Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Trip Coils

A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sandia Electromagnetic Environment Simulator Facilities

Sandia National Laboratories’ (Sandia’s) Electrical Sciences Group (1350) provides a spectrum of solutions for electromagnetic (EM) environment effects on electrical systems to advance physical understanding including experiments, analytical and numerical model development leveraging first-principles physics, and high-performance computational modeling and simulation (M&S). The six departments in the Electrical Sciences Group provide analysis, design guidance, and experiments in support of nuclear weapons qualification in normal, abnormal, and hostile environments, as well as research and development for advanced electrical systems that can operate through these environments. This document is intended to provide a quick summary of Sandia’s EM experimental facilities, most of which provide unique national capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Suitability of Altair FEKO's Computational Electromagnetic Techniques for Tree Model Scattering and Penetration at Ku-band

Foliage penetration (FOPEN) radar at lower frequencies (VHF, UHF) is a well-studied area with many contributions. However, there is growing interest in using higher Ku-band frequencies (12-18 GHz) for FOPEN. Specifically, the reduced wavelength sizes provide some key saliencies for developing more optimized detection solutions. The disadvantage is that exploiting Ku-band for FOPEN is complicated because higher frequencies have pronounced scattering effects due to their smaller wavelengths. A methodology h as been developed to model and simulate FOPEN problems that characterize the phenomenology of Ku-band electromagnetic ( EM ) wave transmissions through moderate foliage. The details of this research (i.e. the realistic tree models, simulation setup and results) are documented in multiple reports. The main focus of this report is to describe the preliminary validation and verification of Altair FEKO, the computational EM (CEM) software used for this research, as well as present a simplified symmetrical tree model and an introductory CAD tree model.

42 ENGINEERING↗

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗

Three Dimensional Electromagnetic High Frequency Convex Cavity Scars

This report examines the localization of high frequency electromagnetic fields in general three-dimensional convex walled cavities along periodic paths between opposing sides of the cavity. The report examines the three-dimensional case where the mirrors at the end of the orbit have two different radii of curvature. The cases where these orbits lead to unstable localized modes are known as scars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Common Information Model for Electromagnetic Transients (CIM for EMT): CRADA 533 [Abstract only}

The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Three-Dimensional Electromagnetic High Frequency Concave Cavity Scars

This report examines the localization of high frequency electromagnetic fields in general three-dimensional cavities along periodic paths between opposing sides of the cavity. The focus is on the case where the mirrors at the ends of the orbit are concave and have two different radii of curvature. The cases where these orbits lead to unstable localized modes are known as scars. The ellipsoidal coordinate system is utilized in the construction of the scarred modes. The field at the interior foci is examined as well as trigonometric projections along the periodic scarred ray path.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice calculation of the pion electromagnetic form factor at high momentum transfer

The pion electromagnetic form factor, Fn, is a fundamentally important topic for our understanding of the hadron structure and the transition from perturbative to nonperturbative QCD. JLAB?s experiment E12-06-101 proposes to extend the high quality F? data to Q2=6.0 GeV2 as a part of JLAB?s 12 GeV upgrade. Being motivated by this, we present a lattice QCD calculation of Fn using the method of distillation and the variational approach which significantly reduce the excited state contamination. We study the shape of the vector form factor in the Q2 range from zero to a few GeV2 using Wilson quark formalism on our 203×128 anisotropic lattice configuration with light (up/down) and strange quarks in the sea and 400 MeV pion mass.

Chakraborty, Bipasha↗

A Systematic Approach for Estimating High-Altitude Electromagnetic Pulse Coupling onto Power Generation Facility Equipment

A systematic approach is presented to evaluate the effects of high-altitude electromagnetic pulse (HEMP) signals on the equipment located inside a power generation facility. The approach uses a combination of practical measurement and simulation efforts to characterize the radio wave propagation behavior and the device immunity profile. Of particular interest in this work was estimating the vulnerability level of equipment that is connected to long cables. As an example application, a detailed study was conducted for one common class of facility equipment, and its frequency- and time-domain HEMP coupling properties were investigated as a function of terminal loading condition and cable attachment configuration. Overall, the proposed method can be generalized and applied to other electronic components and systems found in the facility environment.

42 ENGINEERING↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Nuclear Research using the Electromagnetic Probe

This is the final progress report for the project titled "Nuclear Research Using the Electromagnetic Probe." Our primary objective was to gain a deeper understanding of the internal structure of protons and neutrons, which are the fundamental constituents of nucleons and nuclei. These building blocks, composed of quarks and gluons known as "partons," were the focal point of our investigation. We delved into the intrinsic properties of nucleons, including their mass, charge, and spin, within the framework of Quantum Chromodynamics (QCD), a theory describing the intricate interactions, often referred to as color interactions, between the constituents of nucleons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic Inhomogeneous-Energy-Density-Driven Instability in the UCLA Large Plasma Device (EM-IEDDI in LAPD) (Final Technical Report)

Using the Large Plasma Device (LAPD), the electromagnetic signatures associated with the inhomogeneous-energy-density-driven (IEDD) instability were targeted for documentation in a lab experiment. Exploitable features of LAPD are the extreme-length, high-beta, low-collisionality, and excellent reproducibility. The signatures of interest were mode amplitude, mode structure, frequency spectrum, phase velocity, and excitation threshold. The abrupt inhomogeneity at the interface between two coaxial plasma columns, that have disparate space potential values, were expected to generate a strong, localized, transverse, dc electric field and form a strong ExB-flow inhomogeneity that was expected to trigger broadband, intermediate-frequency waves that propagate many gyroradii beyond the interfacial source region. WVU was unable to destabilize the IEDDI mode in LAPD. Experimental limitation of three different parameters conspire to prevent IEDDI-favorable conditions even though Alfven-favorable conditions are met. Electron-neutral collision frequency is too high, Structuring of the radial profile of the radial electric field is negligible and the control of that structure is minimal, and the Magnetic field is too large for some purposes and too small for other purposes. WVU designed a new antenna and relied on externally-driving the IEDDI (instead of spontaneous destabilization). The antenna operation failed for unforeseen reasons and lack of electrician time and availability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Workloads of a Linear Electromagnetic Code for Load Balancing Matrix Assembly

This report presents our work to model the workloads of a linear electromagnetic application based on the method of moments in the frequency domain to effectively load balance the matrix assembly. This application is particularly challenging to load balance due to its lack of persistent iterative behavior, its operation under tight memory constraint (where the matrix may fill 80% of memory on each node), and the algorithmic complexity of the computational method. This report describes the first step in our work to apply an inspector-executor approach for load balancing workloads where key parameters are exposed during the inspector phase and a pre-trained model is applied to predict relative task weights for the load balancer.

97 MATHEMATICS AND COMPUTING↗

Magnetic Properties of Cables with Meandering Wires through a Multipole-based Cable Braid Electromagnetic Penetration Model

In this paper, we employ our first principles multipole-based cable braid electromagnetic penetration model to evaluate the transfer inductance of cables exhibiting meandering wires. We concentrate on a cable structure with two wires, and consider the dependence on the transfer inductance as a function of braid angle and amplitude of the meandering. We compare the results from the first principles model to analytical estimations, confirming the accuracy and correctness of our model. In turn, this makes the multipole-based model readily available for the modeling of realistic cable geometries by accounting for the full dependence on the actual cable geometry.

36 MATERIALS SCIENCE↗

Electromagnetic Radioisotope Separator for Methods Development, Testing, and Training

The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.

07 ISOTOPE AND RADIATION SOURCES↗