Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Green's function fast multipole method for continuum mechanics (SM-FMM)

Solid Mechanics Fast Multipole Method based on elastic Green's function and accelerated using FFTs The code calculates the mechanical fields (stress and strain) for a heterogeneous elasto-plastic material unit cell under quasi-static conditions (no dynamic effects). The fields are calculated using a Green's function method, where the strain field is given by a discrete convolution of Green's operator with an auxiliary stress field. The convolution is calculated using the fast multipole method.

Zecevic, Miroslav↗

Neutron interrogation systems using pyroelectric crystals and methods of preparation thereof

According to one embodiment, an apparatus includes a pyroelectric crystal, a deuterated or tritiated target, an ion source, and a common support coupled to the pyroelectric crystal, the deuterated or tritiated target, and the ion source. In another embodiment, a method includes producing a voltage of negative polarity on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using a voltage of the pyroelectric crystal and/or an HGI surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other apparatuses and methods are presented as well.

36 MATERIALS SCIENCE↗

Radial acceleration of ions during adiabatic expansion of a multicomponent cylindrical plasma

The methods of modern group analysis allow an analytic solution of the Cauchy problem to be constructed for the system of kinetic equations for a fully ionised electron – ion plasma, describing the acceleration of ions during the adiabatic expansion of a cylindrical plasma. Time and spatial dependences of the distribution functions of particles are obtained and their integral characteristics, such as density, average velocity, temperature, and energy spectrum, are found. The formation of the energy spectrum of accelerated ions, asymptotically repeating the spatial distribution of their density, and the cooling of electrons in the process of ion acceleration are analytically described. Particular attention is paid to the investigation of the influence of the heavy ionic component on the dynamics of the light component. The features of ion acceleration in the case of a two-temperature electron distribution function that describes the presence of hot and cold electron components are studied, which corresponds to the typical conditions of the experiment on plasma heating by intense laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Measurements of carbon-14 with cavity ring-down spectroscopy

Accelerator Mass Spectrometry (AMS) is the most sensitive method for quantitation of 14 C in biological samples. This technology has been used in a variety of low dose, human health related studies over the last 20 years when very high sensitivity was needed. AMS helped pioneer these scientific methods, but its expensive facilities and requirements for highly trained technical staff have limited their proliferation. Quantification of 14 C by cavity ring-down spectroscopy (CRDS) offers an approach that eliminates many of the shortcomings of an accelerator-based system and would supplement the use of AMS in biomedical research. Our initial prototype, using a non-ideal wavelength laser and under suboptimal experimental conditions, has a 3.5-modern, 1-σ precision for detection of milligram-sized, carbon-14-elevated samples. Furthermore, these results demonstrate proof of principle and provided a starting point for the development of a spectrometer capable of biologically relevant sensitivities.

07 ISOTOPE AND RADIATION SOURCES↗

Mechanical Performance of Additively Manufactured ODS 316L and 316H Stainless Steels

This work package within the Advanced Materials and Manufacturing Technologies (AMMT) program focused on the mechanical and microstructural characterization of oxide dispersion strengthened (ODS) stainless steels produced using advanced manufacturing techniques. The research aimed to identify an accelerated development path for ODS alloys by integrating additive manufacturing (AM) technologies with recent advancements in ODS materials and traditional manufacturing methods. For FY 24, the research specifically targeted exploring an accelerated development path for ODS alloys by combining AM technologies with these advancements. Novel AM and post-build processing routes were developed for ODS austenitic alloys, including Fe-Cr-Ni alloys such as 316L and 316H. Electron microscopy and mechanical characterizations were conducted to evaluate the impact of process variables on microstructure and properties, with the goal of optimizing these properties economically. Traditionally, producing ODS alloys involves multi-day, high-energy mechanical milling of alloy powder with yttria powder, followed by milled-powder consolidation through extrusion or other methods, and additional thermomechanical processing (TMP) for property control. To overcome the challenges associated with this complex and costly approach, we propose exploring alternative, cost-effective processing routes that emphasize AM and traditional TMP methods. The new processing routes for ODS alloys have achieved significantly higher strengths—several times greater than those of wrought stainless steels—while maintaining substantial ductility and fracture toughness. This report outlines the novel and economical AM-based processing routes for ODS austenitic alloys, combined with post-build TMPs, and discusses the mechanical and microstructural characteristics of the developed materials.

36 MATERIALS SCIENCE↗

Surgical Clips Assist in the Visualization of the Lumpectomy Cavity in Three-Dimensional Conformal Accelerated Partial-Breast Irradiation

Purpose: To determine to what extent the placement of surgical clips helps delineate the cavity in three-dimensional conformal accelerated partial-breast irradiation. Patients and Methods: Planning CT images of 100 lumpectomy cavities were reviewed in a cohort of 100 consecutive patients. The cavities were determined and categorized by two radiation oncologists according to cavity visualization score criteria and the breast density score. The two physicians first attempted to delineate the lumpectomy cavity without clips and then with clips. Results: In the case of high-density mammary tissue, the breast remodeling done during surgery does not enable the lumpectomy cavity to be sufficiently visualized. The use of surgical clips significantly improved the ability to visualize the lumpectomy cavity, with a 69% rate of concordance between physicians regardless of the breast tissue density. Conclusion: The placement of surgical clips at lumpectomy enables visualization of the lumpectomy cavity and allows upgrading of the cavity visualization score on CT scans obtained for accelerated partial-breast irradiation treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

10 Be at iThemba LABS using a silicon nitride membrane stack as absorber for isobar suppression

10 Be is an important isotope for accelerator mass spectrometry (AMS) because of the demand for cosmogenic radionuclide dating methods in the earth science and paleo-sciences community. At the iThemba Laboratory for Accelerator Based Science (iThemba LABS) we implemented full suppression of the interfering isobar 10 B using a silicon nitride foil-stack, utilizing the 2+ charge state for high efficiency. We demonstrate the performance of this newly established AMS system using standards and test samples. Here we further present the results of an inter-comparison between iThemba LABS and the Center for Accelerator Mass Spectrometry/Lawrence Livermore National Laboratory, on AMS samples prepared from purified quartz at the University of Vermont. The results for 10 Be from the laboratories are in close agreement, fully consistent with cross-calibration between them. AMS results for 26 Al are in similarly good agreement, demonstrating the performance and accuracy of iThemba LABS for the most commonly measured in situ produced cosmogenic nuclides.

10-Be↗

Modeling Pion and Nucleon Total Cross-sections

With an eye towards proposed experiments at the LHC, an earlier eikonal mini-jet model with soft gluons has now been extended to compute {pi}p and {pi}{pi} total cross-sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

SU-E-J-237: Image Feature Based DRR and Portal Image Registration

Purpose: Two-dimensional (2D) matching of the kV X-ray and digitally reconstructed radiography (DRR) images is an important setup technique for image-guided radiotherapy (IGRT). In our clinics, mutual information based methods are used for this purpose on commercial linear accelerators, but with often needs for manual corrections. This work proved the feasibility that feature based image transform can be used to register kV and DRR images. Methods: The scale invariant feature transform (SIFT) method was implemented to detect the matching image details (or key points) between the kV and DRR images. These key points represent high image intensity gradients, and thus the scale invariant features. Due to the poor image contrast from our kV image, direct application of the SIFT method yielded many detection errors. To assist the finding of key points, the center coordinates of the kV and DRR images were read from the DICOM header, and the two groups of key points with similar relative positions to their corresponding centers were paired up. Using these points, a rigid transform (with scaling, horizontal and vertical shifts) was estimated. We also artificially introduced vertical and horizontal shifts to test the accuracy of our registration method on anterior-posterior (AP) and lateral pelvic images. Results: The results provided a satisfactory overlay of the transformed kV onto the DRR image. The introduced vs. detected shifts were fit into a linear regression. In the AP image experiments, linear regression analysis showed a slope of 1.15 and 0.98 with an R2 of 0.89 and 0.99 for the horizontal and vertical shifts, respectively. The results are 1.2 and 1.3 with R2 of 0.72 and 0.82 for the lateral image shifts. Conclusion: This work provided an alternative technique for kV to DRR alignment. Further improvements in the estimation accuracy and image contrast tolerance are underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hardware acceleration for HPS algorithms in two and three dimensions

We provide a flexible, open-source framework for hardware acceleration, namely massively-parallel execution on general-purpose graphics processing units (GPUs), applied to the hierarchical Poincaré–Steklov (HPS) family of algorithms for building fast direct solvers for linear elliptic partial differential equations. To take full advantage of the power of hardware acceleration, we propose two variants of HPS algorithms to improve performance on two- and three-dimensional problems. In the two-dimensional setting, we introduce a novel recomputation strategy that minimizes costly data transfers to and from the GPU; in three dimensions, we modify and extend the adaptive discretization technique of Geldermans and Gillman [1] to greatly reduce peak memory usage. We provide an open-source implementation of these methods written in JAX, a high-level accelerated linear algebra package, which allows for the first integration of a high-order fast direct solver with automatic differentiation tools. We conclude with extensive numerical examples showing our methods are fast and accurate on two- and three-dimensional problems.

Fast direct solvers↗

Forward-backward asymmetry of top quark pair production

We adopt a Markov chain Monte Carlo method to examine various new physics models which can generate the forward-backward asymmetry in top quark pair production observed at the Tevatron by the CDF Collaboration. We study the following new physics models: (1) exotic gluon G{sup '}, (2) extra Z{sup '} boson with flavor-conserving interaction, (3) extra Z{sup '} with flavor-violating u-t-Z{sup '} interaction, (4) extra W{sup '} with flavor-violating d-t-W{sup '} interaction, and (5) extra scalars S and S{sup {+-}}with flavor-violating u-t-S and d-t-S{sup {+-}}interactions. After combining the forward-backward asymmetry with the measurement of the top pair production cross section and the tt invariant mass distribution at the Tevatron, we find that an axial vector exotic gluon G{sup '} of mass about 1 TeV or 2 TeV or a W{sup '} of mass about 2TeV offer an improvement over the standard model. The other models considered do not fit the data significantly better than the standard model. We also emphasize a few points that have been long ignored in the literature for new physics searches: (1) heavy resonance width effects, (2) renormalization scale dependence, and (3) next-to-leading order corrections to the tt invariant mass spectrum. We argue that these three effects are crucial to test or exclude new physics effects in the top quark pair asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Top Quark Amplitudes with an Anomolous Magnetic Moment

The anomalous magnetic moment of the top quark may be measured during the first run of the LHC at 7 TeV. For these measurements, it will be useful to have available tree amplitudes with t{bar t} and arbitrarily many photons and gluons, including both QED and color anomalous magnetic moments. In this paper, we present a method for computing these amplitudes using the Britto-Cachazo-Feng-Witten recursion formula. Because we deal with an effective theory with higher-dimension couplings, there are roadblocks to a direct computation with the Britto-Cachazo-Feng-Witten method. We evade these by using an auxiliary scalar theory to compute a subset of the amplitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty induced by QCD coupling in the CTEQ global analysis of parton distributions

We examine the dependence of parton distribution functions (PDFs) on the value of the QCD coupling strength {alpha}{sub s}(M{sub Z}). We explain a simple method that is rigorously valid in the quadratic approximation normally applied in PDF fitting, and fully reproduces the correlated dependence of theoretical cross sections on {alpha}{sub s} and PDF parameters. This method is based on a statistical relation that allows one to add the uncertainty produced by {alpha}{sub s}, computed with some special PDF sets, in quadrature with the PDF uncertainty obtained for the fixed {alpha}{sub s} value (such as the CTEQ6.6 PDF set). A series of four CTEQ6.6AS PDFs realizing this approach, for {alpha}{sub s} values in the interval 0.116{<=}{alpha}{sub s}(M{sub Z}){<=}0.120, is presented. Using these PDFs, the combined {alpha}{sub s} and PDF uncertainty is assessed for theoretical predictions at the Fermilab Tevatron and Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗