and one observer larger, LC volumes comparing the MRI- and CT-derived delineations. The mean {+-} standard deviation CI was 32% {+-} 25% for MRI and 52% {+-} 21% for CT. The mean {+-} standard deviation COM shift was 11 {+-} 10 mm (range 1-36) for MRI and 4 {+-} 3 mm (range 1-10) for CT. Conclusions: MRI does not add additional information to CT in cases in which the CVS is assessed as low. The conformity (CI) is lower for MRI than for CT, especially at a low CVS owing to greater COM shifts for MRI, probably caused by inadequate visibility of the surgical clips on magnetic resonance (MR) images. The COM shifts seriously dictate a decline in the CI more than the variability of the LC volumes does. In cases in which MRI provides additional information, MRI must be combined with the CT/surgical clip data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction techniques for depth errors with stereo three-dimensional graphic displays

Three-dimensional (3-D), 'real-world' pictorial displays that incorporate 'true' depth cues via stereopsis techniques have proved effective for displaying complex information in a natural way to enhance situational awareness and to improve pilot/vehicle performance. In such displays, the display designer must map the depths in the real world to the depths available with the stereo display system. However, empirical data have shown that the human subject does not perceive the information at exactly the depth at which it is mathematically placed. Head movements can also seriously distort the depth information that is embedded in stereo 3-D displays because the transformations used in mapping the visual scene to the depth-viewing volume (DVV) depend intrinsically on the viewer location. The goal of this research was to provide two correction techniques; the first technique corrects the original visual scene to the DVV mapping based on human perception errors, and the second (which is based on head-positioning sensor input data) corrects for errors induced by head movements. Empirical data are presented to validate both correction techniques. A combination of the two correction techniques effectively eliminates the distortions of depth information embedded in stereo 3-D displays.

Parrish, Russell V.↗

Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Virtual Reality and Oceanography: Overview, Applications, and Perspective

With the ongoing, exponential increase in ocean data from autonomous platforms, satellites, models, and in particular, the growing field of quantitative imaging, there arises a need for scalable and cost-efficient visualization tools to interpret these large volumes of data. With the recent proliferation of consumer grade head-mounted displays, the emerging field of virtual reality (VR) has demonstrated its benefit in numerous disciplines, ranging frommedicine to archeology. However, these benefits have not received asmuch attention in the ocean sciences. Here, we summarize some of the ways that virtual reality has been applied to this field. We highlight a few examples in which we (the authors) demonstrate the utility of VR as a tool for ocean scientists. For oceanic datasets that are well-suited for three-dimensional visualization, virtual reality has the potential to enhance the practice of ocean science.

Noah L Walcutt↗