Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Optimal distribution system restoration using PHEVs

Power outages cost billions of dollars every year and jeopardise the lives of hospital patients. Traditionally, power distribution system takes a long time to recover after a major blackout, due to its top-down operation strategy. New technologies in modern distribution systems bring opportunities and challenges to distribution system restoration. As fast response energy resources, plug-in hybrid electric vehicles (PHEVs) can accelerate the load pickup by compensating the imbalance between available generation and distribution system load. This study provides a bottom-up restoration strategy to use PHEVs for reliable load pickup and faster restoration process. The optimisation problem of finding load pickup sequence to maximise restored energy is formulated as a mixed integer linear programming (MILP) problem. Moreover, the coordination between transmission and distribution restoration is developed to efficiently restore the entire system back to normal operating conditions. Simulation results on one 100-feeder test system demonstrate the efficiency of MILP-based restoration strategy and the benefit from PHEVs to restore more energy in given restoration time. The proposed restoration strategy has great potential to facilitate system operators to achieve efficient system restoration plans. It also provides incentives to deploy a large amount of PHEVs to improve system resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Angular distribution of atoms ejected by laser ablation of different metals

Angular distributions of 13 different metals ejected by laser ablation using fourth harmonics (wavelength=266 nm) of neodymium doped yttrium aluminum garnet laser and a fluence close to near-threshold value (2.3 J/cm{sup 2}) have been investigated with a high angular resolution. The angular distribution which is characterized by the exponent n of cos{sup n} theta distribution showed very broad range of values between 3 and 24 for different metals. A simple relation that the exponent n is proportional to the square root of particle atomic weight as reported previously has not been observed. Instead, a general trend has been found that the metals with higher sublimation energy such as Ta and Zr show narrower angular distribution than those with lower sublimation energy such as Sn and In. While the sublimation energy of metals has a great influence on the angular distribution of ejected atoms, a simple consideration suggests that their thermal conductivity and specific heat have little effect on it.

36 MATERIALS SCIENCE↗

Unstable density distribution associated with equatorial plasma bubble

In this work, we present a simulation study of equatorial plasma bubble (EPB) in the evening time ionosphere. The fluid simulation is performed with a high grid resolution, enabling us to probe the steepened updrafting density structures inside EPB. Inside the density depletion that eventually evolves as EPB, both density and updraft are functions of space from which the density as implicit function of updraft velocity or the density distribution function is constructed. In the present study, this distribution function and the corresponding probability distribution function are found to evolve from Maxwellian to non-Maxwellian as the initial small depletion grows to EPB. This non-Maxwellian distribution is of a gentle-bump type, in confirmation with the recently reported distribution within EPB from space-borne measurements that offer favorable condition for small scale kinetic instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RADIAL DISTRIBUTION OF X-RAY POINT SOURCES NEAR THE GALACTIC CENTER

We present the log N-log S and spatial distributions of X-ray point sources in seven Galactic bulge (GB) fields within 4 deg. from the Galactic center (GC). We compare the properties of 1159 X-ray point sources discovered in our deep (100 ks) Chandra observations of three low extinction Window fields near the GC with the X-ray sources in the other GB fields centered around Sgr B2, Sgr C, the Arches Cluster, and Sgr A* using Chandra archival data. To reduce the systematic errors induced by the uncertain X-ray spectra of the sources coupled with field-and-distance-dependent extinction, we classify the X-ray sources using quantile analysis and estimate their fluxes accordingly. The result indicates that the GB X-ray population is highly concentrated at the center, more heavily than the stellar distribution models. It extends out to more than 1.{sup 0}4 from the GC, and the projected density follows an empirical radial relation inversely proportional to the offset from the GC. We also compare the total X-ray and infrared surface brightness using the Chandra and Spitzer observations of the regions. The radial distribution of the total infrared surface brightness from the 3.6 band mum images appears to resemble the radial distribution of the X-ray point sources better than that predicted by the stellar distribution models. Assuming a simple power-law model for the X-ray spectra, the closer to the GC the intrinsically harder the X-ray spectra appear, but adding an iron emission line at 6.7 keV in the model allows the spectra of the GB X-ray sources to be largely consistent across the region. This implies that the majority of these GB X-ray sources can be of the same or similar type. Their X-ray luminosity and spectral properties support the idea that the most likely candidate is magnetic cataclysmic variables (CVs), primarily intermediate polars (IPs). Their observed number density is also consistent with the majority being IPs, provided the relative CV to star density in the GB is not smaller than the value in the local solar neighborhood.

79 ASTRONOMY AND ASTROPHYSICS↗

A measurement of the turbulence-driven density distribution in a non-star-forming molecular cloud

Molecular clouds are supersonically turbulent. This turbulence governs the initial mass function and the star formation rate. In order to understand the details of star formation, it is therefore essential to understand the properties of turbulence, in particular the probability distribution of density in turbulent clouds. We present H{sub 2}CO volume density measurements of a non-star-forming cloud along the line of sight toward W49A. We use these measurements in conjunction with total mass estimates from {sup 13}CO to infer the shape of the density probability distribution function. This method is complementary to measurements of turbulence via the column density distribution and should be applicable to any molecular cloud with detected CO. We show that turbulence in this cloud is probably compressively driven, with a compressive-to-total Mach number ratio b=M{sub C}/M>0.4. We measure the standard deviation of the density distribution, constraining it to the range 1.5 < σ {sub s} < 1.9, assuming that the density is lognormally distributed. This measurement represents an essential input into star formation laws. The method of averaging over different excitation conditions to produce a model of emission from a turbulent cloud is generally applicable to optically thin line observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron distribution functions in solar flares from combined X-ray and extreme-ultraviolet observations

Simultaneous solar flare observations with SDO and RHESSI provide spatially resolved information about hot plasma and energetic particles in flares. RHESSI allows the properties of both hot (≳8 MK) thermal plasma and non-thermal electron distributions to be inferred, while SDO/AIA is more sensitive to lower temperatures. We present and implement a new method to reconstruct electron distribution functions from SDO/AIA data. The combined analysis of RHESSI and AIA data allows the electron distribution function to be inferred over the broad energy range from 0.1 keV up to a few tens of keV. The analysis of two well-observed flares suggests that the distributions in general agree to within a factor of three when the RHESSI values are extrapolated into the intermediate range 1-3 keV, with AIA systematically predicting lower electron fluxes. Possible instrumental and numerical effects, as well as potential physical origins for this discrepancy, are discussed. The inferred electron distribution functions in general show one or two nearly Maxwellian components at energies below ∼15 keV and a non-thermal tail above.

79 ASTRONOMY AND ASTROPHYSICS↗

The formation of kappa-distribution accelerated electron populations in solar flares

Driven by recent RHESSI observations of confined loop-top hard X-ray sources in solar flares, we consider stochastic acceleration of electrons in the presence of Coulomb collisions. If electron escape from the acceleration region can be neglected, the electron distribution function is determined by a balance between diffusive acceleration and collisions. Such a scenario admits a stationary solution for the electron distribution function that takes the form of a kappa distribution. We show that the evolution toward this kappa distribution involves a 'wave front' propagating forward in velocity space, so that electrons of higher energy are accelerated later; the acceleration timescales with energy according to τ{sub acc} ∼ E {sup 3/2}. At sufficiently high energies escape from the finite-length acceleration region will eventually dominate. For such energies, the electron velocity distribution function is obtained by solving a time-dependent Fokker-Planck equation in the 'leaky-box' approximation. Solutions are obtained in the limit of a small escape rate from an acceleration region that can effectively be considered a thick target.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MASS DISTRIBUTION FUNCTION OF PLANETS

The distribution of orbital period ratios of adjacent planets in extrasolar planetary systems discovered by the Kepler space telescope exhibits a peak near ∼1.5–2, a long tail of larger period ratios, and a steep drop-off in the number of systems with period ratios below ∼1.5. We find from these data that the dimensionless orbital separations have an approximately log-normal distribution. Using Hill’s criterion for the dynamical stability of two planets, we find an upper bound on planet masses such that the most common planet mass does not exceed 10{sup −3.2}m{sub ∗}, or about two-thirds of Jupiter’s mass for solar-mass stars. Assuming that the mass ratio and the dynamical separation (orbital spacings in units of mutual Hill radius) of adjacent planets are independent random variates, and adopting empirical distributions for these, we use Hill’s criterion in a statistical way to estimate the planet mass distribution function from the observed distribution of orbital separations. We find that the planet mass function is peaked in logarithm of mass, with a peak value and standard deviation of logm/M{sub ⊕} of ∼(0.6−1.0) and ∼(1.1−1.2), respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of spin distribution for several fission reaction systems induced by nucleons and heavy ions

Compound nucleus spin distribution has been calculated for several fission reaction systems induced by nucleons and heavy ions. Determination of the spin distribution for these systems is based upon the comparison between the experimental data of the fission fragment angular distributions as well as the prediction of the standard saddle-point statistical model (SSPSM). For the systems, the two cases, namely with and without neutron emission corrections were considered. This method is used for the first time to determine compound nucleus spin distribution. Afterwards, our theoretical results have been compared with the data obtained from the coupled-channel technique as well as the Wong model, and satisfactory agreements were found. Furthermore, we have introduced a semiclassical approximation relation for the compound nucleus spin distribution of these systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ensuring System Reliability: Distributed Energy Resources and Bulk Power System Considerations

Rooftop solar energy, storage batteries, and electric vehicles are changing the way people use and produce electricity. These are among the growing set of technologies called distributed energy resources (DERs) because they are typically connected to the utility at the medium-voltage distribution system. In general, the utility distribution system connects substations to homes and businesses. The effect of DE Rs on operating the power grid has been dramatic and exciting, and they provide both challenges and benefits to the entire grid: spanning utilization, distribution, and transmission voltage ranges. The zero-carbon resources among the broader family of DE Rs are critical in complying with state and federal energy policies. This, in turn, has required grid operators, utilities, regulators, consumer advocates, and lawmakers to reach out across traditional domains to engage in the robust dialog and coordination needed to integrate distribution-level resources to the larger high-voltage grid and the networked bulk power systems (BPSs).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Post-Disaster Microgrid Formation for Enhanced Distribution System Resilience

This paper proposes a deep reinforcement learning (DRL) based approach for post-disaster critical load restoration in active distribution systems to form microgrids through network reconfiguration to minimize critical load curtailments. Distribution networks are represented as graph networks, and optimal network configurations with microgrids are obtained by searching for the optimal spanning forest. The constraints to the research question being explored are the radial topology and power balance. Unlike existing analytical and population-based approaches, which necessitate the repetition of entire analyses and computation for each outage scenario to find the optimal spanning forest, the proposed approach, once properly trained, can quickly determine the optimal, or near-optimal, spanning forest even when outage scenarios change. When multiple lines fail in the system, the proposed approach forms microgrids with distributed energy resources in active distribution systems to reduce critical load curtailment. The proposed DRL-based model learns the action-value function using the REINFORCE algorithm, which is a model-free reinforcement learning technique based on stochastic policy gradients. A case study was conducted on a 33-node distribution test system, demonstrating the effectiveness of the proposed approach for post-disaster critical load restoration.

active distribution systems↗

Integrated Multi-Scale Data Analytics and Machine Learning for the Distribution Grid

We consider the field of machine learning and where it is both useful, and not useful, for the distribution grid and buildings interface. While analytics, in general, is a growing field of interest, and often seen as the golden goose in the burgeoning distribution grid industry, its application is often limited by communications infrastructure, or lack of a focused technical application. Overall, the linkage of analytics to purposeful application in the grid space has been limited. In this paper we consider the field of machine learning as a subset of analytical techniques, and discuss its ability and limitations to enable the future distribution grid. To that end, we also consider the potential for mixing distributed and centralized analytics and the pros and cons of these approaches. There is an exponentially expanding volume of measured data being generated on the distribution grid, which, with appropriate application of analytics, may be transformed into intelligible, actionable information that can be provided to the right actors - such as grid and building operators, at the appropriate time to enhance grid or building resilience, efficiency, and operations against various metrics or goals - such as total carbon reduction or other economic benefit to customers. While some basic analysis into these data streams can provide a wealth of information, computational and human boundaries on performing the analysis are becoming significant, with more data and multi-objective concerns. Efficient applications of analysis and the machine learning field are being considered in the loop. This paper describes benefits and limits of present machine-learning applications for use on the grid and presents a series of case studies that illustrate the potential benefits of developing advanced local multi-variate analytics machine-learning-based applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Matrix Completion for Improved Observability in Low-Voltage Distribution Grids

This paper considers the problem of recovering missing entries in a partially observed matrix from relatively few measurements (i.e., the so-called matrix completion problem) with the aim of increasing the presently limited observability of low-voltage distribution grids. To this end, the partially observed matrix is formed using scarce voltage magnitude measurements while accounting for their spatial information. Voltage readings are assumed to be collected from distribution utility sensors and/or geographically-distributed cable television network sensors located in immediate proximity to distribution grid nodes. A matrix completion approach built on the parameter-less singular value shrinkage technique is used to estimate voltage magnitudes at otherwise non-observable low-voltage nodes using a small number of single- or multiple-snapshot data. The effectiveness of the proposed approach is demonstrated using a U.S.-style distribution test system from the synthetic SMART- DS data set under very low- to moderate-observability conditions.

low-rank matrix completion↗

Distributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid

In microgrids, distributed load sharing plays an important role in maintaining the supply-demand balance of power. Because false data injection (FDI) is one of the crucial threats faced by future microgrids, the study of the impact of FDI on distributed load sharing is both of theoretical merit and practical value. Here, we consider the distributed load sharing problem of the microgrids operating in autonomous mode under FDI. Each bus is assumed to be equipped with an agent. Under a well-developed distributed load sharing protocol based on multiagent systems, we first construct an FDI attack model, where the attacker is capable of injecting false data into the bus agents. Finally, a utilization level is introduced for coordinating generators, and its variation is evaluated in the presence of FDI attacks with given injection strategies. The stable region of the microgrid is defined, and conditions are given to determine stability. In conclusion, theoretical results are validated on the Canadian urban distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverse Calculation of Burden Distribution Matrix Using B-spline Model Based PDF control in Blast Furnace Burden Charging Process

The inverse calculation of burden distribution matrix (BDM) is one of the most important challenges in the blast furnace operation in iron-making processes. In general, blast furnace consumes 65% of the total energy for the whole steel-making. Focusing on this practical challenge, this article proposes a new burden distribution spatial model in calculating burden charging process, and develops a B-spline approximation-based probability density function (PDF) control algorithm to assign the expected thickness distribution of burden layer and, thus, develops a new method for the required inverse calculation of BDM. First, a novel method for the thickness distribution of burden layer is given using B-spline model to produce an expected distribution shape subjected to a desired tracking within a specific spatial constraint. Then, according to the coexistence of continuous and bounded discrete variables in BDM, a novel hybrid optimization control method by combining integer programming and PDF tracking is further established for the effective inverse calculation of BDM. Finally, the proposed PDF-based iterative inverse calculation of BDM using B-spline models are tested using various data from industrial examples. Furthermore, the simulation results show that the proposed method is well suited to solve the BDM inverse calculation problem in practice.

42 ENGINEERING↗

Three-Phase Unbalanced Transient Dynamics and Powerflow for Modeling Distribution Systems With Synchronous Machines

Unlike transmission systems, distribution feeders in North America operate under unbalanced conditions at all times, and generally have a single strong voltage source. When a distribution feeder is connected to a strong substation source, the system is dynamically very stable, even for large transients. However if a distribution feeder, or part of the feeder, is separated from the substation and begins to operate as an islanded microgrid, transient dynamics become more of an issue. To assess the impact of transient dynamics at the distribution level, it is not appropriate to use traditional transmission solvers, which generally assume transposed lines and balanced loads. Full electromagnetic solvers capture a high level of detail, but it is difficult to model large systems because of the required detail. This paper proposes an electromechanical transient model of synchronous machine for distribution-level modeling and microgrids. This approach includes not only the machine model, but also its interface with an unbalanced network solver, and a powerflow method to solve unbalanced conditions without a strong reference bus. The presented method is validated against a full electromagnetic transient simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗