Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Stress Testing the Standard Model of Particle Physics at the Large Hadron Collider

Final technical report for the DOE grant "Stress Testing the Standard Model of Particle Physics at the Large Hadron Collider", awarded to Prof. Aram Apyan at Brandeis University. The work focused on the ATLAS experiment at LHC. During the award period the group worked on ATLAS physics analyses, all-silicon Inner Tracker (ITk) detector upgrade, and reconstruction and calibration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BiPo: A dedicated radiopurity detector for the SuperNEMO experiment

New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m{sup 2}, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Science Training Program for Young Italian Physicists and Engineers at Fermilab

Since 1984 Fermilab has been hosting a two-month summer training program for selected undergraduate and graduate Italian students in physics and engineering. Building on the traditional close collaboration between the Italian National Institute of Nuclear Physics (INFN) and Fermilab, the program is supported by INFN, by the DOE and by the Scuola Superiore di Sant`Anna of Pisa (SSSA), and is run by the Cultural Association of Italians at Fermilab (CAIF). This year the University of Pisa has qualified it as a “University of Pisa Summer School”, and will grant successful students with European Supplementary Credits. Physics students join the Fermilab HEP research groups, while engineers join the Particle Physics, Accelerator, Technical, and Computing Divisions. Some students have also been sent to other U.S. laboratories and universities for special trainings. The programs cover topics of great interest for science and for social applications in general, like advanced computing, distributed data analysis, nanoelectronics, particle detectors for earth and space experiments, high precision mechanics, applied superconductivity. In the years, over 350 students have been trained and are now employed in the most diverse fields in Italy, Europe, and the U.S. In addition, the existing Laurea Program in Fermilab Technical Division was extended to the whole laboratory, with presently two students in Master’s thesis programs on neutrino physics and detectors in the Neutrino Division. And finally, a joint venture with the Italian Scientists and Scholars North-America Foundation (ISSNAF) provided this year 4 professional engineers free of charge for Fermilab. More details on all of the above can be found below.

Barzi, Emanuela↗

Space Detectors for Gamma Rays (100 MeV-100 GeV): from Egret to Fermi LAT

The design of spaceborne high-energy (E is greater than 100 MeV) gamma-ray detectors depends on two principal factors: (1) the basic physics of detecting and measuring the properties of the gamma rays; and (2) the constraints of operating such a detector in space for an extended period. Improvements in technology have enabled major advances in detector performance, as illustrated by two successful instruments, EGRET on the Compton Gamma Ray Observatory and LAT on the Fermi Gamma-ray Space Telescope.

Gamma rays Detectors Space↗

Neutrons and their Detection with Silicon Diodes

In this lecture we review the basic principles and properties of neutrons as probes for fundamental and applied research studies. We outline the nuclear reactions used for neutron sources and neutron detectors and techniques of filtered neutron beams and time-of-flight. We summarize the interaction, transport and shielding of neutrons in matter. We concentrate on the reactions employed for detection of neutrons as well as on their interaction in silicon. We indicate the features of materials used as neutron converters and highlight areas with broad applications of neutrons.

43 PARTICLE ACCELERATORS↗

Neutrino Flavor Classification in ICARUS Experiment Using Convolutional Visual Networks

In this work, I adapt the Convolutional Visual Network (CVN) approach to the ICARUS detector by incorporating TPC stitching methods inspired by NuGraph. The stitching technique used here is unique to ICARUS, designed specifically to handle its distinct detector segmentation s. I then retrain the network using ICARUS-specific data. This study underscores the flexibility of deep learning models in high-energy physics and the importance of accounting for detector-specific features when transferring machine learning techniques between experiments. This dissertation presents the methods, classification performance, and insights gained from applying CVN to ICARUS data.

Wieler, Felipe Andre [Parana Tech. Fed. U., Toledo↗

Recent Electroweak Results from the Tevatron

W and Z bosons are mainly produced via quark-antiquark annihilations at the Fermilab Tevatron collider. Precision measurements with these gauge bosons provide us with high precision tests of the Standard Model (SM) as well as indirect search for possible new physics beyond the SM. I present the recent electroweak measurements related to single W, Z boson and diboson productions from the CDF and D0 experiments at the Fermilab Tevatron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the masses, lifetimes and decay modes of hadrons at Tevatron

The Tevatron provides 1.96 TeV p{bar p} collisions and allows for collection of rich b-hadron samples to the two experiments CDF and D0. The study of heavy flavor properties represents a fruitful opportunity to investigate the flavor sector of the Standard Model (SM) and to look for hints of New Physics (NP). Here we report the first measurement of polarization amplitudes in B{sub s}{sup 0} charmless decays, world leading results on b-hadron lifetimes, and measurements of several other properties of b-hadrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single and Double Top Quark Production at the Tevatron

The CDF and D0 experiments have measured single and double top quark production in ppbar collisions at the Tevatron at a centre-of-mass energy of 1.96TeV. The applied methods are used to constrain properties of the top quark and to search for new physics. Several methods of signal to background separation and of the estimation of the background contributions are discussed. Experimental results using an integraged luminosity up to 5.3fb{sup -1} are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SUSY searches at Tevatron

Search for Supersymmetry is a predominant experimental preoccupation because Supersymmetry gives theoretically appealing solutions to several significant issues in particle physics as well as in cosmology. CDF and D0 experiments at the Tevatron collider at Fermilab are carrying out multipronged strategies to discern Supersymmetry on the background of Standard Model processes. Here, I give an elementary introduction to Supersymmetry and then follow it by outlining recent search results from the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucifer: A small electron-antineutrino detector for fundamental and safeguard studies

The Nucifer detector will be deployed in the next few months at the Osiris research reactor in France. Nucifer is a 1-ton Gd-doped liquid scintillator detector devoted to reactor antineutrino studies. It will be installed 7 m away from the compact core of the Osiris reactor. The design of such small volume detector has been focused on high detection efficiency and good background rejection. Over the last decades, our understanding of the neutrino properties has been improved and allows today the possibility to apply the detection of antineutrinos to automatic and to non intrusively survey nuclear power plant. This has triggered the interest of the International Atomic Energy Agency (IAEA), which is interested by developing new safeguard techniques for next generation reactors. The sensitivity of such technique has to be proved and demonstrated. On the other hand there is still some issues in our understanding of the neutrino properties as the observed deficit in the antineutrino rate at short distances (< 100 m) that can not be explained by oscillations in the 3-flavors neutrino model. If a global systematic error is rejected, such anomaly opens the door to new physic that can be assessed with small detectors placed close to the core. Here we review the Nucifer detector in this context and the tests we are performing. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a novel two dimensional diode array the ''magic plate'' as a radiation detector for radiation therapy treatment

Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the ''magic plate'' (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. Methods: The prototype MP is an 11 x 11 detector array based on thin (50 {mu}m) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary ''drop-in'' technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Results: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180 deg. Angular dependence was within 3.5% for the gantry angles {+-} 75 deg. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 x 30 cm{sup 2} field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. Conclusions: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with ''drop-in'' packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the Run IIB D0 Luminosity System and Determination of the Run IIB Luminosity Constant

The luminosity system is an integral part of the D0 detector that must be properly maintained to provide accurate luminosity measurements for physics analysis. After the addition of a readout layer to the silicon vertex detector in 2006, it was necessary to re-calculate the effective inelastic cross section to which the luminosity monitor is sensitive. The preliminary analysis showed that the luminosity constant did not change with the addition of the extra layer of silicon. A full study of the revised luminosity constant including a complete analysis of systematic uncertainties has been completed. The luminosity constant was determined to be {sigma}{sub eff} = 48.3 {+-} 1.9 {+-} 0.6 mb, which reduces the D0 contribution to the luminosity measurement uncertainty by almost 3%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Energy Physics at Tufts University Final Report

In this Final Report, we the researchers of the high energy physics group at Tufts University summarize our works and achievements in three frontier areas of elementary particle physics: (i) Neutrino physics at the Intensity Frontier, (ii) Collider physics at the Energy Frontier, and (iii) Theory investigations of spin structure and quark-gluon dynamics of nucleons using quantum chromodynamics. With our Neutrino research we completed, or else brought to a useful state, the following: Data-taking, physics simulations, physics analysis, physics reporting, explorations of matter effects, and detector component fabrication. We conducted our work as participants in the MINOS, NOvA, and LBNE neutrino oscillation experiments and in the MINERvA neutrino scattering experiment. With our Collider research we completed or else brought to a useful state: Data-taking, development of muon system geometry and tracking codes, software validation and maintenance, physics simulations, physics analysis, searches for new particles, and study of top-quark and B-quark systems. We conducted these activities as participants in the ATLAS proton-proton collider experiment at CERN and in the CDF proton-antiproton collider experiment at Fermilab. In our Theory research we developed QCD-based models, applications of spin phenomenology to fundamental systems, fitting of models to data, presenting and reporting of new concepts and formalisms. The overarching objectives of our research work have always been: 1) to test and clarify the predictions of the Standard Model of elementary particle physics, and 2) to discover new phenomena which may point the way to a more unified theoretical framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-performance data format for scientific data storage and analysis

Here, in this article, we present the High-Performance Output (HiPO) data format developed at Jefferson Laboratory for storing and analyzing data from Nuclear Physics experiments. The format was designed to efficiently store large amounts of experimental data, utilizing modern fast compression algorithms. The purpose of this development was to provide organized data in the output, facilitating access to relevant information within the large data files. The HiPO data format has features that are suited for storing raw detector data, reconstruction data, and the final physics analysis data efficiently, eliminating the need to do data conversions through the lifecycle of experimental data. The HiPO data format is implemented in C++ and JAVA, and provides bindings to FORTRAN, Python, and Julia, providing users with the choice of data analysis frameworks to use. In this paper, we will present the general design and functionalities of the HiPO library and compare the performance of the library with more established data formats used in data analysis in High Energy and Nuclear Physics (such as ROOT and Parquete). In columnar data analysis, HiPO surpasses established data formats in performance and can be effectively applied to data analysis in other scientific fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nucleon and Nuclear Structure Studies in Electroproduction with the CLAS Detector at Jefferson Lab

A diverse program for studying the structure of nucleons and nuclei is underway using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. A wealth of data has been obtained in inclusive, semi-inclusive, and exclusive electroproduction reactions using a variety of unpolarized and polarized beams and targets. The results include studies of excited nucleon states, measurements of nucleon, proton and neutron Form Factors (FFs), Parton Distribution Functions (PDFs), Transverse Momentum Distributions (TMDs), and Generalized Parton Distributions (GPDs), as well as Short Range Correlations (SRCs) in nuclei and Color Transparency phenomena. Jefferson Lab's electron accelerator, CEBAF, doubled its energy to 12~GeV and the upgrade of the experimental equipment is near completion in the experimental halls. The upgraded CLAS detector, CLAS12, enables execution of a broader physics program, with the main focus on uncovering the TMDs and GPDs using semi-inclusive and exclusive reactions in a new kinematic domain. In this talk, an overview of the CLAS electroproduction measurements with 6~GeV CEBAF and prospects of nucleon and nuclear structure studies with the 12~GeV machine and the CLAS12 detector will be discussed.

Stepanyan, Stepan↗