Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

SUPER-EDDINGTON FLUXES DURING THERMONUCLEAR X-RAY BURSTS

It has been known for nearly three decades that the energy spectra of thermonuclear X-ray bursts are often well fit by Planck functions with temperatures so high that they imply a super-Eddington radiative flux at the emitting surface, even during portions of bursts when there is no evidence of photospheric radius expansion. This apparent inconsistency is usually set aside by assuming that the flux is actually sub-Eddington and that the fitted temperature is so high because the spectrum has been distorted by the energy-dependent opacity of the atmosphere. Here we show that the spectra predicted by currently available conventional atmosphere models appear incompatible with the highest precision measurements of burst spectra made using the Rossi X-ray Timing Explorer, such as during the 4U 1820-30 superburst and a long burst from GX 17+2. In contrast, these measurements are well fit by Bose-Einstein spectra with high temperatures and modest chemical potentials. Such spectra are very similar to Planck spectra. They imply surface radiative fluxes more than a factor of 3 larger than the Eddington flux. We find that segments of many other bursts from many sources are well fit by similar Bose-Einstein spectra, suggesting that the radiative flux at the emitting surface also exceeds the Eddington flux during these segments. We suggest that burst spectra can closely approximate Bose-Einstein spectra and have fluxes that exceed the Eddington flux because they are formed by Comptonization in an extended, low-density radiating gas supported by the outward radiation force and confined by a tangled magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer

In weakly absorbing materials such as polymers and soft tissue, x-ray phase sensitive imaging methods can provide substantially enhanced contrast compared to classical, absorption based radiography. For specific applications, the latter can be applied in a dual energy scheme that helps to identify, discriminate and/or quantify materials. In this paper, we report on a new method that combines the idea of dual energy with x-ray phase contrast imaging and thus provides material sensitivity among poor absorbers. The dual energy modality cannot be applied in common phase contrast imaging schemes because of their demand for limited bandwidth or even monochromatic x-ray sources. Our new interferometric method based on diffraction gratings can overcome this shortcoming and thus simultaneously deliver x-ray phase contrast images for two distinct x-ray energy intervals. It has been shown that high quality images can be obtained with the dual energy phase setup. Energy spectra with 40 kV and 70 kV were applied to obtain low- and high-energy images, respectively. Furthermore, an estimation of the effective energy in the image formation process for absorption and phase contrast was experimentally determined. Examples are shown for which the dual energy phase contrast modality delivers complementary information on material composition when compared with the conventional dual energy scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fine structure in proton radioactivity: An accurate tool to ascertain the breaking of axial symmetry in {sup 145}Tm

With a proper formalism for proton emission from triaxially deformed nuclei, we perform exact calculations of decay widths for the decays to ground and first excited 2{sup +} states in the daughter nucleus. Our results for rotational spectrum, decay width and fine structure in the case of the nucleus {sup 145}Tm lead for the first time to an accurate identification of triaxial deformation using proton emission. This work also puts in evidence the advantage of proton emission over the conventional probes to study nuclear structure at the proton drip-line.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Variation of lead isotopic composition and atomic weight in terrestrial materials (IUPAC Technical Report)

The isotopic composition and atomic weight of lead are variable in terrestrial materials because its three heaviest stable isotopes are stable end-products of the radioactive decay of uranium ( 238 U to 206 Pb; 235 U to 207 Pb) and thorium ( 232 Th to 208 Pb). The lightest stable isotope, 204 Pb, is primordial. These variations in isotope ratios and atomic weights provide useful information in many areas of science, including geochronology, archaeology, environmental studies, and forensic science. While elemental lead can serve as an abundant and homogeneous isotopic reference, deviations from the isotope ratios in other lead occurrences limit the accuracy with which a standard atomic weight can be given for lead. In a comprehensive review of several hundred publications and analyses of more than 8000 samples, published isotope data indicate that the lowest reported lead atomic weight of a normal terrestrial materials is 206.1462 ± 0.0028 (k = 2), determined for a growth of the phosphate mineral monazite around a garnet relic from an Archean high-grade metamorphic terrain in north-western Scotland, which contains mostly 206 Pb and almost no 204 Pb. The highest published lead atomic weight is 207.9351 ± 0.0005 (k = 2) for monazite from a micro-inclusion in a garnet relic, also from a high-grade metamorphic terrain in north-western Scotland, which contains almost pure radiogenic 208 Pb. When expressed as an interval, the lead atomic weight is [206.14, 207.94]. It is proposed that a value of 207.2 be adopted for the single lead atomic-weight value for education, commerce, and industry, corresponding to previously published conventional atomic-weight values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exceptional Radiation Absorption in a Pentagon-Based Si Allotrope

Excellent photovoltaic performance is predicted in a pentagonal covalent network of Si in a hollow structure exhibiting both thermal and dynamical stability. Consisting of a combination of sp 2 and sp 3 hybridized Si atomic orbitals, the GW0 computed band structure shows an indirect band gap near the zone edge and also a manifold of directly absorbing transitions at frequencies in the window of visible light, in distinction with conventional Si. Hydrogenation of a single sp 2 site is predicted to lead to a robust local magnetic moment. In this study, we find a low formation energy at low pressure that is compatible with other experimentally known phases, suggesting that a stable phase might be obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Novel Application of Helical Tomotherapy in Whole Skull Palliative Radiotherapy

Helical tomotherapy (HT) is a radiation planning/delivery platform that combines inversely planned IMRT with on-board megavoltage imaging. A unique HT radiotherapy whole skull brain sparing technique is described in a patient with metastatic prostate cancer. An inverse HT plan and an accompanying back-up conventional lateral 6-MV parallel opposed pair (POP) plan with corresponding isodose distributions and dose-volume histograms (DVH) were created and assessed prior to initiation of therapy. Plans conforming to the planning treatment volume (PTV) with significant sparing of brain, optic nerve, and eye were created. Dose heterogeneity to the PTV target was slightly higher in the HT plan compared to the back-up POP plan. Conformal sparing of brain, optic nerve, and eye was achieved by the HT plan. Similar lens and brain stem/spinal cord doses were seen with both plans. Prospective clinical evaluation with relevant end points (quality of life, symptom relief) are required to confirm the potential benefits of highly conformal therapies applied to palliative situations such as this case.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temporal and temperature evolution of electric field in CdTe:In radiation detectors

We employed measurement of the Pockels electro-optic effect to study the electric field and space charge dynamics in semi-insulating CdTe doped with indium. We performed measurements of time and temperature dependence of the electric field. The polarization due to space charge build-up decreases with increasing temperature. Increase of temperature, therefore, leads to de-polarization in CdTe:In detectors which are opposite to the CdTe:Cl samples studied to date. We have shown that the thermally activated depolarization cannot be explained by the conventional model used for the description of space charge formation so far and an alternative model involving a recombination level was suggested and successfully used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airborne hyperspectral imaging of cover crops through radiative transfer process-guided machine learning

Cover cropping between cash crop growing seasons is a multifunctional conservation practice. Timely and accurate monitoring of cover crop traits, notably aboveground biomass and nutrient content, is beneficial to agricultural stakeholders to improve management and understand outcomes. Currently, there is a scarcity of spatially and temporally resolved information for assessing cover crop growth. Remote sensing has a high potential to fill this need, but conventional empirical regression operated with coarse-resolution multispectral data has large uncertainties. Therefore, this study utilized airborne hyperspectral imaging techniques and developed new process-guided machine learning approaches (PGML) for cover crop monitoring. Specifically, we deployed an airborne hyperspectral system covering visible to shortwave-infrared wavelengths (400–2400 nm) to acquire high spatial (0.5 m) and spectral (3–5 nm) resolution reflectance over 23 cover crop fields across Central Illinois in March and April of 2021. Airborne hyperspectral surface reflectance with high spectral and spatial resolution can be well matched with field data to quantify cover crop traits. Furthermore, the PGML models were pre-trained by synthetic data from soil-vegetation radiative transfer modeling (one million records), and then fine-tuned with field data of cover crop biomass and nutrient content. Results show that airborne hyperspectral data with PGML can achieve high accuracy to predict cover crop aboveground biomass (R 2 = 0.72, relative RMSE = 15.16%) and nitrogen content (R 2 = 0.69, relative RMSE = 16.59%) through leave-one-field-out cross-validation. Unlike the pure data-driven approach (e.g., partial least-squares regression), PGML incorporated radiative transfer knowledge and obtained higher predictive performance with fewer field data. Meanwhile, with field data for model fine-tuning, PGML predicted biomass more accurately than the inversion of radiative transfer models. Here we also found that the red edge has a high contribution in quantifying aboveground biomass and nitrogen content, followed by green and shortwave spectra. This study demonstrated the first attempt of utilizing hyperspectral remote sensing to accurately quantify cover crop traits. We highlight the strength of PGML in exploiting sensing data to quantify ecosystem variables to advance agroecosystem monitoring for sustainable agricultural management.

60 APPLIED LIFE SCIENCES↗

Laser induced focusing for over-dense plasma beams

The capability of ion acceleration with high power, pulsed lasers has become an active field of research in the past years. In this context, the radiation pressure acceleration (RPA) mechanism has been the topic of numerous theoretical and experimental publications. Within that mechanism, a high power, pulsed laser beam hits a thin film target. In contrast to the target normal sheath acceleration, the entire film target is accelerated as a bulk by the radiation pressure of the laser. Simulations predict heavy ion beams with kinetic energy up to GeV, as well as solid body densities. However, there are several effects which limit the efficiency of the RPA: On the one hand, the Rayleigh-Taylor-instability limits the predicted density. On the other hand, conventional accelerator elements, such as magnetic focusing devices are too bulky to be installed right after the target. Therefore, we present a new beam transport method, suitable for RPA-like/over-dense plasma beams: laser induced focusing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced Emission from Bright Excitons in Asymmetrically Strained Colloidal CdSe/Cd x Zn 1– x Se Quantum Dots

Colloidal CdSe quantum dots (QDs) designed with a high degree of asymmetric internal strain have recently been shown to host a number of desirable optical properties including subthermal room-temperature line widths, suppressed spectral diffusion, and high photoluminescence (PL) quantum yields. It remains an open question, however, whether they are well-suited for applications requiring emission of identical single photons. Here we measure the low-temperature PL dynamics and the polarization-resolved fluorescence line narrowing spectra from ensembles of these strained QDs. Our spectroscopy reveals the radiative recombination rates of bright and dark excitons, the relaxation rate between the two, and the energy spectra of the quantized acoustic phonons in the QDs that can contribute to relaxation processes. In comparison to conventional colloidal CdSe/ZnS core/shell QDs, we find that in asymmetrically strained CdSe QDs over six times more light is emitted directly by the bright exciton. Furthermore, these results are therefore encouraging for the prospects of chemically synthesized colloidal QDs as emitters of single indistinguishable photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of KENO-VI and MCNP5 Criticality Analyses for a Lunar Regolith Clustered-Reactor System

The Lunar Regolith Clustered-Reactor System design has been presented as an alternative method for providing surface power to a lunar facility using a fast-fission, heatpipe-cooled nuclear reactor. The reactor system is divided into subcritical units that can be safely launched into orbit without risk of inadvertent criticality in the event of a launch accident. The reactor subunits are emplaced into the lunar surface to form a clustered-reactor system, utilizing the regolith as both radiation shielding and neutron-reflector material. Coordinated placement of multiple subunits can provision a critical reactor system proportional to localized lunar surface power demand. Reactor units assembled using proven and tested materials in radiation environments such as UO{sub 2} fuel, stainless-steel cladding and support, and compatible liquid-metal heatpipes promote safety and reliability, with ease of manufacture and testing. Reactor power levels of approximately 100 kWth per subunit significantly reduces the negative effects of elevated temperature and radiation environments associated with single nuclear power reactors operated at higher power levels. The analysis of subunit criticality in various accident scenarios differs by up to 4% ({approx}$6 in reactivity) between results generated using conventional criticality analysis codes, MCNP5 and KENO-VI. A demonstrated trend exists between results of the two criticality codes as accident conditions approach a multiplication factor of one. Code comparison of a tri-cluster system on the lunar surface provides comparable results with calculated system reactivity within 0.5%. Iron concentration is confirmed as the dominant element in the lunar regolith influencing system reactivity.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative study of INPIStron and spark gap

An inverse pinch plasma switch, INPIStron, was studied in comparison to a conventional spark gap. The INPIStron is under development for high power switching applications. The INPIStron has an inverse pinch dynamics, opposed to Z-pinch dynamics in the spark gap. The electrical, plasma dynamics and radiative properties of the closing plasmas have been studied. Recently the high-voltage pulse transfer capabilities or both the INPIStron and the spark gap were also compared. The INPIStron with a low impedance Z = 9 ohms transfers 87 percent of an input pulse with a halfwidth of 2 mu s. For the same input pulse the spark gap of Z = 100 ohms transfers 68 percent. Fast framing and streak photography, taken with an TRW image converter camera, was used to observe the discharge uniformity and closing plasma speed in both switches. In order to assess the effects of closing plasmas on erosion of electrode material, emission spectra of two switches were studied with a spectrometer-optical multi channel analyzer (OMA) system. The typical emission spectra of the closing plasmas in the INPIStron and the spark gap showed that there were comparatively weak carbon line emission in 658.7 nm and copper (electrode material) line emissions in the INPIStron, indicating low erosion of materials in the INPIStron.

Han, Kwang S.↗

POSS(Registered TradeMark) Coatings for Solar Cells: An Update

Presently, solar cells are covered with Ce-doped microsheet cover glasses that are attached with Dow Corning DC 93-500 silicone adhesive. Various antireflection coatings are often applied to the cover glass to increase cell performance. This general approach has been used from the beginning of space exploration. However, it is expensive and time consuming. Furthermore, as the voltage of solar arrays increases, significant arcing has occurred in solar arrays, leading to loss of satellite power. The cause has been traced to differential voltages between strings and the close spacing between them with no insulation covering the edges of the solar cells. In addition, this problem could be ameliorated if the cover glass extended over the edges of the cell, but this would impact packing density. An alternative idea that might solve all these issues and be less expensive and more protective is to develop a coating that could be applied over the entire array. Such a coating must be resistant to atomic oxygen for low earth orbits below about 700 km, it must be resistant to ultraviolet radiation for all earth and near-sun orbits and, of course, it must withstand the damaging effects of space radiation. Coating flexibility would be an additional advantage. Based on past experience, one material that has many of the desired attributes of a universal protective coating is the Dow Corning DC 93-500. Of all the potential optical plastics, it appears to be the most suitable for use in space. As noted above, DC 93-500 has been extensively used to attach cover glasses to crystalline solar cells and has worked exceptionally well over the years. It is flexible and generally resistant to electrons, protons and ultraviolet (UV and VUV) radiation; although a VUV-rejection coating or VUV-absorbing ceria-doped cover glass may be required for long mission durations. It can also be applied in a thin coating (< 25 m) by conventional liquid coating processes. Unfortunately, when exposed to atomic oxygen (AO) DC 93-500 develops a frosty surface. Such frosting can lead to a loss of light transmitted into the cells and destroy the essential clarity needed for a concentrator lens.

Brandhorst, Henry↗

In-situ X-ray photoelectron spectroscopy studies of water on metals and oxides at ambient conditions

X-ray photoelectron spectroscopy (XPS) is a powerful tool for surface and interface analysis, providing the elemental composition of surfaces and the local chemical environment of adsorbed species. Conventional XPS experiments have been limited to ultrahigh vacuum (UHV) conditions due to a short mean free path of electrons in a gas phase. The recent advances in instrumentation coupled with third-generation synchrotron radiation sources enables in-situ XPS measurements at pressures above 5 Torr. In this review, we describe the basic design of the ambient pressure XPS setup that combines differential pumping with an electrostatic focusing. We present examples of the application of in-situ XPS to studies of water adsorption on the surface of metals and oxides including Cu(110), Cu(111), TiO2(110) under environmental conditions of water vapor pressure. On all these surfaces we observe a general trend where hydroxyl groups form first, followed by molecular water adsorption. The importance of surface OH groups and their hydrogen bonding to water molecules in water adsorption on surfaces is discussed in detail.

36 MATERIALS SCIENCE↗

Improvement of Aerosol Optical Depth Retrieval over Hong Kong from a Geostationary Meteorological Satellite Using Critical Reflectance with Background Optical Depth Correction

Despite continuous efforts to retrieve aerosol optical depth (AOD) using a conventional 5-channelmeteorological imager in geostationary orbit, the accuracy in urban areas has been poorer than other areas primarily due to complex urban surface properties and mixed aerosol types from different emission sources. The two largest error sources in aerosol retrieval have been aerosol type selection and surface reflectance. In selecting the aerosol type from a single visible channel, the season-dependent aerosol optical properties were adopted from longterm measurements of Aerosol Robotic Network (AERONET) sun-photometers. With the aerosol optical properties obtained fromthe AERONET inversion data, look-up tableswere calculated by using a radiative transfer code: the Second Simulation of the Satellite Signal in the Solar Spectrum (6S). Surface reflectance was estimated using the clear sky composite method, awidely used technique for geostationary retrievals. Over East Asia, the AOD retrieved from the Meteorological Imager showed good agreement, although the values were affected by cloud contamination errors. However, the conventional retrieval of the AOD over Hong Kong was largely underestimated due to the lack of information on the aerosol type and surface properties. To detect spatial and temporal variation of aerosol type over the area, the critical reflectance method, a technique to retrieve single scattering albedo (SSA), was applied. Additionally, the background aerosol effect was corrected to improve the accuracy of the surface reflectance over Hong Kong. The AOD retrieved froma modified algorithmwas compared to the collocated data measured by AERONET in Hong Kong. The comparison showed that the new aerosol type selection using the critical reflectance and the corrected surface reflectance significantly improved the accuracy of AODs in Hong Kong areas,with a correlation coefficient increase from0.65 to 0.76 and a regression line change from τMI [basic algorithm] = 0.41τAERONET + 0.16 to τMI [new algorithm] = 0.70τAERONET + 0.01.

aerosols↗

Note: Application of laser produced plasma K{alpha} x-ray probe in radiation biology

A dedicated radiation biology x-ray generation and exposure system has been developed. 8.0 keV in energy x-ray pulses generated with a femtosecond-laser pulse was used to irradiate sample cells through a custom-made culture dish with a silicon nitride membrane. The x-ray irradiation resulted in DNA double-strand breaks in the nucleus of a culture cell that were similar to those obtained with a conventional x-ray source, thus demonstrating the feasibility of radiobiological studies utilizing a single burst of x-rays focused on single cell specimens.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗