Search NASA⌕ Search

SEARCH · Search NASA

Results for “water consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life cycle analysis of polylactic acids from different wet waste feedstocks

Producing a valuable chemical product through diversion of wet wastes can simultaneously resolve the problems associated with increasing wastes and greenhouse gas emissions from conventional chemical production processes. In this work, we investigated the life-cycle greenhouse gas emissions, water, and fossil-fuel consumption for waste-derived polylactic acids (PLA) from three different waste feedstocks, namely wastewater sludge, food waste, and swine manure, using the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model. The decarbonization potential of replacing fossil-based resins with the waste-derived polymer was also investigated. The results show that swine manure-to-PLA pathway was the least carbon intensive (—1.4 kgCO 2 e/kg) among the three waste-to-PLA pathways on a cradle-to-grave basis, followed by the food waste case (—1.3 kgCO 2 e/kg) and then by the wastewater sludge case (0.6 kgCO 2 e/kg). In the baseline scenario, all three waste-to-PLA pathways were less carbon intensive than both fossil-based PET and HDPE on a cradle-to-grave basis: 66% (vs. PET) and 56% (vs. HDPE), 171 and 192%, 181 and 205% reduction in GHG emissions for wastewater sludge-, food waste-, and swine manure-to-PLA pathway, respectively. For all sensitivity cases investigated, the food waste- and swine manure-to-PLA pathways were significantly less carbon intensive than their fossil-counterparts. In terms of the annual decarbonization potential of replacing fossil-based PET or HDPE, the wastewater sludge- and food waste-pathway showed higher mitigation potential than the swine manure-pathway: i) 18–28 kilotons CO 2 e-reduction per year for wastewater sludge pathway; ii) 23–26 kTCO 2 e-reduction/yr for food waste pathway; and iii) about 5 kTCO 2 e-reduction/yr for swine manure pathway depending on the type of conventional resin replaced. However, given the abundant availability of the swine manure feedstocks across the United States, the decarbonization potential of swine manure-based pathway can also increase as the plant capacity or the number of plants grow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Treatment of brackish water for fossil power plant cooling

In this study, we evaluated the technical, economic and environmental impacts of retrofitting brackish groundwater treatment systems at existing coal- and gas-fired electric generating units (EGUs) to reduce freshwater consumption in wet cooling towers. Based on fleet averages, retrofitting brackish water treatment systems decreases unit freshwater consumption by 94–100%, while increasing the cost of electricity generation by 8–10%. The unit capacity shortfalls are less than 1.1%. The resulting cost of freshwater consumption savings by brackish water treatment is US$1.7 m -3 and US$2.9 m -3 on average for coal- and gas-fired EGUs, respectively. However, these trade-offs are highly affected by the brine disposal method. The use of thermal zero liquid discharge for brine disposal can roughly double the average cost of freshwater consumption savings. The cost-effectiveness of brackish water treatment compared with dry cooling deployment depends on how concentrated brines are managed. In conclusion, the identified trade-offs and their dependence fill knowledge gaps to better inform water management.

20 FOSSIL-FUELED POWER PLANTS↗

Spray Manufacturing Thermal Insulation Composites

Cellulose-based thermal insulation materials present significant potential for modern green building applications due to their inherent carbon sequestration properties. However, traditional manufacturing of composites often results in the limited thermal insulation performance and embodied carbon footprint due to an increased density from material shrinkage and higher energy consumption during the water-based slurry drying process. Here, we report solvent spraying coupled with dry powder feedstock to manufacture highly porous silica/straw insulation composites. The manufactured composite exhibits negligible shrinkage with the density of 0.08 g/cm 3 , thermal conductivity of 27.8 mW/(m·K), flexural modulus of 3.1 MPa, and compressive modulus of 0.89 MPa. Additionally, the prepared composite demonstrates fire retardancy (burning rate of 0.5 mm/min) and recyclability (99%). Furthermore, this solvent-spraying strategy opens up opportunities of energy-efficient insulation materials for carbon-sequestration building sectors.

36 MATERIALS SCIENCE↗

A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

47 OTHER INSTRUMENTATION↗

Energy-Efficient Forward Osmosis for FGD Wastewater Volume Minimization

A variant of forward osmosis, the Aquapod© process, was shown to be capable of concentrating FGDWW five-fold without the need for softening. The thermal and electrical energy consumption per unit of water produced was estimated to be 190 kJ/kg and ~2.2 kWh/m3, respectively. The FO process, in conjunction with a spray dryer, can achieve ZLD of 100 gpm of FGDWW with an estimated capital costs of $6.25 Million and a variable cost of $4.35/m3 of wastewater treated.

01 COAL, LIGNITE, AND PEAT↗

The Modeling of the Synfuel Production Process: Process models of Fischer-Tropsch production with electricity and hydrogen provided by various scales of nuclear plants

Synthetic fuels (synfuels), also known as electro-fuels (E-fuels), are hydrocarbon fuels produced from waste CO2 streams and water electrolysis, with electricity as the primary source of energy. To achieve substantial reductions in greenhouse gas (GHG) emissions, electricity sources must release zero carbon or near-zero carbon, as is the case with solar, wind, hydro, and nuclear power. Nuclear power is one of the largest and steadiest domestic sources of clean energy in the United States. Moreover, nuclear power has the potential to produce hydrogen economically for less than $2/kg, reaching the DOE near-term target price. Thus, using nuclear power to produce synfuels has the unique potential to significantly reduce the GHG emissions of hydrocarbon fuels production and end-use applications. Fisher-Tropsch or FT fuel (a mixture of naphtha, jet fuel, and diesel) is of great interest because it is a drop-in fuel that can be blended with conventional petroleum counterparts and is compatible with existing infrastructure. By using the ASPEN Plus model, this report develops FT fuel production models on three scales, corresponding to nuclear plants with capacities of 1000 MWe, 437 Mwe, and 100 MWe, respectively. The FT model case with energy from a 437-MWe nuclear plant is used as a baseline case. This report summarizes the baseline ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 507 MT/day (185,000 gal/day) of FT fuel by converting 255 MT/day of hydrogen and 1,580 MT/day of CO2. The FT fuel production energy efficiency from hydrogen and electricity energy inputs is 70% (lowerheating-value or LHV-based). Including the high-temperature electrolyzer in the system boundary, the FT fuel production LHV efficiency from electricity and thermal energy inputs is 51%, considering 39.8 kWh/kg of electricity and 6.86 kWh/kg of thermal energy use from a nuclear plant for hydrogen production. The FT production efficiency can potentially be increased by further integrating the heat exchange between nuclear plant and FT process, and this study is underway. The carbon conversion ratio in the baseline case is 99%, with process CO2 capture and recirculation and oxy-combustion using the oxygen by-product from water electrolysis. The hydrogen consumption is 1.38 kg/gal-FT fuel and the CO2 consumption is 8.56 kg/gal-FT fuel in the baseline case. With different FT production scales determined by the nuclear plant capacity, the FT model was scaled using the same operating parameters, which led to the same conversion efficiency regardless of scale. However, the different FT plant scales will impact the economics of FT fuel production; this impact will be examined in the next phase of this study.

Zang, Guiyan↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Double Deep Q-Networks for Optimizing Electricity Cost of a Water Heater

Electric water heaters represent 14% of the electricity consumption in the residential buildings and the cost associated with domestic water heating account for a good portion of the household expenses in the United States. In this context, intelligent control of water heaters gained a lot of research attention. In recent years, a significant number of intelligent water heater controllers, with various methods and intended uses, have been proposed. However, existing studies are mostly model-based approaches that require an accurate modelling of the water heater. Towards addressing this research gap, this paper presents a model-free reinforcement learning-based controller for a day-ahead price market. The controller aims to minimize the cost of domestic water heating while maintaining the user comfort. The results showed that the developed controller can help save energy cost while maintaining the temperatures within the desired comfort band.

Amasyali, Kadir↗

An innovative approach for atrazine electrochemical oxidation modelling: Process parameter effect, intermediate formation and kinetic constant assessment

Water reuse for irrigation activities is becoming a crucial worldwide challenge due to the depletion of water sources. Anyway, agricultural drainage can potentially contain dangerous contaminants such as metals, pesticides, and herbicides, including atrazine. To address the need for agriculture wastewater purification, we investigated atrazine removal from simulated wastewater by electro-oxidation using platinum-coated titanium electrodes on a lab-scale experimental apparatus. The effects of electrolyte composition and concentration, i.e. ionic strength and applied current density on atrazine removal, were investigated. The results demonstrated that the electrochemical oxidation of the herbicide occurred through two routes, depending on the presence or absence of oxidizing chlorine species. The generation of intermediates during the treatment was monitored and quantified by evaluating the effect of an inert electrolyte (NaClO 4 ) versus an oxidizable chlorine species (NaCl). In both experimental conditions, five intermediates were identified, including desethyl-atrazine (DEA), hydroxyatrazine (ATZ-OH), desisopropyl-atrazine (DIA) and desethyl-desisopropyl-atrazine (DEDIA). A degradation mechanism and a model for describing hydroxyl radicals and active chlorine species contributions at ATZ oxidation were also proposed. Intermediate evolution profiles suggest that ATZ degradation can be considered as a series–parallel reaction system. Finally, the energy requirement assessment for ATZ removal was carried out. The highest ATZ removal (≅98%) was achieved with NaCl = 0.08 M, J = 60 A/m −2 , and E C = 5.83 kWh m −3 . Results highlight that atrazine removal was improved when an active chlorine species (NaCl) was present in the water solution. Moreover, the addition of chlorine species during electro-oxidation is an energy-saving strategy. Collectively, electro-oxidation technique can be efficiently applied to treat polluted water in order to meet the needs of recycling water quality and reduce resource consumption.

Electro-chemical oxidation↗

Historical and Future Global Irrigation Energy Consumption by Fuel and Region

Irrigation energy use is a significant component of agricultural production costs, contributing directly to the energy and emissions intensity of crop production and ultimately to food prices. Understanding the existing structure of irrigation energy consumption help achieve food-energy-water security and environmental goals. We present a comprehensive global data set detailing country-level irrigation energy consumption, emphasizing the comparative use of electric, diesel, and emerging solar pumps. To our knowledge, no such data set exists. We draw from a literature review to develop a logistic transformed regression model to estimate the shares of fuel sources for irrigation across countries over historical years to construct a global data set of country-level irrigation energy consumption by multiple fuel sources. Additionally, we compare our estimates of irrigation energy use with agricultural energy use as reported by the International Energy Agency and other external sources. We then use this data to project future irrigation energy use with the Global Change Analysis Model, which is a multisector dynamics model, to showcase the usage of this data set. Projections under the reference scenario show a global shift in fuel types for irrigation pumping, while patterns vary across regions, with India and Pakistan leading in solar-powered irrigation growth and countries like the USA and China continuing to rely primarily on grid electricity. This data set provides a resource to understand the role of irrigation fuel choices within the broader energy sector, as well as the connected agricultural, land use, and water sectors under alternative future scenarios, enabling informed decision making toward efficient agricultural practices.

Global Change Analysis Model (GCAM)↗

Inorganic Alterations in Unconventional Shale Reservoirs: Importance of Additive and Base Fluid Chemistry

The effective development of unconventional petroleum systems requires the use of significant water resources. In an effort to reduce the consumption of freshwater resources for hydraulic fracturing, highly saline produced waters are increasingly recycled for use as a base fluid. However, there are significant knowledge gaps regarding potential water–rock interactions resulting from the introduction of produced waters and associated additives into shale reservoirs such as formation and deposition of mineral scale, which can negatively affect hydrocarbon production through wellbore restriction and damage to hydraulically generated fractures. To assess the impacts of field stimulation practices in the subsurface, a series of laboratory experiments were completed using (a) three distinct sedimentary rock formations of the Midland Basin (Texas, USA) and (b) additives with two different base fluids: municipal fresh water and clean brine. The experimental approach used relevant injection sequences and mixing ratios in specialized reactors for 3 weeks. Static pressurized experiments and nonpressurized time-resolved experiments were undertaken. The resulting solids and liquids were analyzed by using a variety of laboratory- and synchrotron-based techniques. The use of an acid spearhead (15% HCl) resulted in texturing of both clay-rich and calcareous shales, which can temporarily enhance porosity but subsequently result in mineral scale deposition. The primary matrix scale was Fe(III)-bearing phases, which occurred in all experiments regardless of base fluid chemistry. Additionally, strontium sulfate (SrSO 4 ) precipitated on shale surfaces when clean brines were used. It was concluded that clean brine was the main source of Sr 2+ species, while persulfate breaker degradation and oxidation of pyrite were the sources of SO 4 2– . Sulfate scaling was more pronounced in clay-rich shales, suggesting that Sr sorption is important for promoting celestite formation. This work demonstrates that mineral scale deposition is a complex phenomenon, whereby the type and proportions of various mineral phases are determined from reservoir alteration processes and coprecipitation of constituents from injection fluids. In conclusion, the experimental results shown here should be considered when evaluating different base fluids and additives in order to mitigate mineral precipitation in unconventional shale reservoirs, which could result in reservoir degradation.

Jew, Adam D. [SLAC National Accelerator Laboratory↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Protocols for Assessing Transformation Rates of Nitrous Oxide in the Water Column

Nitrous oxide (N 2 O) is a potent greenhouse gas and an ozone destroying substance. Yet, clear step-by-step protocols to measure N 2 O transformation rates in freshwater and marine environments are still lacking, challenging inter-comparability efforts. Here we present detailed protocols currently used by leading experts in the field to measure water-column N 2 O production and consumption rates in both marine and other aquatic environments. We present example 15 N-tracer incubation experiments in marine environments as well as templates to calculate both N 2 O production and consumption rates. We discuss important considerations and recommendations regarding (1) precautions to prevent oxygen (O 2 ) contamination during low-oxygen and anoxic incubations, (2) preferred bottles and stoppers, (3) procedures for 15 N-tracer addition, and (4) the choice of a fixative. We finally discuss data reporting and archiving. We expect these protocols will make 15 N-labeled N 2 O transformation rate measurements more accessible to the wider community and facilitate future inter-comparison between different laboratories.

15N-tracer incubations↗

Workforce Development Opportunities Through the US Department of Energy’s Better Plants Program 2025

The increasing global demand for energy underscores the importance of energy efficiency and sustainability. To address these challenges in the US manufacturing sector, the US Department of Energy has implemented the Better Plants and Better Climate Challenge programs. These initiatives aim to reduce energy consumption, greenhouse gas emissions, and water usage in industrial facilities. This paper highlights a critical component of these programs, workforce development, which equips individuals with the skills and knowledge to implement energy-saving measures. Through the variety of training opportunities discussed, including bootcamps, in-plant trainings, virtual trainings, and annual events, the programs are able to cater to a wide range of industrial participants, from entry-level professionals to experienced engineers. By fostering collaboration and knowledge sharing and by leveraging certifications offered by organizations like the Association of Energy Engineers, these initiatives empower individuals to drive innovation and sustainable practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗