Next-Generation Performance-Based Regulation: Emphasizing Utility Performance to Unleash Power Sector Innovation

Performance-based regulation (PBR) enables regulators to reform hundred-year-old regulatory structures to unleash innovations within 21st century power systems. An old regulatory paradigm built to ensure safe and reliable electricity at reasonable prices from capital-intensive electricity monopolies is now adjusting to a new century of disruptive technological advances that change the way utilities make money and what value customers expect from their own electricity company. Advanced technologies are driving change in power sectors around the globe. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. These emerging technology drivers include renewable generation, distributed energy resources such as distributed generation and energy storage, demand-side management measures such as demand-response, electric vehicles, and smart grid technologies and energy efficiency (EE). PBR enables regulators to recognize the value that electric utilities bring to customers by enabling these advanced technologies and integrating smart solutions into the utility grid and utility operations. These changes in the electric energy system and customer capacities means that there is an increasing interest in motivating regulated entities in other areas beyond traditional cost-of-service performance regulation. This report addresses best practices gleaned from more than two decades of PBR in practice, and analyzes how those best practices and lessons can be used to design innovative PBR programs. Readers looking for an introduction to PBR may want to focus on Chapters 1-5. Chapters 6 and 7 contain more detail for those interested in the intricate workings of PBR or particularly innovative PBR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Unleash Values From Grid-Edge Flexibility: An Overview, Experience, and Vision for Leveraging Grid-Edge Distributed Energy Resources to Improve Grid Operations

The power system landscape is presently undergoing a dramatic change with the rapid integration of numerous distributed energy resources (DERs) at the grid edge. Broadly, we consider grid-edge DERs as any electricity source, storage, and demand response program connected to the medium-to-low-voltage distribution system.

distributed energy resource↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Automated electrical demand peak leveling in a manufacturing facility with short term energy storage for smart grid participation

Demand side management of energy is a vital function in the smart grid that allows for greater integration of renewable energy resources, and is facilitated with economic incentives in energy and demand pricing schedules. Manufacturing systems can take advantage of these incentives to reduce their energy costs through active energy management. This paper is a simulation analysis on the implementation of a novel algorithm that levelizes the maximum power load of an industrial bakery that operates under an on-peak demand price structure. The algorithm takes advantage of an untapped thermal energy storage resource in the facility, a chilled glycol buffer tank, to level the short intra-day power oscillations that the facility experiences. One of the key advantages of the algorithm is that it does not require precise demand forecasting or complex control algorithms, such as model predictive control. Even with substantial error in peak power estimates (5%), the algorithm is expected to result in at least a 2% peak reduction. Under ideal prediction, the algorithm reduces the on-peak facility power maximum by 7.3% of the possible 9.0% reduction the storage can provide. Further, the algorithm uses very few facility specific inputs, and can readily be adapted for any facility with short intra-day oscillatory power profiles and untapped storage capacity. The key insight of the paper is the employment of a novel algorithm to leverage untapped energy storage in manufacturing facilities to transform them into smart grid participants with no major capital investment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Evolution of the Internet Community and the"Yet-to-Evolve" Smart Grid Community: Parallels and Lessons-to-be-Learned

The Smart Grid envisions a transformed US power distribution grid that enables communicating devices, under human supervision, to moderate loads and increase overall system stability and security. This vision explicitly promotes increased participation from a community that, in the past, has had little involvement in power grid operations -the consumer. The potential size of this new community and its member's extensive experience with the public Internet prompts an analysis of the evolution and current state of the Internet as a predictor for best practices in the architectural design of certain portions of the Smart Grid network. Although still evolving, the vision of the Smart Grid is that of a community of communicating and cooperating energy related devices that can be directed to route power and modulate loads in pursuit of an integrated, efficient and secure electrical power grid. The remaking of the present power grid into the Smart Grid is considered as fundamentally transformative as previous developments such as modern computing technology and high bandwidth data communications. However, unlike these earlier developments, which relied on the discovery of critical new technologies (e.g. the transistor or optical fiber transmission lines), the technologies required for the Smart Grid currently exist and, in many cases, are already widely deployed. In contrast to other examples of technical transformations, the path (and success) of the Smart Grid will be determined not by its technology, but by its system architecture. Fortunately, we have a recent example of a transformative force of similar scope that shares a fundamental dependence on our existing communications infrastructure - namely, the Internet. We will explore several ways in which the scale of the Internet and expectations of its users have shaped the present Internet environment. As the presence of consumers within the Smart Grid increases, some experiences from the early growth of the Internet are expected to be informative and pertinent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Interactive Efficient Buildings Fact Sheet

The U.S. Department of Energy’s Building Technologies Office (BTO) envisions a future in which buildings operate dynamically with the grid to make electricity more affordable and integrate distributed energy resources while meeting the needs of building occupants.

Grid modernization, energy efficiency, utilities, ↗

Final Technical Report: Results of Phase 1

Arizona Public Service Company (APS) expects that by 2027, renewable energy will account for 6,590 GWh in energy consumption by its customers. While much of this future energy will come from large centrally-located power plants, distributed renewable energy, sited at the point of end-use will also play an important role in meeting the needs of APS customers and is expected to provide 1,734 GWh. With increasing penetration of residential and commercial photovoltaic (PV) systems at the point of end-use, PV power generation not only offsets the load, but could also cause significant shifts in power flow patterns through the distribution system, and could possibly cause reversal of flow through some branches of a distribution circuit. Significant changes to power flow introduced into existing distribution systems due to the increased amount of PV systems may cause operational issues, including over-voltage on the distribution feeder (loss of voltage regulation) and incorrect operation of control equipment, which may lead to an increase in the number of operations and related equipment wear that could affect equipment reliability and customer power quality. Additionally, connecting generation resources to a distribution feeder can introduce additional sources of short-circuit current to the distribution system. This could potentially result in increased short-circuit currents, potentially reaching damaging levels, causing protection desensitization and a potential loss of protection coordination. These effects may be further compounded by variability of PV production due to shading by clouds. The effects of these phenomena in distributed PV applications are not well understood, and there is a great need to characterize this variability. This project will contribute to understanding the effects of high-penetration solar electricity on the design and operation of distribution systems by demonstrating how a high penetration of PV systems affects grid operations of a working, utility distribution feeder. To address the technical challenges related to the integration of distributed PV when PV penetration levels reach or exceed 30% of the total load, technologies and methods to ensure the stable and safe operation of the feeder will be evaluated. Lessons learned will enable APS to improve the framework for future PV integration on its system and may also aid other utilities across the United States energy sector in accelerating the adoption of distributed photovoltaic generation.

14 SOLAR ENERGY↗

Integrated State Estimation and Contingency Analysis Software Implementation using High Performance Computing Techniques

Power system simulation tools are traditionally developed in sequential mode and codes are optimized for single core computing only. However, the increasing complexity in the power grid models requires more intensive computation. The traditional simulation tools will soon not be able to meet the grid operation requirements. Therefore, power system simulation tools need to evolve accordingly to provide faster and better results for grid operations. This paper presents an integrated state estimation and contingency analysis software implementation using high performance computing techniques. The software is able to solve large size state estimation problems within one second and achieve a near-linear speedup of 9,800 with 10,000 cores for contingency analysis application. The performance evaluation is presented to show its effectiveness.

Chen, Yousu↗

Comment on"Air Emissions Due to Wind and Solar Power" and Supporting Information

Katzenstein and Apt investigate the important question of pollution emission reduction benefits from variable generation resources such as wind and solar. Their methodology, which couples an individual variable generator to a dedicated gas plant to produce a flat block of power is, however, inappropriate. For CO{sub 2}, the authors conclude that variable generators 'achieve {approx} 80% of the emission reductions expected if the power fluctuations caused no additional emissions.' They find even lower NO{sub x} emission reduction benefits with steam-injected gas turbines and a 2-4 times net increase in NO{sub x} emissions for systems with dry NO{sub x} control unless the ratio of energy from natural gas to variable plants is greater than 2:1. A more appropriate methodology, however, would find a significantly lower degradation of the emissions benefit than suggested by Katzenstein and Apt. As has been known for many years, models of large power system operations must take into account variable demand and the unit commitment and economic dispatch functions that are practiced every day by system operators. It is also well-known that every change in wind or solar power output does not need to be countered by an equal and opposite change in a dispatchable resource. The authors recognize that several of their assumptions to the contrary are incorrect and that their estimates therefore provide at best an upper bound to the emissions degradation caused by fluctuating output. Yet they still present the strong conclusion: 'Carbon dioxide emissions reductions are likely to be 75-80% of those presently assumed by policy makers. We have shown that the conventional method used to calculate emissions is inaccurate, particularly for NO{sub x} emissions.' The inherently problematic methodology used by the authors makes such strong conclusions suspect. Specifically, assuming that each variable plant requires a dedicated natural gas backup plant to create a flat block of power ignores the benefits of diversity. In real power systems, operators are required to balance only the net variations of all loads and all generators, not the output of individual loads or generators; doing otherwise would ensure an enormous amount of unnecessary investment and operating costs. As a result, detailed studies that aggregate the variability of all loads and generators to the system level find that the amount of operating reserves required to reliably integrate variable resources into the grid are on the order of 10% of the nameplate capacity of the variable generators, even when upto25%of gross demand is being met by variable generation. The authors implicit assumption that incremental operating reserves must be 100% of the nameplate capacity of the variable generation, and be available at all times to directly counter that variability, excludes the option of decommitting conventional units when the load net of variable generation is low. In real power systems, generation response to wind variation can typically be met by a combination of committed units, each operating at a relatively efficient point of their fuel curves. In the Supporting Information, we conceptually demonstrate that the CO{sub 2} and NO{sub x} efficiency penalty found by the authors can be significantly reduced by considering the unit commitment decision with just five plants. Real systems often have tens to hundreds of plants that can be committed and decommitted over various time frames. Ignoring the flexibility of the unit commitment decision therefore leads to unsupportable results. Anumber of analyses of the fuel savings and CO{sub 2} emission benefits of variable generation have considered realistic operating reserve requirements and unit commitment decisions in models that include the reduction in part load efficiency of conventional plants. The efficiency penalty due to the variability of wind in four studies considered by Gross et al. is negligible to 7%, for up to a 20% wind penetration level. In short, for moderate wind penetration levels, 'there is no evidence available to date to suggest that in aggregate efficiency reductions due to load following amount to more than a few percentage points'. As such, other studies using a more appropriate methodology have found a much smaller CO{sub 2} penalty from variability than found by Katzenstein and Apt. Less information is available on the NO{sub x} emission penalty. Results from recent state-of-the-art integration studies in the United States indicate at the very least clear NO{sub x} emission reduction benefits from variable generation. NO{sub x} reductions estimated in these studies are discussed in more detail in the Supporting Information. Denny and O'Malley similarly find NO{sub x} reduction benefits when forecasting is used in the unit commitment decision.

14 SOLAR ENERGY↗

Large Load Integration - Task List and Overview

Large Load Integration Tasks: Task 1 – Workshops Support stakeholder engagement across industry to promote collaboration and identify solutions to challenges that will guide other work Task 2 – Ancillary Services Characterize different types of large loads to assess under what conditions they may be utilized to provide grid stability services Task 3 – Communications Explore the cybersecurity and communications infrastructure required to enable large loads to interface with grid operations to provide ancillary services Task 4 – Nuclear Integration Explore risks and methods for supporting large load energy needs with SMRs and incorporating them into the wider power system Task 5 – Decision Support and TA Provide support to stakeholders through the creation of planning tools and direct technical assistance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

A Hydrogen Load Modeling Method for Integrated Hydrogen Energy System Planning

The integrated hydrogen energy system incorporates hydrogen energy into the power grid, which has been recognized as a promising option for reaching a 100% renewable electricity supply. It can make a profit because the hydrogen produced can be sold as fuel or used to generate electricity for grid services. In this paper, we develop a planning model for the integrated hydrogen energy system that considers the uncertainty of the load demand, the renewable energy generation, and the market prices. To calculate the hydrogen load, we simulate the refueling operations at a hydrogen fueling station over the course of one day and generate representative load profiles with K-means clustering. Moreover, the long-term profitability of the integrated system under both current and future conditions is validated in 10-year planning results.

grid service↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.