Search NASA⌕ Search

SEARCH · Search NASA

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Inter-relationship Between Subtropical Pacific Sea Surface Temperature, Arctic Sea Ice Concentration, and North Atlantic Oscillation in Recent Summers

The inter-relationship between subtropical western–central Pacific sea surface temperatures (STWCPSST), sea ice concentrations in the Beaufort Sea (SICBS), and the North Atlantic Oscillation (NAO) in summer are investigated over the period 1980–2016. It is shown that the Arctic response to the remote impact of the Pacific SST is more dominant in recent summers, leading to a frequent occurrence of the negative phase of the NAO following the STWCPSST increase. Lag–correlations of STWCPSST positive (negative) anomalies in spring with the negative (positive) NAO and SICBS loss (recovery) in summer have increased over the last two decades, reaching r = 0.4–0.5 with significance at the 5 percent level. Both observations and the atmospheric general circulation model experiments suggest that the positive STWCPSST anomaly and subsequent planetary-scale wave propagation act to increase the Arctic upper-level geopotential heights and temperatures in the following season. This response extends to Greenland, providing favorable conditions for developing the negative phase of the NAO. Connected with this atmospheric response, SIC and surface albedo decrease with an increase in the surface net shortwave flux over the Beaufort Sea. Examination of the surface energy balance (radiative and turbulent fluxes) reveals that surplus energy that can heat the surface increases over the Arctic, enhancing the SIC reduction.

SST↗

Storing carbon dioxide in saline formations : analyzing extracted water treatment and use for power plant cooling.

In an effort to address the potential to scale up of carbon dioxide (CO{sub 2}) capture and sequestration in the United States saline formations, an assessment model is being developed using a national database and modeling tool. This tool builds upon the existing NatCarb database as well as supplemental geological information to address scale up potential for carbon dioxide storage within these formations. The focus of the assessment model is to specifically address the question, 'Where are opportunities to couple CO{sub 2} storage and extracted water use for existing and expanding power plants, and what are the economic impacts of these systems relative to traditional power systems?' Initial findings indicate that approximately less than 20% of all the existing complete saline formation well data points meet the working criteria for combined CO{sub 2} storage and extracted water treatment systems. The initial results of the analysis indicate that less than 20% of all the existing complete saline formation well data may meet the working depth, salinity and formation intersecting criteria. These results were taken from examining updated NatCarb data. This finding, while just an initial result, suggests that the combined use of saline formations for CO{sub 2} storage and extracted water use may be limited by the selection criteria chosen. A second preliminary finding of the analysis suggests that some of the necessary data required for this analysis is not present in all of the NatCarb records. This type of analysis represents the beginning of the larger, in depth study for all existing coal and natural gas power plants and saline formations in the U.S. for the purpose of potential CO{sub 2} storage and water reuse for supplemental cooling. Additionally, this allows for potential policy insight when understanding the difficult nature of combined potential institutional (regulatory) and physical (engineered geological sequestration and extracted water system) constraints across the United States. Finally, a representative scenario for a 1,800 MW subcritical coal fired power plant (amongst other types including supercritical coal, integrated gasification combined cycle, natural gas turbine and natural gas combined cycle) can look to existing and new carbon capture, transportation, compression and sequestration technologies along with a suite of extracting and treating technologies for water to assess the system's overall physical and economic viability. Thus, this particular plant, with 90% capture, will reduce the net emissions of CO{sub 2} (original less the amount of energy and hence CO{sub 2} emissions required to power the carbon capture water treatment systems) less than 90%, and its water demands will increase by approximately 50%. These systems may increase the plant's LCOE by approximately 50% or more. This representative example suggests that scaling up these CO{sub 2} capture and sequestration technologies to many plants throughout the country could increase the water demands substantially at the regional, and possibly national level. These scenarios for all power plants and saline formations throughout U.S. can incorporate new information as it becomes available for potential new plant build out planning.

01 COAL, LIGNITE, AND PEAT↗

BEAM ACCELERATION BY A MULTICELL RF CAVITY STRUCTURE PROPOSED FOR AN IMPROVED YIELD IN HYDROFORMING

We study the accelerating properties of a new multicell cavity structure with irises forming a rectangular aperture between the cavity cells. We are interested in this structure because, from a mechanical point of view, it may be possible to manufacture with high quality using a hydroforming process. RF analysis shows that the rectangular iris shape provides some asymmetric transverse focusing per half RF period, particularly for low beam energies. If the horizontal and vertical rectangular irises are interleaved, the net transverse focusing could be increased. Here we present studies of the acceleration and transport properties of these cavities by tracking particles using the ORBIT Code through time-dependent 3D cavity fields taken from CST MWS.

43 PARTICLE ACCELERATORS↗

A Tale of Two Cities: Greensburg Resurrected as a National Model for Green Communities

This fact sheet provides a summary of how NREL's technical assistance in Greensburg, Kansas, helped the town rebuild green after recovering from a tornado in May 2007. To help local distributed system owners get the most value for electricity sent back to the grid, NREL drafted safety and reliability ordinances, an interconnection agreement, and net-metering policies for the city to consider. NREL and the Energy Department also assisted with wind energy resource analysis, feasibility studies, and business plans.

disaster recovery↗

The Industrial Efficiency and Decarbonization Office

The Industrial Efficiency and Decarbonization Office (IEDO) supports innovation technologies and the adoption of practices to enable the industrial sector to cost-effectively reduce greenhouse gas (GHG) emissions. IEDO and its programs are critical to putting the Nation on a pathway to reduce CO2 emissions by 50% by 2030 when compared to 2005 levels, and to achieve net-zero carbon emissions by 2050. With 30% of primary energy-related emissions attributable to the industrial sector, IEDO builds upon a foundation of energy efficiency as a decarbonization pathway to include process electrification, use of low carbon fuels and feedstocks, and carbon capture to meet industrial emissions reductions targets. IEDO provides planning, management, and direction necessary for a balanced national program of research, development, demonstration, technical assistance, and workforce development to drive energy, materials and production efficiency, and decarbonization across the industrial sector.

Energy-Intensive Industries, Cross-Sector Technolo↗

Heat pumps in the United States: Market potentials, challenges and opportunities, technology advances

The US heat pump market has been affected by the socioeconomic impacts of the COVID-19 pandemic. However, the Biden administration’s goal of net-zero greenhouse gas emissions by 2050 through electrification and clean energy technologies is accelerating the research, development, and deployment of heat pumps in the United States for improved energy performance, reduced greenhouse gas emissions, and wider adoption. The US heat pump market has experienced steady growth since 2010. In 2020, heat pumps surpassed gas furnace shipments for the first time, and the trend maintains through 2022. The current priority is to improve the affordability of energy and equitable access to heat pump technologies through cost reductions and further accelerate this trend. In addition, current R&D includes emphases on alternative refrigeration technology and lower–global warming potential refrigerants to reduce direct emissions. Heat pump market share is expected to grow as regulatory policies and financial incentives steer the building sector toward decarbonization. This paper reviews policies and market trends, discusses the challenges and opportunities in the current policy landscape, and reviews current research in the United States.

Malhotra, Mini↗

Electric Vehicles: A Sustainable Solution for Transportation Systems

The imperative for strong and rapid emissions reductions to mitigate global warming and enhance air quality necessitates a transition to net-zero emissions. This shift requires significant changes throughout the entire energy supply-demand ecosystems, tailored to various sectors. Transportation stands as the least-diversified energy sector and the largest source of U.S. GHG emissions. As the primary enabler for vehicle decarbonization when paired with clean electricity, electric vehicles (EVs) will play a pivotal role in the future. This talk summarizes current status of EV technologies and markets, future projections, and opportunities associated with a conversion to EV for all on-road vehicles. Moreover, EVs are poised to drive substantial growth in electricity demand and presents a unique opportunity to provide demand-side flexibility that is crucial for future renewable-dominated electricity systems. Smart integration of EVs can strengthen the grid, reducing costs and enhancing resilience.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Seasonal and Interannual Variations of Evaporation and their Relations with Precipitation, Net Radiation, and Net Carbon Accumulation for the Gediz Basin Area

A model combining the rate of carbon assimilation with water and energy balance equations has been run using satellite and ancillary data for a period of 60 months (January 1986 to December 1990). Calculations for the Gediz basin area give mean annual evaporation as 395 mm, which is composed of 45% transpiration, 42% soil evaporation and 13% interception. The coefficient of interannual variation of evaporation is found to be 6%, while that for precipitation and net radiation are, respectively, 16% and 2%, illustrating that net radiation has an important effect in modulating interannual variation of evaporation. The mean annual water use efficiency (i.e., the ratio of net carbon accumulation and total evaporation) is ca. 1 g/sq m/mm, and has a coefficient of interannual variation of 5%. A comparison of the mean water use efficiency with field observations suggests that evaporation over the area is utilized well for biomass production. The reference crop evaporation for irrigated areas has annual mean and coefficient of variation as, respectively, 1176 mm and 3%. The total evaporation during three summer months of peak evaporation (June-August) is estimated to be about 575 mm for irrigated crops like maize and cotton. Seasonal variations of the fluxes are presented.

Choudhury, Bhaskar J.↗

A Data-Driven Method for Adaptive Reserve Requirement Estimation via Probabilistic Net Load Forecasting

The University of Colorado Boulder Boulder, CO, 80309, USA With the increasing penetration of renewable energy, power systems are subject to more uncertainty. This makes power system reserve scheduling more challenging. Most of the current reserve requirement determination methods calculate reserve requirements based on historical data, which does not consider the real-time or future system uncertainty. In this paper, a data-driven method is developed to determine the non-spinning reserve requirement (NSRR) in the Electric Reliability Council of Texas (ERCOT) system. The method follows the procedure of the current ERCOT method while adaptively determining the NSRR based on probabilistic net load forecasts. Case studies with two years of ERCOT data show that the developed method significantly reduces the NSRR by introducing an adaptive temporal resolution and update rate. Sensitivity analysis with different forecasting and percentile thresholds indicates the flexibility of the developed method.

non-spinning reserve↗

Maximizing energy efficiency in wastewater treatment plants: A data-driven approach for waste heat recovery and an economic analysis using Organic Rankine Cycle and thermal energy storage

Maximizing energy efficiency through waste heat recovery (WHR) processes is crucial for sustainable and ecofriendly operations across multiple industries, notably in wastewater treatment plants (WWTPs). This work proposes a comprehensive approach for assessing the WHR feasibility in WWTPs, structured in two main objectives. Firstly, an Artificial Neural Network (ANN) model is developed to accurately predict WHR based on operational data, including biogas temperature, biogas pressure, daily production in kWh, and WHR values in kWh th . The second objective focuses on economically evaluating the WHR feasibility based on the estimated WHR values obtained by the ANN model, and then realistically assessing the economic feasibility of integrating the Organic Rankine Cycle (ORC) and Seasonal Thermal Energy Storage (STES) systems. With an application to the As-Samra WWTP located in Jordan, the developed ANN model demonstrates promising results in the validation phase, with a root mean square error (RMSE) of 2206 kWh/day, a mean absolute error (MAE) of 1674 kWh/day, and an R-squared (R 2 ) value of 68%. On the other hand, the economic analysis reveals that an optimal ORC system of 412.14 kW e capacity yields a Net Present Value (NPV) of 2.09 million US dollars, a Levelized Cost of Energy (LCOE) of 0.0749 USD/kWh, a Payback Period (PBP) of 4.8 years, and annual revenues of 428 kUSD. This work also investigates the techno-economic feasibility of integrating ORC-STES. Results indicate that the LCOE and PBP are highly affected by the ORC's capital cost, and integrating STES increases the LCOE to 0.0824 USD/kWh, rendering its integration with ORC infeasible. In conclusion, this study aims to advance the understanding and application of WHR in WWTPs, paving the way for more efficient and sustainable practices in the field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Idaho Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Idaho homeowners. Moving to the 2012 IECC from the 2009 IECC is cost-effective over a 30-year life cycle. On average, Idaho homeowners will save $\$$4,057 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$285 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Michigan Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the Michigan Uniform Energy Code

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Michigan homeowners. Moving to the 2012 IECC from the Michigan Uniform Energy Code is cost-effective over a 30-year life cycle. On average, Michigan homeowners will save $\$$10,081 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$604 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nevada Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Nevada homeowners. Moving to the 2012 IECC from the 2009 IECC is cost-effective over a 30-year life cycle. On average, Nevada homeowners will save $\$$4,736 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 2 years for the 2012 IECC. Average annual energy savings are $\$$360 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ohio Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IECC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Ohio homeowners. Moving to the 2012 IECC from the 2009 IECC is cost-effective over a 30-year life cycle. On average, Ohio homeowners will save $\$$5,151 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$330 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pennsylvania Energy and Cost Savings for New Single- and Multifamily Homes: 2012 IECC as Compared to the 2009 IRC

The 2012 International Energy Conservation Code (IECC) yields positive benefits for Pennsylvania homeowners. Moving to the 2012 IECC from Chapter 11 of the 2009 International Residential Code (IRC) is cost-effective over a 30-year life cycle. On average, Pennsylvania homeowners will save $\$$8,632 with the 2012 IECC. Each year, the reduction to energy bills will significantly exceed increased mortgage costs. After accounting for up-front costs and additional costs financed in the mortgage, homeowners should see net positive cash flows (i.e., cumulative savings exceeding cumulative cash outlays) in 1 year for the 2012 IECC. Average annual energy savings are $\$$515 for the 2012 IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cabauw Experimental Results from the Project for Intercomparison of Land-Surface Parameterization Schemes

In the Project for Intercomparison of Land-Surface Parameterization Schemes phase 2a experiment, meteorological data for the year 1987 from Cabauw, the Netherlands, were used as inputs to 23 land-surface flux schemes designed for use in climate and weather models. Schemes were evaluated by comparing their outputs with long-term measurements of surface sensible heat fluxes into the atmosphere and the ground, and of upward longwave radiation and total net radiative fluxes, and also comparing them with latent heat fluxes derived from a surface energy balance. Tuning of schemes by use of the observed flux data was not permitted. On an annual basis, the predicted surface radiative temperature exhibits a range of 2 K across schemes, consistent with the range of about 10 W/m in predicted surface net radiation. Most modeled values of monthly net radiation differ from the observations by less than the estimated maximum monthly observational error (+/- 10 W/sq m). However, modeled radiative surface temperature appears to have a systematic positive bias in most schemes; this might be explained by an error in assumed emissivity and by models' neglect of canopy thermal heterogeneity. Annual means of sensible and latent heat fluxes, into which net radiation is partitioned, have ranges across schemes of 30 W/sq m and 25 W/sq m, respectively. Annual totals of evapotranspiration and runoff, into which the precipitation is partitioned, both have ranges of 315 mm. These ranges in annual heat and water fluxes were approximately halved upon exclusion of the three schemes that have no stomatal resistance under non-water-stressed conditions. Many schemes tend to underestimate latent heat flux and overestimate sensible heat flux in summer, with a reverse tendency in winter. For six schemes, root-mean-square deviations of predictions from monthly observations are less than the estimated upper bounds on observation errors (5 W/m for sensible beat flux and 10 W/m for latent heat flux). Actual runoff at the site is believed to be dominated by vertical drainage to ground water, but several schemes produced significant amounts of runoff as overland flow or interflow. There is a range across schemes of 184 mm (40% of total pore volume) in the simulated annual mean root-zone soil moisture. Unfortunately, no measurements of soil moisture were available for model evaluation. A theoretical analysis suggested that differences in boundary conditions used in various schemes are not sufficient to explain the large variance in soil moisture. However, many of the extreme values of soil moisture could be explained in terms of the particulars of experimental setup or excessive evapotranspiration.

Chen, Tian Hong↗

The nature of frontier orbitals under systematic ligand exchange in (pseudo-)octahedral Fe( ii ) complexes

Understanding and controlling properties of transition metal complexes is a crucial step towards tailoring materials for sustainable energy applications. In a systematic approach, we use resonant inelastic X-ray scattering to study the influence of ligand substitution on the valence electronic structure around an aqueous iron(II) center. Exchanging cyanide with 2-2'-bipyridine ligands reshapes frontier orbitals in a way that reduces metal 3d charge delocalization onto the ligands. This net decrease of metal–ligand covalency results in lower metal-centered excited state energies in agreement with previously reported excited state dynamics. Furthermore, traces of solvent-effects were found indicating a varying interaction strength of the solvent with ligands of different character. Lastly, our results demonstrate how ligand exchange can be exploited to shape frontier orbitals of transition metal complexes in solution-phase chemistry; insights upon which future efforts can built when tailoring the functionality of photoactive systems for light-harvesting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗