Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Development of a scanning surface probe for nanoscal tip-enhanced desorption/ablation

We report on the development of a versatile scanning apparatus for nanoscale surface sampling that utilizes the interaction of laser radiation at a sharp probe tip to effect desorption/ablation on opaque substrates. The process, which currently yields surface craters as small as ~50 nm diameter X5 nm deep, has been demonstrated with both metal-coated and bare silicon tips. Desorption/ablation under the tip occurs at illumination intensities below the corresponding optical far-field threshold, suggesting that the latter process should not degrade the spatial resolution attainable for proposed chemical imaging methods based on the scanning surface probe.

47 OTHER INSTRUMENTATION↗

Arctic Methane Carbon Aerosols and Tracers Study

The Arctic Methane, Carbon Aerosols, and Tracers Study was a measurement campaign at the NOAA Barrow Observatory and DOE ARM North Slope of Alaska sites in Barrow that involved the deployment of instruments to measure CH 4 , black carbon (BC), and source tracers. The campaign ran from September 1, 2014 to September 1, 2016 and was extended until July 30, 2017.

54 ENVIRONMENTAL SCIENCES↗

Applications of luminescent systems to infectious disease methodology

The characterization of a clinical sample by a simple, fast, accurate, automatable analytical measurement is important in the management of infectious disease. Luminescence assays offer methods rich with options for these measurements. The instrumentation is common to each assay, and the investment is reasonable. Three general procedures were developed to varying degrees of completeness which measure bacterial levels by measuring their ATP, FMN and iron porphyrins. Bacteriuria detection and antibiograms can be determined within half a day. The characterization of the sample for its soluble ATP, FMN or prophyrins was also performed.

Picciolo, G. L.↗

In situ correlative measurements for the ultraviolet differential absorption lidar and the high spectral resolution lidar air quality remote sensors: 1980 PEPE/NEROS program

In situ correlative measurements were obtained with a NASA aircraft in support of two NASA airborne remote sensors participating in the Environmental Protection Agency's 1980persistent elevated pollution episode (PEPE) and Northeast regional oxidant study (NEROS) field program in order to provide data for evaluating the capability of two remote sensors for measuring mixing layer height, and ozone and aerosol concentrations in the troposphere during the 1980 PEPE/NEROS program. The in situ aircraft was instrumented to measure temperature, dewpoint temperature, ozone concentrations, and light scattering coefficient. In situ measurements for ten correlative missions are given and discussed. Each data set is presented in graphical and tabular format aircraft flight plans are included.

Gregory, G. L.↗

CCD camera system for cometary research

The objective is to upgrade the NASA/GSFC 36 inch telescope instrumentation, primarily with a new charge coupled device (CCD) camera system, to permit an effective monitoring program of cometary activity by means of narrowband imaging and spectroscopic techniques. Researchers have twice taken delivery of the CCD camera system from Princeton Scientific Instruments and twice returned it within six weeks for repair. During the times they had the camera system in the lab, they measured the instrumental performance of the TEK 512 x 512 CCD chip (e.g., readout noise, dark current, etc) and developed the complete operational software for the camera system plus several useful observing and data reduction routines for use at the telescope. The CCD camera system is controlled by an IBM-AT computer. The peripheral equipment and software to permit the efficient transfer of large amounts of data to the LASP's computers (VAXs) and subsequent timely reductions are also in place. The Io torus (S II) emission was monitored with a Fabry-Perot scanning spectrometer, in conjunction with the International Jupiter Watch. The CCD camera system will be coupled to a narrowband interference filter imager and a long-slit spectrograph to provide regular and well-calibrated spatial and spectral observations of comets.

Oliversen, R. J.↗

Fighter agility metrics, research, and test

Proposed new metrics to assess fighter aircraft agility are collected and analyzed. A framework for classification of these new agility metrics is developed and applied. A completed set of transient agility metrics is evaluated with a high fidelity, nonlinear F-18 simulation provided by the NASA Dryden Flight Research Center. Test techniques and data reduction methods are proposed. A method of providing cuing information to the pilot during flight test is discussed. The sensitivity of longitudinal and lateral agility metrics to deviations from the pilot cues is studied in detail. The metrics are shown to be largely insensitive to reasonable deviations from the nominal test pilot commands. Instrumentation required to quantify agility via flight test is also considered. With one exception, each of the proposed new metrics may be measured with instrumentation currently available. Simulation documentation and user instructions are provided in an appendix.

Liefer, Randall K.↗

Atlas 2 Animation

The Atmospheric Laboratory for Applications and Science-2 (ATLAS-2), was designed to collect data on the relationship between the sun's energy output and Earth's middle atmosphere and how these factors affect the ozone layer. The ATLAS-2 flew on the Space Shuttle Discovery's mission SST-56, launched on April 8, 1993. The videotape consists of an animated tour of the instruments that were included as part of the mission. The first half of the tape shows the various instruments, pointing to each in turn and identifying each by the associated initialisms. The instruments identified were: the Atmospheric Trace Molecule Spectroscopy (ATMOS), Millimeter Wave Atmospheric Sounder (MAS), Shuttle Solar Backscatter Ultraviolet/A (SSBUV/A) spectrometer, Solar Spectrum Measurement (SOLSPEC) instrument, Solar Ultraviolet Irradiance Monitor (SUSIM), Active Cavity Radiometer (ACR) and Solar Constant (SOLCON).) The second half of the animation shows the same tour without the pointing or the identification of the instruments.

Source record↗

An Analytical Calibration Approach for the Polarimetric Airborne C Band Radiometer

Passive microwave remote sensing is sensitive to the quantity and distribution of water in soil and vegetation. During summer 2000, the Microwave Geophysics Group at the University of Michigan conducted the 7th Radiobrightness Energy Balance Experiment (REBEX-7) over a corn canopy in Michigan. Long time series of brightness temperatures, soil moisture and micrometeorology on the plot scale were taken. This paper addresses the calibration of the NASA GSFC polarimetric airborne C band microwave radiometer (ACMR) that participated in REBEX-7. Passive polarimeters are typically calibrated using an end-to-end approach based upon a standard artificial target or a well-known geophysical target. Analyzing the major internal functional subsystems offers a different perspective. The primary goal of this approach is to provide a transfer function that not only describes the system in its entirety but also accounts for the contributions of each subsystem toward the final modified Stokes parameters. This approach also serves as a realistic instrument simulator, a useful tool for future designs. The ACMR architecture can be partitioned into several functional subsystems. Each subsystem was extensively measured and the estimated parameters were imported into the overall system model. We will present the results of polarimetric antenna measurements, the instrument model as well as four Stokes observations from REBEX-7 using a first order inversion.

Pham, Hanh↗

Optoelectronic pH Meter: Further Details

A collection of documents provides further detailed information about an optoelectronic instrument that measures the pH of an aqueous cell-culture medium to within 0.1 unit in the range from 6.5 to 7.5. The instrument at an earlier stage of development was reported in Optoelectronic Instrument Monitors pH in a Culture Medium (MSC-23107), NASA Tech Briefs, Vol. 28, No. 9 (September 2004), page 4a. To recapitulate: The instrument includes a quartz cuvette through which the medium flows as it is circulated through a bioreactor. The medium contains some phenol red, which is an organic pH-indicator dye. The cuvette sits between a light source and a photodetector. [The light source in the earlier version comprised red (625 nm) and green (558 nm) light-emitting diodes (LEDs); the light source in the present version comprises a single green- (560 nm)-or-red (623 nm) LED.] The red and green are repeatedly flashed in alternation. The responses of the photodiode to the green and red are processed electronically to obtain the ratio between the amounts of green and red light transmitted through the medium. The optical absorbance of the phenol red in the green light varies as a known function of pH. Hence, the pH of the medium can be calculated from the aforesaid ratio.

Jeevarajan, Antony S.↗

Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter

This innovation is a compact, superconducting, channelizing bandpass filter on a single-crystal (0.45 m thick) silicon substrate, which operates from 300 to 600 GHz. This device consists of four channels with center frequencies of 310, 380, 460, and 550 GHz, with approximately 50-GHz bandwidth per channel. The filter concept is inspired by the mammalian cochlea, which is a channelizing filter that covers three decades of bandwidth and 3,000 channels in a very small physical space. By using a simplified physical cochlear model, and its electrical analog of a channelizing filter covering multiple octaves bandwidth, a large number of output channels with high inter-channel isolation and high-order upper stopband response can be designed. A channelizing filter is a critical component used in spectrometer instruments that measure the intensity of light at various frequencies. This embodiment was designed for MicroSpec in order to increase the resolution of the instrument (with four channels, the resolution will be increased by a factor of four). MicroSpec is a revolutionary wafer-scale spectrometer that is intended for the SPICA (Space Infrared Telescope for Cosmology and Astrophysics) Mission. In addition to being a vital component of MicroSpec, the channelizing filter itself is a low-resolution spectrometer when integrated with only an antenna at its input, and a detector at each channel s output. During the design process for this filter, the available characteristic impedances, possible lumped element ranges, and fabrication tolerances were identified for design on a very thin silicon substrate. Iterations between full-wave and lumped-element circuit simulations were performed. Each channel s circuit was designed based on the availability of characteristic impedances and lumped element ranges. This design was based on a tabular type bandpass filter with no spurious harmonic response. Extensive electromagnetic modeling for each channel was performed. Four channels, with 50-GHz bandwidth, were designed, each using multiple transmission line media such as microstrip, coplanar waveguide, and quasi-lumped components on 0.45- m thick silicon. In the design process, modeling issues had to be overcome. Due to the extremely high frequencies, very thin Si substrate, and the superconducting metal layers, most commercially available software fails in various ways. These issues were mitigated by using alternative software that was capable of handling them at the expense of greater simulation time. The design of on-chip components for the filter characterization, such as a broadband antenna, Wilkinson power dividers, attenuators, detectors, and transitions has been completed.

Ehsan, Negar↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the far infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 101/cm (99 microns). The instrumental concept and atmospheric measurements are discussed.

Pickett, H. M.↗

Enabling in-situ LIBS measurements of liquids and slurries

The aim of this work was to explore the use of, and further develop, a in-situ and near-real time LIBS (Laser Induced Breakdown Spectroscopy) instrument to measure liquids relevant to the Hanford site. Specifically, we investigated the feasibility of using LIBS to measure the cation composition of HLW (High Level Waste) streams. In addition, we focused on enabling continuous interrogation of those liquids using the LIBS system. For the first part, we investigated simple (sodium nitrate) solutions as well as various Hanford tank waste surrogate slurries. We showed that relevant cations (such as sodium, aluminum, magnesium, potassium) can be measured via LIBS under good conditions but the results – both quantitative and qualitative (aka reproducibility) – strongly depend on the kind and concentration of the material used. The dependence of signal intensity on concentration was also confirmed by other measurements conducted (sodium chloride and sodium nitrate in water). For the second part, we investigated the influence of varying depth and concentration of a liquid sample. We observed that for the concentrations and fill depths investigated, the liquid fill depth did not impact the emission intensity of the analyte, while concentration is confirmed to have significant effects. The results of the sample depth experiments influenced testing of waste surrogates. In addition, we focused on further developing and adapting data fitting tools in order to efficiently, accurately, and reproducibly identify the elements and materials present in a LIBS spectrum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detecting Trace Contaminants in the Atmosphere

Sensitive instrument uses two low-energy electron beams to detect certain molecules. Experimental instrument identifies and measures trace contaminants in atmosphere. When fully developed, portable instrument expected to measure contaminant concentrations of certain halogen containing molecules as low as one part per trillion. Instrument employs electron beams to ionize contaminant molecules by dissociative attachment of electrons.

Srivastava, S. K.↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A technique for measuring in situ size distribution of aerosols

A multistage cascade impactor instrument employing piezoelectric crystals for real-time aerosol size distribution measurements is described in this paper. The instrument measures the aerosol mass concentration as a function of particle size in 10 size intervals ranging from 0.05 micrometers to 25 micrometers in diameter. The particles are then analyzed for elemental composition and morphology by means of scanning electron microscopy (SEM). Examples of particle size distributions in rocket motor exhaust plumes measured with the instrument are presented together with the elemental composition and morphology obtained by SEM.

Woods, D. C.↗

Analyte-induced spectral filtering in femtosecond transient absorption spectroscopy

Here, we discuss the influence of spectral filtering by samples in femtosecond transient absorption measurements. Commercial instruments for transient absorption spectroscopy (TA) have become increasingly available to scientists in recent years and TA is becoming an established technique to measure the dynamics of photoexcited systems. Furthermore, we show that absorption of the excitation pulse by the sample can severely alter the spectrum and consequently the temporal pulse shape. This “spectral self-filtering” effect can lead to systematic errors and misinterpretation of data, most notably in concentration dependent measurements. Finally, the combination of narrow absorption peaks in the sample with ultrafast broadband excitation pulses is especially prone to this effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗