Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Plasmonic tuning of gold doped thin films for layers of photovoltaic devices

In order to increase the absorption rates in solar cells, increasing research activities on the plasmonic nanostructures are followed carefully. The plasmonic nanoparticles provides an important enhancement in the trapping of photons in the active layer of the solar cells by means of interaction between incident light and plasmonic nanoparticles. In order to obtain this approach, under of 5×10{sup −4} mbar and 1×10{sup −2} mbar ambient argon gas pressure, gold thin film was deposited on the silicon substrate by applying PLD system. The morphology of thin films obtained was investigated by AFM and SEM considering the effect of Ar gas pressure on the plasma plume. SPR peaks for Au nanoparticles deposited under 5×10{sup −4} mbar and 1×10{sup −2} mbar Ar gas pressure were observed at 756 nm and 658 nm wavelengths respectively. It has been stated that the SPR peak in the infrared is depend on the near field interaction between Au nanoparticles. Furthermore, when the pressure is increased to 1×10{sup −2} mbar Ar, it has been observed that the SPR peak for thin film is shifted towards to shorter wavelengths, and it has also been observed that the intensity of absorption peak is decreased.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunability, dielectric, and piezoelectric properties of Ba{sub (1−x)}Ca{sub x}Ti{sub (1−y)}Zr{sub y}O{sub 3} ferroelectric thin films

Tunable ferroelectric capacitors, which exhibit a decrease of the dielectric permittivity (ϵ) under electric field, are widely used in electronics for RF tunable applications (e.g., antenna impedance matching). Current devices use barium strontium titanate as the tunable dielectric, and the need for performance enhancement of the tunable element is the key for device improvement. We report here on libraries of Ba{sub 0.97}Ca{sub 0.03}Ti{sub 1−x}Zr{sub x}O{sub 3} thin films (0 ≤ x ≤ 27%) with a thickness of about 130 nm deposited on IrO{sub 2}/SiO{sub 2}/Si substrates using combinatorial pulsed laser deposition allowing for gradients of composition on one sample. A total of 600 capacitors on a single sample were characterized in order to statistically investigate the dielectric properties. We show that the tunabilty is maximum at intermediate compositions, reaching values up to 60% for an electric field of about 400 kV cm{sup −1}. We attribute the high tunability in the intermediate compositions to the paraelectric-ferroelectric phase transition, which is brought down to room temperature by the addition of Zr. In addition, the piezoelectric coefficient is found to be decreasing with increasing Zr content.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Linearization of dose-response curve of the radiochromic film dosimetry system

Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal neutron-induced single-event upsets in microcontrollers containing boron-10

Single-event upsets (SEUs) were measured in thermal neutron-irradiated microcontrollers with 65-nm node and 130-nm node SRAMs. The suspected upset mechanism is charge deposition from the energetic byproducts of 10 B thermal neutron capture. Although elemental analysis confirmed that both microcontrollers contain 10 B, only the 65-nm node microcontroller exhibited a strong response to thermal neutrons. Monte Carlo simulations were performed to investigate the effects of 11 B enrichment on thermal neutron-induced SEUs in a 65-nm SRAM node when boron is present in the p -type well, p -type source and drain, or tungsten plug. Simulations indicate that the byproducts of 10 B(n,α) 7 Li reactions are capable of generating sufficient charge to upset a 65-nm SRAM. Finally, the highest amount of charge deposition from 10 B(n,α) 7 Li reaction byproducts occurs when natural boron is used to dope the p -type source and drain regions. Simulations also show that the SEU cross section is non-negligible when 11 B-enriched boron is used for doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-EF-BRA-01: A Dual-Use Optical Tomography System for Small Animal Radiation Research Platform (SARRP)

Purpose: We develop a novel dual-use configuration for a tri-modality, CBCT/bioluminescence tomography(BLT)/fluorescence tomography(FT), imaging system with the SARRP that can function as a standalone system for longitudinal imaging research and on-board the SARRP to guide irradiation. BLT provides radiation guidance for soft tissue target, while FT offers functional information allowing mechanistic investigations. Methods: The optical assembly includes CCD camera, lens, filter wheel, 3-way mirrors, scanning fiber system and light-tight enclosure. The rotating mirror system directs the optical signal from the animal surface to the camera at multiple projection over 180 degree. The fiber-laser system serves as the external light source for the FT application. Multiple filters are used for multispectral imaging to enhance localization accuracy using BLT. SARRP CBCT provides anatomical information and geometric mesh for BLT/FT reconstruction. To facilitate dual use, the 3-way mirror system is cantilevered in front of the camera. The entire optical assembly is driven by a 1D linear stage to dock onto an independent mouse support bed for standalone application. After completion of on-board optical imaging, the system is retracted from the SARRP to allow irradiation of the mouse. Results: A tissue-simulating phantom and a mouse model with a luminescence light source are used to demonstrate the function of the dual-use optical system. Feasibility data have been obtained based on a manual-docking prototype. The center of mass of light source determined in living mouse with on-board BLT is within 1±0.2mm of that with CBCT. The performance of the motorized system is expected to be the same and will be presented. Conclusion: We anticipate the motorized dual use system provide significant efficiency gain over our manual docking and off-line system. By also supporting off-line longitudinal studies independent of the SARRP, the dual-use system is a highly efficient and cost-effective platform to facilitate optical imaging for pre-clinical radiation research. The work is supported by NIH R01CA158100 and Xstrahl Ltd. Drs. John Wong and Iulian Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University. John Wong also has a consultant agreement with Xstrahl Ltd.

60 APPLIED LIFE SCIENCES↗

Nuclear Track Detector Characterization via Alpha-Spectrometry for Radioprotection Use

Solid Nuclear Track Detectors (SNTDs), CR-39 type, are usually adopted to monitor radon gas concentrations. In order to characterize the detectors according to track geometrical parameters, detectors were irradiated inside a vacuum chamber by alpha particles at twelve energy values, obtained by different Mylar foils in front of a {sup 241}Am source. The alpha energy values were verified using a Si detector. After the exposure to the alpha particles, the detectors were chemically etched to enlarge the tracks, which were then analyzed by means of a semiautomatic system composed of an optical microscope equipped with a CCD camera connected to a personal computer to store images. A suitable routine analyzed the track parameters: major and minor axis length and mean grey level, allowing us to differentiate tracks according to the incident alpha energy and then to individuate the discrimination factors for radon alpha tracks. The combined use of geometrical and optical parameters allows one to overcome the ambiguity in the alpha energy determination due to the non-monotonicity of each parameter versus energy. After track parameter determination, a calibration procedure was performed by means of a radon chamber. The calibration was verified through an inter-comparing survey.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low secondary electron yield engineered surface for electron cloud mitigation

Secondary electron yield (SEY or δ) limits the performance of a number of devices. Particularly, in high-energy charged particle accelerators, the beam-induced electron multipacting is one of the main sources of electron cloud (e-cloud) build up on the beam path; in radio frequency wave guides, the electron multipacting limits their lifetime and causes power loss; and in detectors, the secondary electrons define the signal background and reduce the sensitivity. The best solution would be a material with a low SEY coating and for many applications δ < 1 would be sufficient. We report on an alternative surface preparation to the ones that are currently advocated. Three commonly used materials in accelerator vacuum chambers (stainless steel, copper, and aluminium) were laser processed to create a highly regular surface topography. It is shown that this treatment reduces the SEY of the copper, aluminium, and stainless steel from δ{sub max} of 1.90, 2.55, and 2.25 to 1.12, 1.45, and 1.12, respectively. The δ{sub max} further reduced to 0.76–0.78 for all three treated metals after bombardment with 500 eV electrons to a dose between 3.5 × 10{sup −3} and 2.0 × 10{sup −2} C·mm{sup −2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrodynamic conditions in laser irradiated buried layer experiments

The calculation of open shell ionization level and radiative properties of materials in Non-Local Thermal Equilibrium (NLTE) is currently still a major challenge for any atomic model. The predictions of various NLTE atomic codes at these conditions still differ significantly. In recent years, a new buried layer platform was developed at the Lawrence Livermore National Laboratory and the Laboratory for Laser Energetics. This platform is used to measure ionization distribution and emission of open L-shell, mid-Z ions and open M-shell, high-Z ions at NLTE conditions that are relevant in many laser plasma applications. These experiments offer a unique chance for benchmarking the atomic models. In order to perform these experiments, a uniform well characterized plasma source is required. In this work, we present one-dimensional (1D) and two-dimensional simulations of the experimental platform. These simulations were used for both the design and the analysis of the experiments. The simulations demonstrate the different phases of hydrodynamic evolution of the target and identify the time windows in which uniform conditions can be achieved. A 1D expansion of the target was found to be adequate to describe the target's evolution for most of the experiment duration. The fast 1D simulations were compared with recent experimental results from the Omega laser facility. The sensitivity of the results to several modeling parameters such as the electron flux limiter and laser resonant absorption is reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full characterization of ultrathin 5-nm low-k dielectric bilayers: Influence of dopants and surfaces on the mechanical properties

Ultrathin films and multilayers, with controlled thickness down to single atomic layers, are critical for advanced technologies ranging from nanoelectronics to spintronics to quantum devices. However, for thicknesses less than 10 nm, surfaces and dopants contribute significantly to the film properties, which can differ dramatically from that of bulk materials. Therefore, for amorphous films being developed as low dielectric constant interfaces for nanoelectronics, the presence of surfaces or dopants can soften films and degrade their mechanical performance. Here we use coherent short-wavelength light to fully and nondestructively characterize the mechanical properties of individual films as thin as 5 nm within a bilayer. In general, we find that the mechanical properties depend both on the amount of doping and the presence of surfaces. In very thin (5-nm) silicon carbide bilayers with low hydrogen doping, surface effects induce a substantial softening - by almost an order of magnitude - compared with the same doping in thicker (46-nm) bilayers. These findings are important for informed design of ultrathin films for a host of nano- and quantum technologies, and for improving the switching speed and efficiency of next-generation electronics.

36 MATERIALS SCIENCE↗

Epitaxial integration of photoresponsive Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} with Si(001)

Previously it has been shown that the resistivity of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} epitaxial thin films on oxide substrates decreases significantly upon illumination with visible light. The resistivity decrease is observed over a wide temperature range and is understood as arising due to the destruction of charge ordering. The light responsivity makes Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} thin films attractive for photonic and optoelectronic device applications. In this paper, we report the heteroepitaxy of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} thin films on (001) Si which is relevant for the potential integration of the optoelectronic/photonic functionality of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} with semiconductor electronics. As in the case of other perovskite oxides, heteroepitaxy of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} on Si requires the use of buffer layers to circumvent the problems associated with the presence of an amorphous native silicon dioxide layer and the reactivity of perovskite oxides with Si at high temperatures. We demonstrate that high quality epitaxial thin films of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} can be grown via pulse laser deposition on Si that has been prebuffered with a SrTiO{sub 3} layer via a Motorola molecular beam epitaxy process. The magnitude and dynamics of the photoresponse in these films is comparable to that of Bi{sub 0.4}Ca{sub 0.6}MnO{sub 3} films on oxide substrates.

36 MATERIALS SCIENCE↗

Tank Farms and Waste Feed Delivery - 12507

The mission of the Department of Energy's Office of River Protection (ORP) is to safely retrieve and treat the 56 million gallons of Hanford's tank waste and close the Tank Farms to protect the Columbia River. Our discussion of the Tank Farms and Waste Feed Delivery will cover progress made to date with Base and Recovery Act funding in reducing the risk posed by tank waste and in preparing for the initiation of waste treatment at Hanford. The millions of gallons of waste are a by-product of decades of plutonium production. After irradiated fuel rods were taken from the nuclear reactors to the processing facilities at Hanford they were exposed to a series of chemicals designed to dissolve away the rod, which enabled workers to retrieve the plutonium. Once those chemicals were exposed to the fuel rods they became radioactive and extremely hot. They also couldn't be used in this process more than once. Because the chemicals are caustic and extremely hazardous to humans and the environment, underground storage tanks were built to hold these chemicals until a more permanent solution could be found. The underground storage tanks range in capacity from 55,000 gallons to more than 1 million gallons. The tanks were constructed with carbon steel and reinforced concrete. There are eighteen groups of tanks, called 'tank farms', some having as few as two tanks and others up to sixteen tanks. Between 1943 and 1964, 149 single-shell tanks were built at Hanford in the 200 West and East Areas. Heat generated by the waste and the composition of the waste caused an estimated 67 of these single-shell tanks to leak into the ground. Washington River Protection Solutions is the prime contractor responsible for the safe management of this waste. WRPS' mission is to reduce the risk to the environment that is posed by the waste. All of the pumpable liquids have been removed from the single-shell tanks and transferred to the double-shell tanks. What remains in the single-shell tanks are solid and semi-solid wastes. Known as salt-cakes, they have the consistency of wet beach sand. Some of the waste resembles small broken ice, or whitish crystals. Because the original pumps inside the tanks were designed to remove only liquid waste, other methods have been developed to reach the remaining waste. Access to the tank waste is through long, typically skinny pipes, called risers, extending out of the tanks. It is through these pipes that crews are forced to send machines and devices into the tanks that are used to break up the waste or push it toward a pump. These pipes range in size from just a few inches to just over a foot in diameter because they were never intended to be used in this manner. As part of the agreement regulating Hanford cleanup, crews must remove at least 99% of the material in every tank on the site, or at least as much waste that can be removed based on available technology. To date, seven single-shell tanks have been emptied, and work is underway in another 10 tanks in preparation for additional retrieval activities. Two barriers have been installed over single-shell tanks to prevent the intrusion of surface water down to the tanks, with additional barriers planned for the future. Single and double-shell tank integrity analyses are ongoing. Because the volume of the waste generated through plutonium production exceeded the capacity of the single-shell tanks, between 1968 and 1986 Hanford engineers built 28 double-shell tanks. These tanks were studied and made with a second shell to surround the carbon steel and reinforced concrete. The double-shell tanks have not leaked any of their waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anomalous photoresponse of GaN x-ray Schottky detectors

GaN based materials are believed to be very stable materials, in particular, under irradiation by high energy photons such as x rays. We have studied x-ray detectors based on GaN Schottky diodes. Vertical Schottky diodes were fabricated based on a 20 mum thick undoped GaN layer grown on a conductive GaN substrate. Their photoresponse to near UV light and to x rays was measured. While the response to near UV light was fast and linear as expected, anomalous behaviors were observed under x-ray illumination. The photocurrent increases as the third power of the incident x-ray flux. The photocurrent transient when the x rays is turned on are long and nonexponential (S shape) and strongly differs from the off transient which is fast and exponential. Also, a very strong quenching of the x-ray photoresponse is observed when the detector is simultaneously illuminated with visible light. All of these anomalous behaviors are explained in the frame of a complete model involving traps and tunnel currents. A reasonable quantitative agreement between the model and the experimental data is obtained.

36 MATERIALS SCIENCE↗

A high accuracy femto-/picosecond laser damage test facility dedicated to the study of optical thin films

A laser damage test facility delivering pulses from 100 fs to 3 ps and designed to operate at 1030 nm is presented. The different details of its implementation and performances are given. The originality of this system relies the online damage detection system based on Nomarski microscopy and the use of a non-conventional energy detection method based on the utilization of a cooled CCD that offers the possibility to obtain the laser induced damage threshold (LIDT) with high accuracy. Applications of this instrument to study thin films under laser irradiation are presented. Particularly the deterministic behavior of the sub-picosecond damage is investigated in the case of fused silica and oxide films. It is demonstrated that the transition of 0-1 damage probability is very sharp and the LIDT is perfectly deterministic at few hundreds of femtoseconds. The damage process in dielectric materials being the results of electronic processes, specific information such as the material bandgap is needed for the interpretation of results and applications of scaling laws. A review of the different approaches for the estimation of the absorption gap of optical dielectric coatings is conducted and the results given by the different methods are compared and discussed. The LIDT and gap of several oxide materials are then measured with the presented instrument: Al{sub 2}O{sub 3}, Nb{sub 2}O{sub 5}, HfO{sub 2}, SiO{sub 2}, Ta{sub 2}O{sub 5}, and ZrO{sub 2}. The obtained relation between the LIDT and gap at 1030 nm confirms the linear evolution of the threshold with the bandgap that exists at 800 nm, and our work expands the number of tested materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-optical reconfiguration of single silicon-vacancy centers in diamond for non-volatile memories

Strain engineering is vital for tuning the optical and spin properties of solid-state color centers, enhancing spin coherence and compensating emission wavelength shift. Here, we develop an all-optical approach to directly modify the local strain of color centers at the nanoscale by migrating the nearby defect. High-power pulsed optical irradiation triggers defect migration, which subsequently leads to the redistribution of the local crystal lattice of the host material. This redistribution alters the strain experienced by nearby color centers. Using silicon-vacancy centers in diamond, we validate this method and demonstrate a ground state splitting enhancement of up to 1.8 THz. Unlike conventional methods, our approach requires no external fields or nanostructure modifications, enabling non-volatile strain control and optical memory functionality across wide temperature ranges. Its local, permanent nature offers a scalable path for enhancing spin coherence in large-scale quantum systems and has potential applications in photonic machine learning.

Nanoscale devices↗

SU-F-18C-10: Clinical Implementation of Radiochromic Film Based CTDI Measurements

Purpose: To evaluate accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV CBCT systems attached to linear accelerators. Methods: Energy dependence of Gafchromic XR-QA2(R) film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air kerma in air (up to 10 cGy). Change in film reflectance was determined with an in-house written code using images produced by a flatbed document scanner. Calibration curves for each beam quality were created, and film responses for same air-kerma values were compared.Sets of film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols on CT-simulators and CBCT systems. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured CTDIvol values were compared to tabulated CTDIvol values. Results: Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. The averaged measured CTDI values presented a mean variation for the same machine and protocol of 2.6%. However, measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Conclusion: We found that in relatively broad range of beam qualities used in diagnostic radiology variation of film response is within ±5% resulting in ±15% systematic error in dose estimates if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values for different protocols and imaging systems used within radiotherapy department strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom as suggested by TG-111. This work was supported by the Natural Sciences and Engineering Research Council of Canada, Contract No. 386009; Partial support by CREATE, Medical Physics Research Training Network grant of the Natural Science and Engineering Research Council, Contract No. 432290.

07 ISOTOPE AND RADIATION SOURCES↗

Tracking tumor boundary in MV-EPID images without implanted markers: A feasibility study

Purpose: To develop a markerless tracking algorithm to track the tumor boundary in megavoltage (MV)-electronic portal imaging device (EPID) images for image-guided radiation therapy. Methods: A level set method (LSM)-based algorithm is developed to track tumor boundary in EPID image sequences. Given an EPID image sequence, an initial curve is manually specified in the first frame. Driven by a region-scalable energy fitting function, the initial curve automatically evolves toward the tumor boundary and stops on the desired boundary while the energy function reaches its minimum. For the subsequent frames, the tracking algorithm updates the initial curve by using the tracking result in the previous frame and reuses the LSM to detect the tumor boundary in the subsequent frame so that the tracking processing can be continued without user intervention. The tracking algorithm is tested on three image datasets, including a 4-D phantom EPID image sequence, four digitally deformable phantom image sequences with different noise levels, and four clinical EPID image sequences acquired in lung cancer treatment. The tracking accuracy is evaluated based on two metrics: centroid localization error (CLE) and volume overlap index (VOI) between the tracking result and the ground truth. Results: For the 4-D phantom image sequence, the CLE is 0.23 ± 0.20 mm, and VOI is 95.6% ± 0.2%. For the digital phantom image sequences, the total CLE and VOI are 0.11 ± 0.08 mm and 96.7% ± 0.7%, respectively. In addition, for the clinical EPID image sequences, the proposed algorithm achieves 0.32 ± 0.77 mm in the CLE and 72.1% ± 5.5% in the VOI. These results demonstrate the effectiveness of the authors’ proposed method both in tumor localization and boundary tracking in EPID images. In addition, compared with two existing tracking algorithms, the proposed method achieves a higher accuracy in tumor localization. Conclusions: In this paper, the authors presented a feasibility study of tracking tumor boundary in EPID images by using a LSM-based algorithm. Experimental results conducted on phantom and clinical EPID images demonstrated the effectiveness of the tracking algorithm for visible tumor target. Compared with previous tracking methods, the authors’ algorithm has the potential to improve the tracking accuracy in radiation therapy. In addition, real-time tumor boundary information within the irradiation field will be potentially useful for further applications, such as adaptive beam delivery, dose evaluation.

60 APPLIED LIFE SCIENCES↗