Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Beam dynamics in independent phased cavities

Linear accelerators containing the sequence of independently phased cavities with constant geometrical velocity along each structure are widely used in practice. The chain of cavities with identical cell lengths is utilized within a certain beam velocity range, with subsequent transformation to the next chain with higher cavity velocity. Design and analysis of beam dynamics in this type of accelerator are usually performed using numerical simulations. A full theoretical description of particle acceleration in an array of independent phased cavities has not been developed. In the present paper, we provide an analytical treatment of beam dynamics in such linacs employing Hamiltonian formalism. We begin our analysis with an examination of beam dynamics in an equivalent traveling wave of a single cavity, propagating within accelerating section with constant phase velocity. We then consider beam dynamics in arrays of cavities, utilizing an effective traveling wave propagating along with the whole accelerator with the velocity of synchronous (reference) particle. The analysis concluded with the determination of the matched beam conditions. Finally, we present a beam dynamics study in 805 MHz Coupled Cavity Linac of the LANSCE accelerator facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Tunable x-ray free electron laser multi-pulses with nanosecond separation

X-ray Free Electron Lasers provide femtosecond x-ray pulses with narrow bandwidth and unprecedented peak brightness. Special modes of operation have been developed to deliver double pulses for x-ray pump, x-ray probe experiments. However, the longest delay between the two pulses achieved with existing single bucket methods is less than 1 picosecond, thus preventing the exploration of longer time-scale dynamics. We present a novel two-bucket scheme covering delays from 350 picoseconds to hundreds of nanoseconds in discrete steps of 350 picoseconds. Performance for each pulse can be similar to the one in a single pulse operation. The method has been experimentally tested with the Linac Coherent Light Source (LCLS-I) and the copper linac with LCLS-II hard x-ray undulators.

47 OTHER INSTRUMENTATION↗

Numerical study of a linear accelerator using laser-generated proton beams as a source

The injection of laser-generated protons through conventional drift tube linear accelerators (linacs) has been studied numerically. For this, we used the parameters of the proton source produced by ultraintense lasers, i.e., with an intrinsic high beam quality. The numerical particle tracing code PARMELA[L. M. Young and J. H. Billen, LANL Report No. LA-UR-96-1835, 2004] is then used to inject experimentally measured laser-generated protons with energies of 7{+-}0.1 MeV and rms un-normalized emittance of 0.180 mm mrad into one drift tube linac tank that accelerated them to more than 14 MeV. The simulations exhibit un-normalized emittance growths of 8 in x direction and 22.6 in y direction, with final emittances lower than those produced using conventional sources, allowing a potential luminosity gain for the final beam. However, the simulations also exhibit a limitation in the allowed injected proton charge as, over 0.112 mA, space charge effect worsens significantly the beam emittance.

43 PARTICLE ACCELERATORS↗

A short working distance multiple crystal x-ray spectrometer

For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed {approx}1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K{beta} x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L{alpha}{sub 2} partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary.

36 MATERIALS SCIENCE↗

The Use of Ionization Electron Columns for Space-Charge Compensation in High Intensity Proton Accelerators

We discuss a recent proposal to use strongly magnetized electron columns created by beam ionization of the residual gas for compensation of space charge forces of high intensity proton beams in synchrotrons and linacs. The electron columns formed by trapped ionization electrons in a longitudinal magnetic field that assures transverse distribution of electron space charge in the column is the same as in the proton beam. Electrostatic electrodes are used to control the accumulation and release of the electrons. Ions are not magnetized and drift away without affecting the compensation. Possible technical solution for the electron columns is presented. We also discuss the first numerical simulation results for space-charge compensation in the FNAL Booster and results of relevant beam studies in the Tevatron.

43 PARTICLE ACCELERATORS↗

Development of High Gradient Laser Wakefield Accelerators Towards Nuclear Detection Applications at LBNL

Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma channel at low density. This demonstrates the production of GeV beams from devices much smaller than conventional linacs, and confirms the anticipated scaling of laser driven accelerators to GeV energies. Stable performance at 0.5 GeV was demonstrated. Experiments and simulations are in progress to control injection of particles into the wake and hence to improve beam quality and stability. Using plasma density gradients to control injection, stable beams at 1 MeV over days of operation, and with an order of magnitude lower absolute momentum spread than previously observed, have been demonstrated. New experiments are post-accelerating the beams from controlled injection experiments to increase beam quality and stability. Thomson scattering from such beams is being developed to provide collimated multi-MeV monoenergetic gamma sources for security applications from compact devices. Such sources can reduce dose to target and increase accuracy for applications including photofission and nuclear resonance fluorescence.

43 PARTICLE ACCELERATORS↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High Intensity Positron Source at Saclay: The SOPHI Project

We are building the SOPHI experiment in Saclay, which is a device based on a small 5 MeV electron linac to produce positrons via pair production on a tungsten target. This device should provide 10{sup 8} slow e{sup +}/s, i.e. a factor 300 greater than the strongest activity Na{sub 22} based setup. The SOPHI system has been finalized at the end of 2006 and the main components have been studied and built during 2007. The experiment is currently being assembled and first results are expected for autumn 2008. The electron linac, positron beam production and transport system will be presented, and expected positron production rate reported.

43 PARTICLE ACCELERATORS↗

Optical Restoration of Lead Fluoride Crystals

Due to its relatively high resistance to high radiation, lead fluoride (PbF{sub 2}) crystals are becoming an increasingly popular material of choice for electromagnetic calorimetry, such as for experiments requiring the measurement of high-energy photons in Hall A of Jefferson Lab. For our studies we irradiated the PbF{sub 2} crystals using an electron linear accelerator (LINAC) followed by exposing the crystals to blue light so as to restore the nominal optical properties. This technique of optical bleaching with blue light affords an efficient and low-cost means for reversing the deleterious effects of optical transmission loss in radiation-damaged lead fluoride crystals. Whereas earlier experiments irradiated the PbF{sub 2} samples with 1.1 and 1.3 MeV gammas from {sup 60}Co, we used pulsed beams of energetic electrons from the tunable 25-MeV LINAC at Idaho Accelerator Center of Idaho State University in Pocatello, Idaho. A 20-MeV beam of electrons was targeted onto four separate 19 cm length samples of lead fluoride over periods of 1, 2, and 4 hours yielding doses between 7 kGy and 35 kGy. Samples were then bleached with blue light of wavelength 410-450 nm for periods between 19.5 and 24 hours. We performed this process twice - radiation, bleaching, radiation, and then followed by bleaching again - for each of these four PbF{sub 2} samples. We shall discuss the efficacy of blue light curing on samples that have undergone two cycles of electron irradiation and optical bleaching.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of pulsed x-ray trains produced by laser-electron Compton scatterings

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10{sup 5} Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

43 PARTICLE ACCELERATORS↗

rf improvements for Spallation Neutron Source H{sup -} ion source

The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering {approx}38 mA H{sup -} beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

43 PARTICLE ACCELERATORS↗

Ultrashort high quality electron beam from laser wakefield accelerator using two-step plasma density profile

In this paper, we first use the rf linac injector mechanism to generate ultrashort high quality electron beam from laser wakefield accelerator (LWFA) with two-step plasma density profile successfully. We incorporate the physics principle in the conventional rf linac injector into the LWFA by using two-step plasma density to decrease the wavelength of the wakefield in plasma. Using this mechanism, we observe a ultrashort high quality electron beam (the rms energy spread is 1.9%, and the rms bunch length is 2 fs) in the simulation. The ultrashort intense terahertz coherent radiation (200 MW, 2 fs) can be generated with the proposed laser wakefield accelerator.

43 PARTICLE ACCELERATORS↗

Status of the SAGA Light Source

The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

43 PARTICLE ACCELERATORS↗

Single-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer

A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.

36 MATERIALS SCIENCE↗

Overview of Photoinjectors

High-brightness electron beam sources play a crucial role in many advanced acceleration schemes as well as linac-based light sources such as Energy Recovery Linac (ERL) based light sources and FELs. Three varieties electron sources (photo, thermionic, and field emission) the photoinjector is especially attractive due to its innate ability to control the time structure of intense electron bunches with low transverse and longitudinal emittance. In all cases, the quality of the bunch begins with the intrinsic emittance and time response of the photocathode, and we discuss the trade-offs involved between the various material choices. A variety of longitudinal laser pulse-shaping techniques are currently being developed to linearize space charge forces or create trains of ultra-short bunches. The emittance compensation technique mitigates the growth of the projected emittance due to the linear space charge force while the bunch is accelerated and compressed in an injector. While the normal conducting rf photoinjector is the workhorse of this field, the dc photoinjector is being pushed to its high-voltage limits, and the year 2010 promises to be a critical year for the superconducting rf photoinjector. Parallel to the development of the hardware, rapid progress has also been made with modeling codes, theory, and bench marking of diagnostics. We attempt to give both a tutorial of photoinjectors and a review of the current state of the art in this rapidly developing field.

43 PARTICLE ACCELERATORS↗

Process Performance of Optima XEx Single Wafer High Energy Implanter

To meet the process requirements for well formation in future CMOS memory production, high energy implanters require more robust angle, dose, and energy control while maintaining high productivity. The Optima XEx high energy implanter meets these requirements by integrating a traditional LINAC beamline with a robust single wafer handling system. To achieve beam angle control, Optima XEx can control both the horizontal and vertical beam angles to within 0.1 degrees using advanced beam angle measurement and correction. Accurate energy calibration and energy trim functions accelerate process matching by eliminating energy calibration errors. The large volume process chamber and UDC (upstream dose control) using faraday cups outside of the process chamber precisely control implant dose regardless of any chamber pressure increase due to PR (photoresist) outgassing. An optimized RF LINAC accelerator improves reliability and enables singly charged phosphorus and boron energies up to 1200 keV and 1500 keV respectively with higher beam currents. A new single wafer endstation combined with increased beam performance leads to overall increased productivity. We report on the advanced performance of Optima XEx observed during tool installation and volume production at an advanced memory fab.

43 PARTICLE ACCELERATORS↗

TAC Proton Accelerator Facility: The Status and Road Map

Proton Accelerator (PA) Project is at a stage of development, working towards a Technical Design Report under the roof of a larger-scale Turkish Accelerator Center (TAC) Project. The project is supported by the Turkish State Planning Organization. The PA facility will be constructed in a series of stages including a 3 MeV test stand, a 55 MeV linac which can be extended to 100+ MeV, and then a full 1-3 GeV proton synchrotron or superconducting linac. In this article, science applications, overview, and current status of the PA Project will be given.

43 PARTICLE ACCELERATORS↗