Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Analysis Methods for Milky Way Dark Matter Halo Detection

We present methods for the analysis of dark matter annihilation in the smooth halo of the Milky Way galaxy. We model the diffuse gamma-ray background using GALPROP, and model the halo using an NFW profile and the gamma-ray spectrum for WIMP pair annihilation. We plan to combine these models with the point source catalog and a simple model for the extragalactic gamma ray background. Using the downhill simplex method to converge on the maximum likelihood value, we can vary key parameters in these models and fit them to the gamma-ray data. Through the use of the Markov Chain Monte Carlo (MCMC) method we can then map out the likelihood as a function of the model parameters to estimate the correlated errors on these parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DENSITY-FUNCTIONAL STUDY OF THE U-ZR SYSTEM

Density-functional formalism is applied to study the phase equilibria in the U-Zr system. The obtained ground-state properties of the {gamma} (bcc) and {delta} (C32) phases are in good agreement with experimental data. The decomposition curve for the {gamma}-based U-Zr solutions is calculated. Our calculations confirm that experimentally observed 'partial' ordering of the alloy components in the {delta}-UZr{sub 2} (AlB{sub 2}) phase, in which Zr atoms occupy the 'Al' position and the two 'B' sites are randomly shared by the U and Zr atoms, is the most energetically favorable within the C32 structure. We argue that stabilization of the {delta}-UZr{sub 2} phase relative to the {alpha}-Zr (hcp) structure is due to an increase of the Zr d-band occupancy that occurs when U is alloyed with Zr. A comparison with stabilization of the {omega}-phase (also C32) in Zr under compression is made.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains

Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brain were delimited and a treatment plan was generated. A single isocenter treatment plan delivering ≥100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors’ results showed that 90% of the target volume received 100 ± 8 Gy and the maximum of deposited dose was 125 ± 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors’ results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife.

60 APPLIED LIFE SCIENCES↗

Cross-species analysis of FcγRIIa/b (CD32a/b) polymorphisms at position 131: structural and functional insights into the mechanism of IgG- mediated phagocytosis in human and macaque

Introduction Antibodies play a critical role in immunity in part by mediating clearance of pathogens and infected cells by antibody-dependent cellular phagocytosis (ADCP) through engagement of Fc gamma receptors (FcγRs) on innate immune cells. Among these, FcγRIIa (CD32a) is a key activating receptor expressed on macrophages, dendritic cells, and other antigen-presenting cells. Its affinity for IgG and ability to mediate ADCP is influenced by allelic polymorphisms. In humans, a single amino acid polymorphism at position 131, where histidine (H) is substituted with arginine (R), leads to decreased IgG1 and IgG2 subclass binding affinity and, consequently, lower efficiency of phagocytic responses. Rhesus macaques ( Macaca mulatta ), which are widely used as nonhuman primate models, exhibit a similar polymorphism at position 131 of FcγRIIa, but with arginine replaced by proline (P). Here, we investigated structure-function relationships associated with the FcγRIIa polymorphism at position 131 in both species, specifically with respect to IgG1 and IgG2. Methods We determined the structures of complexes formed by each variant with IgG1 Fc and those formed by the higher affinity variant with IgG2 Fc for both species by x-ray crystallography and linked these structures to affinity and activity using SPR and an ADCP assay. We also determined the structure of human inhibitory FcγRIIb (CD32b) in complex with IgG1 Fc by x-ray crystallography. Results Through analysis of these structures, our studies reveal that FcγRIIa engagement is minimally influenced by Fc glycan composition, distinguishing it from FcγRIIIa whose affinity is strongly influenced by glycan-composition. Comparative structures of human and macaque FcγRIIa variants demonstrate species- and allele-specific differences in Fc binding, but our functional assays showed only minimal allele-specific effects in humans. In contrast, allele-specific effects in macaques were highly significant; the macaque P 131 variant showing uniformly reduced IgG affinity. Conclusion These insights highlight fundamental interspecies and allelic distinctions that are critical for interpreting FcγRIIa-mediated effector functions in macaque models and for optimizing translational antibody and vaccine design.

Tolbert, William D.↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled High-Resolution Gamma Spectrometry Systems Final Report

Under a 2006 agreement between the Department of Energy (DOE) of the United States of America and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) of France, the National Nuclear Security Administration (NNSA) within DOE and IRSN initiated a collaboration to improve isotopic identification and analysis of nuclear material [i.e., plutonium (Pu) and uranium (U)]. The specific aim of the collaborative project was to develop new versions of two types of isotopic identification and analysis software: (1) the fixed-energy response-function analysis for multiple energies (FRAM) codes and (2) multi-group analysis (MGA) codes. The project is entitled Action Sheet 4 – Cooperation on Improved Isotopic Identification and Analysis Software for Portable, Electrically Cooled, High-Resolution Gamma Spectrometry Systems (Action Sheet 4). FRAM and MGA/U235HI are software codes used to analyze isotopic ratios of U and Pu. FRAM is an application that uses parameter sets for the analysis of U or Pu. MGA and U235HI are two separate applications that analyze Pu or U, respectively. They have traditionally been used by safeguards practitioners to analyze gamma spectra acquired with high-resolution gamma spectrometry (HRGS) systems that are cooled by liquid nitrogen. However, it was discovered that these analysis programs were not as accurate when used on spectra acquired with a newer generation of more portable, electrically cooled HRGS (ECHRGS) systems. In response to this need, DOE/NNSA and IRSN collaborated to update the FRAM and U235HI codes to improve their performance with newer ECHRGS systems. Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) performed this work for DOE/NNSA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Short-Term Effects of Low-LET Radiation on the Endothelial Barrier: Uncoupling of PECAM-1 and the Production of Endothelial Microparticles

A significant target for radiation-induced effects is the microvascular system, which is critical to healthy tissue function and its pathology is linked to disrupted endothelial barrier function. Low-linear energy transfer (LET) ionizing radiation is a source of noncancer pathologies in humans and little is known about the early events that could initiate subsequent diseases. But, it is well known that gamma radiation causes a very early disruption of the endothelial barrier at doses below those required for cytotoxic effects. After irradiation of human umbilical vein endothelial cells (HUVECs) to doses as low as 2 Gy, transendothelial electrical resistance (TEER) is transiently reduced at 3 h, and the platelet-derived endothothelial cell adhesion molecule (PECAM-1 or CD31) is uncoupled from the cells along with the release of endothelial microparticles (EMPs). In this study, we measured TEER reduction as an indicator of barrier function loss, and specifically examined the shedding of EMPs from human endothelial barrier models after a variety of low-LET irradiations, including photons and charged particles. Our findings showed two TEER responses, dependent on radiation type and environmental conditions. The first response was diminishing oscillations of TEER, which occurred during the first 10 h postirradiation. This response occurred after a 5 Gy proton or helium-ion (1 GeV/n) dose in addition to a 5 Gy gamma or X radiation dose. This occurred only in the presence of multiple growth factors and did not show a dose response, nor was it associated with EMP release. The second response was a single acute drop in TEER at 3 h after photon irradiation. Dose response was observed and was associated with the shedding of EMPs in 2D barrier cultures and in 3D vessel models. In this case, helium-ion and proton irradiations did not induce a drop in TEER or shedding of EMPs. The photon radiation effects was observed both in serum-free media and in the presence of multiple growth factors, indicating that it occurs under a range of environmental conditions. Finally, our results show an acute response of the human endothelial barrier that is relevant to photon irradiation. Significantly, it involves the release of EMPs, which have recently attracted attention due to their emerging clinical importance.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid and kinetic parameters near the plasma-sheath boundary for finite Debye lengths

In a recent paper by Kuhn et al. [Phys. Plasmas 13, 013503 (2006)], it has been demonstrated that in a plasma, the polytropic coefficient {gamma} is a spatially varying quantity rather than a global constant as usually assumed in fluid theory. Assuming cold ion sources and using the asymptotic two-scale approximation (in which the ratio of the Debye length over the characteristic presheath length, {epsilon}, is set to zero), it was found that the {gamma} profile exhibits a sharp peak (with values roughly between 6 and 8) at the plasma-sheath boundary. In the present paper, it is shown that in a finite {epsilon} approach, this sharp peak is smoothed to a regular maximum, which for increasing {epsilon} (e.g., decreasing plasma density) decreases and finally disappears. In any case, assumptions like {gamma}=1 and/or {gamma}=3, which are customarily encountered in the context of fluid approaches, are disproved. Although the present results were obtained for collisionless plasmas, it is reasonable to assume that the behavior uncovered holds qualitatively for any plasma with cold ion sources. In addition to calculating time-independent theoretical solutions by means of an analytic-numerical approach, we primarily employ particle-in-cell (PIC) computer simulations, which intrinsically represent a time-dependent approach. It is confirmed that, although extreme care is required to separate physical from numerical effects, the PIC simulation method is a highly suitable tool also for future investigations of more demanding physical scenarios assuming, e.g., warm ion sources and other more complex aspects that cannot be treated realistically by analytic-numerical means alone. In addition, the extension from time-independent analytic-numerical calculation to time-dependent simulation permits us also to investigate the effect of collective plasma oscillations on the ion velocity distribution function (VDF). Although the ion VDFs obtained in our PIC simulations visibly differ in some details from the time-independent theoretical ones, the related ion-temperature and {gamma} profiles turn out to fit their theoretical counterparts very well over significant parameter ranges. Hence, the two methods may to some extent be applied as alternative ones in future investigations on the plasma-sheath transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on the light pseudoscalar meson distribution amplitudes from their meson-photon transition form factors

The meson-photon transition form factors {gamma}{gamma}*{yields}P (P stands for {pi}, {eta} and {eta}') provide strong constraints on the distribution amplitudes of the pseudoscalar mesons. In this paper, these transition form factors are calculated under the light-cone perturbative QCD approach, in which both the valence and nonvalence quarks' contributions have been taken into consideration. To be consistent, a unified wave function model is adopted to analyze these form factors. It is shown that with the proper charm component f{sub {eta}}'{sup c}{approx}-30 MeV and a moderate DA with B{approx}0.30, the experimental data on Q{sup 2}F{sub {eta}{gamma}}(Q{sup 2}) and Q{sup 2}F{sub {eta}'{gamma}}(Q{sup 2}) in the whole Q{sup 2} region can be explained simultaneously. Furthermore, a detailed discussion on the form factors' uncertainties caused by the constituent quark masses m{sub q} and m{sub s}, the parameter B, the mixing angle {phi}, and f{sub {eta}'}{sup c} are presented. It is found that, by adjusting these parameters within their reasonable regions, one can improve the form factor to a certain degree but cannot solve the puzzle for Q{sup 2}F{sub {pi}{gamma}}(Q{sup 2}), especially to explain the behavior of the {pi}-{gamma} form factor within the whole Q{sup 2} region consistently. We hope further experimental data on these form factors in the large Q{sup 2} region can clarify the present situation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 2010 Very High Energy Gamma-Ray Flare and 10 Years of Multi-Wavelength Observations of M87

The giant radio galaxy M87 with its proximity (16 Mpc), famous jet, and very massive black hole ((3-6) X 10(exp 9) Solar Mass) provides a unique opportunity to investigate the origin of very high energy (VHE; E>100 GeV) gamma-ray emission generated in relativistic outflows and the surroundings of super-massive black holes. M87 has been established as a VHE gamma -ray emitter since 2006. The VHE gamma -ray emission displays strong variability on timescales as short as a day. In this paper, results from a joint VHE monitoring campaign on M87 by the MAGIC and VERITAS instruments in 2010 are reported. During the campaign, a flare at VHE was detected. triggering further observations at VHE (H.E.S.S.), X-rays (Chandra), and radio (43 GHz VLBA). The excellent sampling of the VHE gamma-ray light curve enables one to derive a precise temporal characterization of the flare: the single, isolated flare is well described by a two-sided exponential function with significantly different flux rise and decay times of rise tau ((sup rise sub d) = (1:69 +/- 0:30) days and tau(sup decay sub d = (0:611 +/- 0:080) days, respectively. While the overall variability pattern of the 2010 flare appears somewhat different from that of previous VHE flares in 2005 and 2008, they share very similar timescales (approx day), peak fluxes (Phi (sub > 0:35 TeV) approx. equals (1 - 3) X 10(exp -11) ph / square cm/s), and VHE spectra. 43 GHz VLBA radio observations of the inner jet regions indicate no enhanced flux in 2010 in contrast to observations in 2008, where an increase of the radio flux of the innermost core regions coincided with a VHE flare. On the other hand, Chandra X-ray observations taken approx 3 days after the peak of the VHE gamma -ray emission reveal an enhanced flux from the core (flux increased by factor approx 2; variability timescale < 2 days). The long-term (2001-2010) multi-wavelength (MWL) light curve of M87, spanning from radio to VHE and including data from HST, LT, VLA and EVN, is used to further investigate the origin of the VHE gamma -ray emission. No unique, common MWL signature of the three VHE flares has been identified. In the outer kpc jet region, in particular in HST-1, no enhanced MWL activity was detected in 2008 and 2010, disfavoring it as the origin of the VHE flares during these years. Shortly after two of the three flares (2008 and 2010), the X-ray core was observed to be at a higher flux level than its characteristic range (determined from more than 60 monitoring observations: 2002-2009). In 2005, the strong flux dominance of HST-1 could have suppressed the detection of such a feature. Published models for VHE gamma -ray emission from M87 are reviewed in the light of the new data.

Abramowski, A.↗

Nuclear Structure of {sup 8}B Studied by Proton Resonance Scatterings on {sup 7}Be

A new measurement of the proton resonance scattering on {sup 7}Be was performed up to the excitation energy of 6.8 MeV using the low-energy RI beam facility CRIB (CNS Radioactive Ion Beam separator) at the Center for Nuclear Study (CNS) of the University of Tokyo. The excitation function of {sup 8}B above 3.5 MeV was successfully measured for the first time, providing important information about the reaction rate of {sup 7}Be(p,{gamma}){sup 8}B, which is the key reaction in the solar {sup 8}B neutrino production. For more intensive experimental studies with RI beams, the development of a cryogenic gas target system is ongoing at CNS. In this paper a preliminary result of the {sup 7}Be experiment and the present status of the development of the target system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Emission of GRB 121217A from Gamma-Rays to the Near-Infrared

The mechanism that causes the prompt-emission episode of gamma-ray bursts (GRBs) is still widely debated despite there being thousands of prompt detections. The favoured internal shock model relates this emission to synchrotron radiation. However, it does not always explain the spectral indices of the shape of the spectrum, which is often fit with empirical functions, such as the Band function. Multi-wavelength observations are therefore required to help investigate the possible underlying mechanisms that causes the prompt emission. We present GRB 121217A, for which we were able to observe its near-infrared (NIR) emission during a secondary prompt-emission episode with the Gamma-Ray burst Optical Near-infrared Detector (GROND) in combination with the Swift and Fermi satellites, which cover an energy range of 5 orders of magnitude (10(exp −3) keV to 100 keV). We determine a photometric redshift of z = 3.1 +/- 0.1 with a line-of-sight with little or no extinction (AV approx. 0 mag) utilising the optical/NIR SED. From the afterglow, we determine a bulk Lorentz factor of Gamma(sub 0) approx. 250 and an emission radius of R < 1018 cm. The prompt-emission broadband spectral energy distribution is well fit with a broken power law with beta1 = −0.3 +/- 0.1 and beta2 = 0.6 +/- 0.1 that has a break at E = 6.6 +/- 0.9 keV, which can be interpreted as the maximum injection frequency. Self-absorption by the electron population below energies of Ea < 6 keV suggest a magnetic field strength of B approx. 10(exp 5) G. However, all the best fit models underpredict the flux observed in the NIR wavelengths, which also only rebrightens by a factor of approx. 2 during the second prompt emission episode, in stark contrast to the X-ray emission, which rebrightens by a factor of approx. 100. This suggests an afterglow component is dominating the emission. We present GRB 121217A, one of the few GRBs that has multi-wavelength observations of the prompt-emission period and shows that it can be understood with a synchrotron radiation model. However, due to the complexity of the GRB's emission, other mechanisms that result in Band-like spectra cannot be ruled out.

prompt↗

DIFFUSE PeV NEUTRINOS FROM GAMMA-RAY BURSTS

The IceCube Collaboration recently reported the potential detection of two cascade neutrino events in the energy range 1-10 PeV. We study the possibility that these PeV neutrinos are produced by gamma-ray bursts (GRBs), paying special attention to the contribution by untriggered GRBs that elude detection due to their low photon flux. Based on the luminosity function, rate distribution with redshift and spectral properties of GRBs, we generate, using a Monte Carlo simulation, a GRB sample that reproduces the observed fluence distribution of Fermi/GBM GRBs and an accompanying sample of untriggered GRBs simultaneously. The neutrino flux of every individual GRB is calculated in the standard internal shock scenario, so that the accumulative flux of the whole samples can be obtained. We find that the neutrino flux in PeV energies produced by untriggered GRBs is about two times higher than that produced by the triggered ones. Considering the existing IceCube limit on the neutrino flux of triggered GRBs, we find that the total flux of triggered and untriggered GRBs can reach at most a level of {approx}10{sup -9} GeV cm{sup -2} s{sup -1} sr{sup -1}, which is insufficient to account for the reported two PeV neutrinos. Possible contributions to diffuse neutrinos by low-luminosity GRBs and the earliest population of GRBs are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Microstructural evolution of a MCrAlY coating upon isothermal annealing

The microstructural evolution of a freestanding {gamma} + {beta} NiCoCrAlY coating, as deposited by electron beam physical vapor deposition, was studied following isothermal annealing at 1373 K. Electron backscatter diffraction (EBSD) was used to characterize the crystallographic texture, grain and phase boundary population and the size and distribution of the grains in the coating as a function of annealing time. The as-deposited coating consisted of small equiaxed grains near the bottom, and large columnar grains near the surface of the coating. A phase separation process inside the columnar grains resulted in a local microstructure consisting of a periodic arrangement of {gamma} and {beta} lamellae, linked to each other according to the Kurdjumov-Sachs orientation relationship. Upon annealing, equiaxed-shaped grains formed within the coating at the expense of the columnar grains. The formation of the equiaxed grains corresponded with an increase of the total interface length per unit area in the coating. Upon prolonged annealing, growth of the equiaxed grains occurred according to a power law with a time exponent n of 2.

36 MATERIALS SCIENCE↗

X-ray and gamma-ray line production by nonthermal ions

X-ray production was calculated at approximately 6.8 keV by the 2p to 1s transition in fast hydrogen- and helium-like iron ions, following both electron capture to excited levels and collisional excitation. A refinement of the OBK approximation was used to obtain an improved charge exchange cross section. This, and the corresponding ionization cross section were used to determine equilibrium charge fractions for iron ions as functions of their energy. The effective X-ray line production cross section was found to be sharply peaked in energy at about 8 to 12 MeV/amu. Because fast ions of similar energies can also excite nuclear levels, the ratio of selected strong gamma ray line emissivities to the X-ray line emissivity was also calculated. Limits set by this method on the intensity of gamma ray line emission from the galactic center and the radio galaxy Centaurus A are generally lower than those reported in the literature.

Bussard, R. W.↗

Uranium Holdup Monitoring with Compton Imaging as Function of Depth and Mass

Material Control and Accountability (MC&A) programs track masses of materials flowing through production processes, where some material remains in process equipment as holdup. Quantification of these masses using gamma emissions typically involves usage of a well characterized radiation detector and assumptions of geometric configuration to constrain detection efficiencies, where the Generalized Geometry Holdup (GGH) method is often used. Uncertainties on the order of ±50% are observed, where the difficulties arise based on the asymmetric and gradient distributions of material that do not fall within the bounds of GGH. Gamma imagers provide a possible means to improve this geometric knowledge. This work describes the process used in creating a series of mass standards to aid the development of imaging algorithms for quantification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MONTE CARLO SIMULATIONS OF THE PHOTOSPHERIC EMISSION IN GAMMA-RAY BURSTS

We studied the decoupling of photons from ultra-relativistic spherically symmetric outflows expanding with constant velocity by means of Monte Carlo simulations. For outflows with finite widths we confirm the existence of two regimes: photon-thick and photon-thin, introduced recently by Ruffini et al. (RSV). The probability density function of the last scattering of photons is shown to be very different in these two cases. We also obtained spectra as well as light curves. In the photon-thick case, the time-integrated spectrum is much broader than the Planck function and its shape is well described by the fuzzy photosphere approximation introduced by RSV. In the photon-thin case, we confirm the crucial role of photon diffusion, hence the probability density of decoupling has a maximum near the diffusion radius well below the photosphere. The time-integrated spectrum of the photon-thin case has a Band shape that is produced when the outflow is optically thick and its peak is formed at the diffusion radius.

79 ASTRONOMY AND ASTROPHYSICS↗